首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 92 毫秒
1.
保健食品中壮阳类西药成分的核磁共振氢谱定量分析   总被引:1,自引:0,他引:1  
建立了保健食品中枸橼酸西地那非、他达拉非、伐地那非的核磁共振氢谱定量(1H q NMR)分析方法。采用布鲁克Avance DRX 500超导核磁共振波谱仪,以氘代二甲亚砜为溶剂,2,3,5-三碘苯甲酸为内标物,优化了仪器采集参数,并进行了方法验证。结果表明:当内标添加量为2 mg、内标与待测化合物摩尔比在1∶0.1~1∶1.2范围时,标准曲线线性良好,相关系数(r2)不小于0.999;枸橼酸西地那非、他达拉非、伐地那非的检出限分别为0.045,0.026,0.033 mg/m L,定量下限分别为0.218,0.128,0.159 mg/m L;日内精密度RSD值分别为0.38%,0.85%,0.34%;日间精密度RSD值分别为0.72%,1.2%,1.4%。利用所建立的方法对13种实际样品进行定量分析;并将测试结果与HPLC-DAD法测试结果进行比较,两种测试结果的RSD在1%~8%之间。  相似文献   

2.
提出了基于二维近红外-中红外相关谱判别掺假芝麻油的方法。分别配制了40个纯芝麻油样品和40个掺假芝麻油(掺入的玉米油的体积分数在3%~60%之间)样品,并采集了所有样品的近红外光谱和中红外光谱。在4 540~6 000cm~(-1)对650~1 800cm~(-1)内进行同步二维近红外-中红外相关谱计算,建立了掺假芝麻油的多维偏最小二乘判别模型,并将其预测性能与二维近红外相关谱和二维中红外相关谱判别模型的预测性能进行了比较。结果表明:上述3个模型对预测集未知样品的判别正确率分别为96.3%,92.6%,96.3%。  相似文献   

3.
采用近红外漫反射光谱法对头孢氨苄粉末药品中主要成分头孢氨苄进行快速、无损定量分析.采用偏最小二乘法建立近红外光谱信息与待测组分含量间的最佳数学校正模型.对3种光谱(SNV光谱、一阶导数、二阶导光谱)的预测结果进行了比较,讨论了光谱的预处理方法和主成分数对偏最小二乘法定量预测能力的影响,并对预测集样品进行预测.  相似文献   

4.
建立了使用近红外光谱法(NIR)快速测定溶剂型木器涂料中甲苯、乙苯和二甲苯的方法。收集涂料样品,使用气相色谱法(GC)测定苯系物含量。采用聚乙烯密实袋封装聚氨酯类、硝基类或醇酸类涂料,应用积分球透漫射采样方式采集清漆和漫射采样方式采集色漆的近红外光谱。采用偏最小二乘法,分别建立清漆和色漆的近红外光谱与苯系物线性关系模型。校正集均方差在0.43%~1.32%之间、相关系数R在0.9046~0.9766之间。验证集均方差在0.591%~1.73%之间。对未知样品预测,清漆样品预测值相对偏差<15%;色漆样品预测值相对偏差<20%。两个定量模型预测效果良好。该2个NIR定量方法适用于对溶剂型木器涂料中甲苯、乙苯和二甲苯含量进行快速测定。  相似文献   

5.
专利     
《化学分析计量》2012,(5):51+61-51
一种近红外光谱无损鉴别山参真伪的方法 :一种近红外光谱无损鉴别山参真伪的方法,属于中药检测技术领域,目的在于解决现有技术鉴别山参鉴别结果不确定及鉴别过程破坏山参形体的问题。采集山参和工艺参的光谱数据,经主成分分析法提取出主成分变量作为输入变量,设定山参及工艺参的属性代码并将其作为目标变量,根据输入变量和目标变量训练网络,建立BP人工神经网络模型;采集待鉴别样品光谱数据,并经建立的BP人工神经网络模型进行仿真,输出待鉴别样品预测值,参照山参和工艺参的属性代码判断待鉴别样品。当待鉴别样品  相似文献   

6.
采用新型制样法,应用漫反射傅里叶变换红外光谱(DRIFTS)法测定了维生素B_1片剂中维生素B_1的含量。选择波数1659cm~(-1)处的吸收峰作为定量吸收峰,片剂辅料中不含和含有酒石酸或枸橼酸的样品分别用1630~1690cm~(-1)范围内的峰面积和1654cm~(-1)处的单波数评估吸光度,吸光度与质量分数均呈良好的线性关系,相关系数0.98,相对标准偏差(RSD)≤6.2%。定量分析市售4种维生素B_1片剂,结果与药典中紫外分光光度(UV)法基本一致。DRIFTS法操作简便、快速、样品前处理简单、无试剂消耗、无废液产生,选择适合的吸光度评估方法和基线校正范围可排除可溶性杂质对分析测定的干扰,定量分析结果准确。  相似文献   

7.
提出了近红外光谱法快速测定再造烟叶成品小片中烟碱、总糖、还原糖、总氮、钾、氯等6种主要化学成分的方法。直接采集再造烟叶成品小片,结合偏最小二乘回归算法建立了近红外光谱的分析模型。结果表明:再造烟叶成品小片的近红外光谱能真实、有效地表征待测样品的内在化学物质组成与含量信息;除总氮外,其余5种成分的再造烟叶成品小片近红外光谱分析模型的相关系数均大于0.90;烟碱、总糖、还原糖、总氮、钾、氯等6种成分的预测误差分别为0.024 3,0.399 1,0.270 3,0.059 9,0.050 3,0.031 1。小片光谱分析模型效果与粉末光谱模型较接近,可以替代粉末模型用于再造烟叶成品小片化学成分含量的测定。  相似文献   

8.
基于Bayesian相似性评估方法结合偏最小二乘局部回归,对苹果近红外数据库进行数据挖掘。通过相似性计算方法搜索出与预测样品相近的近红外光谱,形成校正子集后采用局部回归方法获得待测样品的相关信息。该方法所建立局部模型的平均检验标准偏差(SEV)约为0.57,分析30个预测样品的预测标准偏差(SEP)约为0.61;基于马氏距离的传统方法建立的偏最小二乘局部模型的平均SEV为0.59,分析30个待测样品的预测SEP为0.64;而采用整个数据库建立的全局偏最小二乘模型的SEV约为0.65,分析30个预测样品SEP约为0.70。基于Bayesian相似性评估的局部回归方法在苹果糖度的近红外无损定量分析中获得较好的应用结果,在实际应用中该方法比全局回归方法具有更强的适用性,为近红外光谱分析提供了新的分析工具。  相似文献   

9.
根据市售鼠药样品成分各异且相对复杂,建立6种不同成分体系和9个不同样本容量的校正集,运用小波变换压缩鼠药的近红外透射光谱数据,结合BP反向神经网络算法对压缩的数据进行建模,考察校正集样品特性对模型预测能力的影响。试验结果表明:采用BP神经网络算法建立定量模型时,只要校正集样品中包含了与预测样品性质相似的样本,就能准确地对复杂样品进行近红外定量分析。当校正集容量分别为72和84时,模型预测结果趋于平稳。当校正集数量为96时,模型的最大相关系数为0.959 8,预测最小标准差和平均相对误差分别为1.893%和1.92%。  相似文献   

10.
近红外光谱法测定ABS树脂中氮含量   总被引:1,自引:0,他引:1  
根据58个丙烯腈-丁二烯-苯乙烯(ABS)树脂样品的近红外漫反射光谱数据结合偏最小二乘法(PLS)建立了ABS树脂中氮含量定量分析的校正模型。结果表明;在近红外光谱区(7501.8~5449.9cm~(-1))内,主因子数为9时,定量模型的准确度最好。通过对模型进行t-检验,在显著性水平为0.05的条件下,其测定结果与标准方法的测定结果对比,两者无显著性差异。预测相关系数(r)和相对标准偏差(RSD)分别为0.9924和3.3%。  相似文献   

11.
利用1H NMR技术、电喷雾质谱、红外光谱以及紫外吸收光谱法等手段研究了瓜环[n](n=7,8)与枸橼酸西地那非的相互作用。结果表明:枸橼酸西地那非与两种瓜环都形成了1∶1的包结配合物,但是其配合物的作用模式随瓜环的大小而不同。通过计算得出瓜环[n](n=7,8)与枸橼酸西地那非的包结常数分别为958和1530 L/mol,说明瓜环对枸橼酸西地那非具有潜在的缓释作用。  相似文献   

12.
A rapid, specific and reliable high performance liquid chromatographic (HPLC) assay of sildenafil in pharmaceutical dosage forms has been developed and evaluated. Reversed phase chromatography was conducted using a mobile phase of methanol: water: acetonitrile (60:20:20) v/v/v, pH 6.1, 0.1% glacial acetic acid, and detection at λ 290 nm. The recovery and coefficient of variation from six tablets containing 50 mg of sildenafil were 100.90% and 0.45% respectively. Replicate regression analysis of three standard plots in the concentration range (0.01–0.2) μg mL?1 obtained on three different days gave a correlation coefficient >0.999 and the coefficient of variation of the slopes <1.5%. The assay was precise within day and between days as indicated by ANOVA test. It is suggested that the proposed HPLC method should be used for routine quality control and dosage form assay of sildenafil citrate. The proposed method was also used to study the stability of sildenafil citrate in different dosage forms of the drug.  相似文献   

13.
The goal of this study was to develop a compact fiber optic probe to measure near infrared Raman spectra of human cervical tissue in vivo for the clinical diagnosis of cervical precancers. A Raman spectrometer and fiber optic probe were designed, constructed and tested. The probe was first tested using standards with known Raman spectra, and then the probe was used to acquire Raman spectra from normal and precancerous cervical tissue in vivo. Raman spectra of cervical tissue could be acquired in vivo in 90 s using incident powers comparable to the threshold limit values for laser exposure of the skin. Although some silica signal obscured tissue Raman bands below 900 cm-1, Raman features from cervical tissue could clearly be discerned with an acceptable signal-to-noise ratio above 900 cm-1. The success of the Raman probe described here indicates that near infrared Raman spectra can be measured in vivo from cervical tissues. Increasing the power of the excitation source could reduce the integration time to below 20 s.  相似文献   

14.
 The molecular interaction between sildenafil citrate as electron donor and each of iodine; 7,7,8,8-tetracyanoquinodimethane (TCNQ); 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ); tetracyanoethylene (TCNE); 2,4,7-trinitro-9-fluorenon (TNF); chloranilic acid (CLA); chloranil (CL) and bromanil (BL) as acceptors have been investigated spectrophotometrically. Different variables affecting the reaction were studied and optimized. Beer’s law was obeyed in a concentration limit of 10–260 μg/mL for sildenafil citrate. For more accurate analysis, Ringbom optimum concentration range was found to be between 20–240 μg/mL. The limits of detection and determination were calculated and found to be 1.5 and 5.2 μg/mL, respectively. The standard deviations were calculated for different concentrations of sildenafil citrate using various acceptors. A Job’s plot of the absorbance versus the molar ratio of the sildenafil citrate to each of acceptors under consideration indicated (1:1) ratio. The proposed methods were found to be rapid, accurate, precise and sensitive and could be applied for determination of sildenafil citrate in pharmaceutical dosage forms (Viagra) without interferences from common additives encountered. Received August 30, 2000. Revision January 5, 2001.  相似文献   

15.
The purpose of this study was to identify the effect of sildenafil citrate on IL-1β-induced nitric oxide (NO) synthesis and iNOS expression in human synovial sarcoma SW982 cells. IL-1β stimulated the cells to generate NO in both dose- and time-dependent manners. The IL-1β-induced NO synthesis was inhibited by guanylate cyclase (GC) inhibitor, LY83583. When the cells were treated with 8-bromo-cGMP, a hydrolyzable analog of cGMP, NO synthesis was increased upto 5-fold without IL-1β treatment suggesting that cGMP is an essential component for increasing the NO synthesis. Synoviocytes and chondrocytes contain strong cGMP phosphodiesterase (PDE) activity, which has biochemical features of PDE5. When SW982 cells were pretreated with sildenafil citrate (Viagra), a PDE5 specific inhibitor, sildenafil citrate significantly inhibited IL-1β-induced NO synthesis and iNOS expressions. From this result, we noticed that PDE5 activity is required for IL-1β-induced NO synthesis and iNOS expressions in human synovial sarcoma cells, and sildenafil citrate may be able to suppress an inflammatory reaction of synovium through inhibition of NO synthesis and iNOS expression by cytokines.  相似文献   

16.
Cui X  Zhang Z  Ren Y  Liu S  Harrington Pde B 《Talanta》2004,64(4):943-948
Temperature-constrained cascade correlation networks (TCCCNs) were applied to the identification of the powder pharmaceutical samples of sulfaguanidine based on near infrared (NIR) diffuse reflectance spectra and their first derivative spectra. This work focused on the comparison of performances of the uni-output TCCCN (Uni-TCCCN) and multi-output (Multi-TCCCN) by near infrared diffuse reflectance spectra and their first derivative spectra of sulfaguanidine. The TCCCN models were verified with independent prediction samples by using the “cross-validation” method. The networks were used to discriminate qualified, un-qualified and counterfeit sulfaguanidines pharmaceutical powders. The results showed that single outputs network generally worked better than the multiple outputs networks, and the first derivative spectra were more suitable for the identification comparing with original diffuse reflectance spectra. With proper network parameters the pharmaceutical powders can be classified at rate of 100% in this work. Also, the effects of parameters and related problems were discussed.  相似文献   

17.
To investigate the correlation between the wavelength dependence of ionization threshold fluence of target molecule in matrix‐assisted laser desorption/ionization by infrared (IR) laser and the IR absorption spectrum of matrix molecule, we have analyzed the IR absorption spectra of four matrix molecules using density functional theory and correlated ab initio molecular orbital method. The calculated IR absorption spectra of the isolated molecules showed more qualitative correlation with the wavelength dependence of ionization threshold fluence than those of the solid state structures. We can consider that a portion of matrix molecules lost the ordered crystal structure and that the transition to the diluted or isolated state occurred at the early process of IR laser irradiation. © 2012 Wiley Periodicals, Inc.  相似文献   

18.
自适应小波算法用于近红外光谱的多元校正   总被引:2,自引:0,他引:2  
吴荣晖  邵学广 《分析化学》2005,33(7):1010-1012
实现了一种构建自适应小波滤波器的方法,并将其用于近红外光谱数据的多元校正。该方法根据一定的目标函数,针对信号的特性自适应地构造小波滤波器。用该法构建的滤波器对烟草样品的近红外光谱进行压缩,并将压缩后的数据采用偏最小二乘法建模,实现了烟草样品常规组分的定量分析。  相似文献   

19.
Three types of monocrystalline diamond: natural diamond 1 μm, synthetic diamond 50 μm (synthetic-1), and synthetic diamond 1 μm (synthetic-2) were used for the design of diamond paste electrodes for the determination of sildenafil citrate (Viagra) using square wave voltammetry. The linear concentration ranges recorded for sildenafil citrate when natural diamond, synthetic-1, and synthetic-2 based electrodes were used were between 10−12 and 10−8, 10−12 and 10−9, and 10−11 and 10−9 mol/L, respectively. Low detection limits which lie between 0.1 and 1 pmol/L proves the sensitivity of the electrodes. It was found that sildenafil citrate yielded a peak at about +0.175 ± 0.025 V (versus Ag/AgCl) for all the electrodes. Sildenafil citrate was determined with high reliability from its pharmaceutical formulation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号