首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 221 毫秒
1.
As a popular detection model, the fluorescence “turn-off” sensor based on quantum dots (QDs) has already been successfully employed in the detections of many materials, especially in the researches on the interactions between pesticides. However, the previous studies are mainly focused on simple single track or the comparison based on similar concentration of drugs. In this work, a new detection method based on the fluorescence “turn-off” model with water-soluble ZnCdSe and CdSe QDs simultaneously as the fluorescent probes is established to detect various pesticides. The fluorescence of the two QDs can be quenched by different pesticides with varying degrees, which leads to the differences in positions and intensities of two peaks. By combining with chemometrics methods, all the pesticides can be qualitative and quantitative respectively even in real samples with the limit of detection was 2 × 10−8 mol L−1 and a recognition rate of 100%. This work is, to the best of our knowledge, the first report on the detection of pesticides based on the fluorescence quenching phenomenon of double quantum dots combined with chemometrics methods. What's more, the excellent selectivity of the system has been verified in different mediums such as mixed ion disruption, waste water, tea and water extraction liquid drugs.  相似文献   

2.
Monomethylarginine, asymmetric dimethylarginine and symmetric dimethylarginine were separated on a Wakopak Combi ODS with an acetonitrile–100 mm potassium phosphate buffer (pH 7.0; 1:1, v/v). Dimethylarginines were derived from o‐phthalaldehyde for the fluorescence detector and from 6‐ferrocenyl‐1‐hexanethiol for the electrochemical detector. The detection limits of the dimethylarginines in spiked plasma were 0.3–0.5 pmol by electrochemical detection and 1–2 pmol by fluorescence detection. The detection limits were improved over 30 times by electrochemical detection and 10 times by fluorescence detection compared with previous reports. In previous derivatization liquid chromatography, the reaction solutions, o‐phthalaldehyde, 2‐mercaptethanol and dimethylarginines were unstable and required quick derivatization at 4°C. By our proposed pre‐column methods, the dimethylarginines were derivatized at room temperature and the fluorescent products were stable for 6 h. The manipulation performance was greatly advanced compared with previous LC reports. This is the first report on stable and sensitive dimethylarginines by dual detection. The selectivity was also improved by dual detection. The proposed method was applied to preliminary monitoring of dimethylargines in plasma and urine. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
In this study, a simple analytical method for the determination of γ‐aminobutyric acid, gabapentin, and baclofen by using high‐performance liquid chromatography with fluorescence detection was developed. An amidogen‐reactive fluorescence labeling reagent, 4‐(carbazole‐9‐yl)‐benzyl chloroformate was first used to sensitively label these analytes. The completed labeling of these analytes can be finished rapidly only within 5 min at the room temperature (25°C) to form 4‐(carbazole‐9‐yl)‐benzyl chloroformate labeled fluorescence derivatives. These labeled derivatives expressed strong fluorescence property with the maximum excitation and emission wavelengths of 280 and 380 nm, respectively. The labeled derivatives were analyzed using a reversed‐phase Eclipse SB‐C18 column within 10 min with satisfactory shapes. Excellent linearity (R2 > 0.995) for all analytes was achieved with the limits of detection and the limits of quantitation in the range of 0.25?0.35 and 0.70?1.10 μg/L, respectively. The proposed method was used for the simultaneous determination of γ‐aminobutyric acid and its analogs in human serum with satisfactory recoveries in the range of 94.5–97.5%.  相似文献   

4.
As an important metal element, aluminium has a significant impact on the environment and human health, and thus the detection of Al3+ has become the subject of much research. We synthesized a Ni(II)‐based metal–organic gel (Ni‐MOG), which can serve as an Al3+ fluorescence sensor with high selectivity and sensitivity, the limit of detection being calculated to be 0.5 μM. In addition, a composite film was further fabricated by hybridization of this Ni‐MOG with poly(vinyl alcohol). The composite film produced a rapid fluorescence response to Al3+ solutions at concentrations above 5 × 10?5 M in 5 min. The Ni‐MOG composite film can also be successfully applied for the sensitive detection of Al3+ in real samples of tap water and seawater. The effective detection of Al3+ described in this contribution provides a new insight into water quality monitoring and has promising application value.  相似文献   

5.
As a new detection model, the reversible fluorescence “turn-off-on” sensor based on quantum dots (QDs) has already been successfully employed in the detections of many biochemical materials, especially in the researches on the interactions between anticancer drugs. The previous studies, however, mainly focused on simple-structured oligonucleotides and Calf thymus DNA. G-quadruplex, an important target for anti-cancer drug with special secondary structure, has been stimulating increasing research interests. In this paper, we report a new detection method based on the fluorescence “turn-off-on” model with water-soluble ZnCdSe QDs as the fluorescent probe, to analyze the interactions between anticancer drug (N-methyl-4-pyridyl) porphyrin (TMPyP) and nucleic acid, especially the G-quadruplex. The fluorescence of QDs can be quenched by TMPyP via photo-induced electron transfer and fluorescence resonance energy transfer, while on the other hand, the combination between TMPyP and G-quadruplex releases QDs from their quenchers and thus recovers the fluorescence. Most importantly, the fluorescence “turn-off-on” model has been employed, for the first time, to analyze the impacts of special factors on the interaction between TMPyP and G-quadruplex. The excellent selectivity of the system has been verified in the studies of the interactions between TMPyP and different DNAs (double-stranded DNA, single-stranded G-quadruplex, and different types of G-quadruplexes) in Na+ or K+-containing buffer.  相似文献   

6.
7.
A highly sensitive high-performance liquid chromatographic method with fluorescence detection has been developed for determination of vitamin B1. Vitamin B1 was converted into a fluorescent compound by treatment with hydrogen peroxide–horseradish peroxidase and the derivative was subsequently analyzed by HPLC on a Waters Spherisorb ODS2 column (250 mm×4.6 mm ID, 5 μm) with 40:60 methanol–pH 8.5 acetate buffer solution as mobile phase and fluorescence detection at 440 nm (with excitation at 375 nm). The calibration graph was linear from 5.00×10−10 mol L−1 to 5.00×10−7 mol L−1 for vitamin B1 with a correlation coefficient of 0.9991 (n=9). The detection limit was 1.0×10−10 mol L−1. The method was successfully used for determination of vitamin B1 at pg mL−1 levels in microalgal fermentation media and seawater after solid-phase extraction. Recovery was from 89 to 110% and the relative standard deviation was in the range 1.1 to 4.3%.  相似文献   

8.
Chiral analysis of dl ‐amino acids was achieved by micellar electrokinetic chromatography coupled with UV‐excited fluorescence detection. The fluorescent reagent (+)‐1‐(9‐fluorenyl)ethyl chloroformate was employed as chiral amino acid derivatizing agent and sodium dodecyl sulfate served as pseudo‐stationary phase for separating the formed amino acid diastereomers. Sensitive analysis of (+)‐1‐(9‐fluorenyl)ethyl chloroformate‐amino acids was achieved applying a xenon‐mercury lamp for ultraviolet excitation, and a spectrograph and charge‐coupled device for wavelength‐resolved emission detection. Applying signal integration over a 30 nm emission wavelength interval, signal‐to‐noise ratios for derivatized amino acids were up to 23 times higher as obtained using a standard photomultiplier for detection. The background electrolyte composition (electrolyte, pH, sodium dodecyl sulfate concentration, and organic solvent) was studied in order to attain optimal chemo‐ and enantioseparation. Enantioseparation of 12 proteinogenic dl ‐amino acids was achieved with chiral resolutions between 1.2 and 7.9, and detection limits for most derivatized amino acids in the 13–60 nM range (injected concentration). Linearity (coefficients of determination > 0.985) and peak‐area and migration‐time repeatabilities (relative standard deviations lower than 2.6 and 1.9%, respectively) were satisfactory. The employed fluorescence detection system provided up to 100‐times better signal‐to‐noise ratios for (+)‐1‐(9‐fluorenyl)ethyl chloroformate‐amino acids than ultraviolet absorbance detection, showing good potential for d ‐amino acid analysis.  相似文献   

9.
DNA methylation is a significant epigenetic modification and the methods for the detection of DNA methyltransferase (MTase) activity are important due to aberrant methylation closely related to the occurrence of cancer. In this study, a simple and rapid microchip electrophoresis (ME) coupled with LED‐induced fluorescence (LEDIF) method was presented for the detection of Dam MTase activity. This strategy was based on methylation‐sensitive endonuclease DpnⅡ which could recognize the same specific site 5′‐GATC‐3′ with Dam MTase in double‐stranded DNA (dsDNA). The adenines in the specific site could be methylated by Dam MTase, then the special site could not be digested by DpnⅡ. Both methylated dsDNA and unmethylated dsDNA could be analyzed by ME‐LEDIF after stained by SYBR gold. The results showed the fluorescence intensities of methylated dsDNA were directly proportional to Dam MTase activities in the range of 0.5–20 U/mL with a detection limit of 0.12 U/mL. Furthermore, the method could successfully be applied to evaluation experiments of Dam MTase inhibitors. The results confirmed the ME‐LEDIF method is a promising approach for inhibitors screening of DNA MTase and development of anticancer drugs  相似文献   

10.
New terphenyl-based derivative 4 with pyrene as a fluorophore has been synthesized and examined for its cation recognition abilities toward various cations by NMR and fluorescence spectroscopy. The results show that it has very high binding affinity (log β = 5.12) and selectivity for mercury. A fluorescence enhancement of 375% was observed for the 4-Hg2+ system in THF. A Hg2+ selective electrode (ISE) was also formed which showed excellent selectivity over all the other cations tested. The lower limit of detection is 2.1 × 10−6 M.  相似文献   

11.
Acrolein is a major unsaturated aldehyde that is generated during the lipid peroxidation process. The measurement of acrolein in biological samples should be useful to estimate the degree of lipid peroxidation and to evaluate the effect of hazardous properties of acrolein on human health. In this study, a highly sensitive and selective high‐performance liquid chromatography with fluorescence detection method was developed for the determination of acrolein in human serum. The proposed method involves the pre‐column fluorogenic derivatization of acrolein with 1,2‐diamino‐4,5‐dimethoxybenzene (DDB) as a reagent. The fluorescent derivative of acrolein could be detected clearly without any interfering reagent blank peaks because DDB does not have intrinsic fluorescence itself, and the detection limit was 10 nM (signal‐to‐noise ratio = 3). The proposed method could selectively detect acrolein in human serum with a simple protein precipitation treatment. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
A microchip capillary electrophoresis system with highly sensitive fluorescence detection is reported. The system was successfully constructed using an inverted fluorescence microscope, a highly sensitive photon counter, a photomultiplier tube (PMT) and a capillary electrophoresis microchip. This system can be applied to the fluorescence detection with various wavelengths (300-600 nm). Different fluorescence reagents require different excitation wavelengths. The wavelengths of UV light (300-385 nm), blue light (450-480 nm) and green light (530-550 nm) are employed to excite Titan yellow, fluorescence-5-isothiocyanate (FITC) and Rhodamine 6G, respectively. The detection limit (S/N = 3) of FITC is 7 × 10−10 M, which is 2-3 orders of magnitude lower than that obtained with the lamp-based fluorescence and PMT detection system and approaches the data gained by the laser-induced fluorescence detection. The linear relationship is excellent within the range of concentration 1.3 × 10−9 to 6.5 × 10−8 M FITC. It offers a new method to widen the application of the lamp-based fluorescence detection.  相似文献   

13.
A novel probe incorporating quaternized 4-pyridinium group into a BODIPY molecule was synthesized and studied for the selective detection of fluoride ions (F) in aqueous solution. The design was based on a fluoride-specific desilylation reaction and the “Turn-On” fluorescent response of probe 1 to F was ascribed to the inhibition of photoinduced electron transfer (PET) process. The probe displayed many desired properties such as high specificity, appreciable solubility, desirable response time and low toxicity to mammalian cells. There was a good linearity between the fluorescence intensity and the concentrations of F in the range of 0.1–1 mM with a detection limit of 0.02 mM. The sensing mechanism was confirmed by the NMR, electrospray ionization mass spectrum, optical spectroscopy and the mechanism of “Turn-On” fluorescent response was also determinated by a density functional theory (DFT) calculation using Gaussian 03 program. Moreover, the probe was successfully applied for the fluorescence imaging of F in human epithelial lung cancer (A549) cells and alveolar type II (ATII) cells under physiological conditions.  相似文献   

14.
Cardiolipin (CL) plays an essential role as a marker for cell apoptosis. Quantitative detection of phospholipids (PLs) by UV absorbance is problematic due to the presence of few double bonds in the structure. Although 10-N-nonyl acridine orange (NAO) has been utilized for fluorescent visualization of liposomes and mitochondria through its interaction with CL, in this work, we have developed a specific fluorescent method for CL in solution using NAO. The interaction of sodium n-dodecyl sulfate (SDS), used to treat cells prior to lipid extraction, and other PLs found in cell membranes such as phosphatidic acid (PA), phosphatidylcholine (PC), phosphatidylethanolamine (PE), phosphatidylglycerol (PG), phosphatidiylserine (PS), and sphingomyelin (SM) with NAO is investigated. The fluorescence intensity of the 0.5 μM NAO signal is strongly quenched by SDS below 25% methanol in water but with a methanol content above 50%, no quenching of NAO by SDS is observed. No fluorescence quenching of NAO with a 50% methanol/50% water solvent by the previously mentioned PLs or 4–20 μM cholesterol with the exception of PG at above 8 μM is noted. Using this 50% methanol/50% water solvent, the fluorescence signal due to the NAO–CL interaction is quite stable from 3 to at least 15 min. With excitation and emission wavelengths set at 518 and 530 nm, respectively, 20 μM NAO provides an inverse linear fluorescence response at 0.2–10 μM CL with a correlation coefficient of 0.9929. The detection limit is 0.2 μM and the limit of quantification is 0.6 μM. Structurally analogous acridine orange and phenosafranin dyes are less effective as fluorescent probes for CL. The CL in the whole cell and membrane samples is quantitatively determined by standard addition to range from 0.2 to 1.5 μM. The level of CL in cell membrane samples, previously subjected to staurosporine which initiates cell apoptosis, is increased but not significantly through use of the t-test.  相似文献   

15.
A novel fluorescent probe based on fluoresceinyloxime was developed for detection of such organophosphorous compounds as nerve agents. The probe underwent an abnormal cascade reaction from oxime to nitrile via isoxazole in aqueous solvent and displayed a highly selective fluorescence response to diethylchlorophosphate (DCP) with the detection limit of 10 nM DCP in HEPES buffer.  相似文献   

16.
Two new imide-based crystalline, porous, and chemically stable covalent organic frameworks (COFs) (TpBDH and TfpBDH) have been successfully synthesized employing solvothermal crystallization route. Furthermore, thin layered covalent organic nanosheets (CONs) were derived from these bulk COFs by the simple liquid phase exfoliation method. These 2D CONs showcase increased luminescence intensity compared to their bulk counterparts (COFs). Notably, TfpBDH-CONs showcase good selectivity and prominent, direct visual detection towards different nitroaromatic analytes over TpBDH-CONs. Quite interestingly, TfpBDH-CONs exhibit a superior “turn-on” detection capability for 2,4,6-trinitrophenol (TNP) in the solid state, but conversely, they also show a “turn-off” detection in the dispersion state. These findings describe a new approach towards developing an efficient, promising fluorescence chemosensor material for both visual and spectroscopic detection of nitroaromatic compounds with very low [10–5 (M)] analyte concentrations.  相似文献   

17.
One of the most commonly employed detection methods in microfluidic research is fluorescence detection, due to its ease of integration and excellent sensitivity. Many analytes though do not show luminescence when excited in the visible light spectrum, require suitable dyes. Deep‐ultraviolet (UV) excitation (<300 nm) allows label‐free detection of a broader range of analytes but also mandates the use of expensive fused silica glass, which is transparent to UV light. Herein, we report the first application of label‐free deep UV fluorescence detection in non‐UV transparent full‐body polymer microfluidic devices. This was achieved by means of two‐photon excitation in the visible range (λex = 532 nm). Issues associated with the low optical transmittance of plastics in the UV range were successfully circumvented in this way. The technique was investigated by application to microchip electrophoresis of small aromatic compounds. Various polymers, such as poly(methyl methacrylate), cyclic olefin polymer, and copolymer as well as poly(dimethylsiloxane) were investigated and compared with respect to achievable LOD and ruggedness against photodamage. To demonstrate the applicability of the technique, the method was also applied to the determination of serotonin and tryptamine in fruit samples.  相似文献   

18.
The fluorescence of ciprofloxacin (CIP) in HAc–NaAc buffer solution and the presence of cetyltrimethylammonium bromide (CTMAB) enhanced visibly with adding Al(III) and La(III). This enhanced fluorescence spectra were studied, and a new co-luminescence system of CIP + Al(III) + La(III) + CTMAB was discovered. There was a linear relationship between the enhanced fluorescence intensity and the concentration of CIP in the range of 0.50–80.2 μg l?1 under the optimized condition. A novel enhanced fluorescence method for the determination of trace CIP was established by using this co-luminescence system. The detection limit of the proposed method was 0.17 μg l?1 for CIP. This method is simple, rapid and sensitive. The CIP in milk samples were analyzed by the proposed method with satisfactory results. The relative standard deviation and the recovery were in ranges of 3.21–4.34% and 97.1–100.1%, respectively. The mechanism of the co-luminescence reaction and the reasons for fluorescence enhancement has been discussed.  相似文献   

19.
For the detection of the major active component of cannabis, Δ9-tetrahydrocannabinol (THC) in aqueous samples, a homogeneous competitive immunoassay based on fluorescence quenching induced by fluorescence resonance energy transfer (FRET) has been developed. The fluorescence of anti-THC-antibody, labeled with fluorescence dye DY-481XL, can be quenched after its binding to THC-BSA-quencher conjugate (bovine serum albumin coupled with THC and another fluorescence dye, DYQ-661, as quencher). This quenching effect is inhibited when the antibodies bind to free THC in aqueous sample, thus competing for binding sites with the THC-BSA-quencher conjugate. The extent of the inhibition corresponds to the concentration of THC in the samples. The assay principle is simple and the test duration is within 10 min. The detection limit for THC in buffer was 2 ng mL−1. In pooled saliva samples a detection limit of 50 ng mL−1 was achieved.  相似文献   

20.
Currently most of the fluorogenic probes are designed for the detection of enzymes which work by converting the non-fluorescence substrate into the fluorescence product via an enzymatic reaction. On the other hand, the design of fluorogenic probes for non-enzymatic proteins remains a great challenge. Herein, we report a general strategy to create near-IR fluorogenic probes, where a small molecule ligand is conjugated to a novel γ-phenyl-substituted Cy5 fluorophore, for the selective detection of proteins through a non-enzymatic process. Detail mechanistic studies reveal that the probes self-assemble to form fluorescence-quenched J-type aggregate. In the presence of target analyte, bright fluorescence in the near-IR region is emitted through the recognition-induced disassembly of the probe aggregate. This Cy5 fluorophore is a unique self-assembly/disassembly dye as it gives remarkable fluorescence enhancement. Based on the same design, three different fluorogenic probes were constructed and one of them was applied for the no-wash imaging of tumor cells for the detection of hypoxia-induced cancer-specific biomarker, transmembrane-type carbonic anhydrase IX.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号