首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
ET-AAS is investigated for the analysis of high purity mercury. Two possibilities are proposed: ET-AAS determination of trace analytes in the presence of high mercury concentrations or after matrix separation by reduction. The ET-AAS analysis of high-purity mercury under optimal instrumental parameters permits fast and reproducible determination of 0.03 gg–1 Al, Cd and Mn; 0.05 gg–1 Cu, Co, Cr, Fe, Ni and Pb and 0.2 gg–1 V. Preliminary mercury matrix reductive separation with ascorbic acid allows determination of 0.005 gg–1 Cd, 0.02 gg–1 Cu, Cr and Mn, 0.03 g g–1 Co, Ni and Pb, 0.05 g g–1 Al and Fe and 0.1 gg–1 V, but the reproducibility is lower. The main advantage of the second procedure is that it avoids laboratory and instrument pollution with toxic mercury.  相似文献   

2.
The interference contributions of uranium and thorium to the determination of cerium based on radionuclides141Ce and143Ce produced by irradiation in a reactor core was determined. The values of the interference contributions for141Ce were 0.28±0.01 g Ce/g U and /2.01±0.05/x10–3 g Ce/g Th, and for143Ce 1.33±0.03 g Ce/g U and /9.0±0.2/x10–3 g Ce/g Th.  相似文献   

3.
This is a report of simple estimations of natural thorium in low level effluents generated during the reprocessing of irradiated Th/ThO2 rods for the recovery of233U. The method involved co-precipitation of thorium with ceric iodate at pH 1.29±0.01 and subsequent photometric determination. Conditions were optimised to eliminate the interferences of other ions present in the effluent. Approximately 15 mg each of phosphate, fluoride, and sulphate, 10 mg of iron, and 300 g zirconium did not interfere in the estimation of 2–5 g Th/100 ml of the effluent. Average thorium recovery was around 101.9%±2.6% when nearly 10 g of thorium were spiked.  相似文献   

4.
Zusammenfassung Die bis heute in der Literatur mitgeteilten Werte für Chrom im Serum nüchterner gesunder Probanden unterscheiden sich um Größenordnungen. Die in der vorliegenden Arbeit mitgeteilten Untersuchungen betreffen die analytische Problematik der Chrombestimmung mit Hilfe der flammenlosen Atomabsorptions-Spektrometrie, wobei aufgezeigt wird, daß diese Methodik für die Chrombestimmung in biologischem Material ohne großen statistischen Aufwand zu keiner sicheren Beurteilbarkeit und Interpretierbarkeit der gemessenen Werte führt. Mit Hilfe synthetischer Chromkomplexverbindungen werden die Probleme der Standardaddition zur Chrombestimmung untersucht. Unter Berücksichtigung der Blindwerte und der daraus resultierenden Nachweisgrenze sowie Garantiegrenze für Reinheit, wurde Chrom in einem Standardreferenzmaterial (1569 Brewers yeast [U. S. National Bureau of Standards]) im Rahmen eines Ringversuchs zur Chromanalyse sowie im Serum und Plasma von 41 Probanden bestimmt. Für das Referenzmaterial wurde ein Wert von 45±4 mol/kg (2,3±0,2 g/g) ermittelt. Der Referenzwert betrug 41±1 mol/kg (2,12±0,05 g/g). Im Serum wird eine lognormale Verteilung der Chromkonzentration mit den zentralen Parametern ±_M=132,2 nmol/l (0,72,2 g/l) ermittelt. Im Plasma lagen die Werte zwischen 20 und 30 nmol/l (1–1,5 g/l). Aufschluß, Durchführung der Bestimmung sowie die biologische Bedeutung und Interpretation des Parameters Chrom im Serum und Plasma werden eingehend diskutiert.
Determination of chromium in human serum and plasma by flame-less atomic-absorption spectrophotometry
Summary Concentrations of Cr in serum of overnight fasting volunteers differ over a wide range in the literature. The investigations of the analytical problems of Cr determination by flameless atomic absorption spectrometry underline the necessity of statistical methods for the interpretation of the measurements of Cr in biological matrices. With nine different synthetic chromium complexes the method of standard addition was investigated. Considering the blank values, the limit of detection and the limit of guarantee for purity, Cr was determined in the standard reference material 1569 brewers yeast (National Bureau of Standards) with 45±4 Mol · kg–1 (2.3±0.2g·g–1), compared with the reference data 41±1 Mol·kg–1 (2.12±0.05 g±g–1). In serumuuuuu we found a lognormal distribution with the central parameters 132.2 nMol ·1–1 (0.72.2 g·1–1). In plasma the values were in the range between 20 and 30 nMol·1–1 (1–1.5 g·1–1). The ashing process and the determination are demonstrated and discussed in detail.
  相似文献   

5.
Zusammenfassung Die Bestimmung von 800 bis 30g Pb(II) durch potentiometrische Titration mit Molybdat unter Verwendung einer bleispezifischen Elektrode wurde untersucht. Unter geeigneten Bedingungen sind mit 4·10–3 M Molybdat 800 bis 300g Pb(II) in wäßriger Lösung mit einer Genauigkeit von ±0,57% bzw. 0,45% und einer Reproduzierbarkeit von ±0,43% bzw. ±0,30% (Standardabweichung=0,25% bzw. 0,17%) je nach Titrationsart automatisch bzw. manuell bestimmbar.Zur Bestimmung von Pb(II)-Mengen <300g ist eine 2·10–3 M Molybdatlösung zu verwenden. 300 bis 100g Pb(II) sind in wäßriger Lösung mit zufriedenstellenden Resultaten bestimmbar, jedoch verbessert eine Titration in 40% igem Ethanol nicht nur die Genauigkeit in diesem Bereich, sondern erlaubt auch noch 30g Pb(II) mit einer Genauigkeit von ±1% und einer Reproduzierbarkeit von ±2% (Standardabweichung aus 20 Titrationen von 100g Pb(II)= 0,60%) zu bestimmen.Die Titration von 300–800g Pb(II) in wäßriger Lösung und von 30–300g Pb(II) in 40% igem Ethanol läßt sich auch in 0,1M NaNO3– 0,1M NaClO4– Lösung durchführen und ermöglicht somit auch zuverlässige Bleibestimmungen in organischen Verbindungen nach Mineralisierung mit HNO3–HClO4–H2O2.
The determination of 800 to 30 g lead(II) by potentiometric titration with molybdate
Summary The determination of 800 to 30g Pb(II) by potentiometric titration with molybdate by using a lead(II)-selective electrode was investigated. Under suitable conditions, 800 to 300g Pb(II) in aqueous solution by automatic or manual titration with 4·10–3 M molybdate can be determined with an accuracy of ±0.57% and ±0.45% and a precision of ±0.43% and 0.30% (standard deviation=0.25% and 0.17%, resp.).For determining amounts of Pb(II) below 300g, a 2·10–3 M molybdate solution has to be used. Although 300 to 100g Pb(II) are determinable again in water with satisfactory results, the titration in 40% ethanol is however more reliable: in this medium, amounts of 300 to 30g Pb(II) can be determined with an accuracy of ±1% and a precision of ±2% (standard deviation from 20 titrations of 100g Pb(II)=0.60%).The titration of 300–800g Pb(II) in water and of 30–300g Pb(II) in 40% ethanol is also possible in 0.1M NaNO3– and 0.1M NaClO1– medium and can be used in the lead determination in organic compounds after mineralization with HNO3-HClO4-H2O2.
  相似文献   

6.
Summary A precise, accurate procedure is proposed for the determination of arsenic in mussel products by inductively coupled plasma atomic emission spectrometry. Organic matter is destroyed by dry ashing. Experimental conditions for the determination of arsenic were selected and an interference study was carried out. The methodology developed has a detection limit of 0.1 g g–1, a relative standard deviation of 3%, and a recovery percentage of 98±2%. The accuracy of the method was checked by analysis of a certified sample of NIST oyster tissue (certified 14.0±1.2 g g–1; found 14.1±1.1 g g–1). The proposed procedure was used to analyze real samples of mussel products.  相似文献   

7.
A prompt-gamma neutron activation technique has been developed using the (n, ) apparatus situated at the O degree through-tube of the Imperial College CONSORT II Reactor with a thermal neutron flux at the target position of approximately 2×106 n cm–2 sec–1, and a Compton-suppression system involving a lithium-drifted germanium (Ge(Li)) detector and a sodium iodide anti-Compton shield. Boron levels of 1–5 g g–1 (detection limit 0.05 g B for 10,000 sec period of measurement) can be attained using the Compton-suppression system with graphical inter-polation correction for the 472 keV sodium-ray peak contribution to the Doppler-broadened 478 keV boron gamma-ray peak resulting from the10B(n, )7Li reaction. Very good agreement is reached for boron levels compared using this system for various Standard Reference Materials and other published values. Measurement of the boron content of bone and tooth samples from rheumatoid arthritis individuals shows lower levels, (p<0.05); 16.13±7.53 g g–1, when compared with a control population; 19.79±4.18 g g–1. A positive correlation existed between the boron content of bone and tooth material for each study group. Results indicate that boron availability may be associated with rheumatoid arthritis.  相似文献   

8.
    
Summary Optimum for the generation of arsine from As(III) and (V) in a generating system without carrier gas and with atomization in an air-acetylene flame were established. A 3% solution of NaBH4 was used as reducer. The effect of 26 different species on the determination of arsenic was studied. The method has been applied to determine arsenic in copper.A linear relationship exists between 0.5 and 3 g for As(III) and between 1 and 4 total g of As(V). The sensitivity, expressed as the slope of the calibration curve is 0.067 g–1 for As(III) and 0.054 g–1 for As(V); the characteristic masses are 1.22 g and 0.44 g, and the limits of detection 0.27 g and 0.33 g, respectively.
Direkte Flammen-AAS — Erzeugung flüchtiger kovalenter HydrideStörungen durch das Verhältnis der As(III/V)-Valenzstufen und Arsenbestimmung in Kupfer
Zusammenfassung Optimale Bedingungen wurden ausgearbeitet für die Arsinerzeugung aus As(III) und As(V) in einem System ohne Trägergas mit Atomisierung in einer Luft-Acetylen-Flamme. Zur Reduktion dient eine 3%ige NaBH4-Lösung. Der Einfluß von 26 Fremdionen wurde geprüft und das Verfahren zur Arsenbestimmung in Kupfer angewendet. Eine lineare Beziehung ergab sich für 0,5–3 g As(III) und 1–4 g As(V). Die Empfindlichkeit (als Neigung der Eichkurve) beträgt 0,067 g–1 für As(III) und 0,054 g–1 für As(V). Die charakteristischen Massen sind 1,22 g bzw. 0,44 g und die Nachweisgrenzen 0,27 g bzw. 0,33 g.


This work has been sponsored by the CAICYT (project 3378/83) of the Spanish Education and Science Department.  相似文献   

9.
The aim of this work was to determine the concentrations of some essential and toxic elements in the muscle of ten species of commercial fish consumed in Portugal. We combined two different techniques for determination of the elements—energy-dispersive X-ray fluorescence (EDXRF) was used to quantify K, Ca, Fe, Zn, Se, Rb, and Sr and flame atomic-absorption spectrometry for analysis of Cr, Ni, Cu, Cd, Hg, and Pb. The latter technique was used because of its higher sensitivity, because these elements were not detected by EDXRF. The results obtained show a similar pattern for the trace elements. K and Ca are present at the highest concentrations in all the samples studied, from 0.6–1.3% and from 0.04–0.08%, respectively, followed by Zn, Fe, Sr, Se, and Rb. Sr is present at higher concentrations than Rb in all the species studied except meagre. Concentrations of the elements in octopus do not follow this pattern—Fe is present at a higher concentration than Zn. Low concentrations of Cr (0.66–1.5 g g–1), Ni (0.11–0.24 g g–1), Cd (0.01–0.08 g g–1), Hg (0.49–2.74 g g–1), and Pb (0.02–0.06 g g–1) were observed in all the samples analysed. The concentration of Hg was highest in Helicolenus dactylopterus—5.4 g g–1 in one sample.  相似文献   

10.
The intake and tissue distribution of thorium (2 3 2Th) was studied in an urban (Bombay) population in India. From the analysis of 16 whole diet samples, the average daily intake through food was found to be 2 g (range 0.8–4.3 g·d–1). The estimated intake through drinking water and inhalation comes out to be 0.03 and 0.02 g per day. From the analysis of human autopsy tissue samples it is observed that the concentration ranges in lungs and bone are 1.5–16 g/kg and 0.2–9.0 g/kg fresh weight respectively. The average urinary concentration is 12 ng/1 (range 7–22 ng/l for 10 samples). Among the different body tissues, pulmonary lymph nodes were found to contain the highest concentration (geometric mean 53.4 g/kg, range 31.4–85.5 g/kg for 6 samples). Analysis of the samples was done by the neutron activation technique. 311.8 keV gamma photons of2 3 3Pa which is the activation product of2 3 2Th, were counted after chemical separation. A 54 cm3 intrinsic Ge detector coupled to 1024-channel analyser was used. Using the average lung content and the daily average intake values of thorium through inhalation, the clearance half-time from lung was estimated.  相似文献   

11.
Summary A semi-automatic potentiometric method is described for the catalytic titrimetric determination ofg amounts of some aminopolycarboxylic acids. The method is based on their inhibitory effect on the copper(II)-catalyzed periodate-thiosulfate reaction. Amounts of EDTA in the 0.7–600g range (10–6–8×10–5 M), of DCTA in the 7–7000g range (10–6–10–3 M), of EGTA in the 0.8–800g range (10–7–10–4 M), and of DTPA in the 4–800g range (5×10–7–10–4 M) were determined with average relative errors and coefficient of variation of about 0.4–1%. The method has also been used for the indirect catalytic titrimetric determination ofg amounts of Cu2+ and Co2+ ions with about the before mentioned accuracy and precision.
Halbautomatische katalytische Titration einiger Aminopolycarbonsäuren sowie von Cu(II) und Co(II)
Zusammenfassung Eine halbautomatische potentiometrische Methode zur katalytischen Maßanalyse von Mikrogrammengen einiger Aminopolycarbonsäuren wurde angegeben. Sie beruht auf dem Hinderungseffekt gegenüber der Cu(II)katalysierten Perjodat-Thiosulfatreaktion. EDTA in Mengen von 0,7–600g, DCTA in Mengen von 7–7000g, EGTA in Mengen von 0,8–800g und DTPA in Mengen von 4–800g wurden mit einem mittleren relativen Fehler von etwa 0,4–1% bestimmt. Das Verfahren wurde auch zur Bestimmung von Cu(II) und Co(II) mit der angeführten Genauigkeit verwendet.
  相似文献   

12.
The optimum conditions for the extractive spectrophotometric determination of dioxouranium(VI) with hexamethyleneiminecarbodithioate(HMICdt) have been established. Dioxouranium(VI) reacts with this ligand at pH 4.5 to form a yellowish-orange uncharged 12 metal-ligand complex which can be extracted by chloroform. The calibration graph was linear in the range of 1–20 g ml–1 of dioxouranium(VI) at 335 nm. The molar absorptivity of the extracted species is 5.952×103 l mol–1 cm–1 with Sandell's sensitivity of 0.04 g cm–2. The average of 10 determinations of dioxouranium was 49.75 g for the samples containing 50 g of U(VI) and the variation from the mean at 95% confidence limit was 49.75±0.5955.  相似文献   

13.
Inductively coupled plasma-mass spectrometry (ICP-MS) was used to determine the concentration of platinum (Pt) in silicone breast implant gel (range, 0.26–48.90 g g–1 Pt; n=15), elastomer (range, 3.05–28.78 g g–1 Pt; n=7), double lumen (range, 5.79–125.27 g g–1 Pt; n=7), foam (range, 5.79–8.36 g g–1 Pt; n=2), and capsular tissue (range, 0.003–0.272 g g–1 Pt; n=15). The results show that very high levels of Pt are present in the encasing elastomer, double lumen, and foam envelope materials. Silicone breast implants can be a source of significant Pt exposure for individuals with these implants.  相似文献   

14.
The aim of the present study was to develop a sensitive method to measure dextromethorphan and dextrorphan in urine by HPLC to support pharmacogenetic studies in ethnic groups. Linearity was assessed in the range: 0.015–10 g mL–1 for dextromethorphan and 1-10 g mL–1 for dextrorphan. Inter and intra-day coefficients of variation were < 10%. Limits of detection and quantitation were 0.003 g mL–1 and 0.015 g mL–1 for dextromethorphan and 0.24 g mL–1 and 1.0 g mL–1 for dextrorphan, respectively. The method is reliable in helping determine the phenotype of Mexican ethnic groups using model drugs such as dextromethorphan.  相似文献   

15.
Thorium(IV) reacts with 1-(2-thiazolylazo)-2-naphthol (TAN) in the presence of antipyrine to form a sparingly soluble red-coloured chelate, soluble in 36% methanol (v/v). Complexation takes place instantaneously at pH 2.4–2.8, maintained by glycine buffer. Antipyrine is found to enhance sensitivity of the complex, which is stable for 19 hours. The 12 complex exhibits maximum absorbance at 555 nm, obyes Beer's law in the concentration range from 0.32 to 6.56 g of thorium(IV) per ml, has a molar absorptivity of 3.14·104 dm3/mol–1·cm–1 and a Sandel sensitivity of 7.4 ng·cm–2. The formation constant (log K) is found to be 8.62 and 8.45. Interference of 57 anions and cations in the determination of thorium(IV) has been studied. From ten repeated determinations, the coefficient of variation was found to be ±0.98%. The method was successfully applied for determination of thorium content in a sample of monazite.  相似文献   

16.
The complexation of UO2 +2 and Th+4 ions with 2-mercaptoethanol has been studied by potentiometric and conductometric titration techniques. Uranyl ion forms 11 and 12 complexes in the pH-range 3.3–6.5 and thorium ion forms 12, 13, and 14 complexes in the pH-range 3.2–4.8 with considerable overlapping. Their logk stab. values are determined at 10, 20, and 30°C at ionic strength =0.1M (NaClO4) by applyingCalvin-Melchior's extension of theBjerrum method. The overall changes in thermodynamic functions G, H, and S accompanying complexation determined at 20°C are –19.48 kcal/mole, –22.77 kcal/mole, –11.23 cal/deg·mole for uranyl complexes and –33.94 kcal/mole, –4.93 kcal/mole, 99.00 kcal/deg·mole for thorium complexes, resp.  相似文献   

17.
Using the 871-keV16O p/1,0/ prompt -ray, oxygen was determined with a relative precision of ±3.8% at a concentration level of 120 g g–1. The sensitivity of the method is below 10 g g–1. 50 nm oxide layers on silicon wafers can be determined with a relative precision of 10%. A chamber for transporting targets sensitive to atmospheric gases and humidity is described.  相似文献   

18.
Summary A method is proposed for the determination of 2-mercaptobenzothiazole in river waters using multi-electrode electrochemical detection HPLC. 2-mercaptobenzothiazole determination is unsatisfactory by gas chromatography as it degrades readily on the column. Multielectrode electrochemical detection HPLC combines sensitivity and the ability to screen out other electrochemically active species. The development work leading up to the proposed method is discussed. The method has a limit of detection of 0.798gl–1 2-mercaptobenzothiazole and a total standard deviation of 2.06gl–1 2-mercaptobenzothiazole at a concentration of 7.97gl–1 2-mercaptobenzothiazole in river water.  相似文献   

19.
Instrumental neutron activation analysis (INAA) was applied to the rapid determination of magnesium in the botanical reference materials Beech Leaves-100 and Spruce Needles-101. The magnesium content was quantitatively determined by measuring the gamma-ray photopeak at 1014 keV of the short-lived radionuclide27Mg (9.46 m). The magnesium concentrations in the two materials were found to be 834.6±50.2 g·g–1 dry weight and 618.6±36.2 g·g–1, respectively. When assaying a 0.1 g sample under the same experimental conditions the limit of detection is 30 g of Mg.Work carried out at Risø National Laboratory, Isotopes Division, DK-4000 Roskilde, Denmark.  相似文献   

20.
Summary The red complex formed between chromium(III) and 4-(2-thiazolylazo)-resorcinol (1 2) at pH 5.0, on heating the reactants to 90° for 45 minutes, is used for Spectrophotometric determination of chromium, the absorbance being measured at 525 nm. Beer's law is obeyed for chromium concentration of 0.06 to 1.1g per ml. Molar absorptivity is 4.98×104 and Sandell sensitivity 0.001g cm–2. This method has been applied to the determination of chromium content in steel samples.
Zusammenfassung Der 1 2-Komplex von Chrom(III) mit 4-(2-Thiazolylazo)resorcin bildet sich bei pH 5,0 und 90° C in 45 min. Er eignet sich zur spektrophotometrischen Chrombestimmung. Die Extinktion wird bei 525 nm gemessen. Das Beersche Gesetz ist zwischen 0,06 und 1,1g Cr/ml erfüllt. Die molare Extinktion beträgt 4,98 · 104, die Empfindlichkeit nach Sandell 0,0001g · cm–2. Die Methode wurde zur Chrombestimmung in Stahlproben angewandt.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号