首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
C(alpha)-Formylglycine, the catalytic amino acid residue in the active site of sulfatases, is generated by post-translational modification of a cysteine or serine residue. We describe a highly sensitive procedure for the detection of C(alpha)-formylglycine-containing peptides in tryptic digests of sulfatase proteins. The protocol is based on the formation of hydrazone derivatives of C(alpha)-formylglycine-containing peptides when using dinitrophenylhydrazine as a matrix for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). The hydrazone derivatives desorb and ionize with high efficiency and can be detected in the sub-femtomole range. The presence of C(alpha)-formylglycine is indicated by a mass increment of 180.13 u, corresponding to the hydrazone moiety, and also by a unique C-terminal fragment ion, characteristic of sulfatases, that becomes prominent in MALDI post-source decay mass spectra of the hydrazone derivatives.  相似文献   

2.
Post-translational modifications (PTMs) of proteins are essential for proper function, as they regulate many aspects of a protein's activity and interaction with substrates. When analyzing modified peptides derived from such proteins by mass spectrometry, these modifications can dissociate, producing either a marker ion or neutral loss characteristic of the modification, which have conventionally been monitored with a precursor ion scan or neutral loss scan, respectively. Although powerful, both precursor ion scans and neutral loss scans can only screen for one particular modification at a time. This has led to the development of multiple neutral loss monitoring (MNM) for neutral losses and multiple precursor ion monitoring (MPM) for marker ions on electrospray instruments. Here, we report their implementation on a matrix-assisted laser desorption/ionization (MALDI) instrument as well as the inception of a novel scan strategy termed targeted multiple precursor ion monitoring (tMPM). This latter scan strategy has been developed on a MALDI tandem time-of-flight (TOF/TOF) mass spectrometer for the identification of multiple PTMs via their associated marker ions by manipulating certain components of the instrument, notably the timed ion selector and the delayed extraction source 2. Targeted MPM combined with a second approach, multiple neutral loss monitoring (MNM), is shown to be a successful approach in the identification of PTMs, identifying multiple modified peptides in a complex sample matrix.  相似文献   

3.
We explored matrix-assisted laser desorption/ionization (MALDI) tandem time-of-flight (TOF/TOF) mass spectrometry for the analysis of N-glycosylated peptides, using horseradish peroxidase (HRP) as a test case. Two different types of cleavage were observed in the TOF/TOF fragmentation spectra: Firstly, cleavages of peptide bonds yielded fragments with the attached N-glycans staying intact, thus revealing information on peptide sequence and glycan attachment site. Secondly, fragmentation of the glycan moiety was characterized by cleavage of glycosidic bonds as well as a (0,2)X-ring fragmentation of the innermost N-acetylglucosamine of the chitobiose core. Loss of the complete N-glycan moiety occurred by cleavage of both the N-glycosidic bond and the side-chain amide group of the N-glycosylated asparagine, yielding a characteristic peak doublet with a mass difference of 17 Da, which revealed the individual masses of the N-glycan and the peptide moiety. Analysis of a HRP tryptic digest at the sub-picomole level allowed the characterization of various N-glycosylated peptides including those with internal disulfide linkages, a glycopeptide linked via a disulfide bond to another peptide, and a 5 kDa glycopeptide carrying two N-glycans. The potential of our approach was illustrated by the detection of the following novel features of HRP glycosylation: (i) The conjugation of a xylosylated trimannosyl N-glycan without core-fucosylation to site Asn316, showing for the first time unambiguously the occupation of this site; and (ii) A disaccharide N-acetylhexosamine1deoxyhexose1 attached to N-glycosylation sites Asn285 and Asn298, which might represent a Fuc(alpha1-3)GlcNAc- moiety arising from the processing of N-glycans by a horse-radish endoglycosidase during biosynthesis of HRP.  相似文献   

4.
A high-performance orthogonal time-of-flight (TOF) mass spectrometer was developed specifically for use in combination with a matrix-assisted laser desorption/ionization (MALDI) source. The MALDI source features an ionization region containing a buffer gas with variable pressure. The source is interfaced to the TOF section via a collisional focusing ion guide. The pressure in the source influences the rate of cooling and allows control of ion fragmentation. The instrument provides uniform resolution up to 18,000 FWHM (full width at half maximum). Mass accuracy routinely achieved with a single-point internal recalibration is below 2 ppm for protein digest samples. The instrument is also capable of recording spectra of samples containing compounds with a broad range of masses while using one set of experimental conditions and without compromising resolution or mass accuracy.  相似文献   

5.
In the matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS) analysis of various compounds synthesized in our laboratory, strong [M - H]+ ion peaks were often observed for the molecules with tertiary amino groups. In this work, the MALDI TOF MS behavior of two groups of compounds that incorporate tertiary amino moieties was investigated. One group is bisurea dimethylanilines (BUDMAs) prepared for the study of molecular recognition in thermoplastic elastomers, and the other group is the poly(propylene imine) diaminobutane dendrimers. The results clearly demonstrate the appearance of the [M - H]+ ions. In order to understand the possible mechanisms for the generation of these ions, a series of model compounds, ranging from primary to tertiary amines, were investigated. Unlike the tertiary amines, no [M - H]+ ion peaks were recorded for the primary amines, and only barely detectable ones, if any, for some secondary amines. It appears that the tertiary amino groups play an important role in the formation of these ions. In addition to MALDI TOF MS analysis, these samples were also applied to electrospray ionization (ESI) MS where no [M - H]+ ions were observed. The results indicate that the generation of [M - H]+ ion is due to the unique MALDI conditions and is likely to be formed via dehydrogenation of a protonated tertiary amine resulting in an N=C double bond. The absence of [M - H]+ ion peaks for the primary and secondary amines is probably because upon their formation these ions could easily transfer one proton to the corresponding amines in the MALDI gas-phase plume, yielding neutral imines that cannot be detected by MS.  相似文献   

6.
Electrospray mass spectrometry (ES/MS) and matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI/TOF/MS) were used to provide mass spectra from seven elapid snake venoms. Spectral interpretation was much simpler for MALDI/TOF/MS. ES/MS proved more useful for the provision of molecular weight data for very closely related peptides, but suppression of higher molecular weight compounds was seen to occur during flow injection analysis. MALDI/TOF/MS proved useful for providing a complete picture of the venom, but the low resolution led to obscuring of major ions, and the mass accuracy was poorer for known peptides. Suppression also occurred during MALDI/TOF/MS but could be overcome using alternative matrices because the spectra were very dependent on the choice of matrix. ES/MS and MALDI/TOF/MS provide complementary and confirmatory information such that for the anal sis of complex peptide mixtures (snake venoms), the use of both techniques is desirable.  相似文献   

7.
Simple, rapid and inexpensive one-step reverse micellar microextraction (RMME) procedures were combined with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) for the determination of thiol-containing peptides and amino acids. In this investigation, a thiol-containing peptide (HW6) was chosen as model compound to understand the mechanism of RMME. The electrostatic interactions between the thiol-containing peptide and reverse micelles were proposed to be reason for the transfer of analytes from the aqueous phase to the organic phase. Reverse micelles were formed by the cationic surfactant, methyltrioctylammonium chloride (MTOAC). The best extraction efficiency of HW6 was obtained under the following conditions: pH 11.0, ionic strength 5.0 mM of KCl and micelle concentration 7.0 mM of MTOAC. The limits of detection (LODs) obtained for HW6 in water, urine and plasma samples were 0.15, 0.19 and 0.28 microM, respectively, with relative standard deviation (RSD) values in the range +/-8.8-10.5%. The sensitivity obtained in water by the present method was 45-fold higher than that of the conventional use of atmospheric-pressure (AP)-MALDI MS. Furthermore, the applicability of the proposed approach was extended for the determination of thiol-containing amino acids in sample solutions by using MALDI time-of-flight (TOF) MS.  相似文献   

8.
The use of matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) for the quantitative determination of phospholipid (PL) molecular species has been problematic, due primarily to the formation of multiple signals (corresponding to the molecular ion and other adducts) for some classes of PL. For example, analysis of phosphatidylcholine (PC) yielded signals that corresponded to protonated and sodiated molecules in the MALDI spectrum. The resulting spectral overlap among various molecular species (e.g. [PC(16:0/18:2) + Na] and [PC(18:2/18:3)]) made it impossible to ascertain their relative amounts using this technique. Other spectral ambiguities existed among different structural isomers, such as PC(18:1/18:1) and PC(18:0/18:2). We determined that molecular species could be resolved by MALDI-TOFMS by first removing the polar head (e.g. phosphocholine) from the phospholipid to effect production of only the sodiated molecules of the corresponding diacylglycerols (DAGs). Analysis of the resulting spectrum allowed unequivocal determination of the molecular species profile of PC from potato tuber and soybean. Estimation of fatty acid composition based on the molecular species determined by MALDI-TOFMS analysis agreed with that from GC-FID analysis. Post-source decay (PSD) was used to resolve standard isomers of PC (e.g. 18:1/18:1 vs. 18:0/18:2). Our results indicated that PSD is a useful approach for resolving structural isomers of PL molecular species.  相似文献   

9.
Oxidative damage to proteins can occur under physiological conditions through the action of reactive oxygen species, including those containing nitrogen such as peroxynitrite (ONO2-). Peroxynitrite has been shown in vitro to target tyrosine residues in proteins through free radical addition to produce 3-nitrotyrosine. In this work, we show that mass spectral patterns associated with 3-nitrotyrosine containing peptides allow identification of peptides containing this modification. Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry was used to characterize a synthetic peptide AAFGY(m-NO2)AR and several peptides containing 3-nitrotyrosine derived from bovine serum albumin treated with tetranitromethane. A unique series of ions were found for these peptides in addition to the mass shift of +45 Da corresponding to the addition of the nitro group. Specifically, two additional ions were observed at roughly equal abundance that correspond to the loss of one and two oxygens, and at lower abundances, two ions are seen that suggest the formation of hydroxylamine and amine derivatives. These latter four components appear to originate by laser-induced photochemical decomposition. MALDI-MS analysis of the synthetic peptide containing 3-nitrotyrosine revealed this same pattern. Post-source decay (PSD) MALDI-time-of-flight (TOF) and collisional activation using a prototype MALDI quadrupole TOF yielded extensive fragmentation that allowed site-specific identification of 3-nitrotyrosine. Conversion of peptides containing 3-nitrotyrosine to 3-aminotyrosine with Na2S2O4 yielded a single molecular ion by MALDI with an abundant sidechain loss under PSD conditions. These observations suggest that MALDI can provide a selective method for the analysis and characterization of 3-nitrotyrosine-containing peptides.  相似文献   

10.
Six anthraquinone derivatives were analyzed using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS). Clear (pseudo) molecular ions were observed for all the compounds. Interestingly, for some derivatives, strong ions with double cation adduction were also recorded in the positive mode. It is remarkable that all these ions are singly charged. In this work, possible mechanisms for the double cation adduction were investigated and discussed. It appears that the double cation adduction was due to the electron deficient nature of the derivatives, and formed by taking up two singly charged cations and one electron. Substituents on the anthraquinone ring were found to have a significant effect on the double cation adduction. In contrast, no considerable influence of the acidity of MALDI matrix/solution was observed, even on the double proton adduction. Furthermore, it was demonstrated that double cation adduction might occur in the MALDI gas-phase plume. In addition to the anthraquinones, three more electron deficient compounds of different types, i.e. a perylene bisimide derivative (PB), 3,7-decanoylamino-4,8-dihydrobenzo[1,2-b:4,5-b']dithiophene-4,8-dione (TQ) and 6,6-phenyl C61-butyric acid methyl ester (PCBM), were also analyzed with MALDI TOF MS. The results indicate that the 'abnormal' double cation adduction might be a 'normal' phenomenon in the MALDI TOF MS analysis of many electron deficient compounds.  相似文献   

11.
Metastable decomposition of ions generated in matrix-assisted laser desorption/ionization (MALDI) mass spectrometers complicates analysis of biological samples that have labile bonds. Recently, several academic laboratories and manufacturers of commercial instruments have designed instruments that introduce a cooling gas into the ion source during the MALDI event and have shown that the resulting vibrational cooling stabilizes these labile bonds. In this study, we compared stabilization and detection of desorbed gangliosides on a commercial orthogonal time-of-flight (oTOF) instrument with results we reported previously that had been obtained on a home-built Fourier transform mass spectrometer. Decoupling of the desorption/ionization from the detection steps resulted in an opportunity for desorbing thin-layer chromatography (TLC)-separated gangliosides directly from a TLC plate without compromising mass spectral accuracy and resolution of the ganglioside analysis, thus coupling TLC and oTOF mass spectrometry. The application of a declustering potential allowed control of the matrix cluster and matrix adduct formation, and, thus, enhanced the detection of the gangliosides.  相似文献   

12.
We report the development of a solid‐phase proteolytic digestion and continuous deposition microfluidic chip platform for low volume fraction collection and off‐line matrix‐assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) mass spectrometry. Tryptic peptides were formed in an on‐chip bioreactor and continuously deposited onto a MALDI target plate using a motor‐driven xyz stage. The bioreactor consisted of a 4 cm × 200 µm × 50 µm microfluidic channel with covalently immobilized trypsin on an array of 50 µm diameter micropost structures with a 50 µm edge‐to‐edge inter‐post spacing. A 50 µm i.d. capillary tube was directly attached to the end of the bioreactor for continuous sample deposition. The MALDI target plate was modified by spin‐coating a nitrocellulose solution containing a MALDI matrix on the surface prior to effluent deposition. Protein molecular weight standards were used for evaluating the performance of the digestion and continuous deposition system. Serpentine sample traces 200 µm wide were obtained with a 30 fmol/mm quantity deposition rate and a 3.3 nL/mm volumetric deposition rate. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
We describe a new interface for a prototype quadrupole-quadrupole-time-of-flight (TOF) mass spectrometer (Centaur, Sciex) that allows rapid switching between electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) modes of operation. Instrument performance in both modes is comparable (i.e., resolution approximately 10,000 FWHM, mass accuracy <10 ppm, sensitivity approximately 1 fmol) because the ion source is decoupled from the TOF mass analyzer by extensive gas collisions in the quadrupole stages of the instrument. The capacity to obtain side-by-side high quality ESI and MALDI mass spectra from a single proteolytic mixture greatly facilitates the identification of proteins and elucidation of their primary structures. Improved strategies for protein identification result from this ability to measure spectra using both ionization modes in the same instrument and to perform MS/MS on singly charged as well as multiply charged ions. Examples are provided to demonstrate the utility and performance of the modified instrument.  相似文献   

14.
The extent of N-glycosylation of yeast external invertase at each of the 14 potential sites was determined by the combination of proteolytic digestions and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF-MS). The average molecular mass of the intact external invertase was determined as 97 kDa by MALDI/TOF-MS. The intact protein was digested with trypsin, Lys-C and Asp-N, followed by high-performance liquid chromatographic separation. The proteolytic digests were analyzed by MALDI/MS screening for the glycopeptides. The glycopeptides were then treated with peptide:N-glycosidase F (PNGase F) and/or endo-beta-N-acetylglucosaminidase (Endo H) and the molecular mass of the deglycosylated peptide was determined by MALDI/MS and matched with the peptide predicted by a computer program. The sequences of some peptides or deglycosylated peptides were identified by the MALDI post-source decay technique. The size of the oligosaccharide, the degree of glycosylation and the distribution of the oligosaccharides at each individual potential glycosylation site were characterized. This information goes for beyond previously published data and sometimes differs from them. During this study, the amino acid sequence originally derived from the DNA sequence of the gene coding for invertase was also verified and it was found that this protein when expressed from SUC2 gene might be created as more than one sequence which differ by a few amino acid substitutions (Asn58<-->Thr, Asn65-->His and Val412<-->Ala).  相似文献   

15.
We report the application of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) for the accurate measurement of mass of low molecular weight compounds (smaller than 1500 Da), a linear peptide, two types of cyclic depsipeptides, a polyhydroxy-macrocyclic lactone, and two prenylated flavonoids, with delayed extraction in the reflector mode. The performance of the MALDI-TOF instrument was less than those of fast atom bombardment and Fourier-transform ion cyclotron resonance mass spectrometry instruments and insufficient to give acceptable accuracy for literature reporting. Nevertheless, when combined with NMR spectrometry and/or amino acid analysis to give information on the numbers of carbon atoms and index of hydrogen deficiency, MALDI was useful for determination of the elemental composition of the low molecular weight compounds available in small quantities.  相似文献   

16.
A prototype matrix-assisted laser desorption/ionization quadrupole time-of-flight (MALDI-TOF) tandem mass spectrometer was used to sequence a series of phosphotyrosine-, phosphothreonine- and phosphoserine-containing peptides. The high mass resolution and mass accuracy of the instrument allowed the localization of one, three or four phosphorylated amino acid residues in phosphopeptides up to 3.1 kDa. Tandem mass spectra of two different phosphotyrosine peptides permitted amino acid sequence determination and localization of one and three phosphorylation sites, respectively. The phosphotyrosine immonium ion at m/z 216.04 was observed in these MALDI low-energy CID tandem mass spectra. Elimination of phosphate groups was evident from the triphosphorylated peptide but not from the monophosphorylated species. The main fragmentation pathway for the synthetic phosphothreonine-containing peptide and for phosphoserine-containing peptides derived from beta-casein and ovalbumin was the beta-elimination of phosphoric acid with concomitant conversion of phosphoserine to dehydroalanine and phosphothreonine to 2-aminodehydrobutyric acid. Peptide fragment ions of the b- and y-type allowed, in all cases, the localization of phosphorylation sites. Ion signals corresponding to (b-17), (b-18) and (y-17) fragment ions were also observed. The abundant neutral loss of phosphoric acid (-98 Da) is useful for femtomole level detection of phosphoserine-peptides in crude peptide mixtures generated by gel in situ digestion of phosphoproteins.  相似文献   

17.
A novel method for peptide sequencing by matrix-assisted laser desorption/ionization mass spectrometry with a time-of-flight/time-of-flight analyzer (MALDI-TOF/TOF) is presented. A stable isotope label introduced in the peptide N-terminus by derivatization, using a 1:1 mixture of acetic anhydride and deuterated acetic anhydride, allows for easy and unambiguous identification of ions belonging either to the N- or the C-terminal ion series in the product ion spectrum, making sequence assignment significantly simplified. The good performance of this technique was shown by successful sequencing of the contents of several peptide maps. A similar approach was recently applied to nanoelectrospray ionization (nanoESI) and nano-liquid chromatography/tandem mass spectrometry (LC/MS/MS). The MALDI-TOF/TOF technique allows for fast, direct sequencing of modified peptides in proteomics samples, and is complementary to the nanoESI and nanoLC/MS/MS approaches.  相似文献   

18.
Derivatization of tryptic peptides using an Ettan CAF matrix-assisted laser desorption/ionization (MALDI) sequencing kit in combination with MALDI-post source decay (PSD) is a fast, accurate and convenient way to obtain de novo or confirmative peptide sequencing data. CAF (chemically assisted fragmentation) is based on solid-phase derivatization using a new class of water stable sulfonation agents, which strongly improves PSD analysis and simplifies the interpretation of acquired spectra. The derivatization is performed on solid supports, ZipTip(microC18, limiting the maximum peptide amount to 5 microg. By performing the derivatization in solution enabled the labeling of tryptic peptides derived from 100 microg of protein. To increase the number of peptides that could be sequenced, derivatized peptides were purified using multidimensional liquid chromatography (MDLC) prior to MALDI sequencing. Following the first dimension strong cation exchange (SCX) chromatography step, modified peptides were separated using reversed-phase chromatography (RPC). During the SCX clean up step, positively charged peptides are retained on the column while properly CAF-derivatized peptides (uncharged) are not. A moderately complex tryptic digest, prepared from six different proteins of equimolar amounts, was CAF-derivatized and purified by MDLC. Fractions from the second dimension nano RPC step were automatically sampled and on-line dispensed to MALDI sample plates and analyzed using MALDI mass spectrometry fragmentation techniques. All proteins in the derivatized protein mixture digest were readily identified using MALDI-PSD or MALDI tandem mass spectrometry (MS/MS). More than 40 peptides were unambiguously sequenced, representing a seven-fold increase in the number of sequenced peptides in comparison to when the CAF-derivatized protein mix digest was analyzed directly (no MDLC-separation) using MALDI-PSD. In conclusion, MDLC purification of CAF-derivatized peptides significantly increases the success rate for de novo and confirmative sequencing using various MALDI fragmentation techniques. This new approach is not only applicable to single protein digests but also to more complex digests and could, thus, be an alternative to electrospray ionization MS/MS for peptide sequencing.  相似文献   

19.
Mass spectrometry using a matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) instrument is a widespread technique for various types of proteomic analysis. Along with an expanding interest in proteomics, there is a strong requirement for the identification of proteins with high confidence from biological samples. Peptide modification by a wide variety of post-translational modifications (PTMs), the existence of different protein isoforms and the presence of uncharacterized genomes of many species, make protein identification through peptide mass fingerprinting (PMF) often unachievable. Peptide de novo sequencing has been proven to be a useful approach to overcome these variables, and efficient derivatization processes are important tools to achieve this goal. In the present work we describe the methodology and experimental applications of a fast, efficient and cheap lysine derivatization. This chemical modification improves the signals from lysine-terminated peptides and can be efficiently used as a lysine-blocking agent in combination with other derivatization techniques. Most importantly, upon peptide fragmentation it generates a neat series of predominantly y-ions, allowing the determination of unambiguous amino acid sequences. Moreover, this chemical compound was used with target-eluted samples, enabling a second, alternative analysis of the same sample in the MALDI mass spectrometer.  相似文献   

20.
Some experimental factors affecting the resolution in glycerol infrared matrix-assisted laser desorption/ionization (IR-MALDI) time-of-flight (TOF) mass spectrometry were investigated. Loading the sample inside a cavity covered with a grid was found to improve the resolving power as reported previously, although not to the extent attainable in UV-MALDI using the same instrument. The resolving power improved as the laser spot area at the sample position got larger, becoming almost comparable with that in UV-MALDI when the spot area was a little larger than the cavity size. Reduced concentration of the ablated materials in the acceleration region with the use of the grid and large irradiation area may be responsible for the enhanced resolution. In addition, the threshold laser fluences measured in this work were lower than those reported in the literature and tended to decrease more rapidly as the irradiation area increased than predicted previously. The implication of similar threshold fluences for matrix and analyte ions is discussed in relation to the analyte ion formation mechanism.  相似文献   