首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
Simple methods for the optimization of ion-exchange chromatography of proteins in our previous papers were applied to cation-exchange chromatography purification of monoclonal antibodies (Mab). We carried out linear gradient elution experiments, and obtained the data for the peak salt concentration and the peak width. From these data, the distribution coefficient as a function of salt concentration, and the height equivalent to a theoretical plate (HETP) as a function of mobile phase velocity were calculated. The optimized linear gradient elution conditions were determined based on the relationship between buffer consumption and separation time. The optimal stepwise elution conditions were determined based on the relationship between the distribution coefficient and the salt concentration.  相似文献   

2.
This paper examines protein ion-exchange behavior in electrokinetically-driven open-tubular chromatography with columns produced by immobilization of poly(aspartic acid) on capillary walls. Retention and selectivity are similar in the electrokinetic elution mode to that observed in HPLC. The separation mechanism was found to depend on the relationship of mobile phase pH to that of protein pI and ionic strength. Column efficiency in the electrokinetic elution mode was found to be 10-100-times higher than in HPLC. The best separations were achieved at intermediate ionic strength and high pH. The great advantage of these low-phase-ratio, high-efficiency open tubular columns is that isocratic separations in the electrokinetic elution mode were equivalent to gradient elution in the HPLC mode. Low phase ratio has the net effect of collapsing the chromatogram into a narrow elution window while the very high efficiency produces the requisite resolution.  相似文献   

3.
Gradient chromatofocusing is a recently developed chromatographic technique that overcomes the limitations of conventional chromatofocusing. This technique employs a HPLC gradient system and simple low-molecular-mass buffer components to generate linear or other function pH gradients on ion-exchange columns. Results of the present work show a superior separation of beta-lactoglobulin A and B in gradient chromatofocusing compared to salt gradient chromatography using the same DEAE column, with an optimized resolution of 2.3 obtained with gradient chromatofocusing compared to 1.1 obtained with NaCl gradients at constant pH. A significant advantage of the gradient chromatofocusing technique over the conventional chromatofocusing technique is its ability to employ a relatively wide range of buffer concentrations in the mobile phase, the effect of which is studied in the present work. Five proteins (conalbumin, ovalbumin, bovine serum albumin, beta-lactoglobulin A and B) are chromatographed on a DEAE-polymethacrylate HPLC anion-exchange column using the same approximately linear pH gradient profile but different mobile phase buffer concentrations. Results show a significant effect of buffer concentration on peak width, separation factor and resolution. For example, resolution increases from 1.5 to 2.3 in the separation of beta-lactoglobulin A and B when the concentration of each of the components in the 100% elution buffer is increased from 6.25 to 25.0 mM (with the same outlet pH gradient). This separation trend is also seen in the chromatography of ovalbumin from a commercial source, noting a progressive increase in resolution of two peaks in the sample (resolution increased from 0.7 to 2.4) when the concentration of each of the components in the 100% elution buffer is increased from 6.25 to 37.5 mM (same outlet pH gradient). The gains in the resolution are attributed to an increase in the separation factor, since the peak widths are generally noted to also increase with increased buffer concentration. These results point to a significant interplay between buffer concentration and pH, which is not effectively exploited in either conventional chromatofocusing or in conventional ion-exchange chromatographic procedures employing salt gradient elution at constant pH. Gradient chromatofocusing has the ability of optimizing both parameters, thus providing it with unique capabilities in protein separations.  相似文献   

4.
Although linear salt gradient elution ion-exchange chromatography (IEC) of proteins is commonly carried out with relatively short columns, it is still not clear how the column length affects the separation performance and the economics of the process. The separation performance can be adjusted by changing a combination of the column length, the gradient slope and the flow velocity. The same resolution can be obtained with a given column length with different combinations of the gradient slope and the flow velocity. This results in different separation time and elution volume at the same resolution. Based on our previous model, a method for determining the separation time and the elution volume relationship for the same resolution (iso-resolution curve) was developed. The effect of the column length and the mass transfer rate on the iso-resolution curve was examined. A long column and/or high mass transfer rate results in lesser elution volume. The resolution data with porous bead packed columns and monolithic columns were in good agreement with the calculated iso-resolution curves. Although the elution volume can be reduced with increasing column length, the pressure drop limits govern the optimum conditions.  相似文献   

5.
Fast protein liquid chromatography (FPLC) in combination with ion-exchange chromatography on a Mono Q column was used to purify glucose oxidase from Penicillium amagasakiense to homogeneity. Purification was performed with a mixed pH and salt gradient, with 20 mM phosphate buffer (pH 8.5) as starting buffer (A) and 50 mM acetate buffer (pH 3.6) with 0.1 M NaCl as elution buffer (B). Elution conditions were optimized to permit the simultaneous purification and separation of the glucose oxidase isoforms. Three peaks, each consisting of 1-2 isoforms and exhibiting a homogeneous titration curve profile, were resolved with a very flat linear gradient of 5.0-5.1% B in 40 ml. Three more peaks, each consisting of several isoforms, were eluted at 10%, 30% and 100% B. Optimization of the elution conditions and separation of the glucose oxidase isoforms was only possible because of the rapidity of each purification step and the high resolution provided by FPLC and Mono Q.  相似文献   

6.
A prepacked Superose 12 HR 10/30 column was used to study the effects of elution ionic strength and pH on the chromatographic behaviour of a strong hydrophobic Clostridium thermocellum endoglucanase (1) and two weak hydrophobic proteins, Clostridium thermocellum endoglucanase C and egg white lysozyme. Ion-exclusion or ion-exchange interactions between weakly hydrophobic proteins and the gel matrix were observed at low ionic strength, depending on whether the pH of the elution buffer was higher or lower than the pI values of the proteins. These interactions were due to the presence of negatively charged groups on the surface of Superose and could be eliminated at any pH by adding electrolyte at a concentration determined by its chemical identity. The optimum results were observed with sodium sulphate at a concentration of 100 mM. The chromatographic behaviour of strong hydrophobic endoglucanase (1) on a Superose column as a function of pH was much more complex because of two interplaying effects, electrostatic and hydrophobic. Ideal size-exclusion chromatography could be achieved only in a narrow range of the conditions: first, the mobile phase must contain a weak salting-out electrolyte such as NaCl, and second, the mobile phase pH must be high enough that hydrophobic interactions between the solute and support are balanced by their electrostatic repulsion. At pH greater than pI, the retardation of endoglucanase (1) gradually increased with decreasing pH as a result of lowering of repulsive electrostatic interactions whether or not the buffer ionic strength was high. At pH less than pI a drastic increase in the capacity factor k' was observed owing to the additivity of hydrophobic and ion-exchange effects.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

7.
We investigated protein separation by hydrophobic interaction chromatography (HIC) at low salt concentration on the supports of various hydrophobicities. Hydrophobic proteins could be successfully separated with more than 90% recovery by gradient elution of ammonium sulfate from 0.3-0.5 M to 0 in 50 mM phosphate buffer (pH 6.8) by using supports whose hydrophobicities were properly adjusted individually for each protein. Satisfactory results were also obtained by isocratic elution without ammonium sulfate and gradient elution of ethanol from 0 to 10%. HIC at low salt concentration was compatible with other modes of liquid chromatography like ion-exchange chromatography. On the other hand, it was not successful to separate hydrophilic proteins at low salt concentration. Recoveries of hydrophilic proteins decreased before they were retained enough as support hydrophobicity increased. Therefore, it is inevitable to use a higher concentration of salt, e.g., 1-2 M ammonium sulfate, on hydrophilic or moderately hydrophobic support in order to retain hydrophilic proteins without decrease in recovery.  相似文献   

8.
The retention of different physical forms of DNA by an electric field in a chromatography system was studied. We were able to effectively separate the supercoiled and the open circular forms of plasmid DNA using this type of electrochromatography system. Chromatography columns were packed with porous beads, and an axial electric field was applied so that convective buffer flow opposed the direction of electrophoresis of the DNA. A model system composed of approximately equal amounts of the super-coiled and open circular forms of the plasmid pBR 322 (4322 base pairs) was used to test the separation. Chromatography beads (agarose-based) with different porosities were used to determine the effect of the stationary phase on the separation. The porous media did not have a major effect on the separation, but the best separations were obtained using porous chromatography media made with the highest agarose concentration (10% agarose). Selective elution of plasmid DNA with different forms was obtained by either increasing the flow rates or decreasing the electric field strength (by steps or a gradient). In all the separations, the more compact supercoiled form of the plasmid was retained less strongly than either the open circular form (nicked) or the linear form. High molecular weight host genomic DNA was more strongly retained than the plasmid DNA. Increasing the ionic strength of the buffer improved resolution and capacity. The capacity of the separation was determined by injecting increasing amounts of plasmid DNA. Satisfactory separation was obtained at sample loading of up to 360 microg of total DNA on a column with dimensions of 2.5 by 11 cm (bed volume of 54 mL). The retention of DNA depends upon a counter-current flow of electrophoresis and convective flow and could be regarded as a type of field flow fractionation. The retention of the DNA by the electric field and flow is discussed in relation to the diffusion coefficients of the DNA.  相似文献   

9.
It has been shown earlier that the choice of displacing salt has a large effect on the retention in ion-exchange chromatography of proteins and peptides. The influence of different displacing salts cannot be predicted or quantitatively explained, owing to the current lack of an adequate theoretical framework. In this work a general characterization is made by using a considerable number of proteins and peptides and all displacing salts found feasible. Principal component analysis is used to interpret the large amount of data that is generated. The results of the analysis indicate that most of the retention variations are due to non-specific effects and can be explained by changes in the apparent gradient slope, i.e., the increase in elution strength per unit volume, and the elution strength of the starting buffer. This differs from the interpretation given earlier, where the selectivity changes were attributed to specific effects of the salts. However, as it is impossible to test all existing proteins and peptides, specific effects are still possible, but they might be less common than previously considered.  相似文献   

10.
This paper presents a methodology to gain process knowledge and assist in the robustness analysis of an ion-exchange step in a protein purification process using a model-based approach. Factorial experimental design is common practice in industry today to obtain robustness characterization of unit operations with respect to variations in process parameters. This work aims at providing a better insight into what process variations affect quality and to further reduce the experimental work to the regions of process variation that are of most interest. This methodology also greatly increases the ability to predict process performance and promotes process understanding. The model calibration part of the methodology involves three consecutive steps to calibrate a steric mass action (SMA) ion-exchange chromatography model. Firstly, a number of gradient elution experiments are performed. Secondly, experimental breakthrough curves have to be generated for the proteins if the adsorption capacity of the medium for each component is not known. Thirdly, a multi-component loading experiment is performed to calibrate the multi-component effects that cannot be determined from the single-component experiments. The separation process studied in this work is the separation of polyclonal IgG from a mixture containing IgG, myoglobin and BSA. The calibrated model is used to simulate six process variations in a full factorial experiment. The results of the simulations provide information about the importance of the different process variations and the simulations are also used to determine the crucial points for the process parameter variations. The methodology can be used to assist in the robustness analysis normally performed in the pharmaceutical industry today as it is able to predict the impact on process performance resulting from variations in salt concentration, column load, protein concentration and flow rate.  相似文献   

11.
A new analytical technique, gradient chromatofocusing-mass spectrometry (gCF-MS), was developed employing ion-exchange high-performance liquid chromatography (HPLC) interfaced to an electrospray-quadrupole mass spectrometer in the determination of proteins. There have been few reports, if any, of a HPLC-MS technique for proteins in which the ion-exchange column is directly interfaced to the mass spectrometer. The employment of a linear pH gradient elution scheme directly interfaced to mass spectrometry is also unique in the present work. The technique was demonstrated by the separation of six proteins (carbonic anhydrase II, enolase, beta-lactoglobulin A, lactoglobulin B, soybean trypsin inhibitor, and amyloglucosidase) employing a descending linear pH gradient from pH 9 to 2.6 on a 50 mm x 2.1 mm DEAE HPLC column using volatile buffer components. A signal enhancement solution consisting of 8% formic acid in acetonitrile was pumped post-column and was mixed 1:1 with column effluent and then directed on-line into the mass spectrometer. Molecular masses of the proteins were determined within +/-0.010% to 0.033% (+/-100 to 330 ppm) with peak height total ion current detection limits of 4 to 78 pmol of injected amounts (S/N = 3). This technique is applicable to the analysis of proteins and other charged molecules.  相似文献   

12.
Various modes of high-performance liquid chromatography, gel filtration, ion-exchange chromatography, hydrophobic interaction chromatography, reversed-phase chromatography and metal chelate affinity chromatography, were investigated for the separation of membrane proteins. All were found applicable to membrane proteins, although the usefulness of each mode differed. For satisfactory results it was important to select appropriate elution conditions. The type and concentration of detergent was of special importance. The effects of other conditions, flow-rate, gradient steepness, type of buffer and salt, eluent pH, etc., were similar to those observed for soluble proteins.  相似文献   

13.
When facing separation problems in ion chromatography, chromatographers often lack guidelines to decide a priori if isocratic elution will give enough separation in a reasonable analysis time or a gradient elution will be required. This situation may be solved by the prediction of retention in gradient elution mode by using isocratic experimental data. This work describes the development of an ion chromatographic gradient elution retention model for fluoride, chloride, nitrite, bromide, nitrate, sulfate and phosphate by using isocratic experimental data. The isocratic elution retention model was developed by applying a polynomial relation between the logarithm of the retention factor and logarithm of the concentration of competing ions; the gradient elution retention model was based on the stepwise numerical integration of the corresponding differential equation. It was shown that the developed gradient elution retention model was not significantly affected by transferring data form isocratic experiment. The root mean squared prediction error for gradient elution retention model was between 0.0863 for fluoride and 0.7027 for bromide proving a very good predictive ability of developed gradient elution retention model.  相似文献   

14.
A theoretical framework for the ion-exchange behaviour of bioactive substances in non-linear ion-exchange chromatogaphy is described. The aim of the study was the creation of a model basis to support a process design for production-scale ion-exchange chromatography. The theory can be applied to a whole variety of biological substances, such as amino acids, polysaccharides, peptides and proteins and either isocratic or gradient elution can be carried out. The influence of the eluent concentration on the ion-exchange as well as on the characteristic charge was considered. Experimental measurements showed a strong non-linear ion-exchange equilibrium with a transition from a Langmuir-type to a sigmoidal isotherm at higher eluent concentrations. Hereby, the compound binds to the surface though it is not ionic. Therefore, the model considered the possibility of ion-exchange as well as adsorption. A simplified distribution of the counter-ions based on the Gouy-Chapman theory with a discrete distribution of the counter-ions was used. The theory was extended by a selectivity in the double layer to allow specific adsorption. Calculations of adsorption-elution cycles showed, in agreement with the experimental observations, the development of non-linear elution profiles with a desorption fronting. As a result, the column loading and the eluent concentration were varied. The effect of contaminants, in this case sodium ions, was investigated and included in the model. Finally, the model was extended to multicomponent systems to investigate the effect of side components on the retention behaviour. The development of the characteristic elution profiles and the effect of the column loading on the separation are discussed. Calculated concentration profiles along the column at discrete time steps were used to reveal the influence of side components and the underlying separation mechanism. The simulations provided a new insight into the phenomena involved in biochromatography and make convenient design concepts at least doubtful as the separation is in this case mainly determined by the loading step and not by the choice of the elution gradient.  相似文献   

15.
The advantage of using a stepwise gradient of buffer concentration in CEC was demonstrated with the mixed-mode stationary phase, 3-(4-sulfo-1,8-naphthalimido)propyl-modified silyl silica gel (SNAIP). Before the application of a stepwise gradient, the effect of buffer concentration on the separations of six peptides and tryptic digests was investigated. Bubble formation caused by Joule heating at currents up to 95 microA was successfully suppressed by using SNAIP column even without pressurization, which contributed to a stepwise gradient of buffer concentration. Utilizing the stepwise gradient improved and shortened the separation of six peptides as compared to the separation under an isocratic elution.  相似文献   

16.
单亦初  张玉奎  赵瑞环 《色谱》2002,20(4):289-294
 根据溶质在柱内的迁移规律 ,建立了一种利用线性梯度实验快速获得溶质保留值方程系数 ,然后以串行响应函数为优化指标进行多台阶梯度分离条件优化的方法。与利用等度实验获得保留值方程的方法相比 ,该法可以大大缩短优化时间。通过该方法对芳香胺和衍生化氨基酸样品进行了分离 ,获得了满意的分离度 ,表明该方法的预测精度很好。  相似文献   

17.
In capacity gradient elution, the gradient separation of ionic species is achieved by decreasing the ion-exchange capacity of a column during the course of the separation. Diol-type hydroxy groups on the resin surface form anionic complexes with borate as an eluting reagent. Thus, a chemically bonded anion-exchange column enriched with residual hydroxy groups allows the creation of a capacity gradient. An increase in the amount of the complex formed gradually brings about a decrease in the ion-exchange capacity of the column, and strongly bound analyte ions are eluted. We investigated the characteristics of a column suitable for this eluent system. The concentration of borate eluent required to remove the ion-exchange capacity depended inversely on the ratio of the residual hydroxy groups to functional groups. On a column in which this ratio was approximately 100, the ion-exchange capacity could easily be adjusted by using a low concentration of mannitol as a competing reagent. Use of this column led to very small baseline shifts during the borate-mannitol gradients, and to the simultaneous determination of anions with widely varying retention times.  相似文献   

18.
In the present work, a 2-D capillary liquid chromatography method for fractionation and separation of human salivary proteins is demonstrated. Fractionation of proteins according to their pI values was performed in the 1-D employing a strong anion exchange (SAX) column subjected to a wide-range descending pH gradient. Polystyrene-divinylbenzene (PS-DVB) RP columns were used for focusing and subsequent separation of the proteins in the 2-D. The SAX column was presaturated with a high pH buffer (A) consisting of 10 mM amine buffering species, pH 9.0, and elution was performed with a low pH elution buffer (B) having the same buffer composition and concentration as buffer A, but pH 3.5. Isoelectric point fractions eluting from the 1-D column were trapped on PS-DVB trap columns prior to back-flushed elution onto the PS-DVB analytical column for separation of the proteins. The 1-D fraction eluting at pH 9.0-8.7 was chosen for further analysis. After separation on the RP analytical column, nine RP protein fractions were collected and tryptic digested for subsequent analyses by MALDI TOF MS and column switching capillary LC coupled to ESI TOF MS and ESI QTOF MS. Eight proteins and two peptides were identified in the pH 9.0-8.7 fraction using peptide mass fingerprinting and uninterpreted MS/MS data.  相似文献   

19.
A comparative study on weak anion exchangers was performed to investigate the pH dependence, binding strength, particle size distribution, and static and dynamic capacity of the chromatographic resins. The resins tested included: DEAE Sepharose FF, Poros 50 D, Fractogel EMD DEAE (M), MacroPrep DEAE Support, DEAE Ceramic HyperD 20, and Toyopearl DEAE 650 M. Testing was performed with five different model proteins: Anti-FVII mAb (immunoglobulin G), aprotinin, bovine serum albumin (BSA), Lipolase (Novozymes), and myoglobin. Retention showed an expected increasing trend as a function of pH for proteins with low pI. A decrease in retention was observed for some resins at pH 9 likely due to initiation of deprotonation of the weak anion-exchange ligands. Expected particle size distribution was obtained for all resins compared to previous studies. Binding strength to weak anion-exchange resins as a function of ionic strength depends on the specific protein. Binding and elution at low salt concentration may be performed with Toyopearl DEAE 650 M, while binding and elution at high salt concentration may be performed with MacroPrep DEAE Support. Highest binding capacities were generally obtained with Poros 50 D followed by DEAE Ceramic HyperD 20. A general good agreement was obtained between this study and data obtained by the suppliers. Verification of binding strength trends with model proteins was achieved with human growth hormone (hGH) and a hGH variant on the same resins with different elution salts, sodium chloride, sodium hydrogenphosphate, sodium sulphate, and sodium acetate. Static capacity measurements obtained in the traditional experimental set-up were compared with high-throughput screening (HTS) technique experiments with reasonable agreement. Isotherm data obtained from HTS techniques and pulse experiments were successfully combined with mathematical modelling to simulate, develop and optimise the separation process of two model proteins, Lipolase and BSA. The data presented in this paper may be used for selection of resins for testing in process development.  相似文献   

20.
The potential of 1.7 μm ethylene bridged hybrid silica phase was investigated for the separation of twelve imidazolium-based ionic liquid cations. U-shaped retention profile was observed for all solutes with an increase in retention at both low and high acetonitrile content. Chromatographic behaviour of imidazolium cations in both hydrophilic interaction chromatography (HILIC) and per aqueous liquid chromatography (PALC) modes was studied by varying key parameters such as buffer concentration and pH, acid additive, organic modifier and column temperature. Experimental data provided some evidences that under PALC conditions cationic solutes are retained predominantly by mixed hydrophobic/ion-exchange interactions. In the HILIC mode, both partitioning and ion-exchange interactions are responsible for the retention of solutes. Compared to PALC, HILIC provided significantly higher efficiencies with less or even no peak tailing, better separation selectivity and greater resistance to overload. In PALC mode gradient elution was required to achieve adequate retentivity of all solutes but selectivity was not sufficient to distinguish between solutes with very similar hydrophobicity. In contrast, under HILIC conditions twelve solutes were almost completely resolved in less than 4 min by using isocratic elution. Summarizing, it could be concluded that ethylene bridged hybrid silica column providing a dual retention mechanism offers the possibility of selecting between the two retention modes with opposite separation selectivity, just by changing the composition of the mobile phase.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号