首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 937 毫秒
1.
A highly sensitive liquid chromatography–tandem mass spectrometry (LC–MS–MS) method for the determination of troxerutin in human plasma using tramadol as internal standard (IS) has been developed and validated. Sample preparation involved liquid–liquid extraction with ethyl acetate–isopropanol (95:5, v/v). The analyte and IS were separated by RP–LC with gradient elution using 10 mM ammonium acetate containing 0.1% formic acid and methanol at a flow rate of 0.9 mL min?1. LC–MS–MS in the positive ion mode employed multiple reaction monitoring of the transitions at m/z 743.2→435.3 and m/z 264.1→58.0 for troxerutin and IS, respectively. The assay was linear in the concentration range 0.01–10 ng mL?1 with precision and accuracy within assay variability limits as per FDA guidelines. The assay was successfully applied to a pharmacokinetic study involving oral administration of 300 mg troxerutin to eight healthy Chinese volunteers.  相似文献   

2.
A simple and rapid LC–MS–MS assay was developed and validated for the quantitative determination of pitavastatin in human plasma. Sample pretreatment involved simple protein precipitation by addition of acetonitrile. Separation was on an Agilent 1.8 μm Zorbax SB-C18 column (150 mm × 4.6 mm) at 25 °C using isocratic elution with methanol–0.1% formic acid in water (85:15, v/v) at a flow rate of 0.4 mL min?1. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the ion transitions m/z 422.0 → 290.1 for pitavastatin, and m/z 330.1 → 192.1 for paroxetine (IS). LC–MS–MS was found to improve the quantitation of pitavastatin in plasma and was successfully applied in pharmacokinetic studies.  相似文献   

3.
A sensitive and selective liquid chromatographic tandem mass spectrometric (LC–MS–MS) method was developed for simultaneous identification and quantification of tamsulosin and dutasteride in human plasma, which was well applied to clinical study. The method was based on liquid–liquid extraction, followed by an LC procedure with a Gemini C-18, 50 mm × 2.0 mm (3 μm) column and using methanol:ammonium formate (97:3, v/v) as the mobile phase. Protonated ions formed by a turbo ionspray in positive mode were used to detect analytes and internal standard. MS–MS detection was by monitoring the fragmentation of 409.1 → 228.1 (m/z) for tamsulosin, 529.3 → 461.3 (m/z) for dutasteride and 373.2 → 305.3 (m/z) for finasteride (IS) on a triple quadrupole mass spectrometer. The lower limit of quantification for both tamsulosin and dutasteride was 1 ng mL?1. The proposed method enables the unambiguous identification and quantification of tamsulosin and dutasteride for clinical drug monitoring.  相似文献   

4.
A sensitive LC–MS–MS method with electrospray ionization has been developed for analysis of mirtazapine in rat plasma. After addition of diazepam as internal standard, liquid–liquid extraction was used to produce a protein-free extract. Chromatographic separation was achieved on a 150 × 4.6 mm, 5 μm particle, ODS column with 84:16 (v/v) methanol–water containing 0.1% ammonium acetate and 0.01% glacial acetic acid as mobile phase. LC–MS–MS was performed in selected-ion-monitoring (SIM) mode using target fragment ions m/z 195.09 for mirtazapine and m/z 192.80 for the IS. Calibration plots were linear over the range of 0.516–618.8 ng mL?1. The lower limit of quantification was 0.516 ng mL?1. Intra-day and inter-day precision were better than 12.6 and 8.8%, respectively. Mean recovery of mirtazapine from plasma was in the range 87.41–90.06%; average recovery was 88.40% (RSD 3.95%). Significant gender differences between mirtazapine pharmacokinetic data were observed in this study.  相似文献   

5.
Batifiban is a new platelet GPIIb/IIIa receptor antagonist. In this work, an analytical method based on liquid chromatography and electrospray ionization tandem mass spectrometry has been firstly developed and validated for the quantitative measurement of batifiban in human plasma to support the investigation of this compound. Separation of analyte and the internal standard eptifibatide was performed on a Thermo HyPURITY C18 column (150 × 2.1 mm, 5 μm) with a mobile phase consisting of formic acid 0.1% (v/v)–acetonitrile (40:60, v/v) at a flow rate of 0.25 mL min?1. The Waters QuattroMicro API triple quadrupole mass spectrometer was operated in multiple reaction monitoring mode via positive electrospray ionization interface using the transition m/z 819.2 → m/z (623.9 + 159.4) for batifiban and m/z 833.4 → m/z (645.7 + 159.3) for IS. The method was linear over the concentration range of 2.45–5,000 μg L?1. The intra- and inter- day precisions were less than 15% in terms of relative standard deviation, and the accuracy was within 8.5% in terms of relative error (RE). The lower limit of quantification (LLOQ) was identifiable and reproducible at 2.45 μg L?1 with acceptable precision and accuracy. The validated method offered sensitivity and wide linear concentration range. This method was successfully applied for the evaluation of pharmacokinetics of batifiban afer single oral doses of 55, 110 and 220 μg kg?1 batifiban to 36 Chinese healthy volunteers.  相似文献   

6.
A rapid liquid chromatographic method with electrospray ionization tandem mass spectrometric detection has been developed and validated for quantification of quetiapine in heparinized human plasma. Plasma samples, without a drying and reconstitution step, were extracted by solid-phase extraction and eluted with acetonitrile. The analyte and zolpidem tartrate (internal standard, IS) were chromatographed on a C18 column; the mobile phase was 85:15 (v/v) acetonitrile–5 mM ammonium formate, pH adjusted to 4.5 with formic acid, at a flow rate of 0.5 mL min?1. The retention times of quetiapine and the IS were 1.25 and 1.05 min, respectively, and the run time was 1.8 min per sample. Selected reaction monitoring of MH+ at m/z 384.12 and 308.11 resulted in stable fragment ions with m/z 253.02 and 235.09 for quetiapine and the IS, respectively. Response was a linear function of concentration in the range 1.0–240.0 ng mL?1, with r ≥ 0.9994. Recovery of quetiapine and the IS ranged from 74.82 to 85.57%. The assay has excellent characteristics and has been successfully used for analysis of quetiapine in healthy human subjects in a bioequivalence study.  相似文献   

7.
Ding  Chenxu  Wang  Lingyun  Tian  Chunliang  Li  Yulin  Sun  Zhiwei  Wang  Honglun  Suo  Yourui  You  Jinmao 《Chromatographia》2008,67(11):893-903

A sensitive and selective liquid chromatographic tandem mass spectrometric (LC–MS–MS) method was developed for simultaneous identification and quantification of tamsulosin and dutasteride in human plasma, which was well applied to clinical study. The method was based on liquid–liquid extraction, followed by an LC procedure with a Gemini C-18, 50 mm × 2.0 mm (3 μm) column and using methanol:ammonium formate (97:3, v/v) as the mobile phase. Protonated ions formed by a turbo ionspray in positive mode were used to detect analytes and internal standard. MS–MS detection was by monitoring the fragmentation of 409.1 → 228.1 (m/z) for tamsulosin, 529.3 → 461.3 (m/z) for dutasteride and 373.2 → 305.3 (m/z) for finasteride (IS) on a triple quadrupole mass spectrometer. The lower limit of quantification for both tamsulosin and dutasteride was 1 ng mL−1. The proposed method enables the unambiguous identification and quantification of tamsulosin and dutasteride for clinical drug monitoring.

  相似文献   

8.
Ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) is a preeminent analytical tool for rapid biomedical analysis with the objective of reducing analysis time and maintaining good efficiency. In this study a simple, rapid, sensitive and specific ultra-performance liquid chromatography–tandem mass spectrometry method was developed and validated for quantification of the angiotensin II receptor antagonist, irbesartan and hydrochlorthiazide in human plasma. After a simple protein precipitation using methanol and acetonitrile, irbesartan, hydrochlorthiazide and internal standard (IS) telmisartan were separated on Acquity UPLC BEH? C18 column (50 × 2.1 mm, i.d. 1.7 μm, Waters, USA) using a mobile phase consisting of acetonitrile:10 mM ammonium acetate:formic acid (85:15:0.1 % v/v/v) pumped at a flow rate of 0.3 mL/min and detected by tandem mass spectrometry with negative ion mode. The ion transitions recorded in multiple reaction monitoring mode were m/z 427.2 → 193.08 for irbesartan, m/z 295.93 → 268.90 for hydrochlorthiazide and m/z 513.2 → 287.14 for IS. The assay exhibited a linear dynamic range of 30–500 ng/mL for irbesartan and 1–500 ng/mL in human plasma with good correlation coefficient of (0.996) and (0.997) and with a limit of quantitation of 30  and 1 ng/mL for irbesartan and hydrochlorthiazide, respectively. The intra- and inter-assay precisions were satisfactory; the relative standard deviations did not exceed 10.13 % for irbesartan and 11.14 % for hydrochlorthiazide. The proposed UPLC–MS/MS method is simple, rapid and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans.  相似文献   

9.
We report the development and validation of a high-performance liquid-chromatographic–tandem mass spectrometric method for determination of artemether (ARM) and its active metabolite dihydroartemisinin (DHA) in human plasma; artemisinin was used as internal standard (IS). Chromatographic separation was performed on a 150 mm × 4.6 mm i.d., 5 μm particle, C18 column coupled with a 4.0 mm × 3.0 mm i.d., 5 μm particle, C18 guard column. The mobile phase was acetonitrile–0.1% formic acid solution, 80:20 (v/v), at a flow-rate of 1 mL min?1. An atmospheric-pressure chemical-ionization (APCI) interface was used to produce sample ions, and positive ions were quantified by using the MS detector in selected-reaction-monitoring mode, using the reaction m/z 221 to 163 for determination of ARM and DHA and the reaction m/z 283 to 219 for determination of the IS. Plasma samples were prepared by extraction with methyl t-butyl ether, evaporation of the extract to dryness, and reconstitution of the residue with mobile phase. Extraction recovery for ARM and DHA ranged from 74.74 to 99.39%. High specificity and a limit of quantification of 5 ng mL?1 were achieved for ARM and DHA. Linearity was confirmed over the concentration range 5–500 ng mL?1; the correlation coefficients (R) were >0.99. The relative standard deviation for intra-day and inter-day assay of both compounds was <9.60% and inaccuracy was within ±10.81%. Stock solutions were stable at 4 °C for at least 720 h. Processed extracts were stable at room temperature for at least 24 h and QC samples were stable during three freeze–thaw cycles. In spiked human plasma under ambient conditions ARM was stable for at least 8 h whereas DHA was stable for 2 h only.  相似文献   

10.
A sensitive LC–MS–MS method with electrospray ionization has been developed for determination of nikethamide in human plasma. After addition of atropine as internal standard, liquid–liquid extraction was used to produce a protein-free extract. Chromatographic separation was achieved on a 150 mm × 2.1 mm, 5 μm particle, Agilent Zorbax SB-C18 column, with 45:55 (v/v) methanol–water containing 0.1% formic acid as mobile phase. LC–MS–MS was performed in multiple reaction monitoring mode using target fragment ions m/z 178.8 → 107.8 for nikethamide and m/z 289.9 → 123.8 for the internal standard. Calibration plots were linear over the range of 20.0–2,000 ng mL?1. The lower limit of quantification was 20.0 ng mL?1. Intra-day and inter-day precisions were better than 4.2 and 6.1%, respectively. Mean recovery of nikethamide from human plasma was in the range 65.3–71.1%.  相似文献   

11.
Methoxetamine is a new ketamine derivative designer drug which has recently become available via the Internet marketed as “legal ketamine”. It is a new dissociative recreational drug, acting as an NMDA receptor antagonist and dopamine reuptake inhibitor. The objective of this study was to develop on-line automated sample preparation using a TurboFlow device coupled with liquid chromatography with ion-trap mass spectrometric detection for measurement of methoxetamine in human plasma. Samples (100 μL) were vortex mixed with internal standard solution (ketamine-d4 in acetonitrile). After centrifugation, 20 μL of the supernatant was injected on to a 50 mm?×?0.5-mm C18XL Turboflow column. The retained analytes were then back-flushed on to a 50 mm?×?3-mm (3 μm) Hypersil Gold analytical column for chromatographic separation, then eluted with a formate buffer–acetonitrile gradient. Methoxetamine and the IS were ionized by electrospray in positive mode. Parent [M + H]+ ions were m/z 248.1 for methoxetamine and m/z 242.0 for the IS. The most intense product ions from methoxetamine (m/z 203.0) and the IS (m/z 224.0) were used for quantification. The assay was accurate (96.8–108.8 % range) and precise (intra and inter-day coefficients of variation <8.8 %) over the range of 2.0 (lower limit of quantification) to 1000.0 ng mL?1 (upper limit of quantification). No matrix effect was observed. This method has been successfully applied to determination of plasma concentrations of methoxetamine in the first French hospitalization case report after acute intoxication; the plasma concentration was 136 ng mL?1.  相似文献   

12.
A simple and rapid reversed-phase LC method was developed and validated for simultaneous determination of three flavonoids, quercetin (QU), kaempferol (KA) and isorhamnetin (IS), in rabbit blood plasma. The plasma was deproteinized using 10% trichloroacetic acid and extracted by n-butanol–acetoacetate solvent prior to LC analysis. The analyte was separated on a reversed-phase column with acetonitrile and 0.1% phosphoric acid in water (27:73, v/v) as mobile phase at a flow-rate of 0.8 mL min?1, and UV detection wavelength at 369 nm. By this developed method, the concentrations of QU, KA and IS were linearly related to their responses in the range of 0.05–2.5 μg mL?1. The precision and accuracy for QU, KA and IS in plasma were within ±15% except for the limit of quantitation (LOQ), where they were within ±20%. The validated method has been successfully applied in the pharmacokinetic study of QU, KA and IS in rabbits after intragastric administration of an ethanol extract from traditional Chinese medicine Pollen Typhae.  相似文献   

13.

A rapid liquid chromatographic method with electrospray ionization tandem mass spectrometric detection has been developed and validated for quantification of quetiapine in heparinized human plasma. Plasma samples, without a drying and reconstitution step, were extracted by solid-phase extraction and eluted with acetonitrile. The analyte and zolpidem tartrate (internal standard, IS) were chromatographed on a C18 column; the mobile phase was 85:15 (v/v) acetonitrile–5 mM ammonium formate, pH adjusted to 4.5 with formic acid, at a flow rate of 0.5 mL min−1. The retention times of quetiapine and the IS were 1.25 and 1.05 min, respectively, and the run time was 1.8 min per sample. Selected reaction monitoring of MH+ at m/z 384.12 and 308.11 resulted in stable fragment ions with m/z 253.02 and 235.09 for quetiapine and the IS, respectively. Response was a linear function of concentration in the range 1.0–240.0 ng mL−1, with r ≥ 0.9994. Recovery of quetiapine and the IS ranged from 74.82 to 85.57%. The assay has excellent characteristics and has been successfully used for analysis of quetiapine in healthy human subjects in a bioequivalence study.

  相似文献   

14.
A sensitive and specific liquid chromatography–electrospray ionization–tandem mass spectrometry method has been developed and validated for the quantification of huperzine A in human plasma. After the addition of trimetazidine, the internal standard (IS) and sodium hydroxide, plasma samples were extracted using 5 mL ethyl acetate. The compounds were separated on an Agilent Zorbax SB C18 column (100 mm × 2.1 mm ID, dp 3.5 μm) using an elution system of 10 mM ammonium acetate solution–methanol–formic acid (18:82:0.1, v/v) as the mobile phase. The quantification of target compounds was obtained by using multiple reaction monitoring (MRM) transitions: m/z 243.1, 210.1 and 267.2, 166.0 were measured in positive mode for huperzine A and IS. Linearity was established for the range of concentrations 0.01–4.0 ng mL?1 with a coefficient of correlation (r) of 0.9991. The lower limit of quantification (LLOQ) was identifiable and reproducible at 0.01 ng mL?1. The method has been successfully applied to study the pharmacokinetics of huperzine A in healthy male Chinese volunteers.  相似文献   

15.
A sensitive and specific liquid chromatography–tandem mass spectrometry (LC–MS–MS) method was developed and validated for the quantification of poricoic acid A (PAA) in rat plasma. The plasma samples were precipitated by protein precipitation with methanol. Glycyrrhetic acid was used as the IS. Chromatography was performed on a Dionex C18 120 Å (4.6 × 250 mm, 5 μm) column with the mobile phase composed of acetonitrile–water (90:10, v/v) at a flow rate of 0.8 mL min?1. A tandem mass spectrometer equipped with an ESI source was used as the detector and was operated in the negative ion mode. Quantification was performed using multiple reaction monitoring (MRM) of the transitions m/z 497.4 → 423.3 and m/z 469.2 → 425.1 for PAA and IS, respectively. The calibration curves were linear over the range of 5–5,000 ng mL?1 (r 2 = 0.9966) and the lower limit of quantification (LLOQ) was 5 ng mL?1. In this range, RSDs were <10% for intra-assay and inter-assay precisions. The accuracy expressed by deviation (DEV) was <6%, and the extraction recoveries of QC samples were >78%. The validated method was successfully used to study the pharmacokinetics of PAA in rats after intravenous administration at a dose of 1.0, 2.5 and 5.0 mg kg?1 and oral administration at a dose of 25, 50 and 100 mg kg?1, respectively. The relative bioavailability of PAA in rats following oral administration was achieved.  相似文献   

16.
Kim  Bora  Shin  Hyun-Suk  Kim  Jung-Ryul  Lim  Kyung-Soo  Yoon  Seo Hyun  Yu  Kyung-Sang  Shin  Sang-Goo  Jang  In-Jin  Cho  Joo-Youn 《Chromatographia》2012,75(11):671-677

A simple, rapid and sensitive LC–MS/MS method in positive ion mode was developed and validated to determine CKD-501, lobeglitazone, in human plasma and urine using glipizide as an internal standard (IS). Lobeglitazone is a novel thiazolidinedione (TZDs)-based peroxisome proliferator-activated receptor (PPAR) agonist, used for the management of type-2 diabetes. After mixing the IS, dissolved in acetonitrile, with a plasma or urine sample containing lobeglitazone, 10 μL of supernatant was injected into the LC–MS/MS system. Quantification was performed in the multiple reaction monitoring (MRM) mode using transition of 481.5 → 152.2 (m/z) for lobeglitazone and 446.1 → 321.2 (m/z) for the IS. The method showed good linearity over concentration ranges of 0.5–1,000 ng mL−1 for plasma and 0.2–250 ng mL−1 for urine (r 2 ≥ 0.9996). The mean percent extraction recovery of lobeglitazone was 90.8 % for plasma and 87.3 % for urine, while the recoveries of the IS were greater than 86.4 % for both. The intra-day and inter-day precision of plasma ranged from 1.1 to 3.7 and 2.5 to 3.3 % (RSD), respectively, and the intra- and inter-day precision of urine ranged from 1.5 to 2.7 and 3.2 to 3.5 %, respectively. This method is simple, sensitive, and applicable for the pharmacokinetic study of lobeglitazone in human plasma. Most of the urine concentrations of lobeglitazone were below the LLOQ because the lobeglitazone is extensively metabolized.

  相似文献   

17.
A sensitive and selective liquid chromatography tandem mass spectrometry (LC-MS-MS) method for determination of doxapram hydrochloride in rabbit plasma was developed. After addition of urapidil hydrochloride as internal standard (IS), protein precipitation by 10% trichloroacetic acid in methanol (w/v) was used as sample preparation. Chromatographic separation was achieved on a Zorbax SB-C18 (2.1 mm × 50 mm, 3.5 μm) column with acetonitrile–water as mobile phase with gradient elution. Electrospray ionization (ESI) source was applied and operated in positive ion mode; multiple reaction monitoring (MRM) mode was used for quantification using target fragment ions m/z 378.9 → 291.8 for doxapram hydrochloride and m/z 387.9 → 204.6 for the IS. Calibration plots were linear over the range of 2–1000 ng mL?1 for doxapram hydrochloride in plasma. Lower limit of quantitation (LLOQ) for doxapram hydrochloride was 2 ng mL?1. Mean recovery of doxapram hydrochloride from plasma was in the range 83.7–91.5%. RSD of intra-day and inter-day precision were less than 9%, respectively. This method is simple and sensitive enough to be used in pharmacokinetic research for determination of doxapram hydrochloride in rabbit plasma.  相似文献   

18.
A sensitive and specific liquid chromatography–electrospray ionization-tandem mass spectrometry method has been developed and validated for the identification and quantification of ursolic acid in human plasma using glycyrrhetic acid as an internal standard. The method involves extraction with methyl tert-butyl ether. The analyte was separated on a C18 column and analyzed in multiple reaction monitoring mode with a negative electrospray ionization interface using the [M–H]? ions, m/z 455.4 for ursolic acid and m/z 469.5 → m/z 425.5 for glycyrrhetic acid. The method was validated over the concentration range of 0.86–110.0 μg L?1. The intra- and inter-day precisions were less than 13.53% relative standard deviation (RSD) and the accuracy was within ?4.76% in terms of relative error (RE). The lower limit of quantification was 0.86 μg L?1 with acceptable precision and accuracy. There were almost no matrix effects. Recovery of ursolic acid from spiked drug-free plasma was higher than 68%. The method was used to study the pharmacokinetic profile of ursolic acid in human plasma after oral administration of Jieyu capsules.  相似文献   

19.
A simple, rapid and sensitive LC–MS/MS method in positive ion mode was developed and validated to determine CKD-501, lobeglitazone, in human plasma and urine using glipizide as an internal standard (IS). Lobeglitazone is a novel thiazolidinedione (TZDs)-based peroxisome proliferator-activated receptor (PPAR) agonist, used for the management of type-2 diabetes. After mixing the IS, dissolved in acetonitrile, with a plasma or urine sample containing lobeglitazone, 10?μL of supernatant was injected into the LC–MS/MS system. Quantification was performed in the multiple reaction monitoring (MRM) mode using transition of 481.5?→?152.2 (m/z) for lobeglitazone and 446.1?→?321.2 (m/z) for the IS. The method showed good linearity over concentration ranges of 0.5–1,000?ng?mL?1 for plasma and 0.2–250?ng?mL?1 for urine (r 2?≥?0.9996). The mean percent extraction recovery of lobeglitazone was 90.8?% for plasma and 87.3?% for urine, while the recoveries of the IS were greater than 86.4?% for both. The intra-day and inter-day precision of plasma ranged from 1.1 to 3.7 and 2.5 to 3.3?% (RSD), respectively, and the intra- and inter-day precision of urine ranged from 1.5 to 2.7 and 3.2 to 3.5?%, respectively. This method is simple, sensitive, and applicable for the pharmacokinetic study of lobeglitazone in human plasma. Most of the urine concentrations of lobeglitazone were below the LLOQ because the lobeglitazone is extensively metabolized.  相似文献   

20.
An LC-MS-MS method was revised and validated for simultaneous determination of icariin and its active metabolite icariside II in human plasma. The analytes and daidzein (IS) were extracted by liquid–liquid extraction and analyzed by LC-MS-MS. The separation was performed by a Zorbax SB-C18 column (3.5 μm, 2.1 × 100 mm) with an isocratic mobile phase consisting of methanol–water–formic acid (65:35:0.035, v/v/v) at a flow rate of 0.25 mL min?1. Detection was performed on a triple quadrupole tandem mass spectrum by multiple reaction monitoring mode using the electrospray ionization technique in positive mode. The method had lower limits of quantitation 0.2 and 0.1 ng mL?1 for icariin and icariside II, respectively, using 500 μL plasma sample. The linear calibration curves were obtained in the concentration range of 0.2–100 ng mL?1 for icariin and 0.1–100 ng mL?1 for icariside II. The RSD values of intra- and inter-day precision calculated from quality control (QC) samples were less than 7.2% for icariin and less than 6.5% for icariside II. The accuracy as determined from QC samples was within 3.8% for each analyte. The method has been applied to determine and evaluate the pharmacokinetic of icariin and its metabolite icariside II in volunteers following oral administration of icariin and extract of Epimedium, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号