1.
Basic operation principles of a lightweight, low power, low cost, portable ion chromatograph utilizing open tubular ion chromatography in capillary columns coated with multi-layer polymeric stationary phases are demonstrated. A minimalistic configuration of a portable IC instrument was developed that does not require any chromatographic eluent delivery system, nor sample injection device as it uses gravity-based eluent flow and hydrodynamic sample injection adopted from capillary electrophoresis. As a detection device, an inexpensive commercially available capacitance sensor is used that has been shown to be a suitable substitute for contactless conductivity detection in capillary separation systems. The built-in temperature sensor allows for baseline drift correction typically encountered in conductivity/capacitance measurements without thermostating device. The whole instrument does not require any power supply for its operation, except the detection and data acquisition part that is provided by a USB port of a Netbook computer. It is extremely lightweight, its total weight including the Netbook computer is less than 2.5 kg and it can be continuously operated for more than 8 h. Several parameters of the instrument, such as detection cell design, eluent delivery systems and data treatment were optimized as well as the composition of eluent for non-suppressed ion chromatographic analysis of common inorganic cations (Na+, NH4+, K+, Cs+, Ca2+, Mg2+, transition metals). Low conductivity eluents based on weakly complexing organic acids such as tartaric, oxalic or pyridine-2,6-dicarboxylic acids were used with contactless capacitance detection for simultaneous separation of mono- and divalent cations. Separation of Na+ and NH4+ cations was optimized by addition of 18-crown-6 to the eluent. The best separation of 6 metal cations commonly present in various environmental samples was accomplished in less than 30 min using a 1.75 mM pyridine-2,6-dicarboxylic acid and 3 mM 18-crown-6 eluent with excellent repeatability (below 2%) and detection limits in the low micromolar range. The analysis of field samples is demonstrated; the concentrations of common inorganic cations in river water, mineral water and snow samples were determined.  相似文献   

2.
A hybrid monolithic column with sulfonate functionality was successfully prepared for the simultaneous separation of common inorganic cations in ion‐exchange chromatographic mode through a simple and easy single‐step preparation method. The strong cation‐exchange moieties were provided directly from allylsulfonate, which worked as an organic monomer in the single‐step reaction. Inorganic cations (Li+, Na+, K+, NH4+, Cs+, Rb+, Mg2+, Ca2+, and Sr2+) were separated satisfactorily by using CuSO4 as the eluent with indirect UV detection. The allysulfonate hybrid monolith showed a better performance in terms of speed and pressure drop than the capillary packed column. The number of theoretical plates achieved was 19 017 plates/m (in the case of NH4+ as the analyte). The relative standard deviations (n = 6) of both retention time and peak height were less than 1.96% for all the analyte cations. The allysulfonate hybrid monolithic column was successfully applied for the rapid and simultaneous separation of inorganic cations in groundwater and the effluent of onsite domestic wastewater treatment system.  相似文献   

3.
Pipes are the primary structural elements used for transporting fluid in various industries. The most common damage mechanism is corrosion, which occurs in pipes surface of turbine. The corrosive compounds for pipes are inorganic ion (Na+, Cl?, NH4+, NO3?, etc.) and grinding oil. For rapid and quantitative detection of inorganic ions on site, more reliable and reproducible analytical methods are demanded. A highly efficient solid–liquid sampling collection system is introduced in this work. Papering on the sample surface, inorganic cations and anions were simultaneously collected and analyzed by capillary electrophoresis with indirect ultraviolet detection. As a result, five cations (Na+, K+, NH4+, Ca2+, Mg2+) and three anions (Cl?, NO3?, SO42?) were completely separated. The efficiency of the sampling and ability of capillary electrophoresis analysis were presented by the determination of trace‐level (mg/m2) contaminants. The recoveries of cations and anions on the paper from metal surface were between 86.6 and 107.2%, and the relative standard deviations were less than 12.85%.  相似文献   

4.
An ion chromatography method is described for the simultaneous determination of anions (Cl, NO3, and SO42–) and cations (Na+, NH4+, K+, Mg2+, and Ca2+) using a single pump, a single eluent and a single detector. An anion-exchange column modified with chondroitin sulfate C facilitated the elution of the above three anions using 5 mM tartaric acid as the eluent in isocratic mode, whereas the same eluent facilitated the separation of the above five cations on a commercially-available cation-exchange column. The separation columns were connected in series via two six-port switching valves, so the required cation-exchange or anion-exchange separation could be carried out by selecting the appropriate positions for the switching valves. The separations were completed in 30 min.  相似文献   

5.
Capillary ion electrophoresis–capacitively coupled contactless conductivity detection (CIE-C4D) with a polyvinyl alcohol chemically coated capillary (PVA capillary) was used to analyze inorganic cations (Na+, K+, NH4+, Mg2+, and Ca2+) commonly found in human saliva. The PVA capillary, which was made by our laboratory, minimized electro-osmotic flow in the wide pH range of the background electrolyte (BGE), and the PVA layer adsorbed to capillary wall did not affect the conductimetric background level. In this study, we determined an optimized BGE of 30 mM lactic acid/histidine plus 3 mM 18-crown-6 for the CIE-C4D system using the PVA capillary, which could simultaneously improve the separation of Mg2+ and Ca2+ from Na+ and that of K+ from NH4+. This system obtained highly reproducible separation of cations in human saliva samples within 8 min at 20 kV without deprotonation. The quantifiability of cations in human saliva samples on the CIE-C4D system was demonstrated through identification by ion chromatography with satisfactory results.  相似文献   

6.
This work reports an ion chromatographic (IC) method for the quantitative determination of inorganic cations (Na+, K+, Mg2+ and Ca2+) in biodiesel samples that were synthesized from different vegetable oils and fat. The proposed method uses water extraction, heating and ultrasound. The limits of detection (LOD) for each ion, in milligrams of the analyte per kilogram of biodiesel (mg kg−1), were respectively: 0.11 (Na+); 0.42 (K+); 0.23 (Ca2+); and 0.36 (Mg2+). The accuracy of the method was studied through recovery tests. For comparison, two samples were also analyzed using an Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) procedure. The paired Student t test and the Snedecor F test showed that both methods offer equivalent results in terms of accuracy and precision. The operational simplicity, accuracy and precision of the proposed method suggest that it can be a good alternative for the determination of inorganic cations in biodiesel samples.  相似文献   

7.
Summary A pure silica gel (Pia Seed 5S-60-SIL), synthesized by the hydrolysis of pure tetraethoxysilane [Si(OCH2CH3)4], was applied as a cation-exchange stationary phase in ion chromatography with indirect photometric detection for common mono-and divalent cations (Li+, Na+, NH4 +, K+, Mg2+, and Ca2+) using various protonated aromatic monoamines (tyramine [4-(2-aminethyl) phenol], benzylamine, phenylethylamine, 2-methylpyridine and 2,6-dimethylpyridine) as eluet ions. When using 0.75 mM tyramine-0.25 mM oxalic acid-1.5 mM 18-crown-6 (1,4,7,10,13,16-hexaoxacyclooctadecane) at pH 5.0 as the eluent, excellent simultaneous separation and highly sensitive detection at 275 nm for these mono-and divalent cations were achieved on the Pia Seed 5S-60-SIL column (150×4.6 mm I.D.) in 20 min.  相似文献   

8.
A simple and rapid microwave-assisted extraction (MAE) technique has been developed for the determination of water-soluble inorganic species (cations: Na+, NH4+, K+, Ca2+ and Mg2+ and anions: F, Cl, NO3, PO43– and SO42–) in airborne particulate matter. The analytes were extracted under different treatment conditions such as microwave power and extraction time. They were quantified using ion chromatography. The observed concentrations and recovery yields obtained under different conditions were compared. The results of a comparison between this MAE and sonication using NIST SRM 1648 are also given in this paper. The optimized MAE technique gave results in good agreement with the values obtained by the sonication. For some ions, for example Mg2+ and K+, recovery was low with both techniques. The results demonstrated that the optimized MAE is fast and efficient compared with conventional ultrasonic extraction. Urban airborne particles were collected and subjected to the MAE followed by the IC analysis to determine the relative proportions of different water-soluble inorganic species. These results are briefly discussed.  相似文献   

9.
A capillary electrophoretic (CE) method has been optimized for the separation of some common alkali and alkaline-earth metal cations in anti-asthmatic homeopathic liquid pharmaceutical preparations. Separation was carried out on a 74 cm (62.5 cm to the detector) × 75 μm ID fused silica capillary at a potential of 25 kV and 25 °C. Baseline separation of NH4 +, K+, Ca2+, Na+, Mg2+ and Li+ was achieved in less than 4.5 min. The proposed method was applied for the determination of the above-mentioned ions in homeopathic liquid formulations. Limits of quantitation (LOQ) observed were 1.5 ppm for NH4 +, Ca2+ and Mg2+ 0.8 ppm for Na+, 1.6 ppm for K+, and 0.4 ppm for Li+. During electrophoresis, the ingredients used in the preparation of homeopathic formulation did not interfere with the cations examined.  相似文献   

10.
A method was developed for the quantitative determination of cations and anions in Antarctic ice cores at μg L−1 and sub-μg L−1 levels by ion chromatography (IC), after ultra-clean decontamination procedures. Strict manipulation and decontamination procedures were used in sub-sampling, in order to minimise sample contamination. Na+, NH4+, K+, Mg2+ and Ca2+ were determined by 12-min isocratic elution (H2SO4 eluent). Contemporaneously, in a parallel device, F, MSA (methanesulfonic acid), Cl, NO3 and SO42− were analysed in a single 12-min run with multiple-step elution using Na2CO3/NaHCO3 as eluent. Melted ice samples were pumped from their still-closed containers (polystyrene accuvettes with polyethylene caps), shared between the two ion chromatographic systems, online filtered (0.45 μm Teflon membrane) and pre-concentrated (anions and cations pre-concentration columns) using a flow analysis system, thus avoiding uptake of contaminants from the laboratory atmosphere. Sensitivity, linear range, reproducibility and detection limit were evaluated for each chemical species. Anion or cation detection limits ranged from 0.01 to 0.15 μg L−1 by using a relatively small sample volume (1.5 mL). Such values are significantly lower than those reported in literature for almost all the components. These methods were successfully applied to the analysis of cations and anions at trace levels in the Dome C ice core. The composition of the atmospheric aerosol for the last 850 kyr was reconstructed by high-resolution continuous chemical stratigraphies. Concentration trends in the last nine glacial-interglacial climatic cycles were shown and briefly discussed.  相似文献   

11.
A fast automated system for rapid electrophoretic separations in short conventional capillaries employing contactless conductivity detection is presented. The instrument is based on pneumatic pressurization and does not require a conventional pump. The required pressures and flow rates for the different steps of the injection and flushing processes are produced with the help of two flow restrictors. The device is implemented on a microfluidic breadboard with dimensions of ca. 13 × 20 cm and employs miniature valves. Nine inorganic cations, namely NH4+, K+, Na+, Ca2+, Mg2+, Mn2+, Sr2+, Li+, and Ba2+, could be separated in a capillary of 10 μm inner diameter and 6 cm effective length within 25 s. Following a reduction of the effective length to 4 cm, still five inorganic cations could be separated in a time span of 12 s. The repeatability of peak areas was better than 3.1 % and limits of detection between 3.5 and 5.5 μM were achieved.  相似文献   

12.
Summary A monolithic ODS-silica gel column modified by saturating it with lithium dodecylsulfate (Li-DS) was firstly used to separate monovalent cations simultaneously including H+, Na+, NH4 + and K+ by ion-chromatography (IC). Using an acidified 60 mM LiCl solution (pH 3.95, containing 0.10 mM Li-DS) as eluent, these monovalent cations were separated well in the order of Na+<NH4 +<K+<H+ within 3 min at a flow rate of 2.0 mL min−1. The detection limits of these cations by this method with conductivity detection were 20.0 μM for Na+, 12.0 μM for NH4 +, 9.84 μM for K+ and 6.20 μM for H+. Acid rain water samples with a pH value less than 5.00 could be analyzed directly with this IC system.  相似文献   

13.
Affinity capillary electrophoresis (ACE) and pressure‐assisted ACE were employed to study the noncovalent molecular interactions of antamanide (AA), cyclic decapeptide from the deadly poisonous fungus Amanita phalloides, with univalent (Li+, Na+, K+, and NH4+) and divalent (Mg2+ and Ca2+) cations in methanol. The strength of these interactions was quantified by the apparent stability constants of the appropriate AA‐cation complexes. The stability constants were calculated using the nonlinear regression analysis of the dependence of the effective electrophoretic mobility of AA on the concentration of the above ions in the BGE (methanolic solution of 20 mM chloroacetic acid, 10 mM Tris, pHMeOH 7.8, containing 0–50 mM concentrations of the above ions added in the form of chlorides). Prior to stability constant calculation, the AA effective mobilities measured at actual temperature inside the capillary and at variable ionic strength of the BGEs were corrected to the values corresponding to the reference temperature of 25°C and to the constant ionic strength of 10 mM. From the above ions, sodium cation interacted with AA moderately strong with the stability constant 362 ± 16 L/mol. K+, Mg2+, and Ca2+ cations formed with AA weak complexes with stability constants in the range 37–31 L/mol decreasing in the order K+ > Ca2+ > Mg2+. No interactions were observed between AA and small Li+ and large NH4+ cations.  相似文献   

14.
Muhammad Amin 《Talanta》2007,71(4):1470-1475
A convenient ion chromatography method has been proposed for the routine and simple determination of anions (Cl, SO42− and NO3) and/or cations (Na+, NH4+, K+, Mg2+ and Ca2+) using a single pump, a single eluent and a single detector. The present system used cation-exchange and anion-exchange columns connected in series via two 6-port switching valves or a single 10-port valve. The connection order of the ion-exchange columns could be varied by switching the valve(s). The present system therefore allowed the separation of either cations or anions in a single chromatographic run. While one ion-exchange column is being operated, the other ion-exchange column is being conditioned, i.e., the columns are always ready for analysis at any time. When 2.4 mM 5-sulfosalicylic acid was used as the eluent, the three anions and the five cations could be separated on the anion-exchange column and cation-exchange column, respectively. In order to obtain the separations of the target ions, the injection valve was placed between the two columns. Complete separations of the above anions or cations were demonstrated within 10 min each. The detection limits at S/N = 3 were 19-50 ppb (μg/l) for cations and 10-14 ppb for anions. The relative standard deviations of the analyte ions were less than 1.1, 2.9 and 2.8% for retention time, peak area and peak height, respectively. This proposed technique was applied to the determination of common anions and cations in river water samples.  相似文献   

15.
The retention properties of a SBA-15 mesoporous silica functionalized with –(CH2)3COOH groups, synthesized by a co-condensation route, were investigated for the ion chromatography of different cationic species. A systematic study on the effect of different eluent compositions containing non-complexing (methanesulfonic acid) or complexing (oxalic or pyridine-2,6-dicarboxylic acids) eluents, in the presence of organic modifiers (CH3CN, CH3OH, CH3NH2) on the retention of cations (Li+, Na+, K+, Ca2+, Mg2+, Sr2+, Ba2+, NH4+, Cu2+, Ni2+, Zn2+, Cd2+, Co2+, Pb2+, Fe3+) chosen as model analytes and for their environmental importance, allowed us to elucidate the mechanisms (cation-exchange or complexation) involved in the retention on the SBA-15 phase. For the first time separations of cations on SBA-15 based stationary phases are investigated, providing the basis for further development of mesoporous silica chemistry for in-flow ion-exchange applications.  相似文献   

16.
We have studied experimentally and theoretically the exchange of NH4 +, Na+, K+, Ca++, Mg++, and H+ ions in zeolite beds, weakly-acidic resin beds, and mixed beds of the zeolite and the resin. The zeolite is highly selective for NH4 + and K+, whereas the resin with carboxyl functional groups is highly selective for Ca++ and Mg++. The effluent histories of single exchanger beds can be well predicted by the Multicomponent Chromatography Theory developed by Helfferich and Klein (1970). These histories are mainly the result of ion competition for ion exchanger sites; they can not be adjusted to meet the goal that NH4 + ions are removed and simultaneously the pH and concentrations of all the major physiological cations are maintained at normal values. The effluent histories of mixed beds, on the other hand, can be adjusted. We have designed a mixed bed which can meet the goal except that for each equivalent of NH4 + removed, 0.3 equivalents of Na+ are returned. The effluent histories of K+ and NH4 + for the mixed beds are similar to those of the zeolite beds, whereas the Ca++ and Mg++ histories are similar to those of the resin beds.  相似文献   

17.
The possibility of applying sulfonated cation exchangers on the basis of hypercrosslinked polystyrene (HCPS) of different ion-exchange capacity for the ion-chromatographic separation of alkali metal and ammonium cations was demonstrated. The effect of the nature and concentration of the eluent, the temperature of the chromatographic column, additions of an organic solvent to the eluent, and the ion-exchange capacity of the sorbent on the retention of cations was examined. An unusual selectivity of the sorbent for lithium and ammonium cations was found; the elution order can change for the Li+/Na+ and Rb+/NH+ 4 pairs depending on the nature of the eluent, the temperature, additions of an organic solvent, and the structural characteristics of the sorbent. When dilute solutions of nitric acid are used as the eluent, the following elution order of cations was obtained: Na+ < Li+ < K+ < NH+ 4 < Rb+ < Cs+ Mg2+ < Sr2+ < Ca2+ < Ba2+. Under the optimum conditions of separation (1 mM solution of sulfuric acid, 20°C) on sulfonated HCPS with an ion-exchange capacity of 0.07 mequiv/g, the separation of ammonium and alkali metal cations was achieved within 17 min.  相似文献   

18.
The modification of silica gel with aluminium and zirconium can be used for the preparation of advanced silica-based cation-exchange stationary phases for use in ion chromatography with conductimetric detection (IC-CD) for cations. Silica gels modified with aluminium (Al-silica) and zirconium (Zr-silica) act as cation-exchangers under strongly acidic conditions. Highly sensitive indirect conductimetric detection and excellently simultaneous separation for common mono- and divalent cations (Li+, Na+, NH4+, K+, Mg2+ and Ca2+) can be achieved on the Al-silica and Zr-silica columns in IC-CD by using acidic eluents containing 15-crown-5 (1,3,7,10,13-pentaoxacyclopentadecane). The Al-silica and Zr-silica can also be applied successfully as cation-exchange stationary phases in ion-exclusion chromatography for the separation of various aliphatic and benzenecarboxylic acids.  相似文献   

19.
Summary Pure silica gel (Pia Seed 5S-60-SIL) has been investigated as a cation-exchange stationary phase for ion chromatography of common monovalent and divalent cations (Li+, Na+, NH4+, K+, Mg2+, and Ca2+) with conductimetric detection; dilute oxalic acid (0.05 mm oxalic acid, pH 4.1, to 1 mm oxalic acid, pH 3.0) was used as mobile phase. The Pia Seed 5S-60-SIL silica gel acted as a cation-exchange stationary phase for these cations when 0.2 mm oxalic acid at pH 3.6 was used as the mobile phase. Excellent simultaneous separation and highly sensitive indirect conductimetric detection of these cations were achieved in 20 min on a 150 mm × 4.6 mm i.d. Pia Seed 5S-60-SIL silica gel column with 0.2 mm oxalic acid containing 4 mm 18-crown-6 (1,4,7,10,13,16-hexaoxacycloctadecane), pH 3.7, as mobile phase (detection limits (signal-to-noise ratio, 3, injection volume, 20 L), were 0.15 m for Li+, 0.16 m for Na+, 0.21 m for NH4+, 1.0 m for K+, 0.17 m for Mg2+, and 0.25 m for Ca2+). The proposed IC–CD method was successfully applied to the separation and detection of major cations (Na+, NH4+, K+, Mg2+, and Ca2+) in rain and river water samples.  相似文献   

20.
An ion chromatographic (IC) method has been developed for determination of hydrogen ion (H+). It is based on the use of sulfonated cation-exchange resin as stationary phase, aqueous ethylenediamine-N,N,N′,N′-tetraacetic acid (dipotassium salt, EDTA-2K, written as K2H2Y) solution as mobile phase, and conductivity for detection. H+ was separated mainly by cation-exchange, but its elution was accelerated by the presence of EDTA. The order of elution for the model cations was H+ > Li+ > Na+ > NH4 + > Ca2+ > > Mg2+. A sharp and highly symmetrical peak was obtained for H+ and this was attributed to the capacity of H2Y2 2– to receive and bind H+. H+ was detected conductiometrically and detector response (reduction in conductivity as a result of H++H2Y2–→H3Y) was linearly proportional to the concentration of H+ in the sample. The detection limit for H+ with this IC system was better than 4.7 μmol L–1. A significant advantage of this method was the ability to separate and determine, in one step, H+ and other cations. The successful determination of H+ and other cation species in real acid-rain samples demonstrated the usefulness of this method.  相似文献   