首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A selective, simple and fast dispersive micro solid phase extraction method using magnetic graphene oxide (GO) as an efficient sorbent has been developed for the extraction, separation and speciation analysis of chromium ions. The method is based on different adsorption behaviour of Cr(VI) and Cr(III) species onto magnetic GO in aqueous solutions which allowed the selective separation and extraction of Cr(VI) in the pH range of 2.0–3.0. The retained Cr(VI) ions by the sorbent were eluted using 0.5 mL of 0.5 mol L?1 nitric acid solution in methanol and determined by ?ame atomic absorption spectrometry. Total chromium content was determined after the oxidation of Cr(III) to Cr(VI) by potassium permanganate. All effective parameters on the performance of the extraction process were thoroughly investigated and optimised. Under the optimised conditions, the method exhibited a linear dynamic range of 0.5–50.0 µg L?1 with a detection limit of 0.1 µg L?1 and pre-concentration factor of 200. The relative standard deviations of 3.8% and 4.6% (n = 8) were obtained at 25.0 µg L?1 level of Cr(VI) for intra- and inter-day analysis, respectively. The method was successfully applied to the speciation and determination of Cr(VI) and Cr(III) in environmental water samples.  相似文献   

2.
A novel adsorbent was developed from mature leaves of the Neem tree (Azadirachta Indica) for removing metal ions from water. The adsorbent, in the form of fine powder, was found to be very effective in removing chromium (VI) from aqueous solution. The adsorption was carried out in a batch process taking different concentrations of the metal ion in aqueous solution with variation in adsorbent amount, pH, agitation time and temperature. The suitability of the adsorbent was tested with Langmuir and Freundlich isotherms and with various equilibrium kinetic data. A small amount of the Neem Leaf Powder (NLP) (1.6 g dm–3) could remove as much as 87% of Cr (VI) in 300 min from a solution of concentration 14.1 mg dm–3 at 300 K. The optimum range of pH for the adsorption process was 4.5–7.5 and since the natural pH of the Cr (VI) solution was 5.5, no addition of acid or alkali was necessary for achieving maximum adsorption. The adsorption coefficients indicated a high potentiality for the NLP to be used as an adsorbent for removing Cr (VI) from water.  相似文献   

3.
Adsorption of Cr(VI) using activated neem leaves: kinetic studies   总被引:1,自引:0,他引:1  
In the present study, adsorbent is prepared from neem leaves and used for Cr(VI) removal from aqueous solutions. Neem leaves are activated by giving heat treatment and with the use of concentrated hydrochloric acid (36.5 wt%). The activated neem leaves are further treated with 100 mmol of copper solution. Batch adsorption studies demonstrate that the adsorbent prepared from neem leaves has a significant capacity for adsorption of Cr(VI) from aqueous solution. The parameters investigated in this study include pH, contact time, initial Cr(VI) concentration and adsorbent dosage. The adsorption of Cr(VI) is found to be maximum (99%) at low values of pH in the range of 1-3. A small amount of the neem leaves adsorbent (10 g/l) could remove as much as 99% of Cr(VI) from a solution of initial concentration 50 mg/l. The adsorption process of Cr(VI) is tested with Langmuir isotherm model. Application of the Langmuir isotherm to the system yielded maximum adsorption capacity of 62.97 mg/g. The dimensionless equilibrium parameter, R L, signifies a favorable adsorption of Cr(VI) on neem leaves adsorbent and is found to be between 0.0155 and 0.888 (0<R L<1). The adsorption process follows second order kinetics and the corresponding rate constant is found to be 0.00137 g/(mg) (min).  相似文献   

4.
Summary Synthetic Sorel's cement [3Mg(OH)2 . MgCl2 . 8H2O], is used as a new adsorbent material for removal of chromium(VI) ion from wastewater effluents. Parameters including contact time, adsorbent dosage and pH are examined and optimized. The equilibrium data are fitted very well to the Langmuir and Freundlich isotherms rather than linear. The adsorption isotherm indicates that the monolayer coverage is 21.4 mg Cr(VI) ion per g of Sorel's cement. The adsorbent is considered as a better replacement technology for removal of Cr(VI) ion from aqueous solutions due to its low cost, good efficiency, fast kinetics, and simple preparation. It offers remarkable efficiency for Cr(VI) removal from wastewater compared with many other natural and synthetic adsorbents.  相似文献   

5.
Tunçeli A  Türker AR 《Talanta》2002,57(6):1199-1204
A simple and sensitive method for the speciation, separation and preconcentration of Cr(VI) and Cr(III) in tap water was developed. Cr(VI) has been separated from Cr(III) and preconcentrated as its 1,5-diphenylcarbazone complex by using a column containing Amberlite XAD-16 resin and determined by FAAS. Total chromium has also been determined by FAAS after conversion of Cr(III) to Cr(VI) by oxidation with KMnO4. Then, Cr(III) has been calculated by subtracting Cr(VI) from the total. The effect of acidity, amount of adsorbent, eluent type and flow rate of the sample solution on to the preconcentration procedure has been investigated. The retained Cr(VI) complex was eluated with 10 ml of 0.05 mol l−1 H2SO4 solution in methanol. The recovery of Cr(VI) was 99.7±0.7 at 95% confidence level. The highest preconcentration factor was 25 for a 250 ml sample volume. The detection limit of Cr(VI) was found as 45 μg l−1. The adsorption capacity of the resin was found as 0.4 mg g−1 for Cr (VI). The effect of interfering ions has also been studied. The proposed method was applied to tap water samples and chromium species have been determined with the relative error <3%.  相似文献   

6.
The extraction of chromium (VI) ions from acidic solutions containing various metal ions by emulsion liquid membrane (ELM) was studied. Liquid membrane consists of a diluent, a surfactant, and an extractant. 0.5 M ammonium carbonate solution was used as stripping solution. Effects of acid concentration in feed solution, type and concentration of stripping solution, mixing speed, surfactant concentration, phase ratio and the influence of membrane characteristics were studied and optimum conditions were determined. Under the optimum conditions, extraction of chromium (VI) was tested and it was possible to selectively extract 99% of chromium from the acidic feed solution. This study also examined the effect of extractant concentration and acid type in the feed solution on the extraction of Cr (VI) ions and almost all of Cr (VI) from the acidic feed solution containing 500 mg/L from each of Co (II), Ni (II), Cd (II), Zn (II), and Cu (II) ions, and 100–500 mg/L Cr (VI) was extracted within 5–10 min.  相似文献   

7.
In this study, we report the synthesis of chromium imprinted polymer (Cr-IP) by a simple and facile one-pot precipitation polymerization technique by using 1-vinyl imidazole as ligand and methacrylic acid as functional monomer and their application for the specific removal of toxic hexavalent chromium from aqueous media. To attain maximum adsorption capacity various components i.e. functional monomer, cross-linker, and the molar ratio of ligand, monomer, and cross-linker were evaluate. Furthermore, several parameters i.e. pH, adsorbent dose, agitation time and shaking speed were also optimized to obtained maximum adsorption efficiency. The synthesized Cr-IP was characterized by SEM, EDX and FT-IR. The kinetic data were well described by pseudo-second-order while Langmuir model is best fitted to isotherm data. The maximum adsorption capacity of Cr-IP was 76.92mg/g. The relative standard deviation, limit of detection and quantification of this method was found to be 4.7%, 0.71µg/L and 2.36µg/L. The relative selective coefficient of Cr(VI) ions and competitive ions is greater than one due to the imprinting effect. This Cr-IP polymer also possesses good reproducibility and stability. The synthesized imprinted polymer has successfully applied for elimination of toxic Cr(VI) from real water samples.  相似文献   

8.
A natural peat has been used as an adsorbent for the removal of hexavalent chromium from aqueous solution. The peat was firstly characterized in terms of particle size and chemical composition (ash content, pH of the point of zero charge, FT-IR and thermal analysis). Next, the kinetic and equilibrium aspects of the adsorption of Cr(VI) by this adsorbent were studied. The kinetic data were satisfactorily fitted to a kinetic law of partial order in C equal to one. The specific adsorption rates are around 10(-4)s(-1), increasing as temperature does. A noticeable influence of diffusion on the global adsorption process has been demonstrated. Finally, the equilibrium isotherms were satisfactorily fitted to a previously proposed model. The adsorption capacity of Cr(VI) was similar to some other previously reported and the affinity of Cr(VI) towards the active sites of the adsorbent increases as temperature rises.  相似文献   

9.
10.
This study introduces a sensitive and simple method for selective adsorption of hexavalent chromium, Cr(VI), from water samples prior to its determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The method utilized activated carbon modified with tris(hydroxymethyl)aminomethane (AC-TRIS) as an adsorbent. Surface properties of the new chemically modified AC-TRIS phase were confirmed by Fourier transform infrared (FTIR) spectroscopy. Seven metal ions, including Co(II), Cu(II), Ni(II), Pb(II), Cr(III), Cr(VI), and Fe(III) were evaluated and determined at different pH values (1.0–8.0), except for Fe(III) at pH values (1.0–4.0). Based on the results of the effect of pH on adsorption of these metal ions on AC-TRIS, Cr(VI) was selected for the study of other parameters controlling its maximum uptake on AC-TRIS under batch conditions and at the optimum pH value 1.0. The maximum static adsorption capacity of Cr(VI) onto the AC-TRIS was found to be 43.30 mg g?1 at this pH and after 1 hour contact time. The adsorption data of Cr(VI) were modeled using both Langmuir and Freundlich classical adsorption isotherms. Results demonstrated that the adsorption of Cr(VI) onto AC-TRIS followed a pseudo second-order kinetic model. In addition, the efficiency of this methodology was confirmed by applying it to real environmental water samples.  相似文献   

11.
N,N'-bis-(α-methylsalicylidene)-2,2-dimethyl-1,3-propanediimine (SBTD) modified silica gel was prepared and used as sorbent for solid phase extraction of Cr(III) ions from aqueous solution. This sorbent showed a high sorption affinity for Cr(III) while recovery of Cr(VI) was very low. The analyte ion retained on the column was eluted with 1 mol L(-1) HNO(3). The chromium ion in the eluent was determined by graphite furnace atomic absorption spectrometry. The effects of different parameters such as pH, eluent type and volume, Schiff's base concentration, sample and eluent flow rate, interfering ions and adsorbent amount were investigated.  相似文献   

12.
The removal of Cr(VI) ions from aqueous solution by human hair waste is investigated by using UV–Vis spectrophotometer technique. The morphological analysis of the human hair was also investigated by the scanning electron microscopy, Fourier transforms infrared spectroscopy and X-ray photoelectron spectroscopy. The influence of various physicochemical effective parameters such as pH, ionic strength, adsorbent amount, contact time, initial concentration of metal ion on removal of Cr(VI) ions by human hair process was also studied. The optimum conditions for this adsorption process were obtained at pH = 2 and contact time of 150 min while the highest Cr(VI) uptake is recorded for 0.5 g of the adsorbent per 100 ml of solution. Three isotherms models including Langmuir, Freundlich and Temkin were applied to describe the equilibrium data. It was found that the experimental data were well described by Freundlich isothermal model. The maximum adsorption capacity was found to be 11.64 mg g?1.The thermodynamic study data showed that the adsorption process of Cr(VI) on human hair is an endothermic, spontaneous and physisorption reaction. The kinetics of the adsorption process was studied using three kinetics models including Lagergren-first-order, pseudo-second-order and Elovich model. The obtained data are indicated that the adsorption processes of Cr(VI) over human hair could be described by the pseudo-second-order kinetic model.  相似文献   

13.
水溶液中六价铬在碳纳米管上的吸附   总被引:6,自引:0,他引:6  
裘凯栋  黎维彬 《物理化学学报》2006,22(12):1542-1546
针对用碳纳米管对水溶液中六价铬的吸附净化进行了研究, 考察了溶液浓度、溶液pH值、共存的三价铬离子等因素对吸附行为的影响. 实验结果表明, 碳纳米管在室温下对于六价铬的吸附量随着平衡浓度的增大而升高, 在铬浓度为493.557 mg•L−1时碳纳米管吸附量达到最大值为532.215 mg•g−1; 六价铬的浓度在300~700 mg•L−1的范围内, 碳纳米管对铬的吸附量变化不大;大于700 mg•L−1时, 随着铬的平衡浓度的升高碳纳米管对铬的吸附量降低, 铬浓度为961.074 mg•L−1时, 碳纳米管吸附量降至194.631 mg•g−1. 在pH值为2~7的范围内, 碳纳米管对六价铬的吸附量随着溶液pH值的减小而增大; 而在碱性条件下, pH值对碳纳米管吸附六价铬的影响不大. 溶液中存在三价铬时, 碳纳米管对六价铬的吸附量明显降低, 表明三价铬与六价铬有竞争吸附. 此外, 活性炭的对比吸附实验表明, 在低浓度时, 譬如在六价铬浓度为190 mg•L−1吸附时, 碳纳米管对铬的吸附量约为活性炭的6倍;而在高浓度下, 譬如六价铬浓度为493 mg•L−1时, 碳纳米管对铬的吸附量约为活性炭的2倍.  相似文献   

14.
The appearance of chromium in the aqueous effluent is a major concern for the modern industry. In this work, Mesorhizobium amorphae strain CCNWGS0123 was investigated as a biosorbent to remove chromium from aqueous solutions. The optimum pH for Cr(III) and Cr(VI) biosorption were 4 and 2, respectively. This isolate showed an experimental maximum Cr(III) adsorption capacity of 53.52 mg?L?1, while the result was 47.67 mg?L?1 for Cr(VI), with an initial 100 mg?L?1 Cr ions and 1.0 g?L?1 biomass. In terms of time equilibrium, Cr(III) ion was more readily adsorbed than Cr(VI) by this isolate. The biosorption data of both ions fit the Langmuir isotherm better than that of Freundlich model. Meanwhile, this organism exhibited a good capability to release Cr ions, with desorption efficiency of 70 % for Cr(III) and 76 % for Cr(VI). Fourier transform infrared spectroscopy analysis showed that –OH, –COO, –NH, amide I, and C=O were involved in Cr(III) and Cr(VI) binding. The biosorbent was further characterized by scanning electron microscopy and energy-dispersive X-ray spectrometry, which indicated an accumulation of chromium on the cellular level. In the binary mixtures, the removal ratio of total Cr and Cr(III) increased from pH?2 to 4. The highest removal ratio of the total Cr was observed in the 25/25 mg?L?1 mixture at pH?4. In addition, the removal efficiency of Cr(VI) was closely influenced by Cr(III) in the mixture, decreasing to 23.57 mg?g?1 in the 100/100 mg?L?1 mixture system, due to the competition of Cr(III). The potential usage of the chromium-resistant rhizobium for the remediation of chromium-contaminated effluents has been demonstrated based on the above results.  相似文献   

15.
The removal of Cr (VI) from aqueous solutions using Alligator weed, a freshwater macrophyte, was investigated in batch studies. Various factors including solution pH, Cr (VI) concentrations, agitation time, and temperature were taken into account and promising results obtained. An initial solution pH of 1.0 was most favorable for Cr (VI) removal. The kinetic data were analyzed using several models, including the pseudo-second-order equation, external diffusion model, and intraparticle diffusion model. The comparison gave insight about the mechanism of adsorption and potential rate controlling step. The results suggested that the Cr (VI) adsorption at all temperatures was best represented by the pseudo-second-order equation. The external film diffusion played an important role in the adsorption mechanism. The Freundlich, Langmuir and Langmuir-Freundlich isotherms for the present system were analyzed. The best interpretation for the equilibrium data at different temperatures was given by the Langmuir-Freundlich isotherm. The Alligator weed could serve as low-cost adsorbent to remove Cr (VI) from aqueous solutions.  相似文献   

16.
Removal of Cr(VI) from Aqueous Solution Using Activated Cow Dung Carbon   总被引:1,自引:0,他引:1  
Removal of hexavalent chromium from aqueous medium by using activated cow dung carbon was studied. Cow dung was carbonized and activated by treating with concentrated H(2)SO(4) followed by heating for 24 h at 120 degrees C. The extent of adsorption was studied as a function of pH, contact time, amount of adsorbent, concentration of adsorbate, and temperature. At lower pH (<3.5), the prepared sorbent was capable of removing approximately 90% Cr(VI) at 5 ppm concentration from aqueous synthetic solution. The dynamics of migration of the sorbate ions from the bulk onto the sorbent surface was studied and the results obtained under various experimental conditions were found to follow standard adsorption isotherms. The reaction kinetics was found to be of first order. Copyright 2000 Academic Press.  相似文献   

17.
The applicability of thermal lens spectrometry (TLS) for quantification and routine determination of hexavalent chromium was investigated by using a collinear dual beam thermal lens spectrometer. In aqueous solutions the LOD of 0.1 μg l−1 was obtained for Cr(VI) by using 160 mW laser power. The performance of the technique was verified by the determination of hexavalent chromium in standard reference water samples (NIST SRM 1643a and NIST SRM 1643c) and comparing the results for Cr(VI) in CCA (Cr, Cu, As)-treated timber extracts to concentrations obtained by atomic absorption spectrometry (AAS). Good agreement between the TLS results and reported values for Cr(VI) in SRMs as well as AAS results for Cr(VI) in CCA-treated timbers confirmed that TLS is a reliable and accurate analytical technique applicable for the determination of Cr(VI) in aqueous solutions at concentration levels 0.5–100 μg l−1.  相似文献   

18.
A novel approach has been developed for the solid phase extraction of chromium(VI) based on the adsorption of its diphenylcarbazide complex on a mixture of acid activated montmorillonite (AAM)-silica gel column. The effect of various parameters such as acidity, stability of the column, sample volume, interfering ions, etc., were studied in detail. The adsorbed complex could be easily eluted using polyethylene glycol-sulfuric acid mixture and the concentration of chromium has been determined using visible spectrophotometry. The calibration graph was linear in the range 0-1microgmL(-1) chromium(VI) with a detection limit of 6microgL(-1). A highest preconcentration factor of 25 could be obtained for 250mL sample volume using glass wool as support for the mixed bed adsorbent. Chromium(VI) could be effectively separated from other ions such as nickel, copper, zinc, chloride, sulfate, nitrate, etc., and the method has been successfully applied to study the recovery of chromium in electroplating waste water and spiked water samples.  相似文献   

19.
In this paper, the modified magnetic chitosan resin containing diethylenetriamine functional groups (DETA-MCS) was used for the adsorption of uranium ions from aqueous solutions. The influence of experimental conditions such as contact time, pH value and initial uranium(VI) concentration was studied. The Langmuir, Freundlich, Sips and Dubinin–Radushkevich equations were used to check the fitting of adsorption data to the equilibrium isotherm. The best fit for U(VI) was obtained with the Sips model. Adsorption kinetics data were tested using pseudo-first-order and pseudo-second-order models. Kinetic studies showed that the adsorption followed the pseudo-second-order kinetic model, indicating that the chemical adsorption was the rate-limiting step. The present results suggest that DETA-MCS is an adsorbent for the efficient removal of uranium(VI) from aqueous solution.  相似文献   

20.
Calcium ferrite nanoparticles with super-paramagnetic behavior were synthesized via simple chemical precipitation method for effective removal of hexavalent chromium from aqueous media. The properties of synthesized nanoparticles were studied by X-ray diffraction (XRD), field emission scanning electron microscope (FESEM), Fourier transform infrared (FTIR) spectroscopy, Brunauer-Emmett-Teller (BET), and vibrating sample magnetometer (VSM) measurements. The ferrite nanoparticles have shown polycrystalline nature and high BET specific surface area (229.83 m2/g) with active functional groups on the surface. The adsorption process follows second-order kinetics with the involvement of intra-particle diffusion and adsorption capacity as much as 124.11 mg/g was determined from the Langmuir isotherm. The thermodynamic analysis revealed that the adsorption process was feasible, spontaneous, and exothermic in nature. A three-layer feed-forward back-propagation artificial neural network (ANN) model was employed to predict the removal (%) of Cr(VI) ions as output. Optimal ANN network (4:8:1) shows the minimum mean squared error (MSE) of 0.00161 and maximum coefficient of determination (R2) of 0.984. The adsorption process is mostly influenced by solution pH and followed by adsorbent dosage, initial Cr(VI) concentration, and contact time as illustrated by sensitivity analysis. With small size and high surface area, biocompatibility, ecofriendly nature, easy magnetic separation, and enhanced adsorption capacity towards Cr(VI), calcium ferrite nanoparticles will find its potential application in wastewater remediation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号