首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
Yang X  Yuan H  Wang C  Zhao S  Xiao D  Choi MM 《Electrophoresis》2007,28(17):3105-3114
A highly sensitive in-column fiber-optic LIF detector for CE has been constructed and evaluated. In this detection system, a 457-nm diode-pumped solid-state blue laser was used as the excitation light source and an optical fiber (40 mum od) was used to transmit the excitation light. One end of the optical fiber was inserted into the separation capillary and was in situ positioned at the detection window. The other end of the fiber was protruded from the capillary to capture the excitation light beam from the blue laser. Fluorescence emission was collected by a 40 x microscope objective, focused on a spatial filter, and passed through a yellow color filter before reaching the photomultiplier tube. The present CE-fluorescence detection is a simple and compact optical system. It reduces the laser scattering effect from the capillary and fiber as compared to the conventional LIF detection for CE. Its utility was successfully demonstrated by the separation and determination of D-penicillamine labeled with naphthalene-2,3-dicarboxaldehyde. The detection limit was 0.8 nM (S/N = 3). The present detection scheme has been proven to be attractive for sensitive fluorescence detection for CE.  相似文献   

2.
Yang X  Huo F  Yuan H  Zhang B  Xiao D  Choi MM 《Electrophoresis》2011,32(2):268-274
This paper reports the enhancement of sensitivity of detection for in‐column fiber optic‐induced fluorescence detection system in CE by tapered optical fiber (TOF). Two types of optical fiber, TOF and conventional cylindrical optical fiber (COF), were employed to construct the CE (TOF‐CE and COF‐CE) and were compared for sensitivity to riboflavin (RF). The fluorescence intensities from a RF sample with excitation light sources and fibers at various coupling angles were investigated. The fluorescence signal from TOF‐CE was ca. ten times that of COF‐CE. In addition, the detection performance of four excitation light source‐fiber configurations including Laser‐TOF, Laser‐COF, LED‐TOF, and LED‐COF were compared. The LODs for RF were 0.21, 0.82, 0.80, and 7.5 nM, respectively, for the four excitation light source–fiber configurations. The results demonstrate that the sensitivity obtained by LED‐TOF is close to that of Laser‐COF. Both Laser‐TOF and LED‐TOF can greatly improve the sensitivity of detection in CE. TOF has the major attribute of collecting and focusing the excitation light intensity. Thus, the sensitivity obtained by LED‐TOF without focusing lens is just same as that of LED‐COF with a focusing lens. This demonstrates that the CE system can be further simplified by eliminating the focusing lens for excitation light. LED‐TOF‐CE and LED‐COF‐CE system were applied to the separation and determination of RF in real sample (green tea), respectively. The tapered fiber optic‐induced fluorescence detection system in CE is an ideal tool for trace analysis.  相似文献   

3.
A new detector, capillary coupled with optical fiber LED‐induced fluorescence detector (CCOF‐LED‐IFD, using CCOF for short), is introduced for CE. The strategy of the present work was that the optical fiber and separation capillary were, in the parallel direction, fastened in a fixation capillary with larger inner diameter. By employing larger inner diameter, the fixation capillary allowed the large diameter of the optical fiber to be inserted into it. By transmitting an enhanced excitation light through the optical fiber, the detection sensitivity was improved. The advantages of the CCOF‐CE system were validated by the detection of riboflavin, and the results were compared to those obtained by the in‐capillary common optical fiber LED‐induced fluorescence detector (IC‐COF‐LED‐IFD, using COF for short). The LODs of CCOF‐CE and COF‐CE were 0.29 nM and 11.0 nM (S/N = 3), respectively. The intraday (n = 6) repeatability and interday (n = 6) reproducibility of migration time and corresponding peak area for both types of CE were all less than 1.10 and 3.30%, respectively. The accuracy of the proposed method was judged by employing standard addition method, and recoveries obtained were in the range of 98.0–102.4%. The results indicated that the sensitivity of the proposed system was largely improved, and that its reproducibility and accuracy were satisfactory. The proposed system was successfully applied to separate and determine riboflavin in real sample.  相似文献   

4.
A novel fluorescence detection system for CE was described and evaluated. Two miniature laser pointers were used as the excitation source. A Y‐style optical fiber was used to transmit the excitation light and a four‐branch optical fiber was used to collect the fluorescence. The optical fiber and optical filter were imported into a photomultiplier tube without any extra fixing device. A simplified PDMS detection cell was designed with guide channels through which the optical fibers were easily aligned to the detection window of separation capillary. According to different requirements, laser pointers and different filters were selected by simple switching and replacement. The fluorescence from four different directions was collected at the same detecting point. Thus, the sensitivity was enhanced without peak broadening. The fluorescence detection system was simple, compact, low‐cost, and highly sensitive, with its functionality demonstrated by the separation and determination of red dyes and fluorescent whitening agents. The detection limit of rhodamine 6G was 7.7 nM (S/N = 3). The system was further applied to determine illegal food dyes. The CE system is potentially eligible for food safety analysis.  相似文献   

5.
Huo F  Guijt R  Xiao D  Breadmore MC 《The Analyst》2011,136(11):2234-2241
A simple and novel two-colour fluorescence detector for capillary electrophoresis was created using a single bi-colour light emitting diode (LED), multi-band pass excitation and emission filters and a single detector. Excitation light from a blue/red (470/635 nm) bi-colour LED was filtered through a 390/482/563/640 nm multi-band bandpass filter, with emitted light filtered through a 446/523/600/677 nm multi-band bandpass filter before being detected using a photon counting detector. Sequential pulsing of the blue/red LED and deconvolution of the collected fluorescence data allowed extracted electropherograms to be obtained corresponding to excitation with the blue and red LEDs. Optimisation of the pulsed LED conditions revealed an optimum LED on-time of 50 ms, off-time of 30 ms with a pulsed current of 40 mA, giving an effective data acquisition rate of 6.25 Hz. The characteristics of this system were validated by the simultaneous separation and determination of six fluorescent dyes: fluorescein, FITC, coumarin 334, dibromo(R)fluorescein (Ex/Em 470/525 nm), and Cy 5 and the Agilent Bioanalyser DNA dye (Ex/Em 635/670 nm). Under optimum conditions, the detection limits for FITC, fluorescein and Cy 5 were 69 nM, 42 nM and 289 nM (S/N = 3), respectively. These were lower than those obtained with continuous operation of the individual wavelengths at a constant current of 20 mA, but were slightly higher than those obtained using dedicated single wavelength filter combinations designed specifically for use with these fluorophores. The intraday repeatability (n = 6) of migration times was less than 1.0% and less than 3.4% for peak areas, while interday (n = 3) migration time and peak area reproducibility were less than 0.9% and 3.6%, respectively. This simple detector is capable of performing quantitative two-wavelength excitation without the need for complex optics and light source configurations.  相似文献   

6.
《Electrophoresis》2017,38(3-4):452-459
A new detector, silvering detection window and in‐capillary optical fiber light‐emitting diode‐induced fluorescence detector (SDW‐ICOF‐LED‐IFD), is introduced for capillary electrophoresis (CE). The strategy of the work was that half surface of the detection window was coated with silver mirror, which could reflect the undetected fluorescence to the photomultiplier tube to be detected, consequently enhancing the detection sensitivity. Sulfonamides (SAs) are important antibiotics that achieved great applications in many fields. However, they pose a serious threat on the environment and human health when they enter into the environment. The SDW‐ICOF‐LED‐IFD‐CE system was used to determine fluorescein isothiocyanate (FITC)‐labeled sulfadoxine (SDM), sulfaguanidine (SGD) and sulfamonomethoxine sodium (SMM‐Na) in environmental water. The detection results obtained by the SDW‐ICOF‐LED‐IFD‐CE system were compared to those acquired by the CE with in‐capillary optical fiber light‐emitting diode‐induced fluorescence detection (ICOF‐LED‐IFD‐CE). The limits of detection (LODs) of SDW‐ICOF‐LED‐IFD‐CE and ICOF‐LED‐IFD‐CE were 1.0–2.0 nM and 2.5–7.7 nM (S/N = 3), respectively. The intraday (n = 6) and interday (n = 6) precision of migration time and corresponding peak area for both types of CE were all less than 0.86% and 3.68%, respectively. The accuracy of the proposed method was judged by employing standard addition method, and recoveries obtained were in the range of 92.5–102.9%. The results indicated that the sensitivity of the SDW‐ICOF‐LED‐IFD‐CE system was improved, and that its reproducibility and accuracy were satisfactory. It was successfully applied to analyze SAs in environmental water.  相似文献   

7.
Yang B  Tian H  Xu J  Guan Y 《Talanta》2006,69(4):996-1000
An integrated light emitting diode (LED)-induced fluorescence detector was described and evaluated. The LED and its related components including lens and interference filter, the optical fiber used to collect fluorescence, and the capillary column are integrated into a substrate block, which eliminates the need of align procedure of the fiber and the capillary. Forty-fold enhancement of sensitivity was obtained compared with our previous work and the detection limit for fluorescein was 5 nM. Application of the detector for the analysis of FITC-labeled Ephedrine extract was demonstrated.  相似文献   

8.
Feng-Bo Yang 《Talanta》2009,78(3):1155-203
In this work, a simple and low-cost miniaturized light-emitting diode induced fluorescence (LED-IF) detector based on an orthogonal optical arrangement for capillary electrophoresis (CE) was developed, using a blue concave light-emitting diode (LED) as excitation source and a photodiode as photodetector. A lens obtained from a waste DVD-ROM was used to focus the LED light beam into an ∼80 μm spot. Fluorescence was collected with an ocular obtained from a pen microscope at 45° angle, and passed through a band-pass filter to a photodiode detector. The performance of the LED-IF detector was demonstrated in CE separations using sodium fluorescein and fluorescein isothiocyanate (FITC)-labeled amino acids as model samples. The limit of detection for sodium fluorescein was 0.92 μM with a signal-to-noise ratio (S/N) of 3. The total cost of the LED-IF detector was less than $ 50.  相似文献   

9.
Kuo JS  Kuyper CL  Allen PB  Fiorini GS  Chiu DT 《Electrophoresis》2004,25(21-22):3796-3804
With advances in III-V nitride manufacturing processes, high-power light-emitting diode (LED) chips in the blue and UV wavelengths are now commercially available at reasonable cost and can be used as excitation sources in optical sensing. We describe the use of these high-power blue and UV LEDs for sensitive fluorescence detection, including chip-based flow cytometry, capillary electrophoresis (CE), and single-molecule imaging. By using a blue LED with a focusable power of approximately 40 mW as the excitation source for fluorescent beads, we demonstrate a simple chip-based bead sorter capable of enriching the concentration of green fluorescent beads from 63% to 95%. In CE experiments, we show that a mixture of analyte solution containing 30 nM 6-carboxyrhodamine 6G and 10 nM fluorescein can be separated and detected with excellent signal-to-noise ratio (approximately 17 for 10 nM fluorescein) using the collimated emission from a blue LED; the estimated mass detection limit was approximately 200 zmol for fluorescein. We also demonstrated ultrasensitive fluorescence imaging of single rhodamine 123 molecules and individual lambda-DNA molecules. At a small fraction of the cost of an Ar+ laser, high-power blue and UV LEDs are effective alternatives for lasers and arc lamps in fluorescence applications that demand portability, low cost, and convenience.  相似文献   

10.
A combined detection system of simultaneous contactless conductometric and fluorescent detection for capillary electrophoresis (CE) has been designed and evaluated. The two processes share a common detection cell. A blue light-emitting diode (LED) was used as the excitation source and an optical fiber was used to collect the emitting fluorescence for fluorescent detection (FD). Inorganic ions, fluorescein isothiocyanate (FITC)-labeled amino acids and small molecule peptides were separated and detected by the combined detector, and the detection limits (LODs) of sub-microM level were achieved.  相似文献   

11.
Zhang T  Fang Q  Wang SL  Qin LF  Wang P  Wu ZY  Fang ZL 《Talanta》2005,68(1):19-24
The signal-to-noise level of light emitting diode (LED) fluorimetry using a liquid-core-waveguide (LCW)-based microfluidic capillary electrophoresis system was significantly enhanced using a synchronized dual wavelength modulation (SDWM) approach. A blue LED was used as excitation source and a red LED as reference source for background-noise compensation in a microfluidic capillary electrophoresis (CE) system. A Teflon AF-coated silica capillary served as both the separation channel and LCW for light transfer, and blue and red LEDs were used as excitation and reference sources, respectively, both radially illuminating the detection point of the separation channel. The two LEDs were synchronously modulated at the same frequency, but with 180°-phase shift, alternatingly driven by a same constant current source. The LCW transferred the fluorescence emission, as well as the excitation and reference lights that strayed through the optical system to a photomultiplier tube; a lock-in amplifier demodulated the combined signal, significantly reducing its noise level. To test the system, fluorescein isothiocyanate (FITC)-labeled amino acids were separated by capillary electrophoresis and detected by SDWM and single wavelength modulation, respectively. Five-fold improvement in S/N ratio was achieved by dual wavelength modulation, compared with single wavelength modulation; and over 100-fold improvement in S/N ratio was achieved compared with a similar LCW-CE system reported previously using non-modulated LED excitation. A detection limit (S/N = 3) of 10 nM FITC-labeled arginine was obtained in this work. The effects of modulation frequency on S/N level and on the rejection of noise caused by LED-driver current and detector were also studied.  相似文献   

12.
Xu J  Chen S  Xiong Y  Yang B  Guan Y 《Talanta》2008,75(4):885-889
A glycerol assisted light-emitting diode (LED)-induced fluorescence detector (IF) for capillary flow systems was constructed and evaluated. A blue LED was used as the excitation source, and optical fibers (OF) were used to transmit the excitation light and collect the fluorescence. A commercial available 5-port manifold was used as detection cell, where the capillary tube and the OF were fixed into the manifold. The precision of the holes on the manifold ensured a self-alignment of optical path. A refractive index matching fluid (RIMF)-glycerol was used to eliminate the interfaces between the OF and the LED, as well as between the fused silica capillary and the transmitting/collecting fiber. The enhancement of excitation light led to 2.8-folds improvement on the signal-to-noise ratio. The use of RIMF also eliminates focusing effect of the capillary wall and reduces both the excitation light directed to the detection cell and background signal, resulting in reduction in the fluorescence intensity and noise level. The intensity was reduced to 47-63% for laser and 60-77% for LED, respectively, for capillaries with i.d. from 50 to 250 microm; while the noise level was reduced to 1/3 when RIMF was used for both laser and LED on the tested capillaries. About 5.6-fold enhancement in signal-to-noise ratio was obtained in total. The detection limit of the LED-IF for fluorescein isothiocyanate (FITC) was 4 nM. Application of the LED-IF for the analysis of FITC-labeled amino acids by electrophoresis was demonstrated.  相似文献   

13.
包日煌  范清杰  宋珑  姚远  高卫平 《色谱》2015,33(2):201-206
应用毛细管电泳技术建立了人血清蛋白质毛细管电泳分析方法,对比了正常人与肝硬化患者血清蛋白质含量的差异。使用异硫氰酸荧光素(FITC)进行荧光标记,并考察光源与滤光片的波长、缓冲液的浓度、pH值、分离电压对分离效果的影响。建立了毛细管电泳-发光二极管诱导荧光法检测肝硬化患者血清及正常人血清蛋白质的方法;通过分离检测,获得了两者的蛋白质电泳谱图。经分析,在肝硬化患者的血清蛋白质中比在正常人的血清蛋白质中多检测到2个蛋白质峰,可能是和肝硬化发生相关的特异蛋白质;肝硬化患者与正常人的血清蛋白质电泳谱图的差异有统计学意义。该方法能实现人血清蛋白质的分离,可为临床诊断肝硬化做参考。  相似文献   

14.
Yang B  Guan Y 《Talanta》2003,59(3):509-514
A simple fluorescence detector for capillary electrophoresis (CE) using a blue light-emitting-diode (LED) as excitation source is constructed and evaluated. An optical fiber was used to collect the fluorescence, and a flat end of the fiber was modified to spherical end, resulting in 50% increase of efficiency over the flat end. A simple device for optical alignment of the fibers and capillary column was designed. The concentration and mass detection limits for fluorescein were 1.8×10−7 mol l−1 and 4.3 femol, respectively.  相似文献   

15.
Li HF  Lin JM  Su RG  Uchiyama K  Hobo T 《Electrophoresis》2004,25(12):1907-1915
A simple and easy-to-use integrated laser-induced fluorescence detector for microchip electrophoresis was constructed and evaluated. The fluid channels and optical fiber channels in the glass microchip were fabricated using standard photolithographic techniques and wet chemical etching. A 473 nm diode-pumped laser was used as the excitation source, and the collimation and collection optics and mirrors were discarded by using a multimode optical fiber to couple the excitation light straight into the microchannel and placing the microchip directly on the top of the photomultiplier tube. A combination of filter systems was incorporated into a poly(dimethylsiloxane) layer, which was reversibly sealed to the bottom of the microchip to eliminate the scattering excitation light reaching to the photomultiplier tube. Fluorescein/calcein samples were taken as model analytes to evaluate the performance with respect to design factors. The detection limits were 0.05 microM for fluorescein and 0.18 microM for calcein, respectively. The suitability of this simple detector for fluorescence detection was demonstrated by baseline separation of fluorescein isothiocyanate (FITC)-labeled arginine, phenylalanine, and glycine and FITC within 30 s at separation length of 3.8 cm and electrical field strength of 600 V/cm.  相似文献   

16.
A lamp‐based fluorescence detection (Flu) system for CE was extended with a wavelength‐resolved (WR) detector to allow recording of full protein emission spectra. WRFlu was achieved using a fluorescence cell that employs optical fibres to lead excitation light from a Xe‐Hg lamp to the capillary window and protein fluorescence emission to a spectrograph equipped with a CCD. A 280 nm band pass filter etc. together with a 300 nm short pass cut‐off filter was used for excitation. A capillary cartridge was modified to hold the detection cell in a commercial CE instrument enabling WRFlu in routine CE. The performance of the WRFlu detection was evaluated and optimised using lysozyme as model protein. Based on reference spectral data, a signal‐intensity adjustment was introduced to correct for transmission losses in the detector optics that occurred for lower protein emission wavelengths. CE‐WRFlu of lysozyme was performed using BGEs of 50 mM sodium phosphate (pH 6.5 or 3.0) and a charged‐polymer coated capillary. Using the 3‐D data set, signal averaging over time and emission‐wavelength intervals was carried out to improve the S/N of emission spectra and electropherograms. The detection limit for lysozyme was 21 nM, providing sufficient sensitivity to obtain spectral information on protein impurities.  相似文献   

17.
Wang SL  Fan XF  Xu ZR  Fang ZL 《Electrophoresis》2005,26(19):3602-3608
A miniaturized CE system has been developed for fast DNA separations with sensitive fluorimetric detection using a rectangle type light-emitting diode (LED). High sensitivity was achieved by combining liquid-core waveguide (LCW) and lock-in amplification techniques. A Teflon AF-coated silica capillary on a compact 6x3 cm baseplate served as both the separation channel for CE separation and as an LCW for light transmission of fluorescence emission to the detector. An electronically modulated LED illuminated transversely through a 0.2 mm aperture, the detection point on the LCW capillary without focusing, and fluorescence light was transmitted to the capillary outlet. To simplify the optics and enhance collection of light from the capillary outlet, an outlet reservoir was designed, with a light transmission window, positioned directly in front of a photomultiplier tube (PMT), separated only by a high pass filter. Automated sample introduction was achieved using a sequential injection system through a split-flow interface that allowed effective release of gas bubbles. In the separation of a phiX174 HaeIII DNA digest sample, using ethidium bromide as labeling dye, all 11 fragments of the sample were effectively resolved in 400 s, with an S/N ratio comparable to that of a CE system with more sophisticated LIF.  相似文献   

18.
A miniaturized post-column fluorimetric detection cell for capillary separation methods based on optical fibers and liquid core waveguides (LCWs) is described. The main part of the detection cell is a fused-silica capillary coated with Teflon AF serving as an LCW. The optical fibers are used both for coupling the excitation source with the detection domain in the LCW and for the axial fluorescence collection from the LCW end. The latter fiber is connected with a compact CCD spectrometer that serves for the rejection of the scattered excitation light and for the fluorescence signal detection. The proposed design offers a compact fluorescence detector for various microcolumn separation techniques without optical elements such as filters or objectives. Moreover, its construction and optical adjustment are very simple and the whole system is highly miniaturized. The function of the detection cell is demonstrated by CE of amino acids labelled by fluorescein-based tags. Separations of different standard amino acid mixtures and plasma samples are presented. The comparison of plasma amino acid levels of individuals being in good health with those of patients with inherited metabolic disorders is also shown.  相似文献   

19.
Yang F  Li XC  Zhang W  Pan JB  Chen ZG 《Talanta》2011,84(4):1155-1106
In this paper, a compact and inexpensive light emitting diode induced fluorescence (LED-IF) detector with simplified optical configuration was developed and assembled in an integrated microfluidic device for microscale electrophoresis. The facile detector mainly consisted of an LED, a focusing pinhole, an emission filter and a photodiode, and was encapsulated in the upper layer of an aluminum alloy device with two layers. At the bottom layer, integrated circuit (IC) was assembled to manipulate the voltage for sample injection and separation, LED emission and signal amplifying. A high-power LED with fan-shaped heat sink was used as excitation source. The excitation light was focused by a 1.1 mm diameter pinhole fabricated in a thin piece of silver foil, and the obtained sensitivity was about 3 times as high as that using electrode plate. Other important parameters including LED driven current, fluorescence collection angle and detection distance have also been investigated. Under optimal conditions, considerable high-response of 0.09 fmol and 0.18 fmol mass detection limits at 0.37 nL injection volume for sodium fluorescein (SF) and FITC was achieved, respectively. This device has been successfully employed to separate penicillamine (PA) enantiomers. Due to such significant features as low-cost, integration, miniaturization, and ease of commercialization, the presented microfluidic device may hold great promise for clinical diagnostics and bioanalytical applications.  相似文献   

20.
Xu J  Xiong Y  Chen S  Guan Y 《Talanta》2008,76(2):369-372
A light-emitting diode-induced fluorescence detector (LED-FD) for capillary electrophoresis was constructed and evaluated. A lamp LED with an enhanced emission spectrum and a band pass filter was used as the excitation light source. Refractive index matching fluid (RIMF) was used in the detection cell to reduce scattering light and the noise level. The limit of detection (LOD) for fluorescein was 1.5 nM (SNR=3). The system exhibited linear responses in the range of 1 x 10(-8) to 5 x 10(-6)M (R=0.999). Application of the lamp LED-FD for the analysis of FITC-labeled ephedra herb extract by capillary electrophoresis was demonstrated.  相似文献   