1.
Summary A simple, specific, and sensitive high-performance liquid chromatography method has been developed for simultaneous determination of the lomefloxacin, febufen, and felbinac in human plasma. Plasma-spiked with internal standard, was vortex-mixed for 1 min with a mixture of dichloromethane-diethylether (80:20, v/v). The evaporated extract was dissolved in 0.02 M NaOH. The extracts were chromatographed on an Supelcosil LCSAX column (5 m 250×4.6 mm I.D.) equipped with a guard column with a mibile phase composed of acetonitrile and phosphate buffer, with ultraviolet detection. Drugs were resolved at ambient temperature on a flow rate was 1.2 mL min–1, and monitoring was performed at 280 nm. The detection limits for lomefloxacin was 0.05 g mL–1, 0.02 g mL–1 for fenbufen and 0.03 g mL–1 for felbinac. No interference from other commonly administered drugs or endogenous substances was observed. The method is fast since it involves two extraction steps followed by evaporation of organic solvent and chromatography of the residue. This method was found to be applicable to pharmacokinetic and pharmacodynamic studies of each drug after the concomitant administration of lomefloxacin and febufen.  相似文献   

2.
We have extracted ten phthalate esters (C1 to C8) using six different micro-scale methods for extraction, and then separated them by capillary liquid chromatography coupled to UV detection. The methods included liquid-liquid extraction, ultrasonic-assisted extraction, microwave-assisted extraction, dispersive liquid-liquidmicroextraction, dispersive liquid-liquid microextraction solidification of floating organic droplets, and cloud point extraction. The linear range of the analytes is from 0.5 to 50 μg mL?1, and the detection limits range from 0.02 to ~0.17 μg mL?1. The precision and accuracy of all intra- and inter-day analyses are <5.5%. We find that dispersive liquid-liquid microextraction solidification of floating organic droplet (DLLME-SFO) is the best method for quantification of most phthalate esters in water samples and cosmetics because of its low limit of detection and high extraction efficiencies.
Figure
Phthalate esters were extracted by six micro-scale extraction methods and then determinated by capillary liquid chromatography coupled with ultraviolet detector (CapLC-UV).  相似文献   

3.
A magnetic sorbent was fabricated by coating the magnetized graphene oxide with polystyrene (PS) to obtain a sorbent of the type GO-Fe3O4@PS. The chemical composition and morphology of the sorbent were characterized. The sorbent was employed for the enrichment of polycyclic aromatic hydrocarbons (PAHs) from water samples. Various parameters affecting the enrichment were investigated. The PAHs were then quantified by gas chromatography with flame ionization detection. Linear responses were found in the range of 0.03–100 ng mL?1 for naphthalene and 2-methylnaphthalene, and of 0.01–100 ng mL?1 for fluorene and anthracene. The detection limits (at an S/N ratio of 3) range between 3 and 10 pg mL?1. The relative standard deviations (RSDs) for five replicates at three concentration levels (0.05, 5 and 50 ng mL?1) of analytes ranged from 4.9 to 7.4%. The method was applied to the analysis of spiked real water samples. Relative recoveries are between 95.8 and 99.5%, and RSD% are <8.4%.
Graphical abstract A magnetic sorbent was fabricated by polystyrene coated on the magnetic graphene oxide for the extraction and preconcentration of PAHs in water samples prior to their determination by gas chromatography with flame ionization detection.
  相似文献   

4.
Summary A method is proposed for the determination of 2-mercaptobenzothiazole in river waters using multi-electrode electrochemical detection HPLC. 2-mercaptobenzothiazole determination is unsatisfactory by gas chromatography as it degrades readily on the column. Multielectrode electrochemical detection HPLC combines sensitivity and the ability to screen out other electrochemically active species. The development work leading up to the proposed method is discussed. The method has a limit of detection of 0.798gl–1 2-mercaptobenzothiazole and a total standard deviation of 2.06gl–1 2-mercaptobenzothiazole at a concentration of 7.97gl–1 2-mercaptobenzothiazole in river water.  相似文献   

5.
Summary A capillary zone electrophoresis method has been developed for the determination of dextromethorphan and its metabolite, dextrorphan, in urine. A linear relationship was observed between the peak area and the concentration of both dextromethorphan and dextrorphan within the range of 490 ng mL–1 to 500 g mL–1 with a correlation coefficient of greater than 0.9999. The limit of detection was 80 ng mL–1 for both compounds. The inter-day coefficients of variation for the concentrations of 2.5 g mL–1 and 50 g mL–1 were 6.2% and 4.1% for dextromethorphan, and 5.6% and 2.8% for dextrorphan (n=15). The method could be applied directly to the determination of dextromethorphan and dextrorphan in human urine without any sample pretreatment for the elimination of interfering compounds as is required in published highperformance liquid chromatography and gas chromatography methods. Using dextromethorphan as a probe of the debrisoquin-oxidation metabolic phenotype, the 44 healthy volunteers were phenotyped after oral administration of a 15 mg dose using both this capillary electrophoresis method and a high-performance liquid chromatography assay from the literature. Good agreement was found between the two methods.  相似文献   

6.
A selective method is described for the determination of210Pb in sediments, based on the separation of the daughter210Bi by extraction chromatography with Microthene 710-tri-n-octylphosphine oxide (TOPO) and on a final source counting with a low background -counter. The average chemical yield is 92.0%. The detection limit for 2 g samples is 19 Bq kg–1. An IAEA reference sediment sample was analyzed to check the reliability of the method.  相似文献   

7.
A sensitive, specific, reproducible and optimized high performance liquid chromatography with fluorescence detection (HPLC-FLD) method for the determination of bergapten in rat plasma was established and applied to the pharmacokinetic and bioavailability study in rat after oral and intravenous administration of bergapten. The method was also successfully applied to the excretion study of bergapten after an oral administration of bergapten at a dose of 15 mg kg?1 to rats. The sample preparation was achieved using liquid–liquid extraction. Isoimperatorin was used as the internal standard (IS). The analytes were detected by using fluorescence detection at an excitation and emission wavelength of 288 and 478 nm, respectively. Using aqueous formic acid (0.1 %, v/v) and acetonitrile as the mobile phase, the chromatographic separation was achieved on a Hedera? ODS column at a flow rate of 1 mL min?1. The lower limit of quantitation (LLOQ) of bergapten was 2 ng mL?1. The HPLC-FLD method was successfully applied to the pharmacokinetic, bioavailability and excretion study of bergapten in rats.
Graphical abstract An high performance liquid chromatography with fluorescence detection (HPLC-FLD) method for the pharmacokinetic and bioavailability study in rat after administration of bergapten.
  相似文献   

8.
A method involving solid-phase micro extraction (SPME) and gas chromatography with electron capture detection (SPME–GC–ECD) has been optimised for identification and quantification of 2,4,6-trichloroanisole (TCA) at ng L–1 concentrations in disinfected (chlorinated) water samples. A central composite design was used for factorial analysis of four factors, three factors related to the SPME (PDMS fibre) procedure (adsorption time, temperature of the sample during headspace sampling, and desorption time) and one related to the GC operation (the rate of increase of the temperature of the GC oven). Good linearity (linear correlation coefficient greater than 0.999) was observed for TCA concentrations up to 50 ng L–1, limits of detection and quantification of 0.7 and 2.3 ng L–1, respectively, and good precision (relative standard deviation 2.8% and 3.4% for 5 and 30 ng L–1 of TCA, respectively). Besides TCA, this system also enables the detection and quantification of the four trihalomethanes in the g L–1 concentration range with limits of detection and quantification of approximately 0.3 g L–1 and 1 g L–1, respectively.  相似文献   

9.
Summary A simultaneous capillary Gas Chromatographic-Mass Spectrometric (GC-MS) method is described for the determination of thirteen pesticides belonging to the triazine and amide families in water. The sample is extracted in liquid-liquid mode (dichloromethane) and then the determination of the residues is carried out by capillary gas chromatography with mass spectrometric detection in the Selected-Ion Monitoring mode (SIM). The average recoveries of spiked compounds are in the 78.4–135.4% range between the relative low level (0.100 g L–1) and the relative high level (10.0 g L–1). The limits of detection (LOD) are in the 0.009–0.128 g L–1 range.  相似文献   

10.
A method for the determination of triphenyltin and diphenyltin was developed by reversed-phase high-performance liquid chromatography with UV detection. Triphenyltin and diphenyltin were separated using a reversed-phase Symmetry C18 column (150 × 3.9 mm, 5 m) with tetrahydrofuran-water-acetonitrile-glacial acetic acid (13:25:5:7, v/v) containing 0.05% triethylamine and 1.0% sodium acetate as mobile phase at 0.50 mL min–1 and detection at 257 nm. The calibration curves were linear from 0.26 mol L–1 to 1100 mol L–1 for triphenyltin with a correlation coefficient of 0.9999 (n=12) and from 0.60 mol L–1 to 1200 mol L–1 for diphenyltin with a correlation coefficient of 0.9991 (n=12), respectively. The detection limits of triphenyltin and diphenyltin were 0.2 mol L–1 and 0.4 mol L–1, respectively. The method was successfully applied to the determination of triphenyltin and its metabolite diphenyltin in culture medium. The recoveries of triphenyltin and diphenyltin were in the ranges of 97.7% to 103.3% and 85.5% to 91.6%, respectively.  相似文献   

11.
Online coupling of size exclusion chromatography together with medium resolution nuclear magnetic resonance (SEC‐MR‐NMR) might be one solution to the problem of chemically sensitive detection in liquid polymer chromatography. By use of a combination of SEC with a table‐top, specially designed 20 MHz NMR spectrometer, based on a permanent magnet, online 1H NMR spectra of SEC fractions can be obtained. The integration of digital filters, mechanical shims and electronic shims led to substantially improved sensitivity and chemical selectivity compared to former TD (time domain) 20 MHz instruments. 1H NMR spectra of PMMA and PS homopolymers as well as PS‐PMMA block copolymers were of sufficient quality to enable detection and de‐formulation of unknown polymer compounds. 1H NMR spectra of acceptable resolution and S/N ratio were collected online during the chromatography. The SEC separation online with the NMR measurements performed well and resulted in the proof of principle of the SEC‐MR‐NMR combination.

  相似文献   


12.
Summary The BIAcoreTM Biosensor System utilizes a detection principle known as Surface Plasmon Resonance (SPR) which, in simple terms, detects changes in the refractive index of a solution in contact with a gold film. The gold film is surface modified with carboxymethylated dextran to produce a hydrophillic matrix onto which macromolecules may be covalently immobilized. In this respect, the BIAcoreTM is similar to any other insoluble matrix, such as a chromatographic support. The SPR detection principle, however, allows one to directly visualize the interaction under study, in real time and without the need for reporter molecules such as enzyme-labels. In addition, the very small sample requirements, automated robotics unit and ease of data analysis suggest the potential use of the BIAcoreTM instrumentation for assay development and possibly process development, especially where bio-specific interactions such as immunoaffinity chromatography are used as a step in the process. In this report, we demonstrate the use of the BIAcoreTM SPR detector for the micro-scale determination of conditions for immunoaffinity chromatography of soluble complementreceptor 1, sCR1.  相似文献   

13.
A method based on stir bar sorptive extraction with liquid desorption combined with gas chromatography and mass spectrometry detection has been developed to determine a group of endocrine disruptors in water samples. Large volume injection was used with a programmed temperature vaporiser injector in gas chromatography to enhance sensitivity. The parameters affecting stir bar sorptive extraction and large volume injection were optimised. The limits of quantification in the full scan mode were between 0.02 and 0.2 g L–1 and the limits of detection were between 0.005 and 0.02 g L–1 for river water samples. The reproducibility between days of the method (n=3) for river water samples spiked at 0.2 g L–1 was below 15%. The performance of the method was checked with several water samples from the sea, and effluent and influent sewage treatment plants. We found 4-tert-octylphenol, benzylbutyl phthalate and bis(2-ethylhexyl) adipate in all the water samples analysed at levels between 0.02–14.04 g L–1. Diazinon was found in only one effluent wastewater sample at 0.16 g L–1.Acknowledgements This work was supported by the Ministerio de Ciencia y Tecnologia (projects AMB1999-0875 and PPQ2001-1805-CO3). We would like to thank Dr P. Sandra for kindly providing the stir bars.  相似文献   

14.
A new, simple and sensitive method was established for solid-phase extraction of benzoylurea insecticides including diflubenzuron, chlorbenzuron, triflumuron, flufenoxuron, and chlorfluazuron in water samples using TiO2 nanotubes cartridge prior to their determination by liquid chromatography. The parameters influencing the extraction were investigated and optimized. Under optimal conditions, a good linearity was found between the concentration and the peak area in the range from 0.2 to 40???g?L-1 (r2?>?0.99), and detection limits were in the range from 0.062 to 0.21???g?L-1. Real water samples were used for validating the method and recoveries of spiked samples were over the range from 82.0 to 100%. The results indicated that TiO2 nanotubes repesented an attractive alternative sorbent for the enrichment and trace analysis of such pollutants.
Figure
This paper established a new, simple and sensitive method for the determination of benzoylurea insecticides in water samples with solid-phase extraction using TiO2 nanotubes cartridge prior to high-performance liquid chromatography. Under optimal conditions, the detection limits were in the range of 0.062?C0.212 ??gL-1 for diflubenzuron, chlorbenzuron, triflumuron, flufenoxuron, and chlorfluazuron, respectively. Real water samples were used for validating the proposed method and good spiked recoveries are over the range of 82?C100.2%  相似文献   

15.
A new immunoassay has been developed based on a commercially available anti-caffeine monoclonal antibody and a de novo synthesized tracer, using horseradish peroxidase and UV–visible detection. Caffeine, which is frequently found in surface waters, can be quantified with a relative error lower than 20% for concentrations above 0.025 μg L?1 (limit of quantitation, direct analysis). The limit of detection is 0.001 μg L?1 and can be reduced by solid-phase extraction (SPE). Moreover, with minor adaptations, the assay can be used to quantify caffeine in several beverages, shampoo, and caffeine tablets. The results obtained by ELISA correlate well with those from liquid chromatography–tandem mass spectrometry (LC–MS–MS) for the tested matrices. Several surface waters from Berlin were analysed and all tested positive for caffeine, with concentrations higher than 0.030 μg L?1. In one run 66 samples can be analysed within 2 h.
Figure
A caffeine ELISA is described that allows sensitive and selective analysis of surface water concentrations as well as determination of caffeine in beverages.  相似文献   

16.
《Analytica chimica acta》2004,511(2):289-294
A piezoelectric detection system coupled with a liquid chromatographic system is developed for the speciation of inorganic mercury(II) and methylmercury. Piezoelectric detection has been demonstrated to be a very sensitive detection system for total mercury determination when a gold-coated piezoelectric quartz crystal was used. The analytical features of this detection unit make it very suitable to be used as a detector coupled with a liquid chromatographic system for monitoring mercury species. After separation by a chromatography column (Spherisorb ODS-2, 5 μm,  mm i.d.), mercury species are liberated and reduced, by using stannous chloride, and are detected as an amalgam on the gold-coated piezoelectric quartz crystal, the sensor subsequently was regenerated by passing a peroxydisulfate solution. This detector exhibits good sensitivity, it allows the determination of mercury at sub-ppb concentration levels (0.30-1.20 μg l−1). The precision, expressed as relative standard deviation, was ±2.7% (n=11) for a 0.5 μg l−1 total mercury concentration. The proposed method is free of interferences and it allowed the determination of inorganic mercury and methylmercury species in natural waters.  相似文献   

17.
A simple, reliable, and reproducible method for in-vivo on-line separation and determination of levodopa has been based on microdialysis then high-performance liquid chromatography with chemiluminescence detection. The perfusate is perfused at a flow rate of 5 L min–1. The concentration of levodopa in the dialysate is determined on line with a chemiluminescence system. The dialysate sample volume is approximately 20 L. The response of the system is linearly related to the concentration of levodopa in the range 1×10–8 to 1×10–6 g mL–1 (r2=0.9995) with a detection limit (3) of 3×10–9 g mL–1 and sample throughput of 12 h–1; RSD is 2.8% (n=11). The method has been successfully used to study the pharmacokinetics of levodopa in vivo; the values of the pharmacokinetics parameters Cmax, AUC0–t and Tmax were 16.60, 20.92 ng mL–1, and 90 min, respectively.  相似文献   

18.
Summary An automated method based on liquid chromatography has been developed for the determination of terbutaline in human plasma in the range of 5–50 pmole·ml–1. The necessary sensitivity and selectivity was obtained by using electrochemical detection and a microprocessor-controlled column switching system. A combination of three columns was used: a C8 type for pre-separation, a C18 type for trapping and, for final separation, a strongly acidic ion exchanger. The accuracy of the method was examined by comparison with a method based on gas chromatography — mass spectrometry. The overall precision was ±3.5% and ±2.2% respectively at 5 and 50 pmole·ml–1. The total absolute recovery for terbutaline and internal standard at the above concentration levels were in the range 85–106%.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

19.
An environmentally-friendly method has been established for simultaneous determination of sulfamonomethoxine, sulfadimethoxine, and their N4-acetyl metabolites in chicken plasma. The sample is prepared by mixing with 4 mol L–1 ammonium sulfate solution then centrifugation, and analysis is performed by high-performance liquid chromatography (HPLC) on a polyethylene glycol reversed-phase column with 0.001 mol L–1 sodium acetate solution as mobile phase and photodiode-array detection. Average recoveries from samples spiked with 0.1, 0.5, and 1.0 g mL–1 of each drug were >78% and relative standard deviations were within 4%. The practical quantitation limits were 0.09 g mL–1. No organic solvents or hazardous reagents were used at any stage of the analysis.  相似文献   

20.
Simultaneous analysis of homotaurine and its homologous, taurine, is a highly challenging issue, especially in matrices they exist simultaneously. A simple precolumn derivatization procedure combined with high-performance liquid chromatography–fluorescence detection was developed for simultaneous determination of homotaurine and taurine in marine macro-algae. The analytes were derivated with o-phthalaldehyde at an ambient temperature and alkaline medium. Calibration curves were linear in the ranges of 50–2500 µg L?1 for homotaurine and 100–2500 µg L?1 for taurine with the coefficients of determination higher than 0.998. Limits of detection of homotaurine and taurine were 15 and 30 µg L?1, respectively. Intraday (n = 6) and inter-day (n = 4) precisions of the method were satisfactory with relative standard deviations less than 6.0%. Good recoveries (>94%) were acquired by the method for extraction of homotaurine and taurine from algae matrices. Liquid chromatography–mass spectrometry was also used to confirm detection of the analytes in algae samples. The data suggest that the method was successfully applied to simultaneous determination of homotaurine and taurine in algae samples.  相似文献   