首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes (MWCNTs)/Nafion was developed and applied for the extraction of polar aromatic compounds (PACs) in natural water samples. The characteristics and the application of this fiber were investigated. Electron microscope photographs indicated that the MWCNTs/Nafion coating with average thickness of 12.5 μm was homogeneous and porous. The MWCNTs/Nafion coated fiber exhibited higher extraction efficiency towards polar aromatic compounds compared to an 85 μm commercial PA fiber. SPME experimental conditions, such as fiber coating, extraction time, stirring rate, desorption temperature and desorption time, were optimized in order to improve the extraction efficiency. The calibration curves were linear from 0.01 to 10 μg mL−1 for five PACs studied except p-nitroaniline (from 0.005 to 10 μg mL−1) and m-cresol (from 0.001 to 10 μg mL−1), and detection limits were within the range of 0.03–0.57 ng mL−1. Single fiber and fiber-to-fiber reproducibility were less than 7.5 (n = 7) and 10.0% (n = 5), respectively. The recovery of the PACs spiked in natural water samples at 1 μg mL−1 ranged from 83.3 to 106.0%.  相似文献   

2.
In this paper, we proposed an approach using a multi-walled carbon nanotubes (MWCNTs)/Nafion composite coating as a working electrode for the electrochemically enhanced solid-phase microextraction (EE-SPME) of charged compounds. Suitable negative and positive potentials were applied to enhance the extraction of cationic (protonated amines) and anionic compounds (deprotonated carboxylic acids) in aqueous solutions, respectively. Compared to the direct SPME mode (DI-SPME) (without applying potential), the EE-SPME presented more effective and selective extraction of charged analytes primarily via electrophoresis and complementary charge interaction. The experimental parameters relating to extraction efficiency of the EE-SPME such as applied potentials, extraction time, ionic strength, sample pH were studied and optimized. The linear dynamic range of developed EE-SPME-GC for the selected amines spanned three orders of magnitude (0.005–1 μg mL−1) with R2 larger than 0.9933, and the limits of detection were in the range of 0.048–0.070 ng mL−1. All of these characteristics demonstrate that the proposed MWCNTs/Nafion EE-SPME is an efficient, flexible and versatile sampling and extraction tool which is ideally suited for use with chromatographic methods.  相似文献   

3.
A novel multiwalled carbon nanotubes–polyaniline composite (MWCNTs–PANI) film coated platinum wire was fabricated through electrochemical deposition. The coating was characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectrophotometry and thermogravimetry. It was found that the coating was porous and had large specific area and adsorption capacity; in the composite MWCNTs and polyaniline interacted with each other and the film kept stable up to 320 °C. The as-made fiber was used for the headspace solid-phase microextraction (HS-SPME) of some phenolic compounds (i.e. 2-chlorophenol, 2,4-dichlorophenol, 2-methylphenol, 3-methylphenol, 2,6-dimethylphenol, 2-nitrophenol), followed by gas chromatographic analysis. The MWCNTs–PANI coating showed better analytical performance than PANI. Under the optimized conditions, the detection limits were 1.89–65.9 ng L−1, the relative standard deviations (RSDs) were 2.7–6.5% for six successive measurements with single fiber, the RSDs for fiber-to-fiber were 5.2–12.4%, the linear ranges exceeded two magnitudes with correlation coefficient above 0.992. The fiber could be used for more than 250 times without decrease of efficiency. The proposed method was successfully applied to the extraction and determination of phenolic compounds in water sample, and the recoveries were 87.7–111.5% for different analytes. In addition, the fiber also presented advantages of easy preparation and low cost. Therefore, it is a promising SPME fiber.  相似文献   

4.
A novel solid-phase microextraction (SPME) Pt fiber coated with single-walled carbon nanotubes (SWCNTs) was prepared by electrophoretic deposition (EPD) and applied to the determination of phenols in aqueous samples by direct immersion (DI)-SPME-HPLC-UV. The results revealed that EPD was a simple and reproducible technique for the preparation of SPME fibers coated with SWCNTs without the use of adhesive. The obtained SWCNT coating did not swell in organic solvents nor strip off from substrate, and possessed high mechanical strength due to the strong Van der Waals attractions between the surfaces of the SWCNTs. The prepared SPME fiber was conductive since both SWCNT coating and Pt wire were conductive. Using Pt wire as substrate, the fiber was unbreakable. Owing to the presence of oxygenated groups on SWCNTs and the high surface area of SWCNTs, the SWCNT fiber was similar to or superior to commercial PA fiber in extracting the studied phenols from aqueous sample. A durability of more than 80 analyses was achieved for one unique fiber. Under optimized conditions, the detection limits for the phenols varied between 0.9 and 3.8 ng/mL, the precisions were in the range of 0.7–3.2% (n = 3), and linear ranges were within 10 and 300 ng/mL. The method was successfully applied to the analysis of spiked seawater and tap water samples with the recoveries from 87.5 to 102.0%.  相似文献   

5.
A novel liquid–liquid–solid microextraction (LLSME) technique based on porous membrane-protected molecularly imprinted polymer (MIP)-coated silica fiber has been developed. In this technique, a MIP-coated silica fiber was protected with a length of porous polypropylene hollow fiber membrane which was filled with water-immiscible organic phase. Subsequently the whole device was immersed into aqueous sample for extraction. The LLSME technique was a three-phase microextraction approach. The target analytes were firstly extracted from the aqueous sample through a few microliters of organic phase residing in the pores and lumen of the membrane, and were then finally extracted onto the MIP fiber. A terbutylazine MIP-coated silica fiber was adopted as an example to demonstrate the feasibility of the novel LLSME method. The extraction parameters such as the organic solvent, extraction and desorption time were investigated. Comparison of the LLSME technique was made with molecularly imprinted polymer based solid-phase microextraction (MIP-SPME) and hollow fiber membrane-based liquid-phase microextraction (HF-LPME), respectively. The LLSME, integrating the advantages of high selectivity of MIP-SPME and enrichment and sample cleanup capability of the HF-LPME into a single device, is a promising sample preparation method for complex samples. Moreover, the new technique overcomes the problem of disturbance from water when the MIP-SPME fiber was exposed directly to aqueous samples. Applications to analysis of triazine herbicides in sludge water, watermelon, milk and urine samples were evaluated to access the real sample application of the LLSME method by coupling with high-performance liquid chromatography (HPLC). Low limits of detection (0.006–0.02 μg L−1), satisfactory recoveries and good repeatability for real sample (RSD 1.2–9.6%, n = 5) were obtained. The method was demonstrated to be a fast, selective and sensitive pretreatment method for trace analysis of triazines in complex aqueous samples.  相似文献   

6.
A solid-phase microextraction (SPME) fiber coated with single walled carbon nanotubes (SWCNTs) was prepared by electrophoretic deposition and treated at 500 °C in H2 stream. In order to evaluate the characteristics of the obtained fiber, it was applied in the headspace solid-phase microextraction (HS-SPME) of benzene, toluene, ethylbenzene and xylenes (BTEX) from water sample and quantification by gas chromatography with flame ionization detection (GC-FID). The results indicated that the thermal treatment with H2 enhanced the extraction of the SWCNTs fiber for BTEX significantly. Thermal stability and durability of the fiber were also investigated, showing excellent stability up to 350 °C and life time over 120 times. In the comparison with the commercial CAR–PDMS fiber, the SWCNTs fiber showed similar and higher extraction efficiencies for BTEX. Under the optimized conditions, the linearity, LODs (S/N = 3) and LOQs (S/N = 10) of the method based on the SWCNTs fiber were 0.5–50.0, 0.005–0.026 and 0.017–0.088 μg/L, respectively. Repeatability for one fiber (n = 3) was in the range of 1.5–5.6% and fiber-to-fiber reproducibility (n = 3) was in the range of 4.2–8.3%. The proposed method was successfully applied in the analysis of BTEX compounds in seawater, tap water and wastewater from a paint plant.  相似文献   

7.
Chen L  Chen W  Ma C  Du D  Chen X 《Talanta》2011,84(1):104-108
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes/polypyrrole (MWCNTs/Ppy) was prepared with an electrochemical method and used for the extraction of pyrethroids in natural water samples. The results showed that the MWCNTs/Ppy coated fiber had high organic stability, and remarkable acid and alkali resistance. In addition, the MWCNTs/Ppy coated fiber was more effective and superior to commercial PDMS and PDMS/DVD fibers in extracting pyrethroids in natural water samples. Under optimized conditions, the calibration curves were found to be linear from 0.001 to 10 μg mL−1 for five of the six pyrethroids studied, the exception being fenvalerate (which was from 0.005 to 10 μg mL−1), and detection limits were within the range 0.12-0.43 ng mL−1. The recoveries of the pyrethroids spiked in water samples at 10 ng mL−1 ranged from 83 to 112%.  相似文献   

8.
A novel solid-phase microextraction (SPME) fiber was prepared by polymerization of an organic–inorganic hybrid polymeric coating on an anodized and derived Ti wire, and applied for the analysis of polycyclic aromatic hydrocarbons from environmental samples followed by high performance liquid chromatography (HPLC) analysis. A polyhedral oligomeric silsesquioxane (POSS) reagent containing methacryl substituent groups was used as an organic–inorganic hybrid cross-linker, and copolymerized with methyl methacrylate (MMA) to fabricate the hybrid coating via thermally initiated free radical polymerization in a glass capillary mold. The prepared fiber can be easily withdrawn from the glass capillary mold by controlling the polymerization conditions, especially polymerization solvent. A homogeneous and porous coating with thickness of about 100 μm was achieved using ethanol as polymerization solvent at the mass ratio of MMA to POSS as 1:0.5. High chemical and mechanical stability, as well as excellent durability for more than 100 times extractions with almost undiminished extraction efficiency were achieved due to the chemical immobilization and crosslinked hybrid coating. The proposed fiber showed much better extraction performance than the 100 μm commercial polydimethylsiloxane fiber for extracting PAHs from aqueous sample. The developed SPME-HPLC method for the determination of PAHs using the MMA–POSS hybrid coating achieved good linearity with good correlation coefficients (R = 0.991–0.999) and low detection limits in the range of 0.006 to 0.05 ng mL−1 (S/N = 3). The proposed fiber was successfully applied to the extraction of PAHs from environmental water samples with recoveries of 82–104% for river water, 83–103% for pool water, and 79–98% for wastewater, respectively.  相似文献   

9.
An improved multiple co-polymerization technique was developed to prepare a novel molecularly imprinted polymer (MIP)-coated solid-phase microextraction (SPME) fiber with propranolol as template. Investigation was performed for the characteristics and application of the fibers. The MIP coating was highly crosslinked and porous with the average thickness of only 25.0 μm. Consequently, the adsorption and desorption of β-blockers within the MIP coating could be achieved quickly. The specific selectivity was discovered with the MIP-coated fibers to propranolol and its structural analogues such as atenolol, pindolol, and alprenolol. In contrast, only non-specific adsorption could be shown with the non-imprinted polymer (NIP)-coated fibers, and the extraction efficiencies of propranolol and pindolol with the MIP-coated fibers were higher markedly than that with the commercial SPME fibers. A MIP-coated SPME coupled with high-performance liquid chromatography (HPLC) method for propranolol and pindolol determination was developed under the optimized extraction conditions. Linear ranges for propranolol and pindolol were 20–1000 μg L−1 and detection limits were 3.8 and 6.9 μg L−1, respectively. Propranolol and pindolol in the spiked human urine and plasma samples, extracted with organic solvent firstly, could be simultaneous monitored with satisfactory recoveries through this method.  相似文献   

10.
王雪梅  杨静  赵佳丽  周政  杜新贞  卢小泉 《色谱》2022,40(10):910-920
建立高效、灵敏的农药分离、富集和检测方法具有重要意义。该实验采用一步法合成了钴基沸石咪唑骨架/多壁碳纳米管(ZIF-67/MWCNTs)复合物,并以该复合物为模板通过溶剂热法合成了钴镍笼状双金属氢氧化物/多壁碳纳米管(CoNi-LDH/MWCNTs)复合材料,将CoNi-LDH/MWCNTs用作固相微萃取(SPME)的纤维涂层富集环境水样中的6种农药,结合高效液相色谱(HPLC)测定了环境水样中的6种农药。通过扫描电镜、能谱分析、红外光谱、粉末X射线衍射和N吸附/脱附对所制备的各种材料进行了表征。利用正交设计试验优化SPME的萃取条件,包括萃取温度、萃取时间、搅拌速率、解吸时间和盐浓度。在最优化的条件下,该方法具有较宽的线性范围(百菌清为0.015~200μg/L,戊唑醇为0.140~200μg/L,毒死蜱为0.250~200μg/L,仲丁灵为0.077~200μg/L,溴氰菊酯为1.445~200μg/L,哒螨灵为0.964~200μg/L)、较低的检出限(0.004~0.434μg/L)和良好的重复性。单个纤维和不同批次纤维间的相对标准偏差(RSD)分别为0.5%~5.7%和0.5%~4.8%。在10.0μg/L和50.0μg/L 2个水平下的加标回收率为83.9%~108.2%,RSD<5.3%。此外,与其他涂层纤维相比,CoNi-LDH/MWCNTs涂层对农药具有更高效的富集能力,这归因于它的高比表面积以及CoNi-LDH/MWCNTs涂层与目标分析物之间存在的π-π堆积作用、疏水作用、阳离子-π相互作用和氢键作用。该方法可以实现环境水样中农药残留的高选择性、高灵敏度及高准确性的分析测定。  相似文献   

11.
Carbon nanotubes are a kind of new carbon-based nanomaterials, which have drawn great attention in many application fields. The potential of single-walled carbon nanotubes (SWCNTs) as solid-phase microextraction (SPME) adsorbent for the preconcentration of environmental pollutants has been investigated in recent years. In the present study, the feasibility of SWCNTs as SPME adsorbent for the determination of monobutyltin, dibutyltin and tributyltin in seawater samples was studied. To achieve this aim, the potential factors affecting the SPME efficiency, including extraction time, extraction temperature, desorption time, desorption temperature, and salinity were optimized. The developed method showed good performance according to the ICH (International Conference on Harmonization of Technical Requirements for Analytical Methods) criteria. The acquired calibration curves were linear (r ≥ 0.992) over the concentration range from ≤12 to 2000 ng L−1. For all of the analytes, the limit of detection at signal-to-noise ratio of 3 was below 5 ng L−1. Furthermore, in comparison with the commercial carboxen/polydimethylsiloxane fiber, the developed SWCNT fiber showed better thermal stability (over 350 °C) and longer life span (over 150 times). The application of the proposed method in environmental analyses was shown by analyzing seawater samples from the harbors on the Persian Gulf for butyltin residues. Some of the butyltins were detected in the analyzed samples. Results of the present study demonstrate the feasibility of the SWCNTs as SPME adsorbent for the determination of butyltins in seawater samples.  相似文献   

12.
In this work, a new solid-phase microextraction fiber was prepared based on nitrogen-doped graphene (N-doped G). Moreover, a new strategy was proposed to solve problems dealt in direct coating of N-doped G. For this purpose, first, Graphene oxide (GO) was coated on Pt wire by electrophoretic deposition method. Then, chemical reduction of coated GO to N-doped G was accomplished by hydrazine and NH3. The prepared fiber showed good mechanical and thermal stabilities. The obtained fiber was used in two different modes (conventional headspace solid-phase microextraction and cold-fiber headspace solid-phase microextraction (CF-HS-SPME)). Both modes were optimized and applied for the extraction of benzene and xylenes from different aqueous samples. All effective parameters including extraction time, salt content, stirring rate, and desorption time were optimized. The optimized CF-HS-SPME combined with GC-FID showed good limit of detections (LODs) (0.3–2.3 μg/L), limit of quantifications (LOQs) (1.0–7.0 μg/L) and linear ranges (1.0–5000 μg/L). The developed method was applied for the analysis of benzene and xylenes in rainwater and some wastewater samples.  相似文献   

13.
A novel carbon nanotube (CNT)-coated solid-phase microextraction fiber was prepared based on sol–gel technique. Commonly used fragile fused silica fiber was replaced with stainless steel wire, which made the fiber unbreakable. An approach was also proposed for batch producing, and good reproducibilities for fiber to fiber and between fibers were achieved. Experiments showed that the sol–gel-CNT fiber exhibited high thermal stability to resist 350 °C and excellent solvent durability in methanol and acetonitrile. Compared to commercial polydimethylsiloxane (PDMS) fiber, the sol–gel-CNT fiber represented significantly improved extraction efficiencies for both polar (phenols) and non-polar (benzene, toluene, ethylbenzene, and o-xylene) compounds. Meanwhile, no replacement effect, low carry-over and wide linear range demonstrated that the newly prepared sol–gel-CNT coating has liquid properties, which allow a relatively easy quantification procedure. Moreover, the characterization of the sol–gel-CNT coating was also evaluated with McReynold probe solutes. The results showed that the coating has better affinity for all the five types of solutes compared to commercial 7 μm PDMS fiber, which suggested that the coating has the potential to be developed as GC stationary phase.  相似文献   

14.
Li Q  Ding Y  Yuan D 《Talanta》2011,85(2):1148-1153
A platinum plate coated with single-walled carbon nanotubes (SWCNTs@Pt) was prepared by means of electrophoretic deposition. Using the SWCNTs@Pt plate, an electrosorption-enhanced solid-phase microextraction (EE-SPME) technique was proposed for the extraction of trace anions in water, described as follows: a positive potential was applied to the SWCNTs@Pt plate to extract F, Cl, Br, NO3 and SO42− from water using electrosorption, and then a negative potential was applied to the plate placed in ultra-pure water for the desorption of the absorbed anions, and finally the desorbed anions were analyzed using ion chromatography (IC). The EE-SPME parameters, including extraction potential and time as well as desorption potential and time, were investigated. An analytical method based on the above procedures, i.e., EE-SPME-IC, was established and used for the analysis of trace anions in water. The results showed that the application of potential on the SWCNTs@Pt plate significantly enhanced the ion extraction efficiency, and an enrichment factor of 15-38 was achieved. The SWCNTs@Pt plate could be used more than 50 times without significant decay. The linear range, the limit of detection (S/N = 3), the limit of quantification (S/N = 10) and repeatability (n = 7) of our EE-SPME-IC method were 1.0-150.0 μg/L, 0.06-0.26 μg/L, 0.19-0.85 μg/L and 2.1-8.0%, respectively. The proposed method was successfully applied for the analysis of trace anions in deionized water, and acceptable recoveries between 65.3 and 121.1% were obtained for the spiked deionized water samples.  相似文献   

15.
A molecularly imprinted polymer (MIP) with metolachlor as template was firstly coated on stainless steel fiber through chemical bonding strategy to solve the fragility problem of silica fiber substrate for solid-phase microextraction. The surface pretreatment of stainless steel fiber and the polymerization conditions were investigated systematically to enhance the preparation feasibility and MIP coating performance, and then a porous and highly cross-linked MIP coating with 14.8-μm thickness was obtained with over 200 times re-usability which was supported by non-fragile stainless steel fiber adoption. The MIP coating possessed specific selectivities to metolachlor, its metabolites and other chloroacetanilide herbicides with the factors of 1.1–4.6. Good extraction capacities of metolachlor, propisochlor and butachlor were found with MIP coating under quick adsorption and desorption kinetics, and the detection limits of 3.0, 9.6 and 38 μg L−1 were achieved, respectively. Moreover, the MIP-coated stainless steel fiber was evaluated for trace metolachlor, propisochlor and butachlor extraction in the spiked soybean and corn samples, and the enrichment factors of 54–60, 27–31 and 15–20 were obtained, respectively.  相似文献   

16.
Huang J  Hu Y  Hu Y  Li G 《Talanta》2011,83(5):1721-1729
In this paper, a novel metal complex imprinted polymer (CIP) coated solid-phase microextraction (SPME) fiber was prepared which could recognize the complex template [Cu(OAc)2(2,2′-dipyridine)] in aqueous medium. The saturating adsorption capacity of CIP-coated fiber was 2.2 and 2.6 times greater than those of molecularly imprinted polymer (MIP) coated fiber and nonimprinted polymer (NIP) coated fiber, respectively. Extraction conditions that influenced the recognition performance of CIP-coated fiber were investigated including pH, extraction solvent, metal ion species, etc. The ligand selectivity was also evaluated and discussed. The results demonstrated that CIP-coated fiber had better binding affinity for 2,2′-dipyridine compared to its structure analogues. The recognition ability of CIP coating was stable and effective in aqueous medium while MIP coating showed weak imprinting effect due to disturbance from protic solvent. 2,2′-dipyridine extracted by CIP-coated fiber using HPLC/UV detection resulted in a linear range of 10-200 μg/L with a detection limit of 2.0 μg/L. The proposed method was successfully applied to the analysis of 2,2′-dipyridine in spiked tap water, laboratory wastewater and human urine samples with recoveries 80.3-103.3% and RSDs 5.5-8.9%.  相似文献   

17.
In this paper, bamboo charcoals were modified using Fe3O4 nanosheets for the first time. The composites, as a novel solid-phase microextraction (SPME) fiber coating, were used for the extraction of seven polybrominated diphenyl ethers (PBDEs) in environmental water samples. The extraction factors (stirring rate, extraction time, and ionic strength) and desorption factors (desorption time and desorption temperature) of the fibers were systematically investigated and optimized. Under optimum conditions, the linear range was 1–1000 ng L−1. Based on the ratio of chromatographic signal to base line noise (S N−1 = 3), the limits of detection (LODs) can reach 0.25–0.62 ng L−1. The novel method was successful in the analysis of PBDEs in real environmental water samples. The results indicate that bamboo charcoal/Fe3O4 as an SPME coating material coupled with gas chromatography–negative chemical ionization-mass spectrometry is an excellent method for the routine analysis of PBDEs at trace levels in environmental water samples.  相似文献   

18.
Water-compatible pefloxacin-imprinted monoliths synthesized in a water-containing system were used for the selective extraction of fluoroquinolones (FQs). The MIP monolith was synthesized by using methacrylic acid as the functional monomer, di(ethylene glycol) dimethacrylate as a cross-linker and methanol–water (10:3, v/v) as the porogenic solvent. The ability of the derivated MIP for selective recognition of FQs (ciprofloxacin, difloxacin, danofloxacin and enrofloxacin) and quinolones (flumequine, and oxolinic acid) was evaluated. The derivated monolith showed high selectivity and was able to distinguish between FQs and quinolones. A simple rapid and sensitive method using polymer monolith microextraction (PMME) based on the MIP monolith combined with HPLC with fluorescence detection was developed for the determination of four FQs from milk samples. Owing to the unique porous structure and flow-through channels in the network skeleton of the MIP monolith, phosphate buffer diluted milk samples were directly supplied to PMME; allowing non-specific bound proteins and other biological matrix to be washed out, and FQs to be selectively enriched. The limit of detection of the method was 0.4–1.6 ng/mL and recovery was 92.4–98.2% with relative standard deviations less than 5.9%.  相似文献   

19.
《Analytical letters》2012,45(16):2477-2486
A novel solid-phase microextraction (SPME) fiber was prepared by coating multiwalled carbon nanotube (MWCNTs) on a stainless steel wire, and its characteristics were studied. To evaluate the MWCNTs coating, the fiber was used for the extraction of some organochlorine pesticides (OCPs) from water samples by Headspace SPME (HS-SPME) mode. Potential factors affecting the extraction efficiency such as extraction time, extraction temperature, agitation, ionic strength, desorption temperature, and time were also optimized. Several experiments were carried out by water spiked with target compounds to evaluate the analytical characteristics of the proposed method under optimized conditions. The linearity was from 0.1 to 10 ug/L with the linear correlation coefficients (r) ranging from 0.9956 to 0.9995. The limits of detection (LOD, S/N = 3) for these pesticides were between 0.43 and 2.13 ng/L and the precision (RSD, n = 5) was 2.53–12.25%. When this method was applied for the spiked real river sample, the relative recoveries ranged from 72.4% to 134.7% for the tested OCPs.  相似文献   

20.
A dispersive solid-phase microextraction (dispersive-SPME) method for the determination of tetracycline, oxytetracycline, chlortetracycline and doxycycline is proposed. Different silica-based and polymeric sorbents were evaluated for their capacity to simultaneously preconcentrate tetracyclines (TCs) in the dispersive format from aqueous or organic solutions. Silica-based sorbents especially functionalized with primary amine, secondary amine, or carbonyl groups have showed higher capacity than polymeric sorbents under organic environment. In the proposed dispersive solid-phase microextraction method, after extraction with acetonitrile and salt-promoted partitioning, TCs were adsorbed to a small amount of dispersive silica-based primary and secondary amine sorbents, desorbed with a small volume of desorption solution, and determined by high-performance liquid chromatography with diode-array detection. Under the optimal conditions, recoveries were determined for surface water and milk samples spiked at 10 ng/mL and 50–150 ng/g, respectively, and quantification was achieved by matrix-matched calibration. The calibration curves of four TCs in both samples showed linearity with a correlation coefficient value above 0.997. Average recoveries ranged from 97.1 to 104.1% and the precision was from 2.0 to 5.6%. Limits of detection ranged from 0.7 to 3.5 ng/mL and from 7.9 to 35.3 ng/g for four TCs surface in surface water and milk samples, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号