首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 140 毫秒
1.
SYPRO Tangerine stain is an environmentally benign alternative to conventional protein stains that does not require solvents such as methanol or acetic acid for effective protein visualization. Instead, proteins can be stained in a wide range of buffers, including phosphate-buffered saline or simply 150 mM NaCl using an easy, one-step procedure that does not require destaining. Stained proteins can be excited by ultraviolet light of about 300 nm or with visible light of about 490 nm. The fluorescence emission maximum of the dye is approximately 640 nm. Noncovalent binding of SYPRO Tangerine dye is mediated by sodium dodecyl sulfate (SDS) and to a lesser extent by hydrophobic amino acid residues in proteins. This is in stark contrast to acidic silver nitrate staining, which interacts predominantly with lysine residues or Coomassie Blue R, which in turn interacts primarily with arginine and lysine residues. The sensitivity of SYPRO Tangerine stain is similar to that of the SYPRO Red and SYPRO Orange stains - about 4-10 ng per protein band. This detection sensitivity is comparable to colloidal Coomassie blue staining and rapid silver staining procedures. Since proteins stained with SYPRO Tangerine dye are not fixed, they can easily be eluted from gels or utilized in zymographic assays, provided that SDS does not inactivate the protein of interest. This is demonstrated with in-gel detection of rabbit liver esterase activity using alpha-naphthyl acetate and Fast Blue BB dye as well as Escherichia coli beta-glucuronidase activity using ELF-97 beta-D-glucuronide. The dye is also suitable for staining proteins in gels prior to their transfer to membranes by electroblotting. Gentle staining conditions are expected to improve protein recovery after electroelution and to reduce the potential for artifactual protein modifications such as the alkylation of lysine and esterification of glutamate residues, which complicate interpretation of peptide fragment profiles generated by mass spectrometry.  相似文献   

2.
SYPRO Ruby dye is a permanent stain comprised of ruthenium as part of an organic complex that interacts noncovalently with proteins. SYPRO Ruby Protein Gel Stain provides a sensitive, gentle, fluorescence-based method for detecting proteins in one-dimensional and two-dimensional sodium dodecyl sulfate-polyacrylamide gels. Proteins are fixed, stained from 3h to overnight and then rinsed in deionized water or dilute methanol/acetic acid solution for 30 min. The stain can be visualized using a wide range of excitation sources commonly used in image analysis systems including a 302 nm UV-B transilluminator, 473 nm second harmonic generation (SHG) laser, 488 nm argon-ion laser, 532 nm yttrium-aluminum-garnet (YAG) laser, xenon arc lamp, blue fluorescent light bulb or blue light-emitting diode (LED). The sensitivity of SYPRO Ruby Protein Gel Stain is superior to colloidal Coomassie Brilliant Blue (CBB) stain or monobromobimane labeling and comparable with the highest sensitivity silver or zinc-imidazole staining procedures available. The linear dynamic range of SYPRO Ruby Protein Gel stain extends over three orders of magnitude, which is vastly superior to silver, zinc-imidazole, monobromobimane and CBB stain. The fluorescent stain does not contain superfluous chemicals (formaldehyde, glutaraldehyde, Tween-20) that frequently interfere with peptide identification in mass spectrometry. While peptide mass profiles are severely altered in protein samples prelabeled with monobromobimane, successful identification of proteins by peptide mass profiling using matrix-assisted laser desorption/ionization mass spectrometry was easily performed after protein detection with SYPRO Ruby Protein Gel stain.  相似文献   

3.
SYPRO Ruby IEF Protein Gel Stain is an ultrasensitive, luminescent stain optimized for the analysis of protein in isoelectric focusing gels. Proteins are stained in a ruthenium-containing metal complex overnight and then rinsed in distilled water for 2 h. Stained proteins can be excited by ultraviolet light of about 302 nm (UV-B transilluminator) or with visible light of about 470 nm. Fluorescence emission of the dye is maximal at approximately 610 nm. The sensitivity of the SYPRO Ruby IEF protein gel stain is superior to colloidal Coomassie blue stain and the highest sensitivity silver staining procedures available. The SYPRO Ruby IEF protein gel stain is suitable for staining proteins in nondenaturing or denaturing carrier ampholyte isoelectric focusing and immobilized pH gradient gel electrophoresis. The stain is compatible with N,N'-methylenebisacrylamide or piperazine diacylamide cross-linked polyacrylamide gels as well as with agarose gels and high tensile strength Duracryl gels. The stain does not contain extraneous chemicals (formaldehyde, glutaraldehyde, Tween-20) that frequently interfere with peptide identification in mass spectrometry. Successful identification of stained proteins by peptide mass profiling is demonstrated.  相似文献   

4.
As a noncovalent fluorescence probe, in this study, salicylaldehyde azine (SA) was introduced as a sensitive fluorescence‐based dye for detecting proteins both in 1D and 2D polyacrylamide electrophoresis gels. Down to 0.2 ng of single protein band could be detected within 1 h, which is similar to that of glutaraldehyde‐silver stain, but approximately four times higher than that of SYPRO Ruby fluorescent stain. Furthermore, comparative analysis of the MS compatibility of SA stain with SYPRO Ruby stain indicated that SA stain is compatible with the downstream of protein identification by LC‐MS/MS. Additionally, the probable mechanism of the SA stain was investigated by molecular docking. The results demonstrated that the interaction between SA and protein was mainly contributed by hydrogen bonding and hydrophobic forces.  相似文献   

5.
Jin LT  Hwang SY  Yoo GS  Choi JK 《Electrophoresis》2004,25(15):2494-2500
A highly sensitive silver staining method for detecting proteins in sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) was developed. It is based on the silver nitrate staining method but also employs an azo dye, calconcarboxylic acid (NN), as a silver-ion sensitizer. It increases silver binding on protein bands or spots by the formation of a silver-dye complex and also increases the reducing power of silver ions to metallic silver by NN itself with formaldehyde. After a 2 h gel fixing step, the protocol including sensitization, silver-ion impregnation, and reduction steps can be completed in 1 h. The sensitivity is superior to that of silver stain with glutardialdehyde as a silver-ion sensitizer. The detection limit of NN-silver stain is 0.05-0.2 ng protein. Considering the high sensitivity without using glutardialdehyde, the NN-silver stain would be useful for routine silver staining of proteins.  相似文献   

6.
Proteomic projects are often focused on the discovery of differentially expressed proteins between control and experimental samples. Most laboratories choose the approach of running two-dimensional (2-D) gels, analyzing them and identifying the differentially expressed proteins by in-gel digestion and mass spectrometry. To date, the available stains for visualizing proteins on 2-D gels have been less than ideal for these projects because of poor detection sensitivity (Coomassie blue stain) or poor peptide recovery from in-gel digests and mass spectrometry (silver stain), unless extra destaining and washing steps are included in the protocol. In addition, the limited dynamic range of these stains has made it difficult to rigorously and reliably determine subtle differences in protein quantities. SYPRO Ruby Protein Gel Stain is a novel, ruthenium-based fluorescent dye for the detection of proteins in sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) gels that has properties making it well suited to high-throughput proteomics projects. The advantages of SYPRO Ruby Protein Gel Stain relative to silver stain demonstrated in this study include a broad linear dynamic range and enhanced recovery of peptides from in-gel digests for matrix assisted laser desorption/ionization-time of flight (MALDI-TOF) mass spectrometry.  相似文献   

7.
Reactive dyeings were carried out by exhaust method on 100% cotton knits. A trichromatic combination was chosen with only change in blue component. Colorimetric data were produced under controlled dyeing conditions by comparing the color difference between the target shade and resulting shades. Giving a change in liquor ratio and nature of salt the colorimetric data were regenerated again produced the shades. The data will be helpful to predict the low-sensitivity reactive dye recipe, which lead to the concept of right-first-time dyeing. The aim of this research is to help a dyer to select the right recipe. A set of the dye recipes was applied by dyeing with reactive dyes on cotton. Sodium chloride shows best results in terms of dye sensitivity as compared to Glauber's salt at low liquor ratio that is 1:10. Blue BRF in combination with yellow and red shows best result as compared to navy blue BF.  相似文献   

8.
A red–green–blue (RGB) trichromophoric fluorescent organic nanoparticle exhibiting multi‐colour emission was constructed; the blue‐emitting cationic oligofluorene nanoparticle acted as an energy‐donor scaffold to undergo fluorescence resonance energy transfer (FRET) to a red‐emitting dye embedded in the nanoparticle (interior FRET) and to a green‐emitting dye adsorbed on the surface through electrostatic interactions (exterior FRET). Each FRET event occurs independently and is free from sequential FRET, thus the resultant dual‐FRET system exhibits multi‐colour emission, including white, in aqueous solution and film state. A characteristic white‐emissive nanoparticle showed visible responses upon perturbation of the exterior FRET efficiency by acceptor displacement, leading to highly sensitive responses toward polyanions in a ratiometric manner. Specifically, our system exhibits high sensitivity toward heparin with an extremely low detection limit.  相似文献   

9.
Choi JK  Chae HZ  Hwang SY  Choi HI  Jin LT  Yoo GS 《Electrophoresis》2004,25(7-8):1136-1141
A fast and matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) compatible protein staining method in one- and two-dimensional sodium dodecyl sulfate-polyacrylamide gel electrophoresis (1- and 2-D SDS-PAGE) is described. It is based on the counterion dye staining method that employs oppositely charged two dyes, zincon (ZC) and ethyl violet (EV) to form an ion-pair complex. The protocol, including fixing, staining and quick washing steps, can be completed in 1-1.5 h depending upon gel thickness. It has a sensitivity of 4-8 ng, comparable to that of colloidal Coomassie Brilliant Blue G (CBBG) staining with phosphoric acid in the staining solution. The counterion dye stain does not induce protein modifications that complicate interpretation of peptide mapping data from MS. Considering the speed, sensitivity and compatibility with MS, the counterion dye stain may be more practical than any other dye-based protein stains for routine proteomic researches.  相似文献   

10.
Visible stain is still the most popular protein staining method used in proteomic approaches. However, most published data have been derived from comparisons between visible dyes and fluorescent dyes. In this work, we have focused on seven widely used visible staining procedures—Neuhoff CCB, blue silver, and five silver stains (LKB SN, He SN, Yan SN, Vorum SN, and Blum SN)—and studied their stain efficiencies and MALDI-TOF MS compatibilities on 1-D and 2-D PAGE. It was concluded that blue silver is slightly better in terms of stain efficiency than Neuhoff CCB, but it presented worse MS compatibility. Neuhoff CCB presented better MS compatibility and superior linearity but worse sensitivity than silver stains. Among the five silvering procedures, He SN showed the best MS compatibility and a reasonable staining efficiency; Yan SN lowered the chances of obtaining the protein identity by PMF but gave the best stain efficiency; Vorum SN gave a very clear background and a great contrast, while Blum SN was the worst in this respect. The implications of these results for the selection of a convenient stain are discussed according to specific objectives as well as practical aspects.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号