首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 812 毫秒
1.
O W Lau  S F Luk  H L Huang 《The Analyst》1989,114(5):631-633
A simple and accurate spectrophotometric method is proposed for the determination of tannins in tea and beer samples based on the reduction of iron(III) to iron(II) by tannins at 80 degrees C for 20 min. The iron(II) was then reacted with 1,10-phenanthroline at pH 4.4 to form a coloured complex. Background correction could be effected by precipitating the tannins in the sample solution twice with gelatin and kaolin. Absorbance measurements were made at 540 nm and the calibration graph was linear from 0 to 5.5 micrograms ml-1 of tannic acid with a slope of 0.213 A p.p.m.-1. The precision for the determination of tannins in a tea sample containing 9.45% of tannins was 1.8%. Most of the ingredients commonly found in tea and beer samples do not interfere with the determination. Several tea and beer samples were analysed for their tannin content using the proposed method.  相似文献   

2.
Study was carried out to develop two simple, fast, accurate and sensitive spectrophotometric methods (A and B) for the determination of citalopram hydrobromide in commercial tablet formulations. In method A, UV spectrophotometer determined the contents of citalopram hydrobromide in tablets at 240 nm in methanol solvent. The linear range was 5-40 microg ml-1 with molar absorptivity 1.4x10(4) l mol-1 cm-1. While the method B based on the reaction of citalopram base as n-electron donor with 2,3-dichloro-5,6-dicyano-1,4-benzoquinone as pi-acceptors to give highly colored complex species that absorb maximally at 590 nm. Beer's law was obeyed in the concentration limit of 10-250 microg ml-1 with molar absorptivity 3.3x10(3) l mol-1 cm-1 for citalopram hydrobromide. The limits of detection and limit of quantification was calculated and found to be 5.2 microg ml-1 and 17.4 microg ml-1 respectively. The proposed methods were found to be rapid, accurate, precise and sensitive for the determination of citalopram hydrobromide in commercial tablet formulations with out interferences from common additives encountered.  相似文献   

3.
O W Lau  S F Luk  R K Lam 《The Analyst》1989,114(2):217-219
A simple, rapid and accurate spectrophotometric method has been developed for the determination of sorbic acid in various food samples based on the oxidation of sorbic acid by iron(III) at 100 degrees C to malonaldehyde, which then reacts with 2-thiobarbituric acid to form a reddish brown product. The optimum experimental conditions for colour development have been assessed. Absorbance measurements were made at 529 nm in the presence of 0.4% m/V citric acid. The calibration graph was linear for 0-6 micrograms ml-1 of sorbic acid with a slope of 0.131 A micrograms-1 ml. The recoveries of sorbic acid at concentrations of 164-557 micrograms ml-1 ranged from 96 to 103%. The relative standard deviations of ten replicate determinations of sorbic acid in a synthetic cream soda sample spiked with 573 micrograms ml-1 of sorbic acid and in an onion juice sample containing 82 micrograms ml-1 of sorbic acid were 1.6 and 1.9%, respectively. Interferences from several common food additives can be minimised by extracting sorbic acid with diethyl ether and then back-extracting the acid with sodium hydrogen carbonate. The method has been applied successfully to the determination of sorbic acid in a wide range of food samples including beverages, cake, cake mate, garlic bread sprinkle, onion juice, oyster flavoured sauce and grenadine syrup.  相似文献   

4.
An extraction--spectrophotometric method is described for the determination of oxalate, based on the formation of a mixed ligand vanadium (V)--mandelohydroxamic acid--oxalate complex. The complex was extracted into a solution of trioctylmethylammonium chloride (Adogen 446) in toluene and the absorbance measured at 535 nm. The experimental variables and interferences in this determination were studied. The detection limit is 0.5 microgram ml-1 and the range of application is between 2 and 8 micrograms ml-1. The method was applied to the determination of oxalate in urine and blood serum.  相似文献   

5.
A new method for the determination of taurine was developed based on indirect amperometric detection after capillary electrophoresis. A serial dual‐electrode detector comprising an on column Pt film electrode (upstream electrode) and an end column Pt microdisk electrode (downstream electrode) was utilized to conduct the indirect amperometric detection. Bromide is oxidized to bromine at upstream electrode and reduced back to bromide at downstream electrode. Since taurine can react with bromine quantitatively and rapidly, its concentration can therefore be determined by the decrease of the current for bromine reduction at the downstream electrode. Principal experimental parameters governing the analytical performance were investigated and optimized. Under the optimal conditions, taurine can be baseline separated from interfering amino acids and the detection limit of 0.18 μM was obtained with a linear correlation coefficient of 0.999 over the concentration range of 0.5–60 μM. The developed method has been successfully applied in the determination of taurine in human tear fluid. The taurine level obtained was in good agreement with previous reports and recoveries for taurine spiked ranged from 92–95% with relative standard deviations within 4.6%, demonstrating the reliability of the developed method in the determination of taurine in human tear fluid.  相似文献   

6.
The characteristics of host-guest complexation between p-sulfonated calix[4]arene (SC4A) and lomefloxacin (LMFX) were investigated by fluorescence spectrometry. A 1:1 stoichiometry for the complexation was established and an association constant of 6.48x10(4) l mol-1 at 25 degrees C was calculated by applying a deduced equation. The interaction mechanism of the inclusion complex was discussed and the various factors affecting the inclusion process were examined in detail. It was found that an appropriate amount of cationic surfactant cetyltrimethylammonium bromide (CTAB) can remarkably enhance the fluorescence intensity of the supramolecular complex system. Based on the obtained results, a novel sensitive spectrofluorimetric method for the determination of lomefloxacin based on supramolecular complex was developed with a linear range of 0.01-3.0 microg ml-1 and a detection limit of 0.008 microg ml-1, for the first time. The method was applied for the determination of lomefloxacin in pharmaceutical preparations successfully.  相似文献   

7.
A new method for the quantitative determination of taurine in beverages by microchip electrophoresis was developed. A rapid and simple sample preparation procedure, only including two dilution steps and the addition of the fluorogenic labeling reagent NBD-Cl (4-chloro-7-nitrobenzofurazan), is applied. Using a home-built wavelength-resolved fluorescence detector, the separation and determination of the taurine derivative could be achieved in only 12 s, while the additional spectral information was utilized to ensure peak purity. Spanning from 0.1 to 50 mmol L(-1), the linear dynamic range of the applied method was adapted to the apparent contents in common taurine containing beverages. The smallest detectable amount of the taurine derivative actually injected into the separation channel was as low as 60 amol. The method was successfully validated by an independent liquid chromatographic method.  相似文献   

8.
Zhan XQ  Li DH  Zhu QZ  Zheng H  Xu JG 《The Analyst》2000,125(12):2330-2334
A novel and sensitive fluorimetric method was developed for the determination of formaldehyde based on the co-quenching effect of formaldehyde and sulfite on the fluorescence of tetra-substituted amino aluminium phthalocyanine. Formaldehyde in the concentration range 0.040-1.19 micrograms ml-1 can be determined with a limit of detection of 7.5 ng ml-1. The relative standard deviation for nine replicate measurements of 80.0 ng ml-1 formaldehyde is 1.8%. The method was applied to the analysis of real samples with satisfactory results.  相似文献   

9.
A sensitive spectrofluorimetric procedure for the determination of paroxetine-HCl in pharmaceutical formulations and human plasma has been described. The native fluorescence of the drug has been studied under different conditions. Maximum fluorescence intensity was obtained in methanol at 340 nm using 290 nm for excitation. Different surfactants showed negative effect on the fluorescence intensity of paroxetine-HCl. Regression analysis of Beer's plot showed good correlation (r=0.9999) between fluorescence intensity and concentration over the range of 0.05-0.40 microg ml-1 with lower limit of detection (LOD) of 0.015 microg ml-1. The drug was successfully determined in its tablets with average % recovery of 98.00+/-0.99% which was in accordance with those given by a compendial method. The method was also applied to the determination of paroxetine-HCl in spiked human plasma with average recovery of 77.70+/-1.06%.  相似文献   

10.
A novel flow injection method with resonance light scattering detection was developed for the determination of total protein concentrations. This method is based on the enhancement of RLS signals from Methyl Blue (MB) by protein. The enhanced RLS intensities at 333 nm, in a pH 4.1 acidic aqueous solution, were proportional to the protein concentration over the range 2.0-37.3 and 1.0-36.0 microg ml-1 for human serum albumin (HSA) and bovine serum albumin (BSA), respectively. The corresponding limits of detection (3sigma) of 45 ng ml-1 for HSA and 80 ng ml-1 for BSA were attained. The method was successfully applied to the quantification of total proteins in human serum samples, the maximum relative error is less than 1% and the recovery is between 98% and 102%. The sample throughput was 60 h-1.  相似文献   

11.
C W Fu  W D Mason 《The Analyst》1989,114(10):1219-1223
A high-performance liquid chromatographic method was developed to determine the levels of propranolol and its major metabolite, 4-hydroxypropranolol, in human plasma. The limits of determination are 10 ng ml-1 of propranolol and 5 ng ml-1 of 4-hydroxypropranolol using a 0.5-ml plasma sample. The stability of plasma samples stored at -30 degrees C for up to 2 months was also tested. No stabilising antioxidants were added to the samples.  相似文献   

12.
Simultaneous analysis of homotaurine and its homologous, taurine, is a highly challenging issue, especially in matrices they exist simultaneously. A simple precolumn derivatization procedure combined with high-performance liquid chromatography–fluorescence detection was developed for simultaneous determination of homotaurine and taurine in marine macro-algae. The analytes were derivated with o-phthalaldehyde at an ambient temperature and alkaline medium. Calibration curves were linear in the ranges of 50–2500 µg L?1 for homotaurine and 100–2500 µg L?1 for taurine with the coefficients of determination higher than 0.998. Limits of detection of homotaurine and taurine were 15 and 30 µg L?1, respectively. Intraday (n = 6) and inter-day (n = 4) precisions of the method were satisfactory with relative standard deviations less than 6.0%. Good recoveries (>94%) were acquired by the method for extraction of homotaurine and taurine from algae matrices. Liquid chromatography–mass spectrometry was also used to confirm detection of the analytes in algae samples. The data suggest that the method was successfully applied to simultaneous determination of homotaurine and taurine in algae samples.  相似文献   

13.
S Chattaraj  A K Das 《The Analyst》1992,117(3):413-416
An indirect method for the determination of sulfate by atomic absorption spectrometry (AAS) is described. Sulfate forms a stable ion-association complex, [Cu(neocuproine)2]2+(SO4(2-)), in neutral medium, which can be extracted into isobutyl methyl ketone in the presence of a polar medium (methanol) with an efficiency higher than 98.0% and the extract can be analysed directly for copper (and hence indirectly for sulfate) by AAS. Measurement of the copper atomic absorption signal from the organic phase allows the indirect determination of 0.14-1.12 micrograms ml-1 of sulfate, giving a 450-fold increase in sensitivity over the conventional method of precipitation with barium. The limit of detection (3 sigma) is 3.2 ng ml-1 which is better than that of ion chromatography (0.15 micrograms ml-1). Indirect AAS allows the accurate assay of inorganic sulfate anion in biological fluids and tissues. The sulfate concentration determined by the proposed method in human blood serum (n = 6 in each instance) was 35.4-43.3 micrograms ml-1 in normal persons, 50.3-62.5 micrograms ml-1 in jaundice patients and 83.3-155.6 micrograms ml-1 in diabetic patients. A good correlation between measured sulfate and the sulfate added to blood serum was obtained.  相似文献   

14.
Zhang W  Xu H  Wu S  Chen X  Hu Z 《The Analyst》2001,126(4):513-517
For the first time, Crystal Violet (CV) was used to determine nucleic acid concentrations using the resonance light-scattering (RLS) technique. Based on the enhancement of the RLS of CV by nucleic acids, a new quantitative determination method for nucleic acids in aqueous solutions has been developed. At pH 5.03 and ionic strength 0.005 mol kg-1, the interaction of CV with nucleic acids results in three characteristic RLS peaks at 344.0, 483.0 and 666.0 nm. With 4.0 x 10(-5) mol l-1 of CV, linear relationships were found between the enhanced intensity of RLS at 666.0 nm and the concentration of nucleic acids in the range 0-2.5 micrograms ml-1 for herring sperm DNA, 0-4.0 micrograms ml-1 for calf thymus DNA and 0-4.5 micrograms ml-1 for yeast RNA. The limits of determination were 13.8 ng ml-1 for herring sperm DNA, 36.8 ng ml-1 for calf thymus DNA and 69.0 ng ml-1 for yeast RNA. The assay is convenient, rapid, inexpensive and simple.  相似文献   

15.
M Luque  A Ríos  M Valcárcel 《The Analyst》1998,123(11):2383-2387
Two methodologies are described for the determination of paraquat and diquat. The first is based on the pre-treatment of an electrode with a surfactant solution, which improves the electrochemical determination of the herbicides. Linear calibration graphs were obtained in the ranges 10-80 and 10-100 ng ml-1 for paraquat and diquat, respectively. The limits of detection were 6.32 for paraquat and 4.80 ng ml-1 for diquat. The method was applied to the determination of the herbicides in synthetic water samples. The second methodology is based on the preconcentration of paraquat and diquat in a minicolumn packed with a cation-exchange material. The determination ranges and detection limits depend on the sample volume used (5-50 ml). Thus, 50 ml of sample provides limits of detection of 0.016 and 0.020 ng ml-1 for paraquat and diquat, respectively. The applicability of the method was demonstrated with the determination of the herbicides in both synthetic and real water samples.  相似文献   

16.
A new simple, accurate and precise spectrophotometric method for the determination of six phenothiazine drugs in pure form and in dosage forms is described. The method is based on the oxidation of the studied drugs by a known excess of Chloramine-T in hydrochloric acid medium and subsequent determination of the unreacted oxidant by reacting it with indigocarmine in the same acid medium. The reacted oxidant corresponds to the drug content. The colored species exhibits maximum absorption at 610 nm. The apparent molar absorptivity values and Sandell sensitivity values are in the range 1.53 x 10(4)-2.96 x 10(4) l mol-1 cm-1 and 13.75-37.15 ng cm-2, respectively. The method is highly sensitive and suitable for 1-15 micrograms ml-1 concentrations with the detection limits being in the range, 0.0651-0.1724 microgram ml-1. The method was successfully applied to the studied drugs in their dosage forms. The results are reproducible within +/- 1% and compare favorably with those obtained by the procedures of the British Pharmacopeia.  相似文献   

17.
A spectrofluorimetric method has been developed for the sensitive and selective determination of 5-hydroxyindoles; the method is based on the reaction of 5-hydroxyindoles in a weakly alkaline solution (pH 9.0) with aromatic methylamines in the presence of potassium hexacyanoferrate(III) and dimethyl sulphoxide; the compounds produced fluoresce intensely in an alkaline solution (pH 11-12). Of the eight aromatic methylamines tested, benzylamine and 3,4-dimethoxybenzylamine were found to be the most favourable fluorogenic reagents in terms of sensitivity and reactivity. The methods with benzylamine and 3,4-dimethoxybenzylamine permit the determination of 5-hydroxyindoles at concentrations as low as 22-72 pmol ml-1 and 1.0-2.4 nmol ml-1, respectively.  相似文献   

18.
A second-derivative synchronous scanning spectrofluorimetric method for the simultaneous determination of acetylsalicylic acid (ASA) and salicylic acid (SA) is described. The method is based on the native fluorescence of both acids in a 1% acetic acid-chloroform solution. Both ASA and SA can be determined within the concentration ranges 0.2-70 and 0.03-10 micrograms ml-1, respectively. The effect of each acid on the signal of the other has been studied in detail. Empirical equations have been used to overcome this effect, thus allowing the accurate determination of both acids in binary mixtures, without a separation step. The method has been applied to the determination of ASA and SA in blood serum and to the determination of SA impurities in aspirin formulations. Recoveries from sera spiked with both ASA (2.5-50 micrograms ml-1) and SA (100-160 micrograms ml-1) varied from 99.5 to 106.7% (mean = 102.6%) and from 93.0 to 98.0% (mean = 95.8%), respectively. Recoveries of SA from spiked aspirin solutions (0.25-1.5 mg g-1 of aspirin) varied from 98.0 to 102.0% (mean = 100.3%).  相似文献   

19.
A new diazotizing reagent for the spectrophotometric determination of nitrite is described. The method is based on diazotization-coupling reaction between dapsone and phloroglucinol in hydrochloric acid medium. The reactions were conducted at room temperature, the molor absorptivity at 425 nm is 4.28 x 10(4) l mol-1cm-1 and was stable for 50 h. Beer's law was obeyed in the nitrite range of 0.008-1.0 microgram ml-1. Tolerance limits were tested for 33 species. The method has been found to be applicable for the determination of nitrite in natural and wastewater.  相似文献   

20.
A novel high-performance liquid chromatography (HPLC) method is presented for the detection and trace level determination of the tripeptide delta-L-alpha-aminoadipyl-L-cysteinyl-D-valine (ACV). The tripeptide, an intermediate in penicillin production, is derived from fungal fermentation. The technique relies on ion-exchange separation of the tripeptide on an anion-exchange column followed by detection by reduction on a gold electrode using pulsed amperometry. The sensitivity of direct determination of ACV is increased by employing pulsed amperometric detection (PAD) over direct ultraviolet detection. Choice of the working electrode and optimisation of electrode potentials was based on cyclic voltammograms recorded for the tripeptide in the mobile phase. A linear regression equation was obtained over the range 0-100 micrograms ml-1. The detection limit in fermentation broths was found to be 0.1 micrograms ml-1 whereas in buffer the detection limit was found to be 10 ng ml-1. A good correlation coefficient was observed when ACV concentrations determined by ion chromatography-PAD were compared with measurements obtained by pre-column derivatisation with fluoromethylorthochloroformate followed by HPLC separation on a reversed-phase C18 silica column with UV detection. The procedure has been applied to the measurement of natural levels of ACV in fermentation broths of selected strains of Aspergillus nidulans and Penicillin chrysogenum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏