首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Two-step stacking of organic anions by sweeping and micelle to solvent stacking (MSS) using cationic cetyltrimethylammonium micelles in co-electroosmotic flow (co-EOF) capillary zone electrophoresis (CZE) is described. The co-EOF condition where the direction of the EOF is the same as the test anions was satisfied by positive dynamic coating of a fused silica capillary with hexadimethrine bromide. The strategy was as follows. After conditioning the capillary with the background solution (BGS), a micellar solution (MS) was injected before the sample solution (S). The BGS, MS and S have similar conductivities. Voltage was applied at negative polarity. The analytes in the micelle-free S zone were swept by micelles from the MS. The swept analytes were brought by the micelles to the MSS boundary where the second stacking step was induced by the presence of organic solvent in the BGS. Finally was the separation of concentrated analytes by CZE. The effect of electrolyte concentration in the S, injection time of the MS and the S and surfactant concentration in the MS were studied. A 20-29, 17-33 and 18-21 times increase in peak height sensitivity was obtained for the test hypolipidaemic drugs (gemfibrozil, fluvastatin and atorvastatin), non-steroidal anti-inflammatory drugs (diflunisal, naproxen, ketoprofen, indoprofen and indomethacin), and herbicides (mecoprop and fenoprop), respectively. The LODs (S/N=3) were from 0.05 to 0.55 μg/mL. The intraday and interday repeatabilities (%RSD, n=12) in terms of retention time, corrected peak area, and peak heights was less than 3.6, 8.9, and 10.8%, respectively. The application of sweeping and MSS in co-EOF CZE together with a simple extraction procedure to a waste water sample spiked with the test herbicides was also demonstrated.  相似文献   

2.
On-line preconcentration methods for capillary electrophoresis   总被引:3,自引:0,他引:3  
Osbourn DM  Weiss DJ  Lunte CE 《Electrophoresis》2000,21(14):2768-2779
The limits of detection (LOD) for capillary electrophoresis (CE) are constrained by the dimensions of the capillary. For example, the small volume of the capillary limits the total volume of sample that can be injected into the capillary. In addition, the reduced pathlength hinders common optical detection methods such as UV detection. Many different techniques have been developed to improve the LOD for CE. In general these techniques are designed to compress analyte bands within the capillary, thereby increasing the volume of sample that can be injected without loss of CE efficiency. This on-line sample preconcentration, generally referred to as stacking, is based on either the manipulation of differences in the electrophoretic mobility of analytes at the boundary of two buffers with differing resistivities or the partitioning of analytes into a stationary or pseudostationary phase. This article will discuss a number of different techniques, including field-amplified sample stacking, large-volume sample stacking, pH-mediated sample stacking, on-column isotachophoresis, chromatographic preconcentration, sample stacking for micellar electrokinetic chromatography, and sweeping.  相似文献   

3.
Methotrexate (MTX) is widely used for the treatment of many types of cancer. Folinic acid (FNA) and folic acid (FA) were usually simultaneously supplemented with MTX to reduce the side effects of a folate deficiency. This study, for the first time, included on‐line sample preconcentration by stacking and sweeping techniques under reduced or enhanced electric conductivity in the sample region using short chain alkyl imidazolium ionic liquids (ILs) as micelle forming agents for analyte focusing. Both analyte focusing by micelle collapse (AFMC) and sweeping‐MEKC had been investigated for the comparison of their effectiveness to examine simultaneously MTX, FNA and FA in plasma and urine under physiological conditions. In sweeping‐MEKC, the sample solution without micelles was hydrodynamically injected as a long plug into a fused‐silica capillary pre‐filled with phosphate buffer containing 3.0 mol/L of 1‐butyl‐3‐methylimidazolium bromide (BMIMBr). Using AFMC, the analytes were prepared in BMIMBr micellar matrix and hydrodynamically injected into the phosphate buffer without IL micelles. The conductivity ratio between BGE and sample (γ, BGE/sample) was optimized to be 3.0 in sweeping‐MEKC and 0.33 in AFMC resulting the adequate separation of analytes within 4.0 min. To reduce the possibility of BMIMBr adsorption, an appropriate rinsing protocol was used. The limits of detection were calculated as 0.1 ng/mL MTX, 0.05 ng/mL FNA and 0.05 ng/mL FA by sweeping‐MEKC and 0.5 ng/mL MTX, 0.3 ng/mL FNA and 0.3 ng/mL FA by AFMC. The accuracy was tested by recovery in plasma and urine matrices giving values ranging between 90 and 110%. Both stacking and sweeping by BMIMBr could be successfully used for the rapid, selective and sensitive determination of pharmaceuticals in complex matrices due to its fascinating properties, including high conductivity, good thermal stability and ability to form different types of interactions by electrostatic, hydrophobic, hydrogen bonding and π–π interactions. In sweeping‐MEKC, the using of BMIMBr enhanced the γ factor, k retention factor and the injected amount of sample. Consequently, this technique offers particular potential for higher sensitivity by giving 22‐ and 5‐fold sensitivity enhancement factors (SEFs) of MTX compared to CZE and AFMC, respectively.  相似文献   

4.
We present a new system for the sensitive analysis of cephalosporins by CE using both on-line SPE and large-volume sample stacking (LVSS). Sample volumes of 250 muL were loaded onto the SPE microcolumn which was then desorbed with 426 nL of ACN. The SPE elution plug was injected into the CE system via an in-line valve interface filling approximately 60% of the volume of the separation capillary. Subsequently, LVSS was performed by applying a voltage of -5 kV, which resulted in the simultaneous removal of the elution solvent and the preconcentration of the analytes in a narrow zone. This way the amount of analyte loaded into the capillary could be considerably increased without serious loss of CE separation efficiency. LODs for cefoperazone and ceftiofur were in the ng/L range which represents an improvement of a factor of 8450 and 11 450 when compared with direct CE injection. The cephalosporin test compounds presented a good linear response (corrected peak area) between 0.5 and 10 mug/L with correlation coefficients higher than 0.995. The final method is compared with previously reported LVSS-CE and SPE-CE systems for the analysis of cephalosporins.  相似文献   

5.
JP Quirino  AT Aranas 《Electrophoresis》2012,33(14):2167-2175
In this paper, by injecting a SDS micellar plug before the sample prepared in aqueous organic solvents, we show the on-line sample preconcentration of cations via micelle to solvent stacking (MSS) using solvents of as low as 30%. This extends the choice of stacking techniques to include moderate amounts of organic solvent in the sample. The approach is akin to in-line solid phase extraction where the micellar plug acted as a transient micellar phase extractor. Basic studies were conducted (e.g. type and amount of organic solvent in the sample). The calculated sensitivity enhancement factors based on LOD obtained for the six test antipsychotic drugs were from 41 to 68. The peak signals were linear (R2 > 0.99) from 0.2 to 10.0 μg/mL. The intraday and interday reproducibility (n = 10) for migration time, peak height, and corrected peak area were from 0.2 to 13.6%. The technique was also tested on spiked wastewater sample with minimal sample treatment (i.e. dilution and centrifugation).  相似文献   

6.
Micellar electrokinetic capillary chromatography (MEKC) with diode array detection was used for the separation of 13 compounds (eight herbicides widely used in agriculture: metribuzin, lenacil, ethofumesate, atrazine, terbutryn, isoproturon, chlorotoluron and linuron, and five of their principal degradation products; namely, deethylatrazine, 2-hydroxyatrazine, deethyl-2-hydroxyatrazine, deisopropylatrazine and 3-chloro-4-methylphenylurea). Peak separation for the 13 analytes was not successful when a single surfactant system was employed, neither sodium dodecyl sulfate (SDS) nor dioctyl sulfosuccinate (DOSS) sodium salt. However, a mixture of these herbicides was successfully separated using a mixed micellar system involving SDS–DOSS in less than 14 min. An application study of an on-line concentration technique for MEKC was carried out to enhance sensitivity. The optimized on-line stacking procedure consisted simply of the addition of 50 mM of sodium chloride to the injection sample, the stacking effect being more intensive as analyte polarity increased. When this stacking procedure was combined with an off-line sample preconcentration step, based on solid-phase extraction, analytes could be detected in the ppb range. The whole method was applied to ultra-high-quality and natural waters. Linear relationships between the analytical signal and the initial analyte concentration were found to be independent of the type of water, except for the more polar analytes for which small differences were observed.  相似文献   

7.
Micelle to solvent stacking (MSS) is a new on-line sample concentration technique for charged analytes in capillary zone electrophoresis (CZE). Sample concentration in MSS mainly relies on the reversal in the effective electrophoretic mobility of the analyte at the boundary zone between the sample solution (S) and CZE background solution (BGS) inside the capillary. The basic condition for MSS is that the S is prepared in a matrix that contains an additive (i.e., micelles) which interacts with and has an opposite charge compared to the analytes. In addition, the BGS must contain a sufficient percentage of organic solvent. MSS was first reported for organic cations using anionic dodecyl sulfate micelles as additive in the S and methanol or acetonitrile as organic solvent in the BGS. Here, theoretical and experimental studies on MSS are described for organic anions using cationic cetyltrimethyl ammonium micelles as additive in the S and methanol as organic solvent in the BGS. Up to an order of magnitude improvement in concentration sensitivity was obtained for the test hypolipidaemic drugs using MSS in CZE with UV detection. The optimized method was also evaluated to the analysis of a spiked wastewater sample that was subjected to a simple extraction step.  相似文献   

8.
When using capillary electrophoresis (CE) for the analysis of biological samples, it is often necessary to employ techniques to overcome peak-broadening that results from having a high-conductivity sample matrix. To improve the concentration detection limits and separation efficiency of cationic pharmaceuticals in CE, pH-mediated acid stacking was performed to electrofocus the sample, improving separation sensitivity for the analyzed cations by 60-fold. However, this method introduces a large titrated acid plug into the capillary. To overcome the limitations this low-conductivity plug poses to stacking, the plug was removed prior to the separation step by applying reverse pressure to force it out of the anode of the capillary. Employing this technique allows for roughly twice the volume of sample to be injected. A maximum sample injection time of 240 s was attainable with baseline peak resolution compared to a maximum sample injection time of 120 s without reverse pressure, leading to a twofold decrease in the limits of detection of the analytes used. Separation efficiency overall is also improved when utilizing the reverse pressure step. For example, a 60 s sample injection time results in 94,000 theoretical plates as compared to 60,500 theoretical plates without reverse pressure. This reverse-pressure method was used for detection and quantitation of several cationic pharmaceuticals that were prepared in Ringer's solution to simulate microdialysis sampling conditions.  相似文献   

9.
Ràfols C  Poza A  Fuguet E  Rosés M  Bosch E 《Electrophoresis》2002,23(15):2408-2416
The experimental conditions that produce analyte peak splitting in micellar electrokinetic capillary chromatography (MEKC) have been systematically investigated. The system studied was a neutral phosphate buffer and sodium dodecyl sulfate (SDS) micelles as pseudostationary phase. A number of analytes showing a wide variety of hydrophobicity values and several organic solvents as sample diluents have been tested. Peak splitting phenomena are mainly due to the presence of organic solvent in the sample solution. They increase with the hydrophobicity of the analyte and decrease with the increase of the surfactant concentration. When hydrophobic compounds are analyzed the suggested ways to avoid split peaks are: (i) the use of 1-propanol or 1-butanol as sample diluent instead of methanol or acetonitrile or (ii) the use of high concentration of surfactant in the separating solution when the analyte must be dissolved in pure methanol or acetonitrile.  相似文献   

10.
The on-line sample concentration technique, micelle to solvent stacking (MSS), was studied for small organic cations (quaternary ammonium herbicides, β-blocker drugs, and tricyclic antidepressant drugs) in reversed migration micellar electrokinetic chromatography. Electrokinetic chromatography was carried out in fused silica capillaries with a background solution of sodium dodecyl sulfate (SDS) in a low pH phosphate buffer. MSS was performed using anionic SDS micelles in the sample solution for analyte transport and methanol or acetonitrile as organic solvent in the background solution for analyte effective electrophoretic mobility reversal. The solvent also allowed for the separation of the analyte test mixtures. A model for focusing and separation was developed and the mobility reversal that involved micelle collapse was experimentally verified. The effect of analyte retention factor was observed by changing the % organic solvent in the background solution or the concentration of SDS in the sample matrix. With an injection length of 31.9 cm (77% of effective capillary length) for the 7 test drugs, the LODs (S/N=3) of 5-14 ng/mL were 101-346-fold better when compared to typical injection. The linearity (R(2), range=0.025-0.8 μg/mL), intraday and interday repeatability (%RSD, n=10) were ≥0.988, <6.0% and <8.5%, respectively. In addition, analysis of spiked urine samples after 10-fold dilution with the sample matrix yielded LODs=0.02-0.10 μg/mL. These LODs are comparable to published electrophoretic methods that required off-line sample concentration. However, the practicality of the technique for more complex samples will rely on dedicated sample preparation schemes.  相似文献   

11.
The performance of micelle to solvent stacking (MSS) in capillary zone electrophoresis (CZE) was improved for anionic analytes using the long chain ionic liquid type cationic surfactant 1-dodecyl-3-methylimidazolium tetrafluoroborate (C12-MIM-BF4). The peak heights and corrected peak areas of the test profens and herbicides were enhanced up to 59 and 110-fold, respectively when compared to typical injection. These were up to 10 times better compared to the surfactant cetyltrimethyl ammonium bromide as MSS carrier. This performance was attributed to the properties of C12-MIM-BF4. MSS requires micelles in the sample for transport of bound analytes to a stacking boundary that contains an organic solvent for effective electrophoretic mobility reversal. The ionic liquid micelles provided better analyte transport properties that resulted from its hydrophobic and pi–pi interaction capabilities. The good solubility of the ionic liquid in high percentages of organic solvent also facilitated a more effective reversal of mobility. The LODs obtained for the test analytes were from 0.06 to 0.12 μg/mL. The linearity R2 values in terms of peak height and corrected area were ≥0.99. The interday repeatabilities (%RSD, n = 10,) were 0.5–2.2% for retention time, 1.9–4.7% for corrected areas and 4.1–6.4% for peak heights.  相似文献   

12.
Online sample concentration of acidic drugs by transient isotachophoresis (t-ITP) with the injection of a base is described in capillary zone electrophoresis (CZE). A positively coated capillary was conditioned with background electrolyte (ammonium acetate at pH 6). A long plug of sample solution (S) prepared in ammonium acetate was then hydrodynamically injected followed by the base (tetrapropylammonium hydroxide). A negative voltage was applied and caused the hydroxide ions from the base to penetrate the S zone and created a pH junction that swept through the S zone. The analytes stack at the junction where the mechanism of focusing was transient ITP with the acetate and hydroxide ions as leading and terminating ions, respectively. The concentrated analytes separated in co-EOF CZE once the hydroxide was exhausted. The base stacking strategy was tested using hypolipidemic, nonsteroidal anti-inflammatory, and diuretic drugs, and afforded 19-37 improvements in peak height.  相似文献   

13.
A new on-line preconcentration technique was developed that makes possible to determine nanomolar concentrations of weak acidic analytes in CE. The method consists of long-running electrokinetic sample injection and stacking (electrokinetic immobilization) of the analytes at a boundary of two electrolytes with different pH values (pH 9.5 and 2.5) and consequent mobilization of the stacked uncharged analytes in a micellar system (containing SDS micelles). Several factors including buffer concentration, pH, applied voltage, time of preconcentration, and SDS concentration were tested to optimize the analysis method. An about 4600-fold increase of the sample concentration (in comparison with the standard CZE) can be achieved during the preconcentration step. Two preservatives applied in food industry -- benzoic acid and sorbic acid were used as model samples. The applicability of the proposed method in food analysis was demonstrated by determination of nanomolar concentrations of benzoic acid in sunflower oil. An extended version of the computer program Simul was used for modeling both the preconcentration and mobilization processes taking place in the capillary.  相似文献   

14.
毛细管电泳中高盐样品在线富集的研究进展   总被引:1,自引:0,他引:1  
张薇  曹成喜 《分析化学》2005,33(2):267-271
在毛细管电泳分析过程中,简便高效的高盐样品处理技术对血清、尿液、海水和工业废水等样品的富集分析具有重要的意义。综述了在CE中高盐样品在线富集的若干种方法,包括乙腈法、瞬间等速电泳法、pH修饰法、动态pH联接法、胶束反应法和瞬间移动化学反应界面法,并简要地介绍它们的应用和研究进展。  相似文献   

15.
《Analytical letters》2012,45(12):1975-1985
Abstract

A detailed study was carried out to investigate the origin of the peak‐splitting phenomena in on‐column concentration‐micellar electrokinetic capillary chromatography for aqueous sample solution. The system studied was a basic phosphate and borax mixed buffer with sodium dodecyl sulfate (SDS) as micellar phase. Phenol, benzyl alcohol, phenyl ethanol, salicylic acid, and p‐hydroxy benzyl acid were selected as the analytes. Several factors that affect peak splitting were investigated. The injection time, SDS micellar concentration, hydrophobicity of the analytes, and analytes concentration were the most important factors. A hypothesis was proposed to explain the peak‐splitting phenomena. Several means to avoid peak‐splitting phenomena were proposed, such as controlling sample injection time and hydrophobicity of the analyte, decreasing SDS concentration and increasing sample concentration. However, the most practical method for avoiding peak splitting was to control the sample injection time.  相似文献   

16.
T Hirokawa  H Okamoto  N Ikuta 《Electrophoresis》2001,22(16):3483-3489
Operational modes for transient isotachophoretic preconcentration capillary zone electrophoresis (tr-ITP-CZE) were studied by using 5 microM and 0.5 microM rare earth mixtures as analytes in comparison with field-enhanced sample stacking. After examination of several operational modes for tr-ITP, it was found that tr-ITP effectively occured even if both the leading electrolyte and the terminating electrolyte were injected after the sample plug. This was explained as the result of a field-enhanced stacking for both sample components and the leading and terminating ions. The observed theoretical plate numbers were 4-20 times higher than those obtained by normal stacking; and the estimated low limit of detectable concentration of rare-earth elements (REE) was ca. 0.1 microM which was 2.5 times lower compared to normal stacking. For the 0.5 microM sample, a concentration factor of 20 000 could be achieved after only tr-ITP.  相似文献   

17.
Wang CC  Chiou SS  Wu SM 《Electrophoresis》2005,26(13):2637-2642
This study describes approaches for stacking a large volume of sample solutions containing a mixture of mercaptopurine monohydrate, 6-methylmercaptopurine, thioguanine, thioguanosine, and thioxanthine in capillary electrophoresis (CE). After filling the run buffer (60 mM borate buffer, pH 8.5), a large sample volume was loaded by hydrodynamic injection (2.5 psi, 99.9 s), followed by the removal of the large plug of sample matrix from the capillary using polarity switching (-15 kV). Monitoring the current and reversing the polarity when 95% of current recovered, the separation of anionic analytes was performed in a run buffer < 20 kV. Around 44- to 90-fold improvement of sensitivity for five analytes was achieved by large-volume stacking with polarity switching when compared with CE without stacking. This method was feasible for determination of the analytes spiked in plasma. Removing most of electrolytes from plasma is a key step for performing large-volume sample stacking. Solid-phase extraction was used for pretreatment of biological samples. To our knowledge, this study is one of few applications showing the possibilities of this stacking procedure to analyze biological samples by large-volume sample stacking with polarity switching (LVSSPS) in CE.  相似文献   

18.
Fang H  Yang F  Sun J  Zeng Z  Xu Y 《Electrophoresis》2007,28(20):3697-3704
This paper describes a novel method that applies pressure-assisted field-amplified sample injection with reverse migrating micelles (PA-FASI-RMM) for the online concentration of neutral analytes in MEKC with a low-pH BGE. After injection of a plug of water into the separation capillary, negative voltage and positive pressure were simultaneously applied to initialize PA-FASI-RMM injection. The hydrodynamic flow generated by the positive pressure compensated the reverse EOF in the water plug and allowed the water plug to remain in the capillary during FASI with reverse migrating micelles (FASI-RMM) to obtain a much longer injection time than usual, which improved stacking efficiency greatly. Equations describing this injection mode were introduced and were supported by experimental results. For a 450-s online PA-FASI-RMM injection, three orders of magnitude sample enhancement in terms of peak area could be observed for the steroids and an achievement of detection limits was between 1 and 10 ng/mL.  相似文献   

19.
Qin WH  Cao CX  Li S  Zhang W  Liu W 《Electrophoresis》2005,26(16):3113-3124
The paper advanced the theoretical procedures for quantitative design on selective stacking of zwitterions in full capillary sample matrix by a cathodic-direction moving reaction boundary (MRB) in capillary electrophoresis (CE) under control of electroosmotic flow (EOF). With the procedures, we conducted the theoretical computations on the selective stacking of two test analytes of L-histidine (His) and L-tryptophan (Trp) by the MRB created with 30 mM pH 3.0 formic acid-NaOH buffer and 2-80 mM sodium formate. The results revealed the following three predictions. At first, the MRB cannot stack His and Trp plugs if less than 12.5 mM sodium formate is used to form the MRB and prepare the sample matrix. Second, the MRB can stack His and/or Trp sample plugs completely if higher than 50 mM sodium formate is chosen to form the MRB. Third, the MRB can only focus His plug completely, but stack Trp plug partially if 20-50 mM sodium formate is used; this implied the complete MRB-induced selective stacking to His rather than Trp. All the three predictions were quantitatively proved by the experiments. With great dilution of sample matrix and control of EOF, controllable, simultaneous and MRB-induced selective stacking and separation of zwitterions were achieved. The theoretical results hold evident significances to the quantitative design of selective stacking conditions and the increase of detection sensitivity of zwitterions in CE. In addition, the control of EOF by cetyltrimethylammonium bromide (CTAB) can evidently improve the stacking efficiency to both His and Trp.  相似文献   

20.
The stacking of a cationic analyte (i.e., rhodamine B) at the interface between a sample reservoir and channel in a microchip electrophoresis device is described for the first time. Stacking at negative polarity was by micelle to solvent stacking where the dye was prepared in a micellar solution (5 mM sodium dodecyl sulfate in 25 mM phosphoric acid, pH 2.5) and the channel was filled with high methanol content background solution (70% methanol in 50 mM phosphoric acid, pH 2.5). The injection of the stacked dye into the channel was by simple reversal of the voltage polarity with the sample solution and background solution at the anodic and cathodic reservoirs of the straight channel, respectively. The enrichment of rhodamine B at the interface and injection of the stacked dye into the channel was clearly visualized using an inverted fluorescence microscope. A notable sensitivity enhancement factor of up to 150 was achieved after 2 min at 1 kV of micelle to solvent stacking. The proposed technique will be useful as a concentration step for analyte mixtures in simple and classical cross‐channel microchip electrophoresis devices or for the controlled delivery of enriched reagents or analytes as narrow plugs in advanced microchip electrophoresis devices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号