首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Polar betacyanin pigments together with betaxanthins from ripe cactus fruits of Hylocereus polyrhizus (Cactaceae) were fractionated by means of preparative ion-pair high-speed countercurrent chromatography (IP-HSCCC) also using the elutionextrusion (EE) approach for a complete pigment recovery. HSCCC separations were operated in the classical ‘head-to-tail’ mode with an aqueous mobile phase. Different CCC solvent systems were evaluated in respect of influence and effectiveness of fractionation capabilities to separate the occurring pigment profile of H. polyrhizus. For that reason, the additions of two different volatile ion-pair forming perfluorinated carboxylic acids (PFCA) were investigated. For a direct comparison, five samples of Hylocereus pigment extract were run on preparative scale (900 mg) in 1-butanol–acetonitrile–aqueous TFA 0.7% (5:1:6, v/v/v) and the modified systems tert.-butyl methyl ether–1-butanol–acetonitrile–aqueous PFCA (2:2:1:5, v/v/v/v) using 0.7% and 1.0% trifluoroacetic acid (TFA) or heptafluorobutyric acid (HFBA) in the aqueous phase, respectively. The chemical affinity to the organic stationary CCC solvent phases and in consequence the retention of these highly polar betalain pigments was significantly increased by the use of the more lipophilic fluorinated ion-pair reagent HFBA instead of TFA. The HFBA additions separated more effectively the typical cacti pigments phyllocactin and hylocerenin from betanin as well as their iso-forms. Unfortunately, similar KD ratios and selectivity factors α around 1.0–1.1 in all tested solvent systems proved that the corresponding diastereomers, 15S-type pigments cannot be resolved from the 15R-epimers (iso-forms). Surprisingly, additions of the stronger ion-pair reagent (HFBA) resulted in a partial separation of hylocerenin from phyllocactin which were not resolved in the other solvent systems. The pigments were detected by means of HPLC-DAD and HPLC-electrospray ionization–MS using also authentic reference materials.  相似文献   

2.
3.
Densities ρ of the ternary system 1-butanol + hexylamine + n-heptane and binaries: 1-butanol + hexylamine and hexylamine + n-heptane within the temperature range (288.15–323.15 K) and atmospheric pressure are reported. Excess molar volumes VE were calculated from the density data and fitted by the Redlich–Kister and Nagata and Tamura equations. The results are analyzed in terms of the molecular interactions between the components of mixtures.  相似文献   

4.
An in-vial liquid–liquid microextraction method was developed for the selective extraction of the phenolic acids (caffeic, gallic, cinnamic, ferulic, chlorogenic, syringic, vanillic, benzoic, p-hydroxybenzoic, 2,4-dihydroxybenzoic, o-coumaric, m-coumaric and p-coumaric) in vegetable oil samples. The optimised extraction conditions for 20 g sample were: volume of diluent (n-hexane), 2 mL; extractant, methanol: 5 mM sodium hydroxide (60:40; v/v); volume of extractant, 300 μL (twice); vortex, 1 min; centrifugation, 5 min. Recoveries for the studied phenolic acids were 80.1–119.5%. The simultaneous determination of the phenolic acid extracts was investigated by capillary electrophoresis (CE). Separations were carried out on a bare fused-silica capillary (50 μm i.d. × 40 cm length) involving 25 mM sodium tetraborate (pH 9.15) and 5% methanol as CE background electrolyte in the normal polarity mode, voltage of 30 kV, temperature of 25 °C, injection time of 4 s (50 mbar) and electropherograms were recorded at 200 nm. The phenolic acids were successfully separated in less than 10 min. The validated in-vial LLME-CE method was applied to the determination of phenolic acids in vegetable oil samples (extra virgin olive oil, virgin olive oil, pure olive oil, walnut oil and grapeseed oil). The developed method shows significant advantages over the current methods as lengthy evaporation step is not required.  相似文献   

5.
High-speed counter-current chromatography (HSCCC) with a two-phase solvent system (hexane–ethanol–acetonitrile–water 10:8:1:1, v/v) was applied to examine the leaves of Hortia oreadica, which afforded the known limonoid guyanin (1), the alkaloids rutaecarpin (2) and dictamnine (6), the dihydrocinnamic acid derivatives methyl 5,7-dimethoxy-2,2-dimethyl-2H-1-benzopyran-6-propanoate (3), 5,8-dimethoxy-2,2-dimethyl-2H-1-benzopyran-6-propanoic acid (4), together with the new E-3,4-dimethoxy-α(3-hydroxy-4-carbomethoxyphenyl)cinnamic acid (5). The recovery of compounds 1–6 was determined by comparison with LC-atmospheric pressure chemical ionization MS/MS data: 66.2%, 93.1%, 102.5%, 101.2%, 99.0% and 84.9%, respectively. Compound 3 showed IC50 of 23.6 μM against Plasmodium falciparum and 15.6 μM against Trypanosoma brucei rhodesienses and was not toxic to KB cells (IC50 > 100 μM).  相似文献   

6.
Vapour–liquid equilibria and densities for the ternary system chloroform + tetrahydrofuran + cyclohexane and for the binary mixtures containing chloroform have been determined at 298.15 K. Vapour–liquid equilibrium data have been collected by head-space gas-chromatographic analysis of the vapour phase directly withdrawn from an equilibration apparatus. Density measurements have been carried out by means of a vibrating tube densimeter. Molar excess Gibbs energies GE and volumes VE, as well as activity coefficients and apparent molar volumes of the components, have been obtained from the measured quantities and discussed. The binary chloroform + tetrahydrofuran displays negative deviations from ideality, while chloroform + cyclohexane positive deviations, for both volume and Gibbs energy. The GE's and VE's for the ternary system are positive in the region rich in cyclohexane while negative in the region rich in chloroform + tetrahydrofuran. This indicates that hydrogen bonding between chloroform and tetrahydrofuran molecules produces negative values of GE and VE and strongly influences the behaviour of the ternary system.  相似文献   

7.
A series of poly(aryl ether benzimidazole) copolymers bearing different aryl ether linkage contents were synthesized by condensation polymerization in polyphosphoric acid (PPA) by varying the feed ratio of 4,4′-dicarboxydiphenyl ether (DCPE) to terephthalic acid (TA). As the ether unit content in the copolymer increased, the solubility of the copolymer in PPA and N,N′-dimethylacetamide/LiCl improved. For example 3–7 wt.% DMAc solution containing 2 wt.% of LiCl could be prepared from the copolymers. XRD studies revealed that the incorporation of flexible aryl ether linkages increased the chain d-spacings of the polymer backbones and decreased the crystallinity of the copolymers. Still, these copolymers having ether linkages showed reasonably good thermal/mechanical stability and high proton conductivity. For example, the copolymer with 30 mol% ether linkage had a tensile strength of 43 MPa (at 26 °C and 40% relative humidity) at an acid doping level of 7.5 mol H3PO4 and a proton conductivity of 0.098 S cm−1 (at 180 °C and 0% relative humidity) at an acid doping level of 6.6 mol H3PO4.  相似文献   

8.
A series of oxovanadium(IV) complexes: TpVO(pzH)(2,4-Cl–C6H3–OCH2COO) (1), TpVO(pzH)(C6H5–OCH2COO) (2), TpVO(pzH)(p-Cl–C6H4–COO) (3), TpVO(pzH)(3,5-NO2–C6H3–COO) (4), Tp∗VO(pzH∗)(p-Cl–C6H4–COO) (5) and Tp∗VO(pzH∗)(p-Cl–C6H4–COO) · CH3OH (6) (Tp = hydrotris(pyrazolyl)borate, pzH = pyrazole, Tp∗ = hydrotris(3,5-dimethylpyrazolyl)borate, pzH∗ = 3,5-dimethylpyrazole) were synthesized and their crystal structures were determined by X-ray diffraction. In all the complexes, the vanadium ions are in a distorted-octahedral environment with a N4O2 donor set. Hydrogen bonding interaction exists in each complex. Complexes 1 and 2 are hydrogen-bonded dimers. Dimeric units of 2 are connected to one another via weak inter-molecular C–H···O interactions to form a 2D network on the bc-face. In 36 there exist intramolecular N–H···O hydrogen bonds between the neutral pyrazole/3,5-dimethylpyrazole and the uncoordinated carboxyl oxygen atom. In addition, the catalytic activity of complex 2 in a bromination reaction in phosphate buffer with phenol red as a trap was evaluated by UV–Vis spectroscopy. Furthermore, the elemental analyses, IR spectra and thermal stabilities were recorded.  相似文献   

9.
A biosensor based on the ionic liquid, 1-n-butyl-3-methylimidazolium hexafluorophosphate containing dispersed iridium nanoparticles (Ir-BMI.PF6) and polyphenol oxidase was constructed. This enzyme was obtained from the sugar apple (Annona squamosa), immobilized in chitosan ionically crosslinked with oxalate. The biosensor was used for determination of chlorogenic acid by square wave voltammetry. The polyphenol oxidase catalyzes the oxidation of chlorogenic acid to the corresponding o-quinone, which is electrochemically reduced back to this substance at +0.25 V vs. Ag/AgCl. Under optimized operational conditions the chlorogenic acid concentration was linear in the range of 3.48 × 10−6 to 4.95 × 10−5 mol L−1 with a detection limit of 9.15 × 10−7 mol L−1. The biosensor was applied in the determination of chlorogenic acid in organic and decaffeinated coffee and the results compared with those obtained using the capillary electrophoresis method. The recovery study for chlorogenic acid in these samples gave values of 93.2-105.7%.  相似文献   

10.
This paper describes a simultaneously performed two-/three-phase hollow-fiber-based liquid-phase microextraction (HF-LPME) method for the determination of aromatic amines with a wide range of pKa (−4.25 to 4.6) and log KOW (0.9–2.8) values in environmental water samples. Analytes including aniline, 4-nitroaniline, 2,4-dinitroaniline and dicloran were extracted from basic aqueous samples (donor phase, DP) into the microliter volume of organic membrane phase impregnated into the pores of the polypropylene hollow fiber wall, then back extracted into the acidified aqueous solution (acceptor phase, AP) filling in the lumen of the hollow fiber. The mass transfer of the analytes from the donor phase through the organic membrane phase into acceptor phase was driven by both the counter-coupled transport of hydrogen ions and the pH gradient. Afterwards, the hollow fiber was eluted with 50 μL methanol to capture the analytes from both the organic membrane and the acceptor phase. Factors relevant to the enrichment factors (EFs) were investigated. Under the optimized condition (DP: 100 mL of 0.1 M NaOH with 2 M Na2SO4; organic phase: di-n-hexyl with 8% trioctylphosphine oxide (TOPO); AP: 10 μL of 8 M HCl; extraction time of 80 min), the obtained EFs were 405–2000, dynamic linear ranges were 5–200 μg/L (R > 0.9976), and limits of detection were 0.5–1.5 μg/L. The presence of humic acid (0–25 mg/L dissolved organic carbon) had no significant effect on the extraction efficiency. The proposed procedure worked very well for real environmental water samples with microgram per liter level of analytes, and good spike recoveries (80–103%) were obtained.  相似文献   

11.
Porous layer open tubular (PLOT) polystyrene divinylbenzene columns have been used for separating intact proteins with gradient elution. The 10 μm I.D. × 3 m columns were easily coupled to standard liquid chromatography–mass spectrometry (LC–MS) instrumentation with commercially available fittings. Standard proteins separated on PLOT columns appeared as narrow and symmetrical peaks with good resolution. Average peak width increased linearly with gradient time (tG) from 0.14 to 0.33 min (tG 20 and 120 min, respectively) using a 3 m column. With shorter columns, peak widths were larger and increased more steeply with gradient time. Theoretical peak capacity (nc) increased with column length (tested up to 3 m). The nc increased with tG until a plateau was reached. The highest peak capacity achieved (nc = 185) was obtained with a 3 m column, where a plateau was reached with tG 90 min. The within- and between column retention time repeatabilities were below 0.6% and below 2.5% (relative standard deviation, RSD), respectively. The carry-over following injection of 0.5 ng per protein was less than 1.1%. The retention time dependence on column temperature was investigated in the range 20–50 °C. Proteins in a skimmed milk sample were separated using the method.  相似文献   

12.
The performance of type-I high-speed counter-current chromatography was evaluated by changing the column inclination against the rotating centrifugal force field. The separations were performed with two different solvent systems composed of 1-butanol–acetic acid–water (4.75:0.25:5, v/v) (BAW) and hexane–ethyl acetate–methanol–0.1 M HCl (1:1:1:1, v/v) (HEMW) using dipeptides and DNP-amino acid as test samples, respectively. A set of short coiled columns connected in series is mounted around the holder hub in two different ways: in the parallel orientation, all column units are arranged in parallel to each other and mounted on the holder at various angles against the horizontal plane. In the zigzag configuration, the neighboring units of the same column are mounted symmetrically forming various angles apart. In the parallel configuration, for both the BAW and HEMW systems, Sf (the retention of stationary phase) first increased as the column angle decreased from 90° to 60° and then decreased, as the column angle further decreased from 60° to 0°, while Rs (peak resolution) continually declined over the entire column angle range from 90° to 0°. But, for both solvent systems, with the zigzag configuration, retention of stationary phase and resolution both decreased as the column angle decreased from 90° to 0°. In general, Sf and Rs for separation of dipeptides in the BAW system, from 90° to 15°, is better for the parallel orientation than for the zigzag configuration. However, at 0°, Sf and Rs are better for the zigzag orientation. In the DNP-amino acid separation with the HEMW system, retention of the stationary phase and Rs for the parallel orientation is better than that for the zigzag orientation from 90° to 30°, whereas from 30° to 0° the results are opposite. Over all results of our studies revealed that the formally used column orientation [5] at 90° inclination yields the highest peak resolution in both solvent systems.  相似文献   

13.
Two rapid, sensitive and quantitative methods for the determination of the cysteine and cystine ratio in complex defined media feedstock using monolithic reversed-phase liquid chromatography (RPLC) and RPLC–MS are presented. Cysteine is pre-derivatised with purified 2-chloro-1-methylquinolinium tetrafluoroborate (CMQT) and separated from other derivatisation products on a narrow-bore 50 mm × 2 mm I.D. monolithic C18 column with UV detection at 355 nm. For reversed-phase LC (RPLC) the separation is carried out isocratically using a mobile phase of 50 mM trichloroacetic acid (TCA) adjusted to pH 2.5 with lithium hydroxide (LiOH) and acetonitrile (83:14) pumped at 1.5 mL/min with an elevated column temperature. For RPLC–MS an ammonium acetate and acetonitrile gradient method was developed with a reduced flow rate of 0.3 mL/min. The treatment of the samples consisted of dividing them into two aliquots, the first aliquot is analysed for cysteine and the second aliquot is analysed for cystine after its quantitative reduction to cysteine using tris(2-carboxyethyl)phosphine (TCEP). Both methods are linear, with R2 > 0.999 for 0.25–500 μM for cysteine and 0.25–250 μM for cystine using the LC–UV method, sensitive, with detection limit of 36 nM for cysteine, and precise, with ≤1.1% RSD for both retention time and peak area (n = 6). Samples (n = 31) of an industry standard and supplied chemically defined media feedstock were analysed, finding cysteine ranging from 1.56 to 2.26 μg/mL and cystine from 1062.02 to 1348.13 μg/mL.  相似文献   

14.
Luminescence quenching of a novel long lived Eu(III)–pyridine-2,6-dicarboxylic acid probe of 1:2 stoichiometric ratio has been studied in 0.10 volume fraction ethanol–water mixture at pH 7.5 (HEPES buffer) in the presence of the organophosphorus pesticides chlorfenvinphos (P1), malathion (P2), azinphos (P3), and paraxon ethyl (P4). The luminescence intensity of Eu(III)–(PDCA)2 probe decreases as the concentration of the pesticide increases. It was observed that the quenching due to P3 and P4 proceeds via both diffusional and static quenching processes. Direct methods for the determination of the pesticides under investigation have been developed using the luminescence quenching of Eu(III)–pyridine-2,6-dicarboxylic acid probe in solution. The linear range for determination of the selected pesticides is 1.0–35.0 μM. The detection limits were 0.24–0.55 μM for P3, P4, and P1 and 2.5 μM for P2, respectively. The binding constants (K), and thermodynamic parameters of the OPs with Eu(III)–(PDCA)2 were evaluated. Positive and negative values of entropy (ΔS) and enthalpy (ΔH) changes for Eu(III)–(PDCA)2–P1 ternary complex were calculated. As the waters in this study do not contain the above mentioned OPs over the limit detectable by the method, a recovery study was carried out after the addition of the adequate amounts of the organophosphorus pesticides under investigation.  相似文献   

15.
Capillary affinity electrophoresis (CAE) and quantum mechanical density functional theory (DFT) have been applied to the investigation of interactions of valinomycin (Val), a macrocyclic dodecadepsipeptide antibiotic ionophore, with lithium cation Li+. Firstly, from the dependence of effective electrophoretic mobility of Val on the Li+ ion concentration in the background electrolyte (BGE) (methanolic solution of 50 mM chloroacetic acid, 25 mM Tris, pHMeOH 7.8, 0–40 mM LiCl), the apparent binding (stability) constant (Kb) of Val–Li+ complex in methanol was evaluated as log Kb = 1.50 ± 0.24. The employed CAE method include correction of the effective mobilities measured at ambient temperature, at different input power (Joule heating) and at variable ionic strength of the BGEs to the mobilities related to the reference temperature 25 °C and to the constant ionic strength 25 mM. Secondly, using DFT calculations, the most probable structures of the non-hydrated Val–Li+ and hydrated Val–Li+·3H2O complex species were predicted.  相似文献   

16.
The vapour pressures of the binary systems 1,2-dichloroethane + cyclohexanone, chloroform + cyclopentanone and chloroform + cyclohexanone mixtures were measured at temperatures between 298.15 and 318.15 K. The vapour pressures vs. liquid phase composition data for three isotherms have been used to calculate the activity coefficients of the two components and the excess molar Gibbs energies, GE, for these mixtures, using Barker's method. Redlich–Kister, Wilson, NRTL and UNIQUAC equations, taking into account the vapour phase imperfection in terms of the 2-nd virial coefficient, have represented the GE values. No significant difference between GE values obtained with these equations has been observed. Our data on vapour–liquid equilibria (VLE) and excess properties of the studied systems are examined in terms of the DISQUAC and modified UNIFAC (Dortmund) predictive group contributions models.  相似文献   

17.
The development of a method for the separation of 2′-2′-difluorodeoxycytidine (gemcitabine, dFdC), 2′-2′-difluorodeoxyuridine (dFdU) and their mono-, di- and triphosphates using a porous graphitic carbon column (Hypercarb), without ion-pairing agent, is described. The retention of dFdC and dFdU could be controlled with an organic modifier (acetonitrile, CH3CN) and the retention of the anionic nucleotides with an eluting ion (bicarbonate). Separation of all analytes was achieved using a 0–25 mM ammonium bicarbonate gradient in CH3CN–H2O (15:85, v/v). Under these conditions, however, very long re-equilibration times were required. Injection of an acidic solution (100 μL 10% formic acid in H2O, v/v; 2.65 M) after running a gradient directly restored the separation capabilities of the column. Still, separation between the analytes slowly deteriorated over a period of months. These problems were solved by preconditioning the column with a pH buffered hydrogen peroxide (H2O2) solution (0.05% H2O2 in CH3CN–H2O (15:85, v/v), pH 4) before starting an analytical run. The oxidation of the stationary phase with H2O2 prevented its slow reduction, which most likely caused the decreasing retention times. The analytes were detected using tandem mass spectrometry.  相似文献   

18.
Densities ρ of the ternary system (ethanol + chloroform + benzene) and binaries (ethanol + chloroform) and (chloroform + benzene), have been measured at six temperatures (288.15, 293.15, 298.15, 303.15, 308.15, 313.15) K and pressure 101.33 kPa with an Anton Paar DMA 5000 digital vibrating tube densimeter. Excess molar volumes VE were calculated from these densities data and fitted by the polynomial Redlich–Kister (for binary data) and Nagata and Tamura (for ternary data) equations. Radojkovi? et al. equation was used for the prediction of the VE of ternary data. The obtained results have been explained in terms of different effects between molecules of present species, taking into consideration influence of temperature on them.  相似文献   

19.
The development and performance evaluation of an analytical method dedicated to the comprehensive determination of the most relevant antioxidants and their metabolites in aqueous environmental samples is presented. This was achieved by a miniaturised solid-phase extraction (SPE) with 10 mg Oasis HLB cartridges, which allow to achieve a concentration factor of 200, reducing organic solvent wastes (1 mL of ethyl acetate suffices for complete elution) and SPE costs and eliminating the need for solvent evaporation that otherwise compromises the recoveries of butylated hydroxytoluene (BHT) and 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q). Analytes were then determined by gas chromatography–mass spectrometry (GC–MS) after derivatisation with N-methyl-N-(tert-butyldimethylsilyl)-trifluoroacetamide (MTBSTFA) in a single run. BHT-d7 and n-propyl-paraben-d4 (PrP-d4) were used as surrogate internal standards. These surrogates allowed obtaining relative recoveries in the 80–110% range for all analytes even with complex wastewater samples and LODs at the 2–44 ng L−1 level taking into account blank issues often associated to antioxidants analysis. The method was applied to sewage and river waters, showing that the seven analytes could be detected in raw wastewater. BHT and BHT-Q were the most concentrated species in that type of sample (in the 275–871 ng L−1 range). On the other hand two metabolites of BHT, 3,5-di-tert-butyl-4-hydroxybenzaldehyde (BHT-CHO) and 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) appeared to be the most ubiquitous species, being found in all samples in the 10–150 ng L−1 concentration range.  相似文献   

20.
By using ionic liquid as membrane liquid and tri-n-octylphosphine oxide (TOPO) as additive, hollow fiber supported liquid phase microextraction (HF-LPME) was developed for the determination of five sulfonamides in environmental water samples by high-performance liquid chromatography with ultraviolet detection The extraction solvent and the parameters affecting the extraction enrichment factor such as the type and amount of carrier, pH and volume ratio of donor phase and acceptor phase, extraction time, salt-out effect and matrix effect were optimized. Under the optimal extraction conditions (organic liquid membrane phase: [C8MIM][PF6] with 14% TOPO (w/v); donor phase: 4 mL, pH 4.5 KH2PO4 with 2 M Na2SO4; acceptor phase: 25 μL, pH 13 NaOH; extraction time: 8 h), low detection limits (0.1–0.4 μg/L, RSD ≤ 5%) and good linear range (1–2000 ng/mL, R2 ≥ 0.999) were obtained for all the analytes. The presence of humic acid (0–25 mg/L dissolved organic carbon) and bovine serum albumin (0–100 μg/mL) had no significant effect on the extraction efficiency. Good spike recoveries over the range of 82.2–103.2% were obtained when applying the proposed method on five real environmental water samples. These results indicated that this present method was very sensitive and reliable with good repeatabilities and excellent clean-up in water samples. The proposed method confirmed hollow fiber supported ionic liquid membrane based LPME to be robust to monitoring trace levels of sulfadiazine, sulfamerazine, sulfamethazine, sulfadimethoxine and sulfamethoxazole in aqueous samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号