首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 604 毫秒
1.
A ultra‐fast liquid chromatography method applied to quantitation of doripenem in powder for injection was validated. Validation parameters were assayed and a rapid analysis was established by a reversed‐phase system comprising a C18 column endcapped (50 × 4.0 mm, 2.0 μm), mobile phase consisting of phosphoric acid 0.01% (pH 3.8) and acetonitrile (98:02, v /v) and a flow rate of 0.4 mL min−1. Drug stability was studied through submission to forced conditions, allowing the major degradation products to be detected and the kinetics parameters to be established. Thermal and oxidative degradation were determined, and indicated a kinetic decomposition following first and second order, respectively. The main degradation products were identified by LC–MS analysis, and the results were evaluated in order to suggest the chemical structures corresponding to respective masses and fragmentations. Six compounds were identified, with m/z 411, 427, 437, 634, 650 and 664. All of them resulted from cleavage of β ‐lactam ring and alcoholic chain and/or dimerization. These experimental results provide valuable information about the stability of doripenem reconstituted solution and procedures for its handling and storage.  相似文献   

2.
The stability-indicating LC assay method was developed and validated for quantitative determination of cefoselis sulphate in the presence of degradation products formed during the forced degradation studies. An isocratic, RP-HPLC method was developed with C-18 (250 × 4.6 mm, 5 μm) column and 12 mM ammonium acetate-acetonitrile (95:5 V/V) as a mobile phase. The flow rate of the mobile phase was 1.0 mL min−1. Detection wavelength was 260 nm and temperature was 30°C. Cefoselis similarly to other cephalosporins was subjected to stress conditions of degradation in aqueous solutions including hydrolysis, oxidation, photolysis and thermal degradation. The developed method was validated with regard to linearity, accuracy, precision, selectivity and robustness. The method was applied successfully for identification and determination of cefoselis sulphate in pharmaceuticals and during kinetic studies.  相似文献   

3.
Photocatalytic degradation of propiconazole, a triazole pesticide, in the presence of titanium dioxide (TiO2) under ultraviolet (UV) illumination was performed in a batch type photocatalytic reactor. A full factorial experimental design technique was used to study the main effects and the interaction effects between operational parameters in the photocatalytic degradation of propiconazole in a batch photo-reactor using the TiO2 aqueous suspension. The effects of catalyst concentration (0.15–0.4 gL?1), initial pH (3–9), initial concentration (5–35 mg L?1) and light conditions were optimised at a reaction time duration of 90 min by keeping area/volume ratio constant at 0.919 cm2 mL?1. Photocatalytic oxidation of propiconazole showed 85% degradation and 76.57% mineralisation under UV light (365 nm/30 Wm?2) at pH 6.5, initial concentration 25 mg L?1 and constant temperature (25 ± 1 °C). The Langmuir–Hinshelwood kinetic model has successfully elucidated the effects of the initial concentration on the degradation of propiconazole and the data obtained are consistent with the available kinetic parameters. The photocatalytic transformation products of propiconazole were identified by using gas chromatography–mass spectrometry (GC/MS). The pathway of degradation obtained from mass spectral analysis shows the breakdown of transformation products into smaller hydrocarbons (m/z 28 and 39).  相似文献   

4.
Alkaline hydrolysis (pH 10.5) of the three 7-(oxyiminoacyl)cephalosporins 1a–c (cefuroxime, ceftazidime, and ceftriaxone) was studied at 37° using HPLC and 1H-NMR techniques. The 7-epicephalosporin 2 , the 3-methylidene compound 3 , and the 6-epimer 4 of the 3-methylidene compound 3 were identified for each cephalosporin as the major degradation products under the conditions used; ceftazidime ( 1b ) yielded also the Δ2-isomer 5b (Scheme 1). A kinetic scheme was developed to account for the production of these compounds, and the different kinetic constants involved in the process were calculated. The experimental results show that the presence of a pyridinio group at position C–C(3) favours the appearance of the Δ2-isomer, which was detected mainly in cephalosporins bearing an ester function at C(4). The presence of an oxyimino group at C? CONH? C(7) facilitates epimerization at C(7) (→ 2 ), whereas that of an electron-withdrawing group at C? C(3) results in a increased formation constant for the 3-methylidene compound 3 . The 3-methylidene compounds 3a–c produced by the three cephalosporins on cleavage of the β-lactam ring all underwent epimerization at C(6) to yield the corresponding 6-epimer 4 .  相似文献   

5.
In this work, a kinetic study on the thermal degradation of carbon fibre reinforced epoxy is presented. The degradation is investigated by means of dynamic thermogravimetric analysis (TG) in air and inert atmosphere at heating rates from 0.5 to 20°C min−1 . Curves obtained by TG in air are quite different from those obtained in nitrogen. A three-step loss is observed during dynamic TG in air while mass loss proceeded as a two step process in nitrogen at fast heating rate. To elucidate this difference, a kinetic analysis is carried on. A kinetic model described by the Kissinger method or by the Ozawa method gives the kinetic parameters of the composite decomposition. Apparent activation energy calculated by Kissinger method in oxidative atmosphere for each step is between 40–50 kJ mol−1 upper than E a calculated in inert atmosphere. The thermo-oxidative degradation illustrated by Ozawa method shows a stable apparent activation energy (E a ≈130 kJ mol−1 ) even though the thermal degradation in nitrogen flow presents a maximum E a for 15% mass loss (E a ≈60 kJ mol−1 ). This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

6.
Infrared (IR) spectroscopy was adopted to study the hydrolytic degradation of films of aliphatic polyesters in alkaline environment. A measurable increase with the time of immersion of the absorbance of the peak centered at about 1570 cm−1 was observed. Analysis of the IR spectra showed that the integrated peak area in that region can be used to quantify changes in the concentration of degradation products and thus to provide indications regarding the kinetic constant of the hydrolysis reaction. It was found that the hydrolysis of ester bonds proceeds linearly with time, and this result suggests that the controlling mechanism is the chemical reaction rather than water diffusion. The results also show that degradation rate increases with increasing polydispersity.  相似文献   

7.
A stability-indicating reversed-phase liquid chromatographic (RPLC) method has been established for analysis of ramipril (RAM) and moexipril hydrochloride (MOEX.HCl) in the presence of the degradation products generated in studies of forced decomposition. The drug substances were subjected to stress by hydrolysis (0.1 m NaOH and 0.1 m HCl), oxidation (30% H2O2), photolysis (254 nm), and thermal treatment (80 °C). The drugs were degraded under basic and acidic conditions and by thermal treatment but were stable under other stress conditions investigated. Successful separation of the drugs from the degradation products was achieved on a cyanopropyl column with 40:60 (v/v) aqueous 0.01 m ammonium acetate buffer (pH 6)–methanol as mobile phase at a flow rate of 1 mL min−1. Detection was by UV absorption at 210 nm. Response was a linear function of concentration over the range 5–50 μg mL−1 (r > 0.9995), with limits of detection and quantitation (LOD and LOQ) of 0.04 and 0.09 μg mL−1, respectively, for RAM and 0.014 and 0.32 μg mL−1, respectively, for moexipril. The method was validated for specificity, selectivity, solution stability, accuracy, and precision. Statistical analysis proved the method enabled reproducible and selective quantification of RAM and MOEX as the bulk drug and in pharmaceutical preparations. Because the method effectively separates the drugs from their degradation products, it can be used as stability-indicating.  相似文献   

8.
A sensitive, selective, precise and stability-indicating high-performance thin-layer chromatographic method of analysis of lamivudine both as a bulk drug and in formulations was developed and validated. The solvent system consisted of carbon tetrachloride – methanol – chloroform - acetonitrile (7.0: 3.0: 2.0: 1.5, v/v/v/v). Densitometric analysis of lamivudine was carried out in the absorbance mode at 275 nm. This system was found to give compact spots for lamivudine (RF value of 0.36 ± 0.02) following double development of chromatoplates with the same mobile phase. Lamivudine was subjected to acid and alkali hydrolysis, oxidation, dry heat and wet heat treatment and photo degradation. The drug undergoes degradation under acidic, basic conditions, oxidation, wet heat and photo degradation. Also the degraded products were well resolved from the pure drug with significantly different RF values. Linearity was found to be in the range of 50 – 1000 ng spot–1 with significantly high value of correlation coefficient. The linear regression analysis data for the calibration plots showed good linear relationship with r2 = 0.9994 ± 0.05 in the working concentration range of 300 ng spot–1 to 1000 ng spot–1. The mean value of slope and intercept were 0.11 ± 0.08 and 10.47 ± 1.21, respectively. The method was validated for precision, robustness and recovery. The limit of detection and quantitation were 15 ng spot–1 and 40 ng spot–1 respectively. As the method could effectively separate the drug from its degradation products, it can be employed as a stability indicating one. Moreover, the proposed HPTLC method was utilized to investigate the kinetics of acid degradation process. Arrhenius plot was constructed and activation energy was calculated.  相似文献   

9.

A simple and rapid development of a stability-indicating LC method for determination of chloroquine diphosphate in the presence of its hydrolysis, oxidative and photolysis degradation products is described. Stress testing showed that chloroquine diphosphate was degraded under basic conditions and by photolytic treatment but was stable under the other stress conditions investigated. Separation of the drug from its degradation products was achieved with a Nova Pack C18 column, 0.01 M PIC B7 and acetonitrile (40:60 v/v) pH 3.6, as mobile phase. Response was linear over the range 0.08–5.70 μg mL−1 (= 0.996), with limits of detection and quantification (LOD and LOQ) of 0.17 and 0.35 μg mL−1, respectively.

  相似文献   

10.
The ternary complex kinetic model for metallomicellar catalysis was employed to investigate the effect of Zn2+ ion or Ni2+ion complexes of long alkyl-pyridines with hydroxyl groups in micellar solution on the hydrolysis of p-nitrophenyl picolinate in this paper. The kinetic and the thermodynamic parameters (K N, K r, K M) were obtained. More worthily, the effect of pH on the hydrolysis of p-nitrophenyl picolinate in metallomicellar phase was discussed quantitatively. The rate constant (K N) of the hydrolysis of p-nitrophenyl picolinate in metallomicellar phase was obtained and compared with Cu2+ ion complex system. The results indicated that Cu2+ ion micelle, Ni2+ ion micelle and Zn2+ ion micelle all exhibited great catalytic effects on the hydrolysis of p-nitrophenyl picolinate. and the order of activity is:Cu2+ ion micelle ≥ Ni2+ ion micelle ≥ Zn2+ ion micell. Moreover, the reasonability of the ternary complex kinetic model was verified further.  相似文献   

11.
The chemical warfare agent O-ethyl S-(2-diisopropylaminoethyl) methyl phosphonothiolate (VX) and many related degradation products produce poorly diagnostic electron ionization (EI) mass spectra by transmission quadrupole mass spectrometry. Thus, chemical ionization (CI) is often used for these analytes. In this work, pseudomolecular ([M+H]+) ion formation from self-chemical ionization (self-CI) was examined for four VX degradation products containing the diisopropylamine functional group. A person-portable toroidal ion trap mass spectrometer with a gas chromatographic inlet was used with EI, and both fixed-duration and feedback-controlled ionization time. With feedback-controlled ionization, ion cooling (reaction) times and ion formation target values were varied. Evidence for protonation of analytes was observed under all conditions, except for the largest analyte, bis(diisopropylaminoethyl)disulfide which yielded [M+H]+ ions only with increased fixed ionization or ion cooling times. Analysis of triethylamine-d15 provided evidence that [M+H]+ production was likely due to self-CI. Analysis of a degraded VX sample where lengthened ion storage and feedback-controlled ionization time were used resulted in detection of [M+H]+ ions for VX and several relevant degradation products. Dimer ions were also observed for two phosphonate compounds detected in this sample.  相似文献   

12.
Translational diffusion of poly-2,5-(1,3-phenylene)-1,3,4-oxadiazole (PMOD) in solution in 96% sulphuric acid was studied, and intrinsic viscosity was measured at different stages of thermal degradation. Polymer solution has previously been subjected to heating at temperature ranging from 75 to 104°C and then investigated at 26°C. A monotonic decrease in intrinsic viscosity and the molecular mass, M, of degraded products with increasing degradation temperature was detected. The rate constant of the degradation process has been obtained from the change in M of the degradation products with time at a fixed solution temperature, and the activation energy of the process was calculated by using the temperature dependence of the rate constant. The activation energy (E =102±8 kJ–1 ) is close to that obtained previously for the hydrolysis of poly-2,5-(1,4-phenylene)-1,3,4-oxadiazole (PPOD) in sulphuric acid (106 kJ–1 ), the rate constant being approximately twice in the value. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

13.
A kinetic study on the alkaline hydrolysis of cephaloridine ( 1 ) at pH 10.5 and 37° was carried out using ion-pair reversed-phase HPLC. The main resulting degradation products, the 7-epimer 2 of 1 , the Δ2-isomer 3 of 1 , and the 3-methylidene compound 4 were identified. The presence of a pyridinio group at C(31) results in a slightly increased formation constant for the 3-methylidene compound 4 and the 7-epimer 2, and introduces a new reaction: the isomerization of the double bond at C(3) in the dihydrothiazine ring to C(2).  相似文献   

14.
Gemifloxacin mesylate (GFM), chemically (R,S)‐7‐[(4Z)‐3‐(aminomethyl)‐4‐(methoxyimino)‐1‐pyrrolidinyl]‐1‐cyclopropyl‐6‐fluoro‐1,4‐dihydro‐4‐oxo‐1,8‐naphthyridine‐3‐carboxylic acid methanesulfonate, is a synthetic broad‐spectrum antibacterial agent. Although many papers have been published in the literature describing the stability of fluorquinolones, little is known about the degradation products of GFM. Forced degradation studies of GFM were performed using radiation (UV‐A), acid (1 mol L?1 HCl) and alkaline conditions (0.2 mol L?1 NaOH). The main degradation product, formed under alkaline conditions, was isolated using semi‐preparative LC and structurally elucidated by nuclear magnetic resonance (proton – 1H; carbon – 13C; correlate spectroscopy – COSY; heteronuclear single quantum coherence – HSQC; heteronuclear multiple‐bond correlation – HMBC; spectroscopy – infrared, atomic emission and mass spectrometry techniques). The degradation product isolated was characterized as sodium 7‐amino‐1‐pyrrolidinyl‐1‐cyclopropyl‐6‐fluoro‐1,4‐dihydro‐4‐oxo‐1,8‐naphthyridine‐3‐carboxylate, which was formed by loss of the 3‐(aminomethyl)‐4‐(methoxyimino)‐1‐pyrrolidinyl ring and formation of the sodium carboxylate. The structural characterization of the degradation product was very important to understand the degradation mechanism of the GFM under alkaline conditions. In addition, the results highlight the importance of appropriate protection against hydrolysis and UV radiation during the drug‐development process, storage, handling and quality control. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
Abstract

Three acetanilide herbicides—propanil, propachlor and pronamide—were studied for alkaline degradation using the HPLC technique and found to be relatively stable for chemical degradation with the highest hydrolysis rate for pronamide (k b = 0.4966 M?1 hr?1), followed by propachlor (kb = 0.1466 M?1 hr?1) and propanil kb = 0.0154 M?1 hr?1). Simultaneously, the Ames mutagenicity test for non-degraded and half-degraded acetanilides have been performed. Testing two types of samples (primary chemicals and mixtures of half-degraded primary chemicals with their degradation products, both in 10%-acetonitrile buffer; the ranges of concentrations were 2–400 mg l?1 for propanil and propachlor and 2–50 mg l?1 (for pronamide) have shown the increase in mutagenicity for propanil, the decrease for propachlor and almost the same dose-response curve for pronamide during their degradation. The preliminary results of the research indicate that some environmental problems related to the impact of pesticide degradation products can appear, not only to a pesticide itself.  相似文献   

16.
The stability-indicating LC assay method was developed and validated for quantitative determination of cefcapene pivoxil in the presence of degradation products formed during forced degradation studies. An isocratic RP-HPLC method was developed with a Lichrospher RP-18 (250 mm × 4.6 mm, 5 μm) column and the mobile phase composed of 45 volumes of acetonitrile and 55 volumes of mixture composed of citric acid 10 mmol L?1 and potassium chloride 18 mmol L?1. The flow rate of the mobile phase was 1 mL min?1. Detection wavelength was 270 nm and temperature was 30 °C. Cefcapene pivoxil, similar to other cephalosporins, was subjected to stress conditions of degradation in aqueous solutions including hydrolysis, oxidation, and thermal degradation. The method was validated with regard to linearity, accuracy, precision, selectivity, and robustness. The method was applied successfully for the determination of cefcapene pivoxil during kinetic studies in aqueous solutions (pH and thermal degradation) and in solid state (oxidative, thermal, and radiolytic degradation).  相似文献   

17.
Enzymatic hydrolysis of high-solid biomass (>10% w/w dry mass) has become increasingly important as a key step in the production of second-generation bioethanol. To this end, development of quantitative real-time assays is desirable both for empirical optimization and for detailed kinetic analysis. In the current work, we have investigated the application of isothermal calorimetry to study the kinetics of enzymatic hydrolysis of two substrates (pretreated corn stover and Avicel) at high-solid contents (up to 29% w/w). It was found that the calorimetric heat flow provided a true measure of the hydrolysis rate with a detection limit of about 500 pmol glucose s−1. Hence, calorimetry is shown to be a highly sensitive real-time method, applicable for high solids, and independent on the complexity of the substrate. Dose–response experiments with a typical cellulase cocktail enabled a multidimensional analysis of the interrelationships of enzyme load and the rate, time, and extent of the reaction. The results suggest that the hydrolysis rate of pretreated corn stover is limited initially by available attack points on the substrate surface (<10% conversion) but becomes proportional to enzyme dosage (excess of attack points) at later stages (>10% conversion). This kinetic profile is interpreted as an increase in polymer end concentration (substrate for CBH) as the hydrolysis progresses, probably due to EG activity in the enzyme cocktail. Finally, irreversible enzyme inactivation did not appear to be the source of reduced hydrolysis rate over time.  相似文献   

18.
Three novel Schiff base cobalt(Ⅱ) complexes containing benzoaza-15-crown-5, CoL^1, CoL^2 and CoL^3 were synthesized and characterized, and these complexes were used in catalytic hydrolysis of carboxylic ester (PNPP, p-nitrophenyl picolinate) as mimic hydrolytic metalloenzyme. The analysis of specific absorption spectra of the hydrolytic reaction systems indicated that the catalytic hydrolysis involved the key intermediates formed by PNPP with cobalt(Ⅱ) complexes. The CoL^3 bearing the electron withdrawing group shows better catalytic activity due to its stabilization effect on active species MLS^-. The catalytic mechanism of PNPP hydrolysis was also proposed. The kinetic parameter of PNPP catalytic hydrolysis has been calculated and the activation energy for the catalytic hydrolysis is 43.69, 39.76 and 35.44 kJ·mol^-1, respectively.  相似文献   

19.
The mechanism of hydrolysis of flurazepam (Dalmane) and six of its metabolites was investigated in mildly acidic solution (pH 0–2) by differential pulse polarography. Simultaneous determinations of the “parent” compound(s) and hydrolytic degradation product(s) are possible because of the different reduction potentials. The kinetic results can be explained if the hydrolytic reaction is considered reversible; this is important for evaluation of the hydrolysis and absorption of 5-(o-fluorophenyl)-1,4-benzodiazepines in the stomach. The rate constants and the pKa values corresponding to protonation of the azomethine groups are shown to be correlated. Appropriate kinetic data for other 1,4-benzodiazepines make it possible to evaluate the effects of certain substituents on the rate of hydrolysis and on the peak potentials of the “parent” compounds and their hydrolytic degradation products. The results of the kinetic investigations can be used for the identification of an isolated 5-(o-fluorophenyl)-1,4-benzodiazepine or identification of any 1,4-benzodiazepine studied here which exhibits some degree of acid hydrolysis within 24 h.  相似文献   

20.
Sulfur mustard (HD), bis(2-chloroethyl)sulfide, is one of a class of mustard agents which are chemical warfare agents. The main chemical warfare hydrolysis degradation products of sulfur mustards are: thiodiglycol, bis(2-hydroxyethylthio)methane, 1,2-bis(2-hydroxyethylthio)ethane, 1,3-bis(2-hydroxyethylthio)propane, and 1,4-bis(2-hydroxyethylthio)butane. The aim of this study is to identify these five hydrolysis degradation products utilizing reversed-phase high-performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (ICP-MS) for element-specific sulfur detection using a collision/reaction cell and electrospray ionization mass spectrometry to confirm the identification. To date, this is the first study utilizing ICP-MS with 32S element-specific detection for the analysis of vesicant chemical warfare agent degradation products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号