首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Metformin is a well‐known oral antihyperglycemic drug used in treatment of type II diabetes. Analysis of metformin in biological fluids is a challenge owing to its high polarity and small molecular size, which lead to poor retention of metformin on reversed‐phase liquid chromatographic columns. A high‐throughput method was developed and validated for the determination of metformin in rat plasma in support of preclinical toxicology studies, using hydrophilic interaction liquid chromatography tandem mass spectrometry (HILIC‐MS/MS) and Tecan automated sample preparation. Extracted samples were directly injected onto the unbounded silica column with an aqueous–organic mobile phase. This HILIC‐MS/MS method was validated for accuracy, precision, sensitivity, stability, matrix effect, recovery and calibration range. Acceptable intra‐run and inter‐run assay precision (coefficient of variation ≤ 3.9%) and accuracy (99.0–101.8%) were achieved over a linear range of 50–50,000 ng/mL. Metformin is stable in rat plasma for at least 6 h at room temperature, 147 days at ?70°C and through three freeze (?70°C) and thaw cycles. Metformin is also stable in rat whole blood for at least 2 h at room temperature and in an ice–water bath. The validated method was successfully used in support of several preclinical studies where metformin is dosed together with an investigational drug substance. The ruggedness of the validated method was demonstrated by the incurred sample reproducibility test. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

2.
Hydrophilic interaction liquid chromatography (HILIC) interfaced with atmospheric pressure ionization (API) sources and a tandem mass spectrometer (MS/MS) was developed for the simultaneous determination of dasatinib, imatinib and nilotinib in mouse plasma samples. The retention profiles of all analytes on several silica stationary phases under HILIC conditions were explored. The influences of experimental factors such as the compositions of mobile phases on the chromatographic performance and the ionization efficiency of all analytes in positive ion mode were investigated. The applicability of the proposed HILIC/MS/MS approach following a protein precipitation procedure for the quantitative determination of dasatinib, imatinib and nilotinib at low nano‐mole levels was examined with respect to assay specificity and linearity. The analytical results obtained by various HILIC/MS/MS approaches were found to be in good agreement with those obtained by reversed‐phase liquid chromatography/tandem mass spectrometry (RPLC/MS/MS) methods in terms of assay sample throughputs, sensitivity and accuracy. Furthermore, the potential of matrix ionization suppression on the proposed HILIC/MS/MS systems was investigated using the post‐column infusion technique. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
A method coupling hydrophilic interaction chromatography (HILIC) with tandem mass spectrometry (MS/MS) has been developed for the simultaneous determination of three polar non‐structurally related compounds – a carbapenem antibiotic, imipenem (IMP), a renal dehydropeptidase inhibitor, cilastatin (CIL), and an investigational β‐lactamase inhibitor, MK‐4698 (BLI), in rat plasma, monkey plasma and mouse blood. The analytes were extracted through protein precipitation, chromatographed on a Waters Atlantis HILIC column, and detected on a Sciex API4000 mass spectrometer using a Turbo‐Ion Spray ion source in positive ionization mode following multiple‐reaction monitoring (MRM). The assay dynamic range was 0.1–100 µg/mL for IMP, CIL and BLI, respectively, using a total of 20–25 µL biologic samples, and the total HPLC/MS/MS run time was 4 min/injection. The assay was found to be sensitive, selective and reproducible. The challenges, namely, sample stability, blood sample processing, matrix effect in monkey study samples, and dilution re‐assays for the limited mouse blood samples, are resolved and discussed. This technique allowed rapid analysis of polar compounds in biologic matrixes with satisfactory chromatographic retention and increased throughput. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
A specific and automated method was developed to quantify the anticonvulsants gabapentin, pregabalin and vigabatrin simultaneously in human serum. Samples were prepared with a protein precipitation. The hydrophilic interaction chromatography (HILIC) with a mobile phase gradient was used to divide off ions of the matrix and for separation of the analytes. Four different HILIC‐columns and two different column temperatures were tested. The Tosoh‐Amid column gave the best results: single small peaks. The anticonvulsants were detected in the multiple reaction monitoring mode (MRM) with ESI‐MS‐MS. Using a volume of 100 μL biological sample the lowest point of the standard curve, i.e. the lower LOQs were 312 ng/mL. The described HILIC‐MS‐MS method is suitable for therapeutic drug monitoring and for clinical and pharmcokinetical investigations of the anticonvulsives.  相似文献   

5.
Ultra‐performance hydrophilic interaction liquid chromatography (UPHILIC) interfaced with the electrospray ionization (ESI) source of a tandem mass spectrometer (MS/MS) was developed for the simultaneous determination of everolimus in mouse plasma samples. UPHILIC was performed on a sub‐2 µm bare silica particle packing with the column pressure under traditional high‐performance liquid chromatography (HPLC) to allow fast separation of pharmaceutical compounds within a chromatographic analysis time of 1 min. This UPHILIC technology is comparable with reversed‐phase ultra‐performance liquid chromatography (RPUPLC) in terms of chromatographic efficiency but demands neither expensive ultra‐high‐pressure instrumentation nor new laboratory protocols. With the ESI source, multiple reaction monitoring (MRM) of the ammoniated adduct ions of the analyte was used for tandem mass spectrometric detection. The retention mechanism profiles of the test compounds under HILIC conditions were explored. The influences of experimental factors such as the compositions of mobile phases on the chromatographic performance and the ionization efficiency of the test compounds in positive ion mode were investigated. A UPHILIC/MS/MS approach following a protein precipitation procedure was applied for the quantitative determination of everolimus at the low ng/mL region in support of a pharmacodynamic study. The analytical results obtained by the UPHILIC/MS/MS approach were fond to be in good agreement with those obtained by the RPUPLC/MS/MS method in terms of assay sample throughput, sensitivity and accuracy. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
A two‐dimensional (2D) hydrophilic interaction liquid chromatography (HILIC) and reverse‐phase (RP) liquid chromatography (LC) system coupled with triple‐quadrupole mass spectrometry (MS) was developed to comprehensively profile ceramides and phosphatidylcholine in extracted biological samples. Briefly, the 2D HILIC‐RPLC system used a silica HILIC column operated in the first dimension to distinguish the lipid classes and a BEH C18 column operated in the second dimension to separate the lipid species of the same class. The regression linearity of each lipid was satisfactory in both systems; however, the absolute matrix effect factor was reduced in 2D LC‐MS/MS system. Limits of detection of 2D LC‐MS/MS system were 2‐ to 3‐fold lower compared with one‐dimensional RPLC‐MS/MS. The recovery from the sample ranged from 84.5 to 110%. To summarize, the developed method was proven to be accurate and producible, as relative standard deviations remained <20% at three spiked levels. The efficiency of this newly developed system was applied to measure changes of lipids in the liver of mice after naphthalene treatment. Orthogonal projection to latent structures‐discriminant analysis discriminated the lipids from control and the treatment group. We concluded that 2D LC‐MS/MS is a promising method to assist lipidomic studies of complex biological samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
A method combining hydrophilic interaction liquid chromatography (HILIC) with tandem mass spectrometry (MS/MS) was developed for the determination of polar organophosphorus pesticides (OPPs; acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl, and vamidothion) in water samples. To extract the polar OPPs and minimize matrix effects from the water sample, an activated carbon cartridge was used for pretreatment. After pretreatment of the water sample, the eluate from the activated carbon cartridge was directly injected into the HILIC/MS/MS system. The OPPs were separated on an Atlantis HILIC silica column by isocratic elution with a mixture of acetonitrile, isopropanol, and ammonium formate buffer as a mobile phase, and they were detected by positive electrospray ionization MS/MS in the selected reaction monitoring mode. The method was validated at 0.05, 0.5, and 5 microg/L levels in water samples, and the recoveries of polar OPPs were between 76.4 and 98.6%. The limits of detection were between 0.13 and 1.0 pg on-column, and the limits of quantification were between 0.43 and 3.4 pg on-column. The method can be applied to the determination of trace amounts of OPPs in environmental water samples.  相似文献   

8.
A selective and sensitive HILIC‐MS/MS method for the simultaneous quantification of nicotine and its metabolites in human maternal and cord sera was developed and validated. After solid‐phase extraction, LC separation was achieved on a hydrophilic interaction chromatography. The validated method is capable of selective identification as well as accurate and sensitive quantification. Analyte recovery ranged from 86.2 to 107.7% and intra‐ and inter‐day assay precision were less than 15% relative standard deviation. This sensitive HILIC‐MS/MS method can be used to determine nicotine and its metabolic profile in smokers. This validated method is useful for the determination of nicotine and its metabolites in human serum in future studies of the effects of nicotine exposure on neonatal outcome. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
Mass spectrometry (MS)‐based proteomics provides unprecedented opportunities for understanding the structure and function of proteins in complex biological systems; however, protein solubility and sample preparation before MS remain a bottleneck preventing high‐throughput proteomics. Herein, we report a high‐throughput bottom‐up proteomic method enabled by a newly developed MS‐compatible photocleavable surfactant, 4‐hexylphenylazosulfonate (Azo) that facilitates robust protein extraction, rapid enzymatic digestion (30 min compared to overnight), and subsequent MS‐analysis following UV degradation. Moreover, we developed an Azo‐aided bottom‐up method for analysis of integral membrane proteins, which are key drug targets and are generally underrepresented in global proteomic studies. Furthermore, we demonstrated the ability of Azo to serve as an “all‐in‐one” MS‐compatible surfactant for both top‐down and bottom‐up proteomics, with streamlined workflows for high‐throughput proteomics amenable to clinical applications.  相似文献   

10.
A hydrophilic interaction chromatography/mass spectrometry (HILIC‐MS)‐based assay for imipenem (IMP) and cilastatin (CIL) was recently reported. This orthogonal electrospray ion source‐based (ORS) assay utilized nonvolatile salt (unremovable) to stabilize IMI in plasma. Unfortunately, this method was not applicable to conventional MS with off‐axis spray (OAS‐MS) because MS sensitivity was rapidly deteriorated by the nonvolatile salt. Therefore, we aimed to find a nonvolatile salt‐ and ion suppression‐free approach to stabilize and measure the analytes in plasma using OAS‐MS. Acetonitrile and methanol were tested to stabilize the analytes in the plasma samples. The recoveries, matrix effects and stabilities of the analytes in the stabilizer‐treated samples were studied. The variations in MS signal intensities were used as the indicator of the assay ruggedness. The results show that a mixture of methanol and acetonitrile (1:1) is best for the storage and measurement of IMP and CIL in human plasma. Utilization of this precipitant not only blocked the hydrolysis of the analytes in plasma but also resulted in an ion suppression‐free, fast (120 s per sample) and sensitive detection. The sensitivity obtained using the less sensitive OAS‐MS (API3000, 4 pg on column) is much greater than that of the published ORS‐MS‐based assay (API4000, 77 pg on column). The ruggedness of the assay was demonstrated by its constant MS signal intensity. In conclusion, an improved HILIC/MS‐based assay for IMP and CIL was established. The approach presented here provides a simple solution to the challenge of analyzing hydrolytically unstable β‐lactam antibiotics in biological samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
The development of targeted assays for polar molecules is a persistent challenge in quantitative metabolite measurement. In addressing these challenges, hydrophilic interaction liquid chromatography (HILIC) has proved to be a valuable, though under-used and poorly understood chromatographic technique. This work has addressed a number of components that are intrinsic in development of a high-throughput, specific and sensitive assay for metabolites using HILIC-MS/MS. Generally accepted HILIC doctrine, such as addition of water to all mobile phases and re-equilibration time, was shown to be flawed under gradient HILIC mode. The effect of non-classical mobile phase additives on HILIC-MS/MS specificity, sensitivity and assay throughput was shown for endogenous metabolites. A broad evaluation of columns and mobile phases for the retention of varied molecular classes was performed, elucidating the empirical nature of HILIC method development. Application of the empirical evaluations performed in the paper was demonstrated by detailing a method development cycle for methylmalonic acid to achieve a highly selective and sensitive HILIC-MS/MS quantitation capable of high-throughput analysis for clinical utility.  相似文献   

12.
Trigonelline is a pyridine alkaloid found in fenugreek seeds and coffee beans. Most of the previous studies are concerned with the quantification of trigonelline along with other constituents in coffee herbs or beverages. Only a few have focused on its determination in animal or human tissues by applying different modes of HPLC with UV or MS detection. The aim of the study was to develop and validate a fast and simple method for trigonelline determination in serum by the use of hydrophilic interaction liquid chromatography (HILIC) with ESI‐MS/MS detection. Separation of trigonelline was achieved on a Kinetex HILIC column operated at 35°C with acetonitrile–ammonium formate (10 mm , pH = 3) buffer mixture (55:45, v/v) as the mobile phase. The developed method was successfully applied to determine trigonelline concentration in mouse serum after intravenous administration of 10 mg/kg. The developed assay is sensitive (limit of detection = 1.5 ng/mL, limit of quantification = 5.0 ng/mL) and linear in a concentration range from 5.0 to 250.0 ng/mL. Sample preparation is limited to deproteinization, centrifugation and filtration. The application of the HILIC mode of chromatography with MS detection and selection of deuterated trigonelline as internal standard allowed a rapid and precise method of trigonelline quantification to be to developed.  相似文献   

13.
采用自动前处理LC/MS进行血浆中药物的快速分析   总被引:3,自引:0,他引:3  
药物研究的发展对高通量的样品处理分析提出了越来越高的要求,减少样品制备时间和分析时间是解决问题的关键。我们新近发展了一种具有在线稀释旁路和新的样品预处理柱的Shim-Pack MAYI-ODS自动柱切换HPLC和LC/MS系统,该系统无需样品前处理,可直接进样进行血浆、血清中的药物分析。本文利用自动样品前处理LC/MS系统,用ODS整体柱实现了血浆中药物的快速分析。包括样品预处理,整个分析仅需1.2min完成。  相似文献   

14.
ATP‐Binding Cassette (ABC) transporters are highly expressed in pharmacological barriers limiting the access of drugs to their targets. Since characterization of a compound as a transporter substrate or inhibitor bears significant consequences in drug development, there is a great need for reliable tools that enable the rapid analysis of the transport susceptibility of drugs. Here we describe a simple but very efficient high‐performance liquid chromatography/mass spectrometry (HPLC/MS) assay for measuring the ABC transporter‐dependent vesicular transport of compounds. In addition, we provide evidence that the requirement for sample preparation can be minimized using desorption electrospray ionization (DESI)‐MS, paving the way for a direct, high‐throughput investigation of drug‐transporter interactions. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
In the present study, hydrophilic interaction liquid chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) combined with tandem mass spectrometric detection (MS/MS) were evaluated and compared for the determination of donepezil, cetirizine and loratadine in human plasma, in terms of sensitivity and sample preparation procedure. A retention study for the above compounds of various polarities was performed, using both C(18) and silica columns, with several aqueous-organic mobile phase ratios, in order to investigate their retention mechanism profile under HILIC and RPLC. Both chromatographic conditions were compared for chromatographic analysis of plasma samples processed with a liquid-liquid extraction (LLE) method for donepezil determination, resulting in significantly higher sensitivity under HILIC. Furthermore, HILIC and RPLC were compared for direct injection, and novel methods including LLE, solid-phase extraction and protein precipitation protocols were developed. Direct injection technique significantly reduced sample preparation time, increasing at the same time method sensitivity. The current study contributes to broadening the range of analyzable compounds by HILIC-MS/MS to molecules of medium polarity.  相似文献   

16.
A multiplexed system based on inductive nanoelectrospray mass spectrometry (nESI‐MS) has been developed for high‐throughput screening (HTS) bioassays. This system combines inductive nESI and field amplification micro‐electrophoresis to achieve a “dip‐and‐go” sample loading and purification strategy that enables nESI‐MS based HTS assays in 96‐well microtiter plates. The combination of inductive nESI and micro‐electrophoresis makes it possible to perform efficient in situ separations and clean‐up of biological samples. The sensitivity of the system is such that quantitative analysis of peptides from 1–10 000 nm can be performed in a biological matrix. A prototype of the automation system has been developed to handle 12 samples (one row of a microtiter plate) at a time. The sample loading and electrophoretic clean‐up of biosamples can be done in parallel within 20 s followed by MS analysis at a rate of 1.3 to 3.5 s per sample. The system was used successfully for the quantitative analysis of BACE1‐catalyzed peptide hydrolysis, a prototypical HTS assay of relevance to drug discovery. IC50 values for this system were in agreement with LC‐MS but recorded in times more than an order of magnitude shorter.  相似文献   

17.
Levosimendan (Simdax) is an approved drug in approximately 40 countries and currently in phase III clinical studies in the USA and Europe. An accurate, high-throughput and rugged assay is critical to support these clinical trials. Due to the mechanism of drug metabolism, the drug and its active metabolites often have significant differences in their chemical properties. In order to achieve high assay throughput and low sample volumes, a single bioanalytical assay for the drug and its metabolites is preferred. However, this need may prevent the optimization of both high-performance liquid chromatography (HPLC) and mass spectrometric ionization conditions. The chemical properties of levosimendan are significantly different from those of its two active metabolites, OR-1855 and OR-1896. Here, we present a novel strategy for high-throughput analysis of levosimendan and its metabolites. A 96-well liquid/liquid extraction procedure was developed for sample preparation. A single liquid chromatography/tandem mass spectrometry (LC/MS/MS) system with two separate mobile phases, shared backwash solvent and conditioning solvent, was developed to perform sequential LC separation for levosimendan and the metabolites. Levosimendan was eluted by 5 mM ammonium acetate in 33.3% acetonitrile and detected using negative ionization mode MS/MS monitoring. The metabolites were eluted by 5 mM ammonium acetate and 0.2% acetic acid in 20% acetonitrile and detected with positive ionization mode MS/MS monitoring. The method has been demonstrated to have excellent precision and accuracy, with high assay ruggedness during method validation and clinical sample analysis. The linear dynamic ranges were approximately 200-50,000 pg/mL for levosimendan and approximately 500-130,000 pg/mL for both metabolites. The coefficient of determination (r2) for all analytes was greater than 0.9985. The intra-assay %CVs for QC samples were from 0.9% to 2.0% for levosimendan, 0.9% to 3.2% for OR-1855, and 0.4% to 4.9% for OR-1896. The inter-assay %CVs for QC samples were from 1.2% to 1.8% for levosimendan, 1.3% to 2.7% for OR-1855, and 1.4% to 3.4% for OR-1896. The mean % biases for QC samples were from 1.5% to 5.5% for levosimendan, -1.4% to 2.6% for OR-1855, and -0.3% to 4.5% for OR-1896. By using a single extraction approach coupled with sequential LC/MS/MS analysis for levosimendan and its metabolites, the assay maintained high throughput and low sample volume usage.  相似文献   

18.
High‐throughput metabolic analysis is of significance in diagnostics, while tedious sample pretreatment has largely hindered its clinic application. Herein, we designed FeOOH@ZIF‐8 composites with enhanced ionization efficiency and size‐exclusion effect for laser desorption/ionization mass spectrometry (LDI‐MS)‐based metabolic diagnosis of gynecological cancers. The FeOOH@ZIF‐8‐assisted LDI‐MS achieved rapid, sensitive, and selective metabolic fingerprints of the native serum without any enrichment or purification. Further analysis of extracted serum metabolic fingerprints successfully discriminated patients with gynecological cancers (GCs) from healthy controls and also differentiated three major subtypes of GCs. Given the low cost, high‐throughput, and easy operation, our approach brings a new dimension to disease analysis and classification.  相似文献   

19.
One fundamental requirement for many lead optimization processes is the need for bioanalytical support within pharmaceutical drug discovery and development. Currently, most bioanalytical methods for pharmaceutical analysis employ HPLC coupled with MS/MS. The combination of HPLC and MS/MS detection frequently offers the complete resolution of the dosed compounds from their metabolites and the endogenous interferences to avoid extra efforts for chemical separation and sample clean-up procedures resulting in higher-throughput assays for a series of new chemical entities (NCEs). Hydrophilic interaction chromatography (HILIC) has been demonstrated to be a powerful technique for the retention of polar analytes offering a difference in selectivity compared to traditional RP chromatography. This review summarizes the HILIC-MS/MS methods for the trace quantitative determinations of the drug compounds and their metabolites to support both in vitro and in vivo experiments. The challenges on performing HILIC-MS/MS assays such as matrix ionization suppression and the potential for endogenous interferences are also presented.  相似文献   

20.
Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the bioanalytical method of choice to support plate‐based, in vitro early ADME (Absorption, Distribution, Metabolism and Excretion) screens such as metabolic stability (Metstab) assessment. MS/MS method optimization has historically been the bottleneck in this environment, where samples from thousands of discrete compounds are analyzed on a monthly basis, mainly due to the lack of a high‐quality commercially available platform to handle the necessary MS/MS method optimization steps for sample analysis by selected reaction monitoring (SRM) on triple quadrupole mass spectrometers. To address this challenge, we recently developed a highly automated bioanalytical platform by successfully integrating QuickQuan? 2.0, a unique high‐throughput solution featuring MS/MS method optimization by automated infusion, with a customized in‐house software tool in support of a Metstab screen. In this platform, a dual‐column setup running parallel chromatography was also implemented to reduce the bioanalytical cycle time for LC/MS/MS sample analysis. A set of 45 validation compounds was used to demonstrate the speed, quality and reproducibility of MS/MS method optimization, sample analysis, and data processing using this automated platform. Metstab results for the validation compounds in microsomes from multiple species (human, rat, mouse) showed good consistency within each batch, and also between batches conducted on different days. We have achieved and maintained a monthly throughput of 1300 compound assays representing 500 discrete compounds per instrument per month on this platform, and it has been used to generate metabolic stability data for more than 25 000 compounds to date with an overall success rate of more than 95%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号