首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 156 毫秒
1.
Gas chromatography in combination with electron capture negative ion mass spectrometry (GC/ECNI‐MS) is a sensitive method for the determination of polybrominated compounds in environmental and food samples via detection of the bromide ion isotopes m/z 79 and 81. The standard reagent gas for inducing chemical ionization in GC/ECNI‐MS is methane. However, the use of methane has some drawbacks as it promotes carbonization of the filament and ion source. In this study, we explored the suitability of nitrogen as reagent gas for the determination of brominated flame retardants (polybrominated diphenyl ethers (PBDEs), polybrominated biphenyls (PBBs), allyl‐2,4,6‐tribromophenyl ether (ATE) and 2,3‐dibromopropyl‐2,4,6‐tribromophenyl ether (DPTE)) and halogenated natural products (for instance, methoxylated tetrabrominated diphenylethers and polybrominated hexahydroxanthene derivatives). An ion source temperature of 250°C and a nitrogen pressure of 7 Torr in the ion source gave the highest response for m/z 79 and 81 of virtually all investigated polybrominated compounds. Using these conditions, nitrogen‐mediated GC/ECNI‐MS usually gave higher sensitivity than the method with methane previously used in our lab. In addition, the ion source was not contaminated to the same degree and the lifetime of the filament was significantly increased. Moreover, the response factors of the different polybrominated compounds with the exception of 2,4,6‐tribromophenol were more uniform than with methane. Nitrogen is available at very high purity at relatively low price. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
Polybrominated organic compounds are ubiquitous throughout the environment. This generic term comprises several classes of brominated flame retardants (e.g., polybrominated diphenyl ethers, polybrominated biphenyls, hexabromocyclododecane, dibromopropyltribromophenyl ether, 1,2-bis(2,4,6-tribromophenoxy)ethane) as well as a range of marine halogenated natural products (HNPs). Here we present gas chromatography retention times and elution orders (on DB-5) of 122 polybrominated compounds that may be found in food and environmental samples. Organobromine compounds in fish samples determined with gas chromatography interfaced to electron-capture negative ion mass spectrometry (GC/ECNI-MS) are discussed. The environmental relevance and important mass spectrometric features of the compounds are described as well. Our database aims to support the closer inspection and identification of peaks in gas chromatograms and to initiate dedicated screening for less frequently studied organobromines in samples.  相似文献   

3.
采用全二维气相色谱/飞行时间质谱(GC×GC-TOFMS),建立了鱼肉样品中含卤有机污染物的定性和定量分析方法.鱼肉样品用正己烷丙酮(1∶1,V/V)提取,凝胶色谱和复合硅胶柱净化,浓缩富集,全二维气相色谱联用飞行时间质谱(DB-5MS毛细管色谱柱联HT-8色谱柱)检测.软件自动识别后,经三步筛查,共鉴定出含氯或溴化合物72种,其中包括33种多氯联苯,9种有机氯农药,4种多溴联苯醚,4种DDT代谢产物,2种氯代茴香醚,2种氯苯乙烯,1种氯代茴香硫醚及1种甲基三氯生.另外,从质谱信息上看,有16种化合物明显含氯或含溴,但是因为缺少必要的谱库信息不能准确识别.采用外标定量法,对鱼肉样品中检出的主要的10种多氯联苯和1种多溴联苯醚进行了准确定量分析.  相似文献   

4.
This article reviews recent literature on the analysis of brominated flame retardants (BFRs) and brominated natural compounds (BNCs). The main literature sources are reviews from the last five years and research articles reporting new analytical developments published between 2003 and 2006. Sample pretreatment, extraction, clean-up and fractionation, injection techniques, chromatographic separation, detection methods, quality control and method validation are discussed. Only few new techniques, such as solid-phase microextraction (SPME) or pressurized liquid extraction (PLE), have been investigated for their ability of combining the extraction and clean-up steps. With respect to the separation of BFRs, the most important developments were the use of comprehensive two-dimensional gas chromatography for polybrominated diphenyl ethers (PBDEs) and the growing tendency for liquid-chromatographic techniques for hexabromocyclododecane (HBCD) stereoisomers and of tetrabromobisphenol-A (TBBP-A). At the detection stage, mass spectrometry (MS) has been developed as well-established and reliable technology in the identification and quantification of BFRs. A growing attention has been paid to quality assurance. Interlaboratory exercises directed towards BFRs have grown in popularity and have enabled laboratories to validate analytical methods and to guarantee the quality of their results. The analytical procedures used for the identification and characterization of several classes of BNCs, such as methoxylated polybrominated diphenyl ethers (MeO-PBDEs) (also metabolites of PBDEs), halogenated methyl or dimethyl bipyrroles (DBPs), are reviewed here for the first time. These compounds were generally identified during the routine analysis of BFRs and have received little attention until recently. For each topic, an overview is presented of its current status.  相似文献   

5.
Gas chromatography coupled to ion trap tandem mass spectrometry (GC–ITMS-MS) is proposed for the analysis of methoxylated polybrominated diphenyl ethers (MeO-PBDEs) in fish and shellfish. MS–MS operating parameters related to the isolation and fragmentation of the precursor ions were optimized to achieve maximum sensitivity and selectivity. This new method allows the determination of both MeO-PBDEs and PBDEs in a single run. Low limits of detection (0.4–2.5 pg injected) and high precision (RSD < 13%) were achieved. A sample treatment based on a selective pressurized liquid extraction (PLE) using Florisil as fat retainer was applied for the analysis of these compounds in fish samples. Method limits of quantification ranged from 0.11 to 0.95 ng g−1 lipid weight for MeO-PBDEs and between 0.18 and 0.50 ng g−1 lipid weight for PBDEs. In addition, good repeatability of the whole method was achieved (RSD < 15%). The suitability of the method was evaluated by analyzing a certified reference material (SRM 1945, whale blubber) with satisfactory results. The developed method was applied to the simultaneous analysis of MeO-PBDEs and PBDEs in fish and shellfish samples from the Mediterranean Sea.  相似文献   

6.
Twenty-six methoxylated polybrominated diphenyl ethers (MeO-PBDEs) were characterized by gas chromatography (GC) on four different GC columns with different lengths and polarities, as well as by mass spectrometry using three ionization techniques, electron ionization (EI), electron capture negative ionization (ECNI) and positive ion chemical ionization (PICI). MeO-PBDE congeners with similar retention times on a nonpolar GC column were separated when analyzed on a polar GC column. EI can be used to determine the position of the methoxy substituent (ortho, meta or para) relative to the diphenyl ether oxygen in the MeO-PBDEs. The PICI ionization technique is shown to be valuable to generate structural information of the MeO-PBDEs, i.e. the degree of bromination on both the methoxy-substituted ring and the entirely brominated phenyl ring can be obtained. This structure information can also be achieved for certain MeO-PBDEs with the methoxy group in ortho position to the diphenyl ether bond in ECNI mode. Like other brominated compounds ECNI is preferable when analyzing environmental samples for quantification of MeO-PBDEs because of the formation of bromide ions, which enables low detection limits.  相似文献   

7.
We successfully detected halogenated compounds from several kinds of environmental samples by using a comprehensive two-dimensional gas chromatograph coupled with a tandem mass spectrometer (GC×GC-MS/MS). For the global detection of organohalogens, fly ash sample extracts were directly measured without any cleanup process. The global and selective detection of halogenated compounds was achieved by neutral loss scans of chlorine, bromine and/or fluorine using an MS/MS. It was also possible to search for and identify compounds using two-dimensional mass chromatograms and mass profiles obtained from measurements of the same sample with a GC×GC-high resolution time-of-flight mass spectrometer (HRTofMS) under the same conditions as those used for the GC×GC-MS/MS. In this study, novel software tools were also developed to help find target (halogenated) compounds in the data provided by a GC×GC-HRTofMS. As a result, many dioxin and polychlorinated biphenyl congeners and many other halogenated compounds were found in fly ash extract and sediment samples. By extracting the desired information, which concerned organohalogens in this study, from huge quantities of data with the GC×GC-HRTofMS, we reveal the possibility of realizing the total global detection of compounds with one GC measurement of a sample without any pre-treatment.  相似文献   

8.
The separation of 38 toxic and predominant polychlorinated biphenyl (PCB) congeners, 11 persistent halogenated pesticides, 1 brominated biphenyl (BB), and 8 polybrominated diphenyl ethers (PBDEs) has been optimized using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC x GC-TOFMS). A thermal desorption-programmable temperature vaporization (TD-PTV) step was used for the injection. Different column sets were investigated, and a 100% dimethylpolysiloxane (15 m x 0.25 mm i.d. x 0.25 microm film thickness) narrowbore capillary column coupled to a high temperature (8% phenyl)-polycarborane-siloxane (2 m x 0.10 mm i.d. x 0.10 microm film thickness) microbore column set was selected. Of the 58 compounds investigated, only one pair of PCBs was not resolved. All other analytes were either baseline separated into the chromatographic plane or were virtually separated using the deconvolution capability of the TOFMS.  相似文献   

9.
李健  王翼飞  周显青  施致雄 《分析化学》2016,(11):1742-1747
采用索氏提取、凝胶渗透色谱和固相萃取技术作为前处理方法,建立乳制品中6种新型溴系阻燃剂、8种多溴联苯醚、四溴双酚A和α、β、γ-六溴环十二烷异构体共18种溴系阻燃剂的同时提取与净化方法,并结合气相色谱-负化学源质谱法(GC-NCI/MS)和高效液相色谱-电喷雾电离-串联质谱法(HPLC-ESI-MS/MS)进行检测。奶样经冷冻干燥后以正己烷-丙酮(1:1, V/V)索氏提取,采用凝胶渗透色谱结合酸化硅胶柱净化,随后以LC-Si固相萃取柱分离气相和液相待测物。以GC-NCI/MS测定6种新型溴系阻燃剂和8种多溴联苯醚,以HPLC-MS/MS检测四溴双酚A和六溴环十二烷异构体,内标法定量。结果表明,以空白牛奶样品为加标基质,多数待测物平均回收率为80.1%~114.7%,方法具有良好的精密度(多数待测物相对标准偏差( RSD)在0.87%~14.9%)和灵敏度(检出限在0.2~119.2 pg/g之间),可满足乳制品中多种溴系阻燃剂同时提取、净化和检测需求。  相似文献   

10.
In the presented study, comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC?×?GC-TOFMS) was shown to be a powerful tool for the simultaneous determination of various groups of contaminants including 18 polychlorinated biphenyls (PCBs), seven polybrominated diphenyl ethers (PBDEs), and 16 polycyclic aromatic hydrocarbons (PAHs). Since different groups of analytes (traditionally analyzed separately) were included into one instrumental method, significant time savings were achieved. Following the development of an integrated sample preparation procedure for an effective and rapid isolation of several groups of contaminants from fish tissue, the GC?×?GC-TOFMS instrumental method was optimized to obtain the best chromatographic resolution and low quantification limits (LOQs) of all target analytes in a complex mixture. Using large-volume programmable temperature vaporization, the following LOQs were achieved-PCBs, 0.01-0.25 μg/kg; PBDEs, 0.025-5 μg/kg; PAHs 0.025-0.5 μg/kg. Furthermore, several capillary column combinations (BPX5, BPX50, and Rxi-17Sil-ms in the first dimension and BPX5, BPX50, Rt-LC35, and HT8 in the second dimension) were tested during the experiments, and the optimal separation of all target analytes even of critical groups of PAHs (group (a): benz[a]anthracene, cyclopenta[cd]pyrene and chrysene; group (b): benzo[b]fluoranthene, benzo[j]fluoranthene and benzo[k]fluoranthene; group (c): dibenz[ah]anthracene, indeno[1,2,3-cd]pyrene and benzo[ghi]perylene) was observed on BPX5?×?BPX50 column setup. Moreover, since the determination of target analytes was performed using TOFMS detector, further identification of other non-target compounds in real life samples was also feasible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号