首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Fly ash has been regarded as hazardous because of its high adsorption of toxic organic and/or inorganic pollutants. Fly ash is also known to have broad distributions of different chemical and physical properties, such as size and density. In this study, fly ash emitted from a solid waste incinerator was pre-fractionated into six sub-populations by use of gravitational SPLITT fractionation (GSF). The GSF fractions were then analyzed by sedimentation field-flow fractionation (SdFFF) and ICP–AES. SdFFF analysis showed the fly ash has a broad size distribution ranging from a few nanometers up to about 50 µm. SdFFF results were confirmed by electron microscopy. Inductively coupled plasma–atomic emission spectroscopy (ICP–AES) analysis of the GSF fractions showed the fly-ash particles contain a variety of inorganic elements including Ca, Si, Mg, Fe, and Pb. The most abundant in fly ash was Ca, followed by Si then Mg. No correlations were found between trace element concentration and particle size.  相似文献   

2.
Four types of SiO2, available on the market as additives in food and personal care products, were size characterized using Sedimentation Field Flow Fractionation (SdFFF), SEM, TEM and Photon Correlation Spectroscopy (PCS). The synergic use of the different analytical techniques made it possible, for some samples, to confirm the presence of primary nanoparticles (10 nm) organized in clusters or aggregates of different dimension and, for others, to discover that the available information is incomplete, particularly that regarding the presence of small particles. A protocol to extract the silica particles from a simple food matrix was set up, enriching (0.25%, w w−1) a nearly silica-free instant barley coffee powder with a known SiO2 sample. The SdFFF technique, in conjunction with SEM observations, made it possible to identify the added SiO2 particles and verify the new particle size distribution. The SiO2 content of different powdered foodstuffs was determined by graphite furnace atomic absorption spectroscopy (GFAAS); the concentrations ranged between 0.006 and 0.35% (w w−1). The protocol to isolate the silica particles was so applied to the most SiO2-rich commercial products and the derived suspensions were separated by SdFFF; SEM and TEM observations supported the size analyses while GFAAS determinations on collected fractions permitted element identification.  相似文献   

3.
Sedimentation field-flow fractionation (SdFFF) can be used to prepare fractions of very narrow mass range for electron microscopic (EM) analysis. Assuming the particle density is the same for all particles within that fraction the equivalent spherical diameter for the particles can be calculated from SdFFF theory. Integration of the micrograph image of each particle yields an area measurement which, when used in conjunction with the equivalent spherical particle diameter (from SdFFF), provides information about the particle thickness and aspect ratio. Thus SdFFF-SEM can be used to provide detailed information about clay morphology across the particle size distribution of the sample. Three clay minerals have been studied using the methodologies outlined in this paper. The aspect ratio for the Purvis School Mine kaolinite ranged from 2.8–5.9, for RM30 illite from 11.3–24.3, and for Muloorina illite from 3.1–4.3.  相似文献   

4.
Direct hyphenation of electrothermal atomic-absorption spectroscopy (ETAAS) to sedimentation field-flow fractionation (SdFFF) has been developed to enable elemental characterization of submicron particles as a function of size. This hyphenation is particularly suitable for characterizing colloidal particles of environmental interest, for example water-borne particles. The interface is an automatic capillary injection device (CID) which enables direct introduction of large and variable volumes of colloidal particle suspensions into a hot graphite furnace, thus preconcentrating the colloidal particles on the furnace walls. The method was validated by determination of Fe in certified submicron Fe2O3. The procedure was set up by first optimizing the SdFFF fractionation under programmed field conditions, thus enabling optimum fractionation of particle size. The ETAAS procedure was then tested to determine whether it could be used for direct analysis of Fe2O3 slurries without the need for a mineralization step. CID coupled to ETAAS was subsequently exploited for its ability to enhance the sensitivity, because of the increased injection volume. Statistical tests and data handling were conducted to prove the suitability of the ETAAS-CID module. Finally, off-line and on-line ETAAS-CID-SdFFF hyphenation were investigated. These experiments emphasized the advantages of the on-line coupling, because it enables synchronized sampling, enrichment, and elemental analysis of the flowing eluate. The benefits of the proposed hyphenation are the high specificity of analytical detection, increased sensitivity, reduction of analysis time, and minimum sample handling and contamination.   相似文献   

5.
In order to elucidate the distributions of the elements among the particulate and dissolved fractions in pond water, major-to-ultratrace elements in different sizes of particles as well as in the filtrate passed through the 0.05 microm filter were determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). The different sizes of particle samples (ca. 100-300 microg each) were collected on the membrane filters with pore sizes of 10, 3.0, 1.2, 0.4, 0.2 and 0.05 microm, respectively, by sequential fractionation. As a result, about 40 elements in different sizes of particles could be determined by ICP-AES and ICP-MS, after acid digestion using HNO3/HF/HClO4. Then, the fractional distribution factors of major-to-ultratrace elements among the particulate and dissolved fractions were estimated from the analytical results. The total contents of Al, Fe, Ti, REEs (rare earth elements), Bi, Pb and Ag in the particulate fractions (larger than 0.05 microm) were more than 80-90%, while those of Ca, Sr, Cs, W, Ba, Mn and Co in the dissolved fraction, which corresponded to the filtrate passed through the 0.05 microm membrane filter, were more than 80%. It was further found that the fractional distributions of Cu and Zn in the dissolved fraction were ca. 50%. In addition, the enrichment factors (EFs) of the elements in the particulate fractions with particle sizes of 3.0-10 microm and 0.05-0.2 microm were estimated to elucidate their geochemical characteristics in natural water.  相似文献   

6.
Despite the large number of successful applications of laser ablation, elemental and isotopic fractionation coupled to inductively coupled plasma mass spectrometry (ICP-MS) remain as the main limitations for many applications of this technique in the fields of analytical chemistry and Earth Sciences. A substantial effort has been made to control such fractionations, which are well-established features of nanosecond laser ablation systems. Technological advancements made over the past decade now allow the ablation of solids by femtosecond laser pulses in the deep ultraviolet (UV) region at wavelengths less than 200 nm. Here the use of femtosecond laser ablation and its effects on elemental and isotopic fractionation is investigated. The Pb/U system is used to illustrate elemental fractionation and stable Fe isotopes are used to illustrate isotopic fractionation. No elemental fractionation is observed beyond the precision of the multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements. Without a matrix match between standard and sample, elemental fractionation is absent even when using different laser ablation protocols for standardization and samples (spot versus raster). Furthermore, we found that laser ablation-induced isotope ratio drifts, commonly observed during nanosecond laser ablation, are undetectable during ultraviolet femtosecond laser ablation. So far the precision obtained for Fe isotope ratio determinations is 0.1‰ (2 standard deviation) for the 56Fe/54Fe ratio. This is close to that obtainable by solution multiple-collector inductively coupled plasma mass spectrometry. The accuracy of the results appears to be independent of the matrix used for standardization. The resulting smaller particle sizes reduce fractionation processes. Femtosecond laser ablation carries the potential to solve some of the difficulties encountered during the two prior decades since the introduction of laser ablation.  相似文献   

7.
Gravitational field-flow fractionation (FFF) coupled to UV and ETAAS detectors has been tested for micron-size particles in the range of 5–20 μm using three Fe-rich clay samples. The iron content estimated after aqua regia extraction was about 20–40 mg kg−1. The ETAAS analysis was performed both off-line from collected fractions and in an online continuous sampling mode using a specially designed flow through vial placed in the autosampler of the ETAAS. Comparison of the direct injection method with total analysis after aqua regia digestion shows that slurry injection of the dilute samples in the gravitational field-flow fractionation (GrFFF) effluent is quite efficient in these samples. In the majority of cases, more than 90% recovery was obtained for the slurry injection method. Fe mass-based particle size distributions and Fe concentration versus particle diameter plots can be generated using certain assumptions. This provides detailed information on size-based speciation of particulate samples. Generally, the Fe concentrations in the particles decreased slightly with an increase in particle size as is often found for soil and sediment samples.  相似文献   

8.
Gold nanoparticles (GNPs) have been synthesized through the citrate reduction method; the citrate/gold(III) ratio was changed from 1:1 up to 10:1 and the size of the resulting nanoparticles was measured by sedimentation field-flow fractionation (SdFFF). Experimental data showed that the GNPs size decreases in the ratio range 1:1–3:1 and then increases from 5:1 to 10:1 passing through a plateau region in between, and is almost independent of the precursor solution concentrations. In the zone of minimum diameters the synthetic process does not produce monodispersed GNPs but often multiple distributions, very close in size, are observed as evidenced by the particle size distributions (PSDs) derived from the SdFFF fractograms. UV–vis spectrophotometry, being the most common technique employed in the optical characterization of nanoparticles suspensions, was used throughout this work. A confirmation of the nucleation–aggregation–fragmentation mechanism was inferred from the cross-correlation between UV–vis and SdFFF results.  相似文献   

9.
The present study summarizes the last ten years of literature on heavy metal distribution in Suspended Particulate Matter (SPM) and dissolved phase in the Po River (Italy). The work compares different methodologies employed to collect, concentrate and fractionate the samples. The importance of metal speciation as a function of particle size is underlined and two approaches to metal speciation in the colloidal fraction of Po River SPM are presented: Sedimentation Field-Flow Fractionation (SdFFF) and pH-dependent extractions. Finally, emphasis is placed on the need for comparison with a reference "natural background level" of the metal load in Po River particulate matter in order to determine the real human contribution to river pollution. The high values of some trace transition elements, such as Cr and Ni, have been compared with clay sediments around Ferrara and with bricks in historic buildings. The highly comparable natural concentration of these metals in Po fine sedimentary rocks and in historic brick buildings of Ferrara (XII-XVI centuries) can provide information on natural geochemical anomalies.  相似文献   

10.
In this work, SPLITT Fractionation (split flow thin cell) is used to sort hydrodynamically sedimented particles coming from the Sacca di Goro, a lagoon-like system close to the Po River delta (Italy). First the possibility of performing quantitative mass separations with a SPLITT cell apparatus was checked on a standard silica sample of known particle size distribution (PSD). Environmental sediment samples and relative SPLITT sub-fractions were subject to Inductive Coupled Plasma--Atomic Emission Spectroscopy (ICP-AES) characterization for the following elements: Al, Fe, Cd, Cr, Cu, Ni, Mn, Pb and Zn. The distribution of these metals by particle size fractions has been investigated. The accuracy of the entire separation procedure has been also evaluated.  相似文献   

11.
Ongoing discussions about the origin of elemental fractionation occurring during LA-ICP-MS analysis show that this problem is still far from being well understood. It is becoming accepted that all three possible sources (ablation, transport, excitation) contribute to elemental fractionation. However, experimental data about the vaporisation size limit of different particles in the ICP, as produced in laser ablation, have not been available until now. This information should allow one to determine the signal contributing mass within the ICP and would further clarify demands on suitable laser ablation systems and gas atmospheres in terms of their particle size distribution.The results presented here show a vaporisation size limit of laser induced particles, which was found at particle sizes between 90 nm and 150 nm using an Elan 6000 ICP-MS. Due to the fact that the ICP-MS response was used as evaluation parameter, vaporisation and ionisation limits are not distinguishable.The upper limit was determined by successively removing the larger particles from the aerosol, which was created by ablation of a NIST 610 glass standard at a wavelength of 266 nm, using a recently developed particle separation device. Various particle fractions were separated from the aerosol entering the ICP. The decrease in signal intensity is not proportional to the decrease in volume, indicating that particles above 150 nm in diameter are not completely ionised in the ICP. Due to the limited removal range of the particle separation device, which cannot remove particles smaller than 150 nm, single hole ablations were used to determine the lower vaporisation limit. This is based on measurements showing that larger particles occur dominantly during the first 100 laser pulses only. After this period, the ratio of ICP-MS counts and total particle volume was found to be constant while most of the particles are smaller than 90 nm, indicating complete vaporisation and ionisation of these particles.To describe the influence of different plasma forward powers on the vaporisation limit, the range 1000–1600 W was studied. Results indicate that optimum vaporisation and ionisation occurs at 1300 W. However, an increase of the particle ionisation limit towards larger particles was not observed within the accuracy of this study using the full range of parameters available for optimisation on commonly used ICP-MS instruments.  相似文献   

12.
A new sedimentation field flow fractionation (SdFFF) method is presented for the estimation of the total potential energy of interaction between colloidal particles and the channel wall. The method is based on the variation of the mean cloud thickness in SdFFF due to the variation of the suspension's ionic strength. It requires only two SdFFF experiments at two different ionic strengths and at a constant acceleration field. The found values are compatible with those calculated from the various forms of equations of the Derjaguin-Landau-Verwey-Overbeek (DLVO) theory.  相似文献   

13.
The influence of sample matrix composition, absorption behavior and laser aerosol particle size distribution on elemental fractionation in laser ablation inductively coupled plasma mass spectrometry was studied for nanosecond laser ablation at a wavelength of 266 nm. To this end, lithium tetraborate glass samples with different iron oxide contents and trace amounts of a group of 11 elements were prepared synthetically. The samples were characterized in terms of optical absorbance, melting points, trace element concentrations and homogeneity. UV/VIS spectra showed that sample absorption rises with increasing Fe2O3 content. Crater depths and time-dependent particle size distributions were measured, and ablated and transported sample volumes were estimated. Furthermore, the laser aerosol was filtered using a particle separation device and transient ICP-MS signals were acquired with and without filtering the aerosol. The results demonstrate that the amount of ablated sample is related to the absorption coefficient of the sample and therefore to the optical penetration depth of the laser beam into the sample. The higher energy densities resulting from the shorter penetration depths result in smaller average particle sizes for highly absorbing samples, which allows more efficient transport to and atomization and excitation of the ablated material within the ICP. The particle size distribution changes continuously with ablation time, and larger particle fractions occur mainly at the beginning of the ablation, which leads to particle-related fractionation processes at the beginning of the transient signal. Exceeding a critical depth to diameter ratio, laser-related elemental fractionation processes occur. Changes in the volatile to non-volatile element intensity ratio after the aerosol is filtered indicate that particle size-related enrichment processes contribute to elemental fractionation.  相似文献   

14.
The goal of this study was to show that sedimentation field-flow fractionation (SdFFF) could be used to study changes in the particle size distribution of perfluorocarbon (PFC) emulsion droplets in ex vivo whole blood samples. A PFC emulsion containing 40% w/v perfluorooctyl bromide (PFOB), 20% w/v perfluorodecyl bromide (PFDB), and 6% w/v egg yolk phospholipid (EYP) was manufactured by high pressure homogenization. The emulsion was infused intravenously to rats at a dose of 2.7 g PFC/kg body weight. Blood samples were collected at 0, 3, 6, and 24 h and analyzed (without additional sample manipulation) by SdFFF. Excellent chromatographic separation between the blood components and PFC emulsion droplets was achieved. After infusion, the particle size distribution broadened slightly. With time, the larger sized droplets were selectively removed by circulating monocytes and tissue resident macrophages of the reticuloendothelial system, causing the particle size distribution to shift to lower median diameters. SdFFF is an excellent technique for studying the in vivo stability of colloidal drug particles following intravenous administration.  相似文献   

15.
Zahoransky RA  Dummin H  Laile E  Schauer T 《Talanta》1997,44(12):2225-2230
The flow field-flow fractionation (FIFFF) technique is a promising method for separating and analysing particles and large size macromolecules from a few nanometers to approximately 50 μm. A new fractionation channel is described featuring well defined flow conditions even for low channel heights with convenient assembling and operations features. The application of the new flow field-flow fractionation channel is proved by the analysis of pigments and other small particles of technical interest in the submicrometer range. The experimental results including multimodal size distributions are presented and discussed.  相似文献   

16.
Enzymatic starch granule hydrolysis is one of the most important reactions in many industrial processes. In this study, we investigated the capacity of sedimentation field flow fractionation (SdFFF) to monitor the amylolysis of a bimodal starch population: native wheat starch. Results demonstrated a correlation between fractogram changes and enzymatic hydrolysis. Furthermore, SdFFF was used to sort sub-populations which enhanced the study of granule size distribution changes occurring during amylolysis. These results show the interest in coupling SdFFF with particle size measurement methods to study complex starch size/density modifications associated to hydrolysis. These results suggested different applications such as the association of SdFFF with structural investigations to better understand the specific mechanisms of amylolysis or starch granule structure.  相似文献   

17.
Sedimentation field-flow fractionation–inductively coupled plasma–mass spectrometry (SdFFF-ICP-MS) was successfully applied to investigate particle size distribution of titanium dioxide (TiO2) in sunscreen samples after hexane extraction to remove organic components from the samples. Three brands of sunscreen products of various sun protection factor (SPF) value were used as samples. Different particle size distribution profiles were observed for sunscreen samples of various brands and SPF values; however, the particle size distributions of titanium dioxide in most sunscreen samples investigated in this work were larger than 100 nm. The titanium dioxide concentrations were higher for the products of higher SPF values. By comparing the results obtained from online SdFFF-ICP-MS and those from the off-line ICP-MS determination of titanium after acid digestion, ICP-MS was found to effectively atomize and ionize the titanium dioxide particle without the need for acid digestion of the samples. Therefore, the online coupling between SdFFF and ICP-MS could be effectively used to provide quantitative information of titanium dioxide concentrations across particle size distribution profiles.  相似文献   

18.
 A method for characterizing the particle size and size distribution of multi-sized polymer lattices was developed by combining quasielastic light scattering (QELS) with a centrifuge. Lattices were first fractionated by centrifugation and the different populations of particles were separated in successive steps. The size of these particles was measured by QELS, and the mass fraction of the particles was determined gravimetrically. The particle size and size distribution of several blends of monodisperse lattices and two industrial multi-sized lattices have been measured by this method. The results show that the particle sizes obtained using this method are in good agreement with the expected particle diameters, and that the relative amounts of the different groups of particles in the blends can be accurately determined. The efficiency of centrifuge-QELS was also confirmed by comparison with other techniques such as transmission electron microscopy (TEM), QELS, field-flow fractionation (FFF) and capillary hydrodynamic fractionation (CHDF). However, this method is not suited for the analysis of continuous, broad distributions or mixtures with a high number of different populations. It is better suited for distributions with a small number of families of particles, and then can be used for preparative propose on a laboratory scale. Received: 9 October 1996 Accepted: 7 July 1997  相似文献   

19.
This work represents a first systematic approach to the size-based elemental quantification and size estimation of metal(loid) oxide nanoparticles such as silica (SiO2) in a real food matrix using asymmetric flow field-flow fractionation coupled online with inductively coupled plasma mass spectrometry (ICP-MS) and multi-angle light scattering (MALS) and offline with transmission electron microscopy (TEM) with energy-dispersive X-ray analysis (EDAX). Coffee creamer was selected as the model sample since it is known to contain silica as well as metal oxides such as titania at the milligramme per kilogramme levels. Optimisation of sample preparation conditions such as matrix-to-solvent ratio, defatting with organic solvents and sonication time that may affect nanoparticle size and size distribution in suspensions was investigated. Special attention was paid to the selection of conditions that minimise particle transformation during sample preparation and analysis. The coffee creamer matrix components were found to stabilise food grade SiO2 particles in comparison with water suspensions whilst no significant effect of defatting using hexane was found. The use of sample preparation procedures that mimic food cooking in real life was also investigated regarding their effect on particle size and particle size distribution of silica nanoparticles in the investigated food matrix; no significant effect of the water temperature ranging from ambient temperature to 60 °C was observed. Field-flow fractionation coupled to inductively coupled plasma-mass spectrometry (FFF-ICP-MS) analysis of extracts of both unspiked coffee creamer and coffee creamer spiked with food grade silicon dioxide, using different approaches for size estimation, enabled determination of SiO2 size-based speciation. Element-specific detection by ICP-MS and post-FFF calibration with elemental calibration standards was used to determine the elemental composition of size fractions separated online by FFF. Quantitative data on mass balance is provided for the size-based speciation of the investigated inorganic nano-objects in the complex matrix. The combination of FFF with offline fractionation by filtration and with detection by ICP-MS and TEM/EDAX has been proven essential to provide reliable information of nanoparticle size in the complex food matrix.
Figure
Characterisation of silica nanoparticles in a coffee creamer matrix using FFF-based methodology  相似文献   

20.
Inorganic mass spectrometry techniques may offer great potential for the characterisation at the nanoscale, because they provide unique elemental information of great value for a better understanding of processes occurring at nanometre-length dimensions. Two main groups of techniques are reviewed: those allowing direct solid analysis with spatial resolution capabilities, i.e. lateral (imaging) and/or in-depth profile, and those for the analysis of liquids containing colloids. In this context, the present capabilities of widespread elemental mass spectrometry techniques such as laser ablation coupled with inductively coupled plasma mass spectrometry (ICP-MS), glow discharge mass spectrometry and secondary ion/neutral mass spectrometry are described and compared through selected examples from various scientific fields. On the other hand, approaches for the characterisation (i.e. size, composition, presence of impurities, etc.) of colloidal solutions containing nanoparticles by the well-established ICP-MS technique are described. In this latter case, the capabilities derived from the on-line coupling of separation techniques such as field-flow fractionation and liquid chromatography with ICP-MS are also assessed. Finally, appealing trends using ICP-MS for bioassays with biomolecules labelled with nanoparticles are delineated.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号