首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Yu S  Geng J  Zhou P  Wang J  Feng A  Chen X  Tong H  Hu J 《Analytica chimica acta》2008,611(2):173-181
A new hybrid organic-inorganic monolithic column for efficient deoxyribonucleic acid (DNA) extraction was prepared in situ by polymerization of N-(β-aminoethyl)-γ-aminopropyltriethoxysilane (AEAPTES) and tetraethoxysilane (TEOS). The main extraction mechanism was based on the Coulombic force between DNA and the amino silica hybrid monolithic column. DNA extraction conditions, such as pH, ion concentration and type, and loading capacity, were optimized online by capillary electrophoresis with laser-induced fluorescence detection. Under optimal condition, a 6.0-cm monolithic column provided a capacity of 48 ng DNA with an extraction efficiency of 74 ± 6.3% (X ± RSD). The DNA extraction process on this monolithic column was carried out in a totally aqueous system for the successful purification of DNA and removal of proteins. The PBE2 plasmid could be extracted from Bacillus subtilis (B. subtilis) crude lysate within 25 min, and the purified DNA was suitable for the amplification of a target fragment by polymerase chain reaction. This study demonstrates a new attractive solid-phase support for DNA extraction to meet the increasingly miniaturized and automated trends of genetic analyses.  相似文献   

2.
A micro-solid-phase extraction (μ-SPE) device was developed by filling copper(II) isonicotinate coordination polymer (Cu(4-C5H4N-COO)2(H2O)4) into a porous polypropylene envelope, and the μ-SPE, coupling with gas chromatography (GC) with a micro-cell electron capture detector (μ-ECD), was used for extraction and determination of PBDEs in soils. Variables affecting extraction procedures, including temperature, water volume, extraction time, and desorption time, were investigated in a spiked soil, and the parameters were optimized. Under the optimal experimental conditions, the method detection limits for seven PBDEs (BDE-28, 47, 99, 100, 153, 154, and 183) were in the range of 0.026–0.066 ng g−1, and the reproducibility was satisfactory with the relative standard deviation in range of 1.3–10.1%. Good linear relationship between PBDEs concentrations and GC signals (defined as peak area) was obtained in the range between 0.1 and 200 ng g−1. The recovery of the seven PBDEs by μ-SPE varied from 70 to 90%, which was comparable to that determined by accelerated solvent extraction method. Finally, the proposed method was used to determine PBDEs in several field-contaminated soils, and it was suggested that the μ-SPE is a promising alternative microextraction technique for the detection of PBDEs in soils.  相似文献   

3.
Liu AL  He FY  Hu YL  Xia XH 《Talanta》2006,68(4):1303-1308
Rapid separation and determination of acetaminophen and its hydrolysate with end-channel electrochemical (EC) detection integrated on a plastified poly(ethylene terephthalate) (PET)-toner microchip capillary electrophoresis (CE) system was investigated. In this separation and detection system, a Pt ultramicroelectrode integrated on a three-dimensional adjustor was used as working electrode. Factors influencing the separation and detection were investigated and optimized. Results show that acetaminophen and p-aminophenol can be well separated within 84 s with R.S.D. < 1% for migration time and R.S.D. < 3.6% for detection current for both analytes. Detection limits for both analytes are determined to be 5.0 μM (S/N = 3). This method has been successfully applied to the detection of trace p-aminophenol in paracetamol tablets. The results demonstrate that the PET-toner microchips can obtain better performance than PDMS microfluidic devices but at much lower cost.  相似文献   

4.
A single-step extraction-cleanup method, including microwave-assisted extraction (MAE) and micro-solid-phase extraction (μ-SPE), was developed for the extraction of ten organophosphorus pesticides in vegetable and fruit samples. Without adding any polar solvent, only one kind of non-polar solvent (hexane) was used as extraction solvent in the whole extraction step. Absorbing microwave μ-SPE device, was prepared by packing activated carbon with microporous polypropylene membrane envelope, and used as not only the sorbent in μ-SPE, but also the microwave absorption medium. Some experimental parameters effecting on extraction efficiency was investigated and optimized. 1.0 g of sample, 8 mL of hexane and three absorbing microwave μ-SPE devices were added in the microwave extraction vessel, the extraction was carried out under 400 W irradiation power at 60 °C for 10 min. The extracts obtained by MAE-μ-SPE were directly analyzed by GC–MS without any clean-up process. The recoveries were in the range of 93.5–104.6%, and the relative standard deviations were lower than 8.7%.  相似文献   

5.
A novel high-throughput device based on 96-micro-solid phase extraction (96-μ-SPE) system was constructed for multiresidue determination of nine pesticides in aquatic samples. The extraction procedure was performed on a commercially available 96-well plate system. The extraction module consisted of 96 pieces of 1 cm × 3 cm of cylindrically shaped stainless steel meshes. The prepared meshes were fixed in a home-made polytetrafluoroethylene-based constructed ninety-six holes block for possible simultaneous immersion of meshes into the center of individual wells. Dodecyl methacrylate and ethylene glycol dimethacrylate was copolymerized as a monolithic polymer and placed in the cylindrically shaped stainless steel meshes as extracting medium. A volume of 1 mL of the aquatic sample was transferred into the 96-well plate and the 96-μ-SPE device was applied for the extraction of the selected pesticides. Subsequently, the extracted analytes were analyzed by gas chromatography–mass spectrometry. Influential parameters such as polymer synthesis conditions, sorbent-to-sorbent reproducibility, ionic strength and extraction time were optimized. Intra and inter-sorbent reproducibility on 96-μ-SPE device were evaluated and results revealed that extraction yields are rather similar. Limits of detection were below 4 μg L−1 and the coefficient of determination was satisfactory (r2 > 0.99) for all the studied analytes. The developed method was successfully applied to the extraction and determination of the selected pesticides in surface water samples.  相似文献   

6.
This paper presents a simple and low-cost method for patterning poly(dimethylsiloxane) (PDMS) barriers in porous support such as paper for the construction of flexible microfluidic paper-based analytical devices (μPADs). The fabrication method consisted of contact-printing a solution of PDMS and hexane (10:1.5 w/w) onto chromatographic paper using custom-designed rubber stamps containing the patterns of μPADs. After penetrating the paper (∼30 s), the PDMS is cured to form hydrophobic barriers. Under optimized conditions, hydrophobic barriers and hydrophilic channels with dimensions down to 949 ± 88 μm and 771 ± 90 μm (n = 5), respectively, were obtained. This resolution is well-suitable for most applications in analytical chemistry. Chemical compatibility studies revealed that the PDMS barriers were able to contain some organic solvents, including acetonitrile and methanol, and aqueous solutions of some surfactants. This find is particularly interesting given that acetonitrile and methanol are the most used solvents in chromatographic separations, non-aqueous capillary electrophoresis and electroanalysis, as well as aqueous solutions of surfactants are suitable mediums for cell lyses assays. The utility of the technique was evaluated in the fabrication of paper-based electrochemical devices (PEDs) with pencil-drawn electrodes for experiments in static cyclic voltammetry and flow injection analysis (FIA) with amperometric detection, in both aqueous and organic mediums.  相似文献   

7.
A novel hyphenated technique, namely the combination of stir bar sorptive extraction (SBSE) with isotope dilution direct analysis in real time (DART) Orbitrap™ mass spectrometry (OT-MS) is presented for the extraction of phosphoric acid alkyl esters (tri- (TnBP), di- (HDBP), and mono-butyl phosphate (H2MBP)) from aqueous samples. First, SBSE of phosphate esters was performed using a Twister™ coated with 24 μL of polydimethylsiloxane (PDMS) as the extracting phase. SBSE was optimized for extraction pH, phase ratio (PDMS volume/aqueous phase volume), stirring speed, extraction time and temperature. Then, coupling of SBSE to DART/Orbitrap-MS was achieved by placing the Twister™ in the middle of an open-ended glass tube between the DART and the Orbitrap™. The DART mass spectrometric response of phosphate esters was probed using commercially available and synthesized alkyl phosphate ester standards. The positive ion full scan spectra of alkyl phosphate triesters (TnBP) was characterized by the product of self-protonation [M + H]+ and, during collision-induced dissociation (CID), the major fragmentation ions corresponded to consecutive loss of alkyl chains. Negative ionization gave abundant [M − H] ions for both HDnBP and H2MnBP. Twisters™ coated with PDMS successfully extracted phosphate acid esters (tri-, di- and mono-esters) granted that the analytes are present in the aqueous solution in the neutral form. SBSE/DART/Orbitrap-MS results show a good linearity between the concentrations and relative peak areas for the analytes in the concentration range studied (0.1–750 ng mL−1). Reproducibility of this SBSE/DART/Orbitrap-MS method was evaluated in terms of %RSD by extracting a sample of water fortified with the analytes. The %RSDs for TnBP, HDnBP and H2MnBP were 4, 3 and 3% (n = 5) using the respective perdeuterated internal standards. Matrix effects were investigated by matrix matched calibration standards using underground water samples (UWS) and river water samples (RWS). Matrix effects were effectively compensated by the addition of the perdeuterated internal standards. The application of this new SBSE/DART/Orbitrap-MS method should be very valuable for on-site sampling/monitoring, limiting the transport of large volumes of water samples from the sampling site to the laboratory.  相似文献   

8.
Surface plasmon resonance (SPR) spectroscopy is utilized to study in real-time and, by label-free means, the reversible and quasi-irreversible adsorption of small ionic or neutral molecules, pharmaceuticals, and proteins on poly(dimethylsiloxane) (PDMS) surfaces. The SPR sensor is covered with 0.2% (w/v) PDMS in octane. During the timescale of a typical lab-on-a-chip analysis or an electrophoretic separation, it was found that small neutral components containing a hydrophobic part do not adsorb or absorb onto PDMS, while larger, water-soluble polymer-like materials like proteins generally irreversibly adsorb to PDMS. The technique can be used to monitor the kinetics of adsorption and desorption of the molecules. For the non-specific adsorption of teicoplanin to PDMS, a Langmuir-like adsorption isotherm was obtained (Kd = 32 ± 2 μmol L−1).  相似文献   

9.
We describe a simple and sensitive porous polypropylene membrane-protected micro-solid-phase extraction (μ-SPE) approach for the sample preparation and determination of carbamate pesticides in soil samples by high-performance liquid chromatography. The μ-SPE device consisted of C18 sorbent held within a porous polypropylene envelope. In order to achieve optimum performance, several extraction parameters were optimized. Under the most favorable conditions, the extraction efficiency of the μ-SPE was very high, with detection limits in the range of 0.01–0.40 ng g−1. This is more than two orders of magnitude lower than the limits obtained by the United States Environmental Protection Agency Methods 8321A and 8318. A linear relationship was obtained for each analyte in the range of 2 and 200 ng g−1. The relative standard deviation for the analysis of aged soil samples spiked at 5 ng g−1 was ≤11%. The reproducibility of separate μ-SPE device used for experiments was satisfactory (relative standard deviations ranged from 4 to 11%), indicating that the method is reliable for routine environmental analysis.  相似文献   

10.
Here, a simple new method is proposed to evaluate water for the presence of pesticides. Specifically, pesticides for golf link maintenance were used as the targets for this investigation. Water samples containing the pesticides were mixed with particulate adsorbent, after which the pesticides were extracted from the adsorbents using supercritical fluid carbon dioxide and then analyzed by gas chromatography-mass spectrometry. The recoveries of pesticides were examined with several types of adsorbents and found to be related to their octanol/water partition coefficients (Kow) for most of the adsorbents. Good recoveries were obtained when the water samples were mixed with octadecylsilane (ODS) and stylene-divinylbenzene copolymer (XAD) resins for 15 and 30 min, respectively. In the supercritical fluid extraction, extraction pressure affected the efficiency of extraction from XAD while a little effect on extraction from ODS, probably due to the internal structure of the adsorbents. The limit of detection ranged from 0.002 to 2.3 μg L−1 and the method is suitable for the measurement of golf link pesticides in μg L−1 order to 100 μg L−1. The procedure of the proposed method was simpler than the conventional solid-phase extraction method. Finally, the method presented here was used to identify pesticides present in actual wastewater from golf links.  相似文献   

11.
A cost effective and environmentally friendly extraction technique using porous membrane protected micro-solid phase extraction (μ-SPE) is described for the extraction of estrogens in cyst fluid samples obtained from cancer patients. A sorbent (ethylsilane (C2) modified silica) (20 mg) was packed in a porous polypropylene envelope (2 cm × 1.5 cm) whose edges were heat sealed to secure the contents. The μ-SPE device was conditioned with acetone and placed in a stirred (1:5) diluted cyst fluid sample solution (10 mL) to extract estrogens for 60 min. After extraction, the analytes were desorbed and simultaneously derivatized with a 5:1 mixture of acetone and N,O-bis(trimethylsilyl)-trifluoroacetamide. The extract (2 μL) was analyzed by gas chromatography–mass spectrometry. Various extraction, desorption and derivatization conditions were optimized for μ-SPE. With this simple technique, low limits of detection of between 9 and 22 ng L−1 and linear range from the detection limits up to 50 μg L−1 were achieved. The optimized method was used to extract estrogens from cyst fluid samples obtained from patients with malignant and benign ovarian tumors.  相似文献   

12.
The ability and efficiency of micro precolumns made of C30 particles, monolithic silica C18 stationary phase and quartz wool coated with C30, which act as novel solid phase absorbing materials, for the on-line enrichment of aqueous polycyclic aromatic hydrocarbons (PAHs) in microcolumn liquid chromatography (LC) was investigated. The enrichment unit was designed in such a way that micro precolumns were directly connected to a 6-port micro injection valve via fused-silica tubing (0.05 mm I.D.) in order to minimize band broadening of the samples, and the enrichment efficiency of the three materials was tested using 14 PAHs, which are selected by the US Environmental Protection Agency (US EPA), as the analytes. The separation of PAHs was evaluated by using laboratory-made C30 or ODS capillary columns and the results were compared. There were no significant differences showed from the separation of PAHs in terms of peak signal between the C30 and ODS capillary columns, but the C30 capillary column was chosen for the following experiment due to its ability to produce better repeatability than the ODS column. By using the three kinds of precolumn materials, results showed that the precolumn packed with C30 particles as well as the capillary monolithic C18 precolumns (0.1 or 0.2 mm I.D.) provided better recovery than those of the quartz wool's. As long as the recovery and separation of the PAHs were concerned, 0.1 mm I.D. monolithic C18 precolumn showed the best results and the R.S.D.s (N = 7) for the retention time, peak area and peak height were between 0.70-1.5, 2.3-5.8 and 2.4-6.6%, respectively. Large volume injection up to 0.5 mL, i.e. 2500-fold enrichment, was possible and no negative effect on the separation profile was found. The LOD (S/N = 3) were between 0.10 and 4.6 pg mL−1, while the LOQ (S/N = 10) were in the range of 0.32-15 pg mL−1, which showed that the system is comparable to many major analytical techniques and is sensitive enough for the trace analysis of PAHs in environmental samples. The system was then applied to the determination of trace PAHs present in soil sample which was randomly taken from a nearby highway.  相似文献   

13.
Malik UR  Hasany SM  Subhani MS 《Talanta》2005,66(1):166-173
The sorptive potential of sunflower stem (180-300 μm) for Cr(III) ions has been investigated in detail. The maximum sorption (≥85%) of Cr(III) ions (70.2 μM) has been accomplished using 30 mg of high density sunflower stem in 10 min from 0.001 M nitric and 0.0001 M hydrochloric acid solutions. The accumulation of Cr(III) ions on the sorbent follows Dubinin-Radushkevich (D-R), Freundlich and Langmuir isotherms. The isotherm yields D-R saturation capacity Xm = 1.60 ± 0.23 mmol g−1, β = −0.00654 ± 0.00017 kJ2 mol−2, mean free energy E = 8.74 ± 0.12 kJ mol−1, Freundlich sorption capacity KF = 0.24 ± 0.11 mol g−1, 1/n = 0.90 ± 0.04 and of Langmuir constant KL = 6800 ± 600 dm3 mol−1 and Cm = 120 ± 18 μmol g−1. The variation of sorption with temperature (283-323 K) gives ΔH = −23.3 ± 0.8 kJ mol−1, ΔS = −64.0 ± 2.7 J mol−1 K−1 and ΔG298k = −4.04 ± 0.09 kJ mol−1. The negative enthalpy and free energy envisage exothermic and spontaneous nature of sorption, respectively. Bisulphate, Fe(III), molybdate, citrate, Fe(II), Y(III) suppress the sorption significantly. The selectivity studies indicate that Cr(III), Eu(III) and Tb(III) ions can be separated from Tc(VII) and I(I). Sunflower stem can be used for the preconcentration and removal of Cr(III) ions from aqueous medium. This cheaper and novel sorbent has potential applications in analytical and environmental chemistry, in water decontamination, industrial waste treatment and in pollution abatement. A possible mechanism of biosorption of Cr(III) ions onto the sunflower stem has been proposed.  相似文献   

14.
Hydrodynamic chromatography (HDC) was used as a size classification and purification method for porous bridged ethyl hybrid (BEH) packing materials (particles) in the micron to sub-micron range. Using packed column HDC, a batch of particles with size 0.76 ± 0.26 μm was fractionated to yield classified material of 1.05 ± 0.16 μm, reducing the relative standard deviation from 33% to 15%. Subsequent chromatographic evaluation of this packing material showed significant improvement in column performance and decrease in flow resistance over the unclassified material. Comparing a column packed with the classified versus non-classified material, the effective flow resistance of the two columns was decreased by 58% and the minimum HETP for the packing material was improved from 4 to 2.5 μm.  相似文献   

15.
A carbon monolith was synthesized via a polymerization–carbonization method, styrene and divinylbenzene being adopted as precursors and dodecanol as a porogen during polymerization. The resultant monolith had bimodal porous substructure, narrowly distributed nano skeleton pores and uniform textural pores or throughpores. The carbon monolith was directly used as an extracting fiber, taking place of the coated silica fibers in commercially available solid-phase microextraction device, for the extraction of phenols followed by gas chromatography–mass spectrometry. Under the studied conditions, the calibration curves were linear from 0.5 to 50 ng mL−1 for phenol, o-nitrophenol, 2,4-dichlorophenol and p-chlorophenol. The limits of detection were between 0.04 and 0.43 ng mL−1. The recoveries of the phenols spiked in real water samples at 10 ng mL−1 were between 85% and 98% with the relative standard deviations below 10%. Compared with the commercial coated ones (e.g. PDMS, CW/DVB and DVB/CAR/PDMS), the carbon monolith-based fiber had advantages of faster extraction equilibrium and higher extraction capacity due to the superior pore connectivity and pore openness resulting from its bimodal porous substructure.  相似文献   

16.
The DNA cleavage activities of nickel(II) ion and four closely related macrocyclic nickel(II) complexes NiL1 ∼ NiL4 in the absence of any added redox cofactors are compared and the structure of NiL3 methanol solvate has been characterized by single crystal X-ray analysis, where L1 ∼ L4 are the dianions of tetraazamacrocyclic oxamido Schiff bases. In NiL3·MeOH, the macrocyclic [N4] ligand coordinates to the central Ni(II) ion forming a distorted square–planar geometry. The adjacent mononuclear molecules are linked by O–H?O hydrogen bonds and Ni?O and Ni?L van der Waals forces into 2D supramolecular structure. Agarose gel electrophoresis studies indicate that the ability of these nickel(II) complexes to cleave DNA is highly dependent upon the ligand employed. In the absence of any added oxidizing agents, only NiL3 is a relatively good DNA cleavage agent, and the process of plasmid DNA cleavage is much sensitive to ionic strength and pH value. The NiL3-mediated DNA cleavage reaction is a typical pseudo-first-order consecutive reaction, and the rate constants of 0.148 ± 0.007 h−1 (k1) and 0.0118 ± 0.0018 h−1 (k2) for the conversion of supercoiled to nicked DNA and nicked to linear DNA are obtained in presence of 0.5 mmol L−1 NiL3. The results of DNA cleavage experiments, combining with those of circular dichroism (CD) and fluorescence spectroscopy indicate that the main binding modes between DNA and the complexes should be groove binding and electrostatic interaction.  相似文献   

17.
Highly selective molecularly imprinted layer-coated silica nanoparticles for bisphenol A (BPA) were synthesized by molecular imprinting technique with a sol-gel process on the supporter of silica nanoparticles. The BPA-imprinted silica nanoparticles were characterized by fourier transform infrared spectrometer, transmission electron microscope, dynamic adsorption and static adsorption tests. The equilibrium association constant, Ka, and the apparent maximum number of binding sites, Qmax, were estimated to be 1.25 × 105 mL μmol−1 and 16.4 μmol g−1, respectively. The BPA-imprinted silica nanoparticles solid-phase extraction (SPE) column had higher selectivity for BPA than the commercial C18-SPE column. The results of the study indicated that the prepared BPA-imprinted silica nanoparticles exhibited high adsorption capacity and selectivity, and offered a fast kinetics for the rebinding of BPA. The BPA-imprinted silica nanoparticles were successfully used in SPE to selectively enrich and determine BPA from shampoo, bath lotion and cosmetic cream samples.  相似文献   

18.
Graphene is a good adsorbent for organic pollutants, especially for compounds containing benzene rings. When used in TiO2 nanotube arrays for micro-solid phase extraction (μ-SPE), the combination of graphene’s strong adsorptive properties with its good separation capabilities results in excellent sample preconcentration performance. In the present study, graphene-modified TiO2 nanotube arrays were prepared by electrodeposition using a cyclic voltammetric reduction method. Four carbamate pesticides, including metolcarb, carbaryl, isoprocarb, and diethofencarb, were used as model analytes to validate the enrichment properties of the prepared adsorbent in μ-SPE. Factors affecting the enrichment efficiency of the μ-SPE procedure were optimized and included sample pH, elution solvents, salting-out effect, adsorption time and desorption time. Under optimal conditions, graphene-modified TiO2 nanotube arrays exhibited excellent enrichment efficiency for carbamate pesticides. The detection limits of these carbamate pesticides ranged from 2.27 to 3.26 μg L−1. The proposed method was validated using four environmental water samples, and yields of pesticides recovered from spiked test samples of the four analytes were in the range of 83.9–108.8%. These results indicate that graphene-modified TiO2 nanotube arrays exhibit good adsorption to the target pollutants, and the method described in this work could be used as a faster and easier alternative procedure for routine analysis of carbamate pesticides in real water samples.  相似文献   

19.
Wang AJ  Xu JJ  Zhang Q  Chen HY 《Talanta》2006,69(1):210-215
Poly(dimethylsiloxane) (PDMS) microfluidic channels modified by citrate-stabilized gold nanoparticles after coating a layer of linear polyethylenimine (LPEI) were successfully used to separate dopamine and epinephrine, which were difficult to be separated from baseline in native and hybrid PDMS microchannels. In-channel amperometric detection with a single carbon fibre cylindrical electrode was employed. Experimental parameters of separation and detection processes were optimized in detail. The analytes were well separated within 100 s in a 3.7 cm long separation channel at a separation voltage of +800 V using a 30 mM phosphate buffer solution (PBS, pH 7.0). Linear responses of them were obtained both from 25 to 600 μM with detection limits of 2 μM for dopamine and 5 μM for epinephrine, respectively. The modified PDMS channels have a long-term stability and an excellent reproducibility within 2 weeks.  相似文献   

20.
A new polymeric coating consisting of a dual-phase, polydimethylsiloxane (PDMS) and polypyrrole (PPY) was developed for the stir bar sorptive extraction (SBSE) of antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) from plasma samples, followed by liquid chromatography analysis (SBSE/LC-UV). The extractions were based on both adsorption (PPY) and sorption (PDMS) mechanisms. SBSE variables, such as extraction time, temperature, pH of the matrix, and desorption time were optimized, in order to achieve suitable analytical sensitivity in a short time period. The PDMS/PPY coated stir bar showed high extraction efficiency (sensitivity and selectivity) toward the target analytes. The quantification limits (LOQ) of the SBSE/LC-UV method ranged from 20 ng mL−1 to 50 ng mL−1, and the linear range was from LOQ to 500 ng mL−1, with a determination coefficient higher than 0.99. The inter-day precision of the SBSE/LC-UV method presented a variation coefficient lower than 15%. The efficiency of the SBSE/LC-UV method was proved by analysis of plasma samples from elderly depressed patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号