首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
基于碱性磷酸酶的去磷酸化作用,发展了一种可改善多磷酸化肽电喷雾质谱检测效果的技术。将β-酪蛋白酶解产物用TiO2柱富集后,用碱性磷酸酶进行处理,并经微柱液相色谱分离后采用串联质谱进行鉴定。通过谱图中存在相对分子质量与根据氨基酸序列预计的单磷酸化肽相差80 的色谱峰,可以证实样品中含有单磷酸化肽。此外,经碱性磷酸酶处理后的样品的色谱峰数目的增加,说明样品中可能存在多磷酸化肽段。通过控制去磷酸化反应的程度,使四磷酸化肽的部分磷酸基团被去除,从而可以推断其中3 个磷酸化位点可能处于氨基酸残基序列的第17、18和19位。  相似文献   

2.
We report the development of a new AP visible-wavelength MALDI-ion trap-MS instrument with significantly improved performance over our previously reported system (Int. J. Mass Spectrom. 315, 66–73 (2012)). A Nd:YAG pulsed laser emitting light at 532 nm was used to desorb and ionize oligosaccharides and peptides in transmission geometry through a glass slide. Limits of detection (LODs) achieved in MS mode correspond to picomole quantities of oligosaccharides and femtomole quantities of peptides. Tandem MS (MS/MS) experiments enabled identification of enzymatically digested proteins and oligosaccharides by comparison of MS/MS spectra with data found in protein and glycan databases. Moreover, the softness of ionization, LODs, and fragmentation spectra of biomolecules by AP visible-wavelength MALDI-MS were compared to those obtained by AP UV MALDI-MS using a Nd:YAG laser emitting light at 355 nm. AP visible-wavelength MALDI appears to be a softer ionization technique then AP UV MALDI for the analysis of sulfated peptides, while visible-wavelength MALDI-MS, MS/MS, and MS/MS/MS spectra of other biomolecules analyzed were mostly similar to those obtained by AP UV MALDI-MS. Therefore, the methodology presented will be useful for MS and MSn analyses of biomolecules at atmospheric pressure. Additionally, the AP visible-wavelength MALDI developed can be readily used for soft ionization of analytes on various mass spectrometers.
Figure
?  相似文献   

3.
We have developed a novel strategy to improve the efficiency of identification of multiply phosphorylated peptides isolated by hydroxy acid modified metal oxide chromatography (HAMMOC). This strategy consists of alkali‐induced chemical dephosphorylation (beta‐elimination reaction) of phosphopeptides isolated by HAMMOC prior to analysis by liquid chromatography/mass spectrometry (LC/MS). This approach identified 1.9‐fold more multiply phosphorylated peptides than the conventional approach without beta‐elimination from a digested mixture of three standard phosphoproteins. In addition, the accuracy of phosphorylation site determination in synthetic phosphopeptides was significantly improved. Finally, we applied this approach to a cell lysate. By combining this dephosphorylation approach with the conventional approach, we successfully identified 1649 unique phosphopeptides, including 325 multiply phosphorylated phosphopeptides, from 200 µg of cultured Arabidopsis cells. These results indicate that chemical dephosphorylation prior to LC/MS analysis increases the efficiency of identification of multiply phosphorylated peptides, as well as the accuracy of phosphorylation site determination. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
Despite recent advances in phosphoproteome research, detection and characterization of multi-phosphopeptides have remained a challenge. Here we present a novel IMAC strategy for effective extracting multi-phosphopeptides from complex samples, through Ga3+ chelation to the adenosine tri-phosphate (ATP)-functionalized magnetic nanoparticles (Ga3+-ATP-MNPs). The high specificity of Ga3+-ATP-MNPs was demonstrated by efficient enriching multi-phosphopeptides from the digest mixture of β-casein and BSA with molar ratio as low as 1:5000. Ga3+-ATP-MNPs were also successfully applied for the phosphoproteome analysis of rat liver mitochondria, resulting in the identification of 193 phosphopeptides with 331 phosphorylation sites from 158 phosphoproteins. In other words, 54.4% of the phosphopeptides trapped by Ga3+-ATP-MNPs were observed with more than one phosphorylated sites, resulting in significant improvement on the identification of peptides with multi-phosphorylated sites. The high specificity of Ga3+-ATP-MNPs towards multi-phosphopeptides may be due to the synergistic effect of the strong hydrophilic surface functionalized by ATP and the proper chelating strength provided by Ga3+. Moreover, the unique magnetic core of Ga3+-ATP-MNPs also facilitates the isolation process and on-plate enrichment for direct MALDI MS analysis with limit of detection as low as 30 amol. This new affinity-based protocol is expected to provide a powerful approach for characterizing multiple phosphorylation sites on proteins in complex and dilute analytes, which may be explored as complementary technique for improving the coverage of phosphoproteome.  相似文献   

5.
Atmospheric pressure matrix‐assisted laser desorption/ionization (AP‐MALDI) has proven a convenient and rapid method for ion production in the mass spectrometric (MS) analysis of biomolecules. AP‐MALDI and electrospray ionization (ESI) sources are easily interchangeable in most mass spectrometers. However, AP‐MALDI suffers from less‐than‐optimal sensitivity due to ion losses during transport from the atmosphere into the vacuum of the mass spectrometer. Here, we study the signal‐to‐noise ratio (S/N) gains observed when an on‐chip dynamic pre‐concentration/focusing approach is coupled to AP‐MALDI for the MS analysis of neuropeptides and protein digests. It was found that, in comparison with conventional AP‐MALDI targets, focusing targets showed (1) a sensitivity enhancement of approximately two orders of magnitude with S/N gains of 200–900 for hydrophobic substrates, and 150–400 for weak cation‐exchange (WCX) substrates; (2) improved detection limits as low as 5 fmol/µL for standard peptides; (3) significantly reduced matrix background; and (4) higher inter‐day reproducibility. The improved sensitivity allowed successful tandem mass spectrometric (MS/MS) sequencing of dilute solutions of a derivatized tryptic digest of a protein standard, and enabled the first reported AP‐MALDI MS detection of neuropeptides from Aedes aegypti mosquito heads. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
Due to its compatibility with protease activity at high concentration, sodium deoxycholate (SDC) can be used to effectively improve the solubilization and enzymolysis of membrane proteins and has received increasing attention in the field of membrane proteome analysis in recent years. SDC can be removed from digests by means of acidification followed by centrifugation (i.e. acid precipitation, AP) or extraction with ethyl acetate (i.e. phase transfer, PT) so as not to interfere with the downstream analyses like LC‐MS/MS. In this study, the two strategies were systematically evaluated, compared and optimized. The results of the study demonstrated that both of the AP and PT strategies led to a certain amount of tryptic peptides being lost, and in PT strategy even more peptides were lost during SDC removal process. However, the lost peptides could be mostly recovered by washing the pellet and solid content produced during AP and PT, respectively. By recovering the lost peptides, the identification efficiency of proteins, especially transmembrane and low abundance ones, was significantly improved. Comparatively, after optimization by recovering the lost peptides, AP strategy was superior to PT strategy because the former not only could achieve the comparable identification efficiency with the latter but also was more economical, safer and easier to operate than the latter.  相似文献   

7.
Electrospray ionization ion trap mass spectrometry (ESI-ITMS) coupled to a two-dimensional liquid chromatographic separation was applied to the identification of peptides in antimicrobial fractions of the aqueous extracts of nine Italian cheese varieties. In particular, the chromatographic fractions collected during a preliminary fast protein liquid chromatography (FPLC) separation on the cheese extracts were assayed for antimicrobial activity towards Lactobacillus sakei A15. Active fractions were subsequently analyzed by reversed-phase high-performance liquid chromatography electrospray ionization sequential mass spectrometry (HPLC/ESI)-ITMSn, with n up to 3. Peptide identification was then performed starting from a conventional proteomics approach based on tandem mass spectrometric (MS/MS) analysis followed by database searching. In many cases this strategy had to be integrated by a careful correlation between spectral information and predicted peptide fragmentation, in order to reach unambiguous identifications. When even this integrated approach failed, MS3 measurements provided decisive information on the amino acid sequence of some peptides, through fragmentation of pendant groups along the peptide chain. As a result, 45 peptides, all arising from hydrolysis of milk caseins, were identified in nine antimicrobial FPLC fractions of aqueous extracts obtained from five of the nine cheese varieties considered. Many of them corresponded to peptides already known to exhibit biological activity.  相似文献   

8.
A newly introduced high sensitivity laserspray (LSI) mass spectrometry (MS) method that uses laser ablation of a matrix/analyte mixture at atmospheric pressure (AP) to obtain multiply charged ions from nonvolatile as well as high-mass compounds is now implemented using a simple probe device. The probe used in the LSI approach was originally designed for sample introduction into an AP ionization source using the atmospheric solids analysis probe (ASAP) method. Multiply charged mass spectra of peptides and proteins in 2,5-dihydroxybenzoic acid matrix were readily obtained on two mass spectrometers from different manufacturers with sample introduction using melting point tubes. Here we demonstrate rapid analysis by placing four peptide and protein samples on a single melting point tube. Mass spectra were obtained at high-resolution and using ion mobility spectrometry/MS.  相似文献   

9.
The recent development and commercialization of Fuzeon (enfuvirtide) demonstrated that a convergent strategy comprised of both solid- and solution-phase synthetic methodologies presents a viable route for peptide manufacturing on a multi-ton scale. In this strategy, the target sequence is prepared by stepwise solid-phase synthesis of protected peptide fragments, which are then coupled together in the solution-phase to give the full-length sequence. These synthetic methodologies pose a unique challenge for mass spectrometry (MS), as protected peptide intermediates are often marked by poor solubility, structural lability, and low ionization potential. Matrix-assisted laser desorption/ionization (MALDI) MS is uniquely suited to such analytes; however, generalized protocols for MALDI analysis of protected peptides have yet to be demonstrated. Herein, we report an operationally simple sample preparation method for MALDI analysis of protected peptides, which greatly facilitates the collection and interpretation of MS data. In this method, the difficulty in MS analysis of protected peptides has been greatly diminished by use of dithranol as a matrix and CsCl as an additive, giving rise to intentionally-formed Cs(+) adducts. With greatly reduced fragmentation, better crystalline morphology, and easier data interpretation, we anticipate that these findings will find utility in peptide process development and manufacturing settings for reaction monitoring, troubleshooting, and quality control.  相似文献   

10.
An investigation of phosphate loss from phosphopeptide ions was conducted, using both atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI) and electrospray ionization (ESI) coupled to an ion trap mass spectrometer (ITMS). These experiments were carried out on a number of phosphorylated peptides in order to investigate gas phase dephosphorylation patterns associated with phosphoserine, phosphothreonine, and phosphotyrosine residues. In particular, we explored the fragmentation patterns of phosphotyrosine containing peptides, which experience a loss of 98 Da under collision induced dissociation (CID) conditions in the ITMS. The loss of 98 Da is unexpected for phosphotyrosine, given the structure of its side chain. The fragmentation of phosphoserine and phosphothreonine containing peptides was also investigated. While phosphoserine and phosphothreonine residues undergo a loss of 98 Da under CID conditions regardless of peptide amino acid composition, phosphate loss from phosphotyrosine residues seems to be dependent on the presence of arginine or lysine residues in the peptide sequence.  相似文献   

11.
High-throughput proteomics aims to investigate dynamically changing proteins expressed by a full organism, specific tissue or cellular compartment under certain conditions. High-sensitivity mass spectrometry has gradually become a significant tool for characterizing peptides. Here, we analyzed angiotensin II using ultra-fast liquid chromatography (UFLC) coupled with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS). First, we applied UFLC in isolating and collecting the angiotensin II, and then Axima-Resonance (MALDI-QIT-ToF MS(5)) was adopted, which enables collision-induced dissociation-MS(5) analysis for fine structural characterization of angiotensin II. Resultant MS, MS(2), MS(3) and MS(4) spectra of interested [M+H](+) ions selected as precursor ions yielded detailed information about the sites of fragmentation as well as the amino acid sequence for angiotensin II; meanwhile, the average deviation between theoretical mass and actually measured mass from MS to MS(5) spectra was only 0.32 Da. It indicated that Axima-Resonance was capable of analyzing the peptide sequence accurately and provide the corresponding fragmentation information thoroughly, thus suggesting a potential strategy involving UFLC assay coupled with MALDI-QIT-ToF MS(5) analysis on high-throughput proteomics study in future.  相似文献   

12.
Atmospheric pressure (AP) GC/MS was first introduced by Horning et al. [E.C. Horning, M.G. Horning, D.I. Carroll, I. Dzidic, R.N. Stillwell, Anal. Chem. 45 (1973) 936] using 63Ni as a beta-emitter for ionization. Because, at the time special instrumentation was required, the technique was only applied with consistency to negative ion environmental studies where high sensitivity was required [T. Kinouchi, A.T.L. Miranda, L.G. Rushing, F.A. Beland, W.A. Korfmacher, J. High Resolut. Chromatogr., Chromatogr. Commun. 13 (1990) 281]. Currently, AP ion sources are commonly available on LC/MS instruments and recently a method was reported for converting an AP-LC/MS ion source to a combination AP-LC/MS:GC/MS source [C.N. McEwen, R.G. McKay, J. Am. Soc. Mass Spectrom. 16 (2005) 1730]. Here, we report the use of atmospheric pressure photoionization (APPI) with GC/MS and compare this to AP chemical ionization (APCI) GC/MS and electron ionization (EI) GC/MS. Using a nitrogen purge gas, we observe excellent chromatographic resolution and abundant molecular M+ and MH+ ions as well as structurally significant fragment ions. Comparison of a 9.8 eV UV lamp with a 10.6 eV lamp, as expected, shows that the higher energy lamp gives more universal ionization and more fragment ions than the lower energy lamp. While there are clear differences in the fragment ions observed by APPI-MS versus EI-MS, there are also similarities. As might be expected from the ionization mechanism, APPI ionization is similar to low energy EI. These odd electron fragment ions are useful in identifying unknown compounds by comparison to mass spectra in computer libraries.  相似文献   

13.
Shiau KJ  Hung SU  Lee HW  Wu CC 《The Analyst》2011,136(9):1922-1927
Simultaneous detection of multiply and singly phosphorylated peptides using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is challenging because of suppression effects during ionization. In oder to overcome this problem, this study presents a new approach to improve the detection of phosphopeptides by stepwise enrichment using polyarginine-coated (PA-coated) and titanium dioxide-coated (TiO(2)-coated) nanodiamonds for fractionation of multiply and singly phosphorylated peptides prior to on-probe MALDI MS analysis. The feasibility of this approach was demonstrated using synthetic peptides containing different numbers of phosphate groups, tryptic digests of α-casein, β-casein, and complex protein mixtures. The high specificity of the approach is shown in its effective enrichment and fractionation of phosphopeptides from the digest of β-casein and bovine serum albumin at a molar ratio as low as 1 : 1000, which out-performs the commercial Fe(3+)-IMAC and TiO(2) isolation kits. It offers a simple and effective alternative for the fractionation and identification of multiply and singly phosphorylated peptides by MALDI MS and allows for deduction of more information from limited starting materials.  相似文献   

14.
A novel rearrangement reaction with a carbonyl oxygen migration was observed in the electrospray ionization tandem mass spectra of N-diisopropyloxyphosphoryl dipeptides and their analogues. A possible mechanism was proposed and supported by the MS/MS study, derivatization of different functional groups and deuterium labeling experiments. It was found that metal ions could catalyze the rearrangement through a five-membered ring intermediate. A strong affinity between the phosphoryl group and oxygen atom in the gas phase was proposed to result in this kind of rearrangement reaction, which might provide some basic information on the nature of phosphorylation in biochemistry. The replacement of N-terminal alpha-alanine by beta-alanine stopped the migration, which provides a simple method for differentiating the alpha- and beta-alanine residues at the N-terminus of peptides.  相似文献   

15.
The potential of protein fractionation hyphenated to mass spectrometry (MS) to detect and characterize the transgenic protein present in Roundup Ready soya and maize has been investigated. Genetically modified (GM) soya and maize contain the 5-enolpyruvylshikimate-3-phosphate synthase (EPSPS) gene from Agrobacterium tumefaciens CP4, which confers resistance to the herbicide glyphosate. The GM soya and maize proteomes were fractionated by gel filtration, anion-exchange chromatography and sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS-PAGE) prior to MS. This facilitated detection of a tryptic peptide map of CP4 EPSPS by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS and nanoelectrospray ionization quadrupole time-of-flight (nanoESI-QTOF) MS. Subsequently, sequence information from the CP4 EPSPS tryptic peptides was obtained by nanoESI-QTOF MS/MS. The identification was accomplished in 0.9% GM soya seeds, which is the current EU threshold for food-labeling requirements.  相似文献   

16.
Protein identification is routinely accomplished by peptide sequencing using mass spectrometry (MS) after enzymatic digestion. Site-specific chemical modification may improve peptide ionization efficiency or sequence coverage in mass spectrometry. We report herein that amino group of lysine residue in peptides can be selectively modified by reaction with a peroxycarbonate and the resulting lysine peroxycarbamates undergo homolytic fragmentation under conditions of low-energy collision-induced dissociation (CID) in electrospray ionization (ESI) and matrix-assisted laser desorption and ionization (MALDI) MS. Selective modification of lysine residue in peptides by our strategy can induce specific peptide cleavage at or near the lysine site. Studies using deuterated analogues of modified lysine indicate that fragmentation of the modified peptides involves apparent free-radical processes that lead to peptide chain fragmentation and side-chain loss. The formation of a-, c-, or z-types of ions in MS is reminiscent of the proposed free-radical mechanisms in low-energy electron capture dissociation (ECD) processes that may have better sequence coverage than that of the conventional CID method. This site-specific cleavage of peptides by free radical- promoted processes is feasible and such strategies may aid the protein sequencing analysis and have potential applications in top-down proteomics.  相似文献   

17.
An integrated analytical strategy for enrichment, detection and sequencing of phosphorylated peptides by matrix-assisted laser desorption/ionization (MALDI) tandem mass spectrometry (MS/MS) is reported. o-Phosphoric acid was found to enhance phosphopeptide ion signals in MALDI-MS when used as the acid dopant in 2,5-dihydroxybenzoic acid (2,5-DHB) matrix. The effect was largest for multiply phosphorylated peptides, which exhibited an up to ten-fold increase in ion intensity as compared with standard sample preparation methods. The enhanced phosphopeptide response was observed during MALDI-MS analysis of several peptide mixtures derived by proteolytic digestion of phosphoproteins. Furthermore, the mixture of 2,5-DHB and o-phosphoric acid was an excellent eluant for immobilized metal affinity chromatography (IMAC). Singly and multiply phosphorylated peptide species were efficiently recovered from Fe(III)-IMAC columns, reducing sample handling for phosphopeptide mapping by MALDI-MS and subsequent phosphopeptide sequencing by MALDI-MS/MS. The enhanced response of phosphopeptide ions in MALDI facilitates MS/MS of large (>3 kDa) multiply phosphorylated peptide species and reduces the amount of analyte needed for complete characterization of phosphoproteins.  相似文献   

18.
The spatial distribution of proteins in tissue sections can be used to identify potential markers for pathological processes. Tissue sections are often subjected to enzymatic digestion before matrix‐assisted laser desorption/ionization (MALDI) imaging. This study is targeted at improving the on‐tissue identification of tryptic peptides by accurate mass measurements and complementary off‐line liquid chromatography coupled to electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) analysis. Two adjacent mouse brain sections were analyzed in parallel. The first section was spotted with trypsin and analyzed by MALDI imaging. Direct on‐tissue MS/MS experiments of this section resulted in the identification of 14 peptides (originating from 4 proteins). The second tissue section was homogenized, fractionated by ultracentrifugation and digested with trypsin prior to LC/ESI‐MS/MS analysis. The number of identified peptides was increased to 153 (corresponding to 106 proteins) by matching imaged mass peaks to peptides which were identified in these LC/ESI‐MS/MS experiments. All results (including MALDI imaging data) were based on accurate mass measurements (RMS <2 ppm) and allow a confident identification of tryptic peptides. Measurements based on lower accuracy would have led to ambiguous or misleading results. MS images of identified peptides were generated with a bin width (mass range used for image generation) of Δm/z = 0.01. The application of accurate mass measurements and additional LC/MS measurements increased both the quality and the number of peptide identifications. The advantages of this approach for the analysis of biological tissue sections are demonstrated and discussed in detail. Results indicate that accurate mass measurements are needed for confident identification and specific image generation of tryptic peptides in tissue sections. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
In an investigation devoted to the search for plasma markers for colorectal cancer (CRC), carried out by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry, a series of overexpressed peptides were identified in the plasma of patients. Among them the peptide with molecular weight 903 Da was the most abundant one, with a mean +/- (SD) relative abundance of 37 +/- 17% and a frequency over 60%. Interestingly, also in plasma samples of ten subjects affected by familial adenomatous polyposis (FAP), the peptide with molecular weight 903 was overexpressed. In this investigation, MALDI/MS/MS experiments were carried out on the ion at m/z 904 detected in the MALDI mass spectra of CRC and FAP patients. The data analysis by SwissProt.2007.01.09 indicates that this peptide is due to the sequence RPPGFSPF, found in the kininogen-1 precursor, which is an alpha-2-thiol proteinase inhibitor. In the case of subjects affected by a particular FAP syndrome, the MALDI/MS/MS spectra were quite different from those obtained from CRC and FAP patients. In fact, two sequences have been evidenced: RPPGFSPF belonging to kininogen-1 precursor, and PRKSSSSR belonging to Forkhead box protein 01A.  相似文献   

20.
S-nitrosylation of proteins serves an important role in regulating diverse cellular processes including signal transduction, DNA repair, and neurotransmission. Identification of S-nitrosylation sites is crucial for understanding the significance of this post-translational modification (PTM) in modulating the function of a protein. However, it is challenging to identify S-nitrosylation sites directly by mass spectrometric (MS) methods due to the labile nature of the S-NO bond. Here we describe a strategy for direct identification of protein S-nitrosylation sites in an electrospray ionization (ESI) quadrupole time-of-flight (QTOF) mass spectrometer without prior chemical derivatization of S-nitrosylated peptides. Both sample buffer composition and MS hardware parameters were carefully adjusted to ensure that S-nitrosylated peptide ions could be analyzed by the QTOF MS with optimal signal/noise ratios. It was crucial that the proteins were preserved in a sample solution containing 1 mM EDTA and 0.1 mM neocuproine at neutral pH. Proteins dissolved in this solution are amenable to in-solution tryptic digestion, which is important for the analysis of biological samples. S-nitrosylated peptides were effectively analyzed by LC/MS/MS on QTOF MS, with an optimized cone voltage of 20 V and collision energy of 4 V. We have successfully applied this method to thioredoxin, a key antioxidant protein, and identified within it an S-nitrosylation site at Cys73.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号