首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A high‐performance liquid chromatographic (HPLC) method with integrated solid‐phase extraction for the determination of 1‐hydroxypyrene and 1‐, 2‐, 3‐, 4‐ and 9‐hydroxyphenanthrene in urine was developed and validated. After enzymatic treatment and centrifugation of 500 μL urine, 100 μL of the sample was directly injected into the HPLC system. Integrated solid‐phase extraction was performed on a selective, copper phthalocyanine modified packing material. Subsequent chromatographic separation was achieved on a pentafluorophenyl core–shell column using a methanol gradient. For quantification, time‐programmed fluorescence detection was used. Matrix‐dependent recoveries were between 94.8 and 102.4%, repeatability and reproducibility ranged from 2.2 to 17.9% and detection limits lay between 2.6 and 13.6 ng/L urine. A set of 16 samples from normally exposed adults was analyzed using this HPLC‐fluorescence detection method. Results were comparable with those reported in other studies. The chromatographic separation of the method was transferred to an ultra‐high‐performance liquid chromatography pentafluorophenyl core–shell column and coupled to a high‐resolution time‐of‐flight mass spectrometer (HR‐TOF‐MS). The resulting method was used to demonstrate the applicability of LC‐HR‐TOF‐MS for simultaneous target and suspect screening of monohydroxylated polycyclic aromatic hydrocarbons in extracts of urine and particulate matter.  相似文献   

2.
A new paratert‐butylcalix[4]arene column containing thiadiazole functional groups was prepared and used for the separation of polycyclic aromatic hydrocarbons, phenolic compounds, aromatic amines, benzoic acid and its derivatives by high‐performance liquid chromatography (HPLC). The effect of organic modifier content in the mobile phase on retention and selectivity of these compounds were investigated. The results indicate that the stationary phase behaves like reversed‐phase packing. However, hydrogen bonding, π–π and inclusion interactions seem to be involved in the separation process. The column has been successfully employed for the analysis of clenbuterol in pork and pig casing; the limit of detection and the limit of quantitation for this method by HPLC‐UV detection was 0.03 and 0.097 μg/mL, respectively; the method is demonstrated to be suitable and a competitive alternative analytical method for the determination of clenbuterol.  相似文献   

3.
A new solid‐phase extraction (SPE) pretreatment method using a home‐made polyvinylpolypyrrolidone‐florisil (PVPP‐F) column was developed for the analysis of patulin in apple and hawthorn products in China. Fifty samples (25 apple juices, 12 apple jams, and 13 hawthorn juices) were prepared using the new method and then analyzed by high performance liquid chromatography with diode array detection (HPLC‐DAD) on an Agela Venusil MP C18 reversed‐phase column (4.6 mm × 250 mm, 5 μm). The cleanup results for all samples using home‐made PVPP‐F column were compared with those obtained using a MycoSep®228 AflaPat column. The correlation coefficient R (0.9998) fulfilled the requirement of linearity for patulin in the concentration range of 2.5–250 μg/kg. The limits of detection (LODs) and quantification (LOQs) of patulin were 3.99 and 9.64 μg/kg for PVPP‐F column, and 3.56 and 8.07 μg/kg for MycoSep®228 AflaPat column, respectively. Samples were spiked with patulin at levels ranging from 25 to 250 μg/kg, and recoveries using PVPP‐F and MycoSep®228 AflaPat columns were in the range of 81.9–100.9% and 86.4–103.9%, respectively. Naturally occurring patulin was found in 2 of 25 apple juice samples (8.0%) and 1 of 13 hawthorn juice samples (7.7%) at concentrations ranging from 12.26 to 36.81 μg/kg. The positive results were further confirmed by liquid chromatography electrospray ionization mass spectrometry (LC‐ESI‐MS).  相似文献   

4.
Tigecycline (TIG), a derivative of minocycline, is the first in the novel class of glycylcyclines and is currently indicated for the treatment of complicated skin structure and intra‐abdominal infections. A selective, accurate and reversed‐phase high‐performance liquid chromatography‐tandem mass spectrometry (HPLC‐MS/MS) method was developed for the determination of TIG in rat brain tissues. Sample preparation was based on protein precipitation and solid phase extraction using Supel‐Select HLB (30 mg/1 mL) cartridges. The samples were separated on a YMC Triart C18 column (150 mm x 3.0 mm. 3.0 µm) using gradient elution. Positive electrospray ionization (ESI+) was used for the detection mechanism with the multiple reaction monitoring (MRM) mode. The method was validated over the concentration range of 150–1200 ng/mL for rat brain tissue. The precision and accuracy for all brain analyses were within the acceptable limit. The mean extraction recovery in rat brain was 83.6%. This validated method was successfully applied to a pharmacokinetic study in female Sprague Dawley rats, which were given a dose of 25 mg/kg TIG intraperitoneally at various time‐points. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
Carbendazim residues were analyzed by column‐switching high‐performance liquid chromatography (HPLC) with photodiode array detection (PDA). The active ingredient was extracted by matrix solid‐phase dispersion (MSPD) from wheat grain on an acidic silica gel column using a methanol‐dichloromethane mixture. The recovery rate for fortified samples was 87.3 ± 3.3% with a standard deviation (SD) of 2.9%. The detection limit was 0.02 μg/mL. The method was applied to the determination of carbendazim residues in wheat grain samples from a treated field.  相似文献   

6.
A novel method was developed for the simultaneous determination of kynurenine and tryptophan by high‐performance liquid chromatography with electrochemical detection at multi‐wall carbon nanotube (MWCNT)‐modified glassy carbon electrode. The separation and detection conditions were optimized. The typical HPLC experiments were conducted by using a reversed‐phase ODS column with a mobile phase consisting of stock acetate buffer (pH 5)–methanol (4:1, v/v) using an isocratic elution at the flow rate of 1.0 mL/min. The obtained LODs for kynurenine and tryptophane were 0.5 and 0.4 µmol/L, respectively. The analytical method for human plasma samples was validated and confirmed by LC‐UV and LC‐MS. The recoveries were in the range of 84.8–110%, and the precision was lower than 5.9%. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
To support pharmacokinetic‐guided dosing in individual patients, a fast and accurate method for simultaneous determination of anticancer tyrosine kinase inhibitors (TKIs) dasatinib, erlotinib, gefitinib, imatinib, lapatinib, nilotinib, sorafenib and sunitinib in human plasma was developed using high‐performance liquid chromatography and detection with tandem mass spectrometry (HPLC‐MS/MS). Stable isotopically labeled compounds of the eight different TKIs were used as internal standards. Plasma proteins were precipitated and an aliquot of supernatant was directly injected onto a reversed phase chromatography system consisting of a Gemini C18 column (50 × 2.0 mm i.d., 5.0 µm particle size) and then compounds were eluted with a gradient. The outlet of the column was connected to a triple quadrupole mass spectrometer with electrospray interface. Ions were detected in the positive multiple reaction monitoring mode. This method was validated over a linear range from 20.0 to 10,000 ng/mL for erlotinib, gefitinib, imatinib, lapatinib, nilotinib and sorafenib, and from 5.00 to 2500 ng/mL for dasatinib and sunitinib. Results from the validation study demonstrated good intra‐ and inter‐assay accuracy (<13.1%) and precision (10.0%) for all analytes. This method was successfully applied for routine therapeutic drug monitoring purposes in patients treated with the investigated TKIs. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
An environmentally friendly ionic liquids dispersive liquid–liquid microextraction (IL‐DLLME) method coupled with high‐performance liquid chromatography (HPLC) for the determination of antihypertensive drugs irbesartan and valsartan in human urine samples was developed. The HPLC separations were accomplished in less than 10 min using a reversed‐phase C18 column (250 × 4.60 mm i.d., 5 µm) with a mobile phase containing 0.3 % formic acid solution and methanol (v/v, 3:7; flow rate, 1.0 mL/min). UV absorption responses at 236 nm were linear over a wide concentration range from 50 µg/mL to the detection limits of 3.3 µg/L for valsartan and 1.5 µg/L for irbesartan. The effective parameters on IL‐DLLME, such as ionic liquid types and their amounts, disperser solvent types and their volume, pH of the sample and extraction time were studied and optimized. The developed IL‐DLLME‐HPLC was successfully applied for evaluation of the urine irbesartan and valsartan profile following oral capsules administration. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
《Analytical letters》2012,45(5):853-870
Abstract

Two‐component mixtures of felodipine (FLD) and ramipril (RMP) were assayed by derivative UV spectrophotometry, spectrofluorometry, and high performance liquid chromatography (HPLC). The spectrophotometric methods included a zero‐crossing first‐ and second‐order derivative procedure and a derivative compensation technique for the determination of binary mixtures with overlapping spectra. The spectrofluorometric method was based on first‐ and second‐order derivatives of the emission spectra (zero‐crossing point). Results from these methods were compared with those obtained by an exclusively developed isocratic reversed phase HPLC method. A reversed‐phase Adsorbosil DS analytical column, with methanol‐acetonitrile‐water (50∶30∶20, v/v) mobile phase at a flow rate of 1.5 ml/min, was used with a UV detector. The temperature was set at 25±0.2°C. Results obtained by the spectrophotometric and spectrofluorometric methods were comparable to those obtained by the HPLC method, as far as analysis of variance (ANOVA) test results were concerned. It is concluded that the developed methods are equally accurate, sensitive, and precise; with direct and simple application to pharmaceutical formulations of felodipine and ramipril combination, without interference from common pharmaceutical adjuvants.  相似文献   

10.
This study describes a comparison between LC‐UV and LC–MS method for the simultaneous analyses of a few disease‐modifying agents of multiple sclerosis. Quantitative determination of fampridine (FAM), teriflunomide (TFM) and dimethyl fumarate (DMF) was performed in human plasma with the recovery values in the range of 85–115%. A reversed‐phase high‐performance liquid chromatography (HPLC) with UV as well as MS detection is used. The method utilizes an XBridge C18 silica column and a gradient elution with mobile phase consisting of ammonium formate and acetonitrile at a flow rate of 0.5 mL min?1. The method adequately resolves FAM, TFM and DMF within a run time of 15 min. Owing to low molecular weights, the estimation of DMF and FAM is more versatile in UV than MS detection. With LC‐UV, the detection limits of FAM, TFM and DMF were 0.1, 0.05, 0.05 μg and the quantification limit for all the analytes was 1 μg. With LC–MS, the detection and quantification limits for all of the analytes were 1 and 5 ng, respectively. The two techniques were completely validated and shown to be reproducible and sensitive. They were applied to a pharmacokinetic study in rats by a single oral dose. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
This paper reports the optimization of the on‐line coupling of 2,2′‐azinobis(3‐ethylbenzothiazoline)‐6‐sulfonic acid based radical scavenging assays with reversed‐phase high‐performance liquid chromatography. The residence time in the reactor was reduced to 6.4 s to ensure minimal peak broadening and loss of separation. Peak capacity losses between compound detection and measurement of the radical scavenging potential were reduced to 10% and lower on coupled column systems. The methodology was successfully applied for the detection of the scavenging activity of molecules encompassing a broad hydrophobicity range. The method shows promise for the assessment of low‐molecular‐weight polyphenols in red wine by coupled‐column high‐resolution high‐performance liquid chromatography with mass spectrometry analysis.  相似文献   

12.
Thin silica gel layers impregnated with optically pure l ‐glutamic acid were used for direct resolution of enantiomers of (±)‐isoxsuprine in their native form. Three chiral derivatizing reagents, based on DFDNB moiety, were synthesized having l ‐alanine, l ‐valine and S‐benzyl‐l ‐cysteine as chiral auxiliaries. These were used to prepare diastereomers under microwave irradiation and conventional heating. The diastereomers were separated by reversed‐phase high‐performance liquid chromatography on a C18 column with detection at 340 nm using gradient elution with mobile phase containing aqueous trifluoroacetic acid and acetonitrile in different compositions and by thin‐layer chromatography (TLC) on reversed phase (RP) C18 plates. Diastereomers prepared with enantiomerically pure (+)‐isoxsuprine were used as standards for the determination of the elution order of diastereomers of (±)‐isoxsuprine. The elution order in the experimental study of RP‐TLC and RP‐HPLC supported the developed optimized structures of diastereomers based on density functional theory. The limit of detection was 0.1–0.09 µg/mL in TLC while it was in the range of 22–23 pg/mL in HPLC and 11–13 ng/mL in RP‐TLC for each enantiomer. The conditions of derivatization and chromatographic separation were optimized. The method was validated for accuracy, precision, limit of detection and limit of quantification. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

13.
A simple and specific analytical method was developed and tested for the determination of sulforaphane in broccoli by‐products. The method includes the optimization of the conversion of glucoraphanin to sulforaphane, followed by purification of extracts using solid‐phase extraction and high‐performance liquid chromatography (HPLC) analysis. The response surface methodology was used to find optimum conditions for the preparation and purification procedure. Chromatographic conditions for reversed‐phase HPLC with UV photodiode array detection were as follows: column, Exil ODS C18, 25 × 0.46 cm, 5 μm; column temperature, 36°C; mobile phase, a 30 : 70 (v/v) mixture of acetonitrile:water; flow rate, 0.6 mL/min. The detection wavelength was UV 202 nm. Under these conditions, excellent linearity was obtained (r2 = 1), and the overall recovery was 97.5 and 98.1% for fresh florets and lyophilized florets, respectively. The precision results showed that the relative standard deviation of the repeatability for florets fresh and lyophilized was 3.0 and 4.0%, respectively. Sulforaphane contents were determined in the edible portion of fresh broccoli, and broccoli crop remains. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
It is difficult to identify unknown impurities in nucleotide analogues by mass spectrometry because mass‐spectrometry‐incompatible mobile phases need to be used to separate the major ingredient from impurities. In this study, vidarabine monophosphate was selected, and unknown impurities were identified by online heart‐cutting two‐dimensional high‐performance liquid chromatography and linear ion trap mass spectrometry. The one‐dimensional reversed‐phase column was filled with a mobile phase containing nonvolatile salt. In two‐dimensional high‐performance liquid chromatography, we used an Acclaim Q1 column with volatile salt, and the detection wavelength was 260 nm. The mass spectrum was scanned in positive‐ and negative‐ion mode. The online heart‐cutting and online demineralization technique ensured that the mobile phase was compatible with mass spectrometry; seven impurities were identified by MS2 and MS3 fragments. The mass fragmentation patterns of these impurities were investigated. The two isomers were semiprepared and complemented by nuclear magnetic resonance. The results were further compared with those of normal‐phase high‐performance liquid chromatography with mass spectrometry. The online heart‐cutting two‐dimensional high‐performance liquid chromatography with mass spectrometry was superior in identifying more impurities. The method solves the problem of incompatibility between the mobile phase and mass spectrometry, so it is suitable for identifying unknown impurities. This method may also be used for investigating impurities in other nucleotide analogues.  相似文献   

15.
The use of blood spot collection cards is a simple way to obtain specimens for therapeutic drug monitoring, assessing adherence to medications and preventing toxicity in a clinical setting. A high‐throughput liquid chromatography–electrospray ionization mass spectrometric (LC‐ESI‐MS) method for determination of rifaximin on dried blood spots (DBS) was developed and validated. It involves solvent extraction of a punch of DBS followed by reversed‐phase LC on a monolithic column consisting of a silica rod with bimodal pore structure and detection by ESI‐MS. Rifampicin was used as an internal standard (IS). The run time was within 5.0 min with a very low back‐pressure at a flow rate of 0.5 mL/min. The assay was linear from 0.1 to 10 ng/mL. The mean recovery was 98.42%. The developed method is very simple, rapid and useful for clinical applications. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
Low‐temperature high‐performance liquid chromatography, in which a loop injector, column, and detection cell were refrigerated at –35ºC, using liquid carbon dioxide as the mobile phase was developed. Small organic compounds (polyaromatic hydrocarbons, alkylbenzenes, and quinones) were separated by low‐temperature high‐performance liquid chromatography at temperatures from –35 to –5ºC. The combination of liquid carbon dioxide mobile phase with an octadecyl‐silica (C18) column provided reversed phase mode separation, and a bare silica‐gel column resulted in normal phase mode separation. In both the cases, nonlinear behavior at approximately –15ºC was found in the relationship between the temperature and the retention factors of the analytes (van't Hoff plots). In contrast to general trends in high‐performance liquid chromatography, the decrease in temperature enhanced the separation efficiency of both the columns.  相似文献   

17.
董影杰  于泓  王婧菲  黄旭 《分析化学》2011,39(8):1251-1255
建立了四甲基铵根离子的反相高效液相色谱-间接紫外检测分析法.以ZORBAX ODS反相色谱柱为分离柱,采用间接紫外检测方法,考察了紫外检测波长和离子液体+有机溶剂(乙腈、甲醇)流动相对分离和测定四甲基铵根离子的影响.最佳色谱条件为:以80% 1-乙基-3-甲基咪唑四氟硼酸盐水溶液(0.5 mmol/L,乙酸调pH 3....  相似文献   

18.
Atenolol, nadolol, metoprolol, bisoprolol and betaxolol were simultaneously determined in groundwater samples by large‐volume injection coupled‐column reversed‐phase liquid chromatography with fluorescence detection (LVI‐LC‐LC‐FD) and liquid chromatography‐time‐of‐flight mass spectrometry (LC‐TOF‐MS). The LVI‐LC‐LC‐FD method combines analyte isolation, preconcentration and determination into a single step. Significant reductions in costs for sample pre‐treatment (solvent and solid phases for clean up) and method development times are also achieved. Using LC‐TOF‐MS, accurate mass measurements within 3 ppm error were obtained for all of the β‐blockers studied. Empirical formula information can be obtained by this method, allowing the unequivocal identification of the target compounds in the samples. To increase the sensitivity, a solid‐phase extraction step with Oasis MCX cartridge was carried out yielding recoveries of 79–114% (n=5) with RSD 2–7% for the LC‐TOF‐MS method. SPE gives a high purification of β‐blockers compared with the existing methods. A 100% methanol wash was allowed for these compounds with no loss of analytes. Limit of quantification was 1–7 ng/L for LVI‐LC‐LC‐FD and 0.25–5 ng/L for LC‐TOF‐MS. As a result of selective extraction and effective removal of coextractives, no matrix effect was observed in LVI‐LC‐LC‐FD and LC‐TOF‐MS analyses. The methods were applied to detect and quantify β‐blockers in groundwater samples of Almería (Spain).  相似文献   

19.
In this study, a simple, rapid, and sensitive method for the determination of nitrite (NO2?) in food samples by high‐performance liquid chromatography with fluorescence detection in acidic conditions had been developed. The derivatization of the nitrite with 2,3‐diaminonaphthalene was performed in acidic conditions to yield the highly fluorescent 2,3‐naphthotriazole, which was directly analyzed by high‐performance liquid chromatography with fluorescence detection without adjusting the solution to alkaline. The analysis column was reversed‐phase C8 column. A constant flow rate of 1.0 mL/min was employed using water/acetonitrile as the mobile phase in isocratic mode (70:30, v/v). Fluorescence was monitored with excitation at 375 nm and emission at 415 nm. The standard calibration curves were linear for nitrite in different matrixes in the concentration range of 0–100 μg/L, and the correlation coefficients ranged from 0.9978 to 0.9998. The limits of detection and quantification were in the ranges of 0.012–0.060 and 0.040–0.20 mg/kg, respectively. The recoveries of nitrite from samples spiked at three different concentrations were 74.0–113.2%, and the relative standard deviations of the recovery results (n = 6) were 1.67–10.8%. The proposed method has good repeatability and is very sensitive and simple. It has been successfully used to determine nitrite in foods.  相似文献   

20.
The simultaneous determination of lactate and pyruvate in sweat has been performed using reversed phase high‐performance liquid chromatography (RP‐HPLC) with UV detection at 220 nm. The calibration curves were linear in the investigated range 0.3 ‐ 350 mm of lactate, 0.003‐ 1 mm of pyruvate. The sensitivity was good with a limit of detection of 0.03 mm for lactate and 0.001 mm for pyruvate. Recoveries evaluated for the entire procedure were 102 ± 0.1 and 96 ± 0.1for lactate and pyruvate, respectively. The method was successfully applied to analysis of sweat in 8 athletes at rest (pilocarpine sweating) and during physical exercise. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号