首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
A chlorinated coumarin-aldehyde was developed as a colorimetric and ratiometric fluorescent probe for distinguishing glutathione (GSH), cystenine (Cys) and homocysteine (Hcy). The GSH-induced substitution-cyclization and Cys/Hcy-induced substitution-rearrangement cascades lead to the corresponding thiol-coumarin-iminium cation and amino-coumarin-aldehyde with distinct photophysical properties. The probe can be used to simultaneously detect GSH and Cys/Hcy by visual determination based on distinct different colors – red and pale-yellow in PBS buffer solution by two reaction sites. From the linear relationship of fluorescence intensity and biothiols concentrations, it was determined that the limits of detection for GSH, Hcy and Cys are 0.08, 0.09 and 0.18 μM, respectively. Furthermore, the probe was successfully used in living cell imaging with low cell toxicity.  相似文献   

2.
设计合成了一种用于检测半胱氨酸的新型荧光探针乙二醛(N-羟乙基-1,8-二甲酰亚胺-4-萘基)单腙(NAD),该荧光探针对半胱氨酸表现出较高的灵敏度和选择性.当半胱氨酸加入NAD溶液中,会形成分子内氢键,抑制C■N的异构化,导致荧光增强.此外,探针NAD可应用于细胞内半胱氨酸的检测,表明该类型探针在生物检测应用方面具有较大的潜力.  相似文献   

3.
An ESIPT-based fluorescent probe (Probe 1) using acrylate as recognition group for the selective and sensitive detection of cysteine/homocysteine (Cys/Hcy) has been developed. In the presence of Cys/Hcy, this probe was transformed into 1,3-bis(bispyridin-2ylimino)isoindolin-4-ol (dye 4) which displayed red fluorescence with a large Stokes shift (217 nm) when excited. The detection limits are as low as 5.4 nM and 7.0 nM for Cys and Hcy respectively (based on S/N = 3). Importantly, this probe has been successfully demonstrated for the detection of intracellular Cys/Hcy in living cells.  相似文献   

4.
A highly selective dual-channel NIR fl uorescent probe (DFB1) based on curcuminoid difl uoroboron is developed for discrimination Cys over GSH, Hcy and other amino acids in mitochondria of living cells.  相似文献   

5.
The specific detection of cysteine (Cys) over homocysteine (Hcy), glutathione (GSH) and other amino acids is of great significance for studying its biological functions as well as for the diagnosis of related diseases. Chloroacetyl group was often used as a reaction site for cysteine fluorescent probes for its sensitivity and selectivity. However, high background fluorescence and low stability are common problems encountered by such probes. Here, four chloroacetyl group based fluorescent probes (C1, C2, C3, and H4) was synthesized for a comparative study. We found that the inefficient quenching ability of chloroacetyl group turned into an advantage when connected with a ratiometric fluorophore. With the modification of chloroacetyl group, probe H4 displayed excellent ratiometric property and great selectivity for Cys, the stability was also improved. Additionally, the probe was successfully applied for quantitative detection of Cys in fetal bovine serum and real-time imaging in living HeLa cells with low toxicity.  相似文献   

6.
A novel class of curcumin-derived fluorescent probes was designed. This kind of probe introduces easy leaving groups methylsulfonyl and phenylsulfonyl respectively to achieve the detection effect through the nucleophilic attack of amino acids. At the same time, BF2 group is introduced to increase the emission wavelength of the probe. Probes 4 and 5 can respond quickly with amino acids, but can specifically recognize Cys. In UV detection, the maximum absorption wavelength of the probes can be blue-shifted by 81 nm with the addition of Cys and still show a strong fluorescence signal. The detection limits for compounds 4 and 5 were determined to be 0.40 μM and 0.87 μM, respectively, with a goodness-of-fit of 0.99. In addition, a rapid response of the probe to Cys could be observed with the naked eye within 1 min. These results provide a new method for rapid detection of Cys; And this kind of probe has the drug structure of curcumin, which can provide ideas for the design of drug-probe.  相似文献   

7.
We synthesized a new coumarin-based probe TP, containing a disulfide moiety, to detect biothiols in cells. A fluorescence turn-on response is induced by the thiol–disulfide exchange of the probe, with subsequent intramolecular benzothiazolidine ring formation giving rise to a fluorescent product. The probe exhibits an excellent selectivity for cysteine (Cys) and homocysteine (Hcy) over glutathione (GSH) and other amino acids. The fluorescent probe also exhibits a highly sensitive fluorescence turn-on response to Cys and Hcy with detection limits of 0.8 μM for Cys and 0.5 μM for Hcy. In addition, confocal fluorescence microscopy imaging using RAW264.7 macrophages demonstrates that the probe TP could be an efficient fluorescent detector for thiols in living cells.  相似文献   

8.
A new Excited-State Intramolecular Proton Transfer (ESIPT) based fluorescent probe for the detection of Hg2+ has been rationally designed and developed. Based on the specific reactivity of mercury-promoted hydrolysis, the probe exhibits high selectivity and sensitivity for mercury ions in almost pure aqueous solution (containing only 1% DMSO) with a low detection limit of 1.9?ppb. Furthermore, the probe was also successfully used for fluorescence imaging of Hg2+ in live cells.  相似文献   

9.
A naphthofluorescein-based fluorescent probe with two independent reaction sites (nitro-2,1,3-benzoxadiazole and acrylate moiety) was developed. Integrating these two reaction sites into a single molecule not only can guarantee the selective detection of Cys/Hcy in an elegant fashion, but also can enable Cys/Hcy detection in a multiple-channel responsive manner.  相似文献   

10.
We designed and synthesized a series of BODIPY based probes with fast and distinct ratiometric responsiveness for discriminative detection of GSH from Cys and Hcy. The discriminative detection is based on the different products obtained by the SNAr between probes and thiol-containing amino acids. The amino group of the obtained thioether from the reaction with Cys or Hcy but not GSH would trigger an intramolecular nucleophilic substitution through five- or six-membered cyclic transition state, finally yielding an amino substituted derivative. To achieve highly discriminative detection and fast response, a series of structure modifications and improvements have been made by elongating the π-conjugation and introducing electron withdrawing groups, finally affording probe BOD-DBNPF with optimized responsiveness and selectivity. Importantly, BOD-DBNPF was successfully used for the selective detection of GSH from Cys with distinct fluorescent ratiometric responses in living HeLa cells.  相似文献   

11.
基于1,8-萘酰亚胺衍生物,构建了一种检测半胱氨酸(Cys)的新型荧光探针TPFC-Acryloyl。光谱研究表明该探针能有效识别Cys且能够在1min内实现快速响应。探针对Cys的检测表现出高选择性,检测限为2.13μmol/L。经荧光光谱和质谱实验确证其检测机理为:Cys与TPFC-Acryloyl分子中的丙烯酸酯发生共轭加成-环化反应,进而羟基裸露的同时释放出黄色荧光。细胞毒性测试表明探针TPFC-Acryloyl的细胞毒性低。此外,该探针还被成功应用于活细胞和秀丽隐杆线虫中Cys的荧光成像。  相似文献   

12.
合成了以4-羟基萘酰亚胺为荧光团,2,4-二硝基苯磺酰氧基为特异性识别基团的生物硫醇探针4-(2,4-二硝基苯磺酰氧基)-正丁基-1,8-萘酰亚胺(DNSBN).吸收光谱和荧光光谱结果表明, DNSBN对半胱氨酸(Cys)、同型半胱氨酸(Hcy)和谷胱甘肽(GSH)3种生物硫醇分子具有高效的检测识别能力,不受其它17种天然氨基酸的干扰.同时,通过荧光滴定实验证实了此探针是一种比率型探针,555 nm处的荧光强度与溶液中的生物硫醇分子浓度在0 ~ 20 μmol/L范围内呈良好的线性关系,对Cys、Hcy和GSH的检出限(3σ)分别为25.9、92.0和77.9 nmol/L.而吸收光谱、荧光光谱和质谱表征数据显示,生物硫醇与2,4-二硝基苯磺酸酯发生亲核取代反应并导致磺酸酯的分解.随着识别基团的解离,探针分子的d-PeT (donor-excited photoinduced electron transfer) 效应被解除,并出现非常明显的比色与荧光变化.HeLa细胞成像实验表明,探针DNSBN具有良好的生物相容性,能够对细胞外源性生物硫醇分子进行检测.  相似文献   

13.
This study reports an activatable iridium(III) complex probe for phosphorescence/time-gated luminescence detection of cysteine (Cys) in vitro and in vivo. The probe, [Ir(ppy)2(NTY-bpy)](PF6) [ppy: 2-phenylpyridine; NTY-bpy: 4-methyl-4′-(2-nitrovinyl)-2,2′-bipyridine], is developed by incorporating a strong electron-withdrawing group, nitroolefin, into a bipyridine ligand of the IrIII complex. The luminescence of the probe is quenched owing to the intramolecular charge transfer (ICT) process, but switched on by a specific recognition reaction between the probe and Cys. [Ir(ppy)2(NTY-bpy)](PF6) shows high sensitivity and selectivity for Cys detection and good biocompatibility. The long-lived emission of [Ir(ppy)2(NTY-bpy)](PF6) allows time-gated luminescence analysis of Cys in cells and human sera. These properties make it convenient for the phosphorescence and time-gated luminescence imaging and flow cytometry analysis of Cys in live samples. The Cys images in cancer cells and inflamed macrophage cells reveal that [Ir(ppy)2(NTY-bpy)](PF6) is distributed in mitochondria after cellular internalization. Visualizations and flow cytometry analysis of mitochondrial Cys levels and Cys-mediated redox activities of live cells are achieved. By using [Ir(ppy)2(NTY-bpy)](PF6) as a probe, in vivo sensing and imaging of Cys in D. magna, zebrafish, and mice are then demonstrated.  相似文献   

14.
A new fl uorescent probe 1 was designed for mitochondrial localization and ratiometric detection of hypochlorite in living cells. It is noteworthy that a high Pearson’s co-localization coeffi cient (Rr) we have obtained was calculated to be 0.97.  相似文献   

15.
A dual-site fluorescent probe that could discriminatively respond to Cys and HSO3- through two emission channels was reported, and it could further applied in imaging biothiols in living cells.  相似文献   

16.
A highly water soluble fluorescent probe was developed for sensitive and selective detection of biothiols with a red emission and a large Stokes shift. The probe was successfully applied to detect biothiols both in aqueous solution and in living cells.  相似文献   

17.
A turn-on fluorescent probe, based on a water-soluble terphenyl derivative, for the detection of cysteine and homocysteine is reported. The aldehyde groups in the probe play crucial roles in providing reaction with thiol groups in the amino acids, leading to a formation of thiazolidine (from cysteine) or thiazinane ring (from homocysteine). As a result, the new formation of such rings alters the electronic property of the conjugated system in the probe and results in emission enhancement. The probe in aqueous solution exhibits a remarkable increase in its quantum yield upon exposure to cysteine (up to 20-fold) and to homocysteine (up to 700-fold), while slight quenching is observed in the presence of glutathione. Moreover, an investigation on time-resolved fluorescence spectra of the probe in the presence of cysteine and homocysteine reveals potential discriminatory detection of cysteine and homocysteine. Bioimaging of the thiols in live HeLa cells was successfully applied.  相似文献   

18.
Differentiation of biologically important thiols, such as cysteine (Cys), homocysteine (Hcy), and glutathione (GSH) is still a challenging task. Herein, we present a novel fluorescent chemodosimeter capable of selectively detecting Cys over other biothiols including Hcy and GSH and other amino acids by a facile thiol‐Michael addition/transcyclization rearrangement cascade click process. The unique transcyclization step is critical for the selectivity as a result of the kinetically favorable formation of a six‐membered ring with the Cys Michael adduct. Moreover, the probe adopts a distinctive dual quenching mechanism—photoinduced electron transfer (PET) and photoinduced intramolecular charge transfer (ICT) to deliver a drastic turn‐on fluorescence response only at the Cys‐selective transcylization step. The judicious selection of strong electron‐withdrawing naphthalimide fluorophore with maleimide group enhances the electrophilicity and thus reactivity for the cascade process leading to fast detection and ultrasensitivity with a detection limit of 2.0 nm (S/N=3). The probe has demonstrated its practical utility potential in Cys imaging in live cells.  相似文献   

19.
Homocysteine(Hcy), cysteine(Cys) and glutathione(GSH) play crucial roles in redox homeostasis during mitochondria functions. Simultaneous differentiation and visualization of mitochondrial biothiols dynamics are significant for understanding cell metabolism and their related diseases. Herein, a multisitebinding fluorescent probe(MCP) was developed for simultaneous sensing of mitochondrial Cys, GSH and Hcy from three fluorescence channels for the first time. This novel probe exhibited rapid fluor...  相似文献   

20.
《Arabian Journal of Chemistry》2020,13(12):8697-8707
A dipodal fluorescent probe 3, with imine and hydroxyl moieties as binding sites, has been synthesized and characterized with spectroscopic methods, single-crystal X-ray techniques, and DFT. The synthesized probe 3 (φ = 0.0028) showed highly sensitive and highly specific fluorescent ‘turn-on’ effect (λem = 453 nm) for the 1:1 binding with Fe3+ ions to form probe 3.Fe3+ complex (φ = 0.203) in semi-aqueous medium (acetonitrile:water (50:50; v/v)) and live cells. The 1:1 binding stoichiometry of probe 3 and Fe3+ ions was proposed by DFT calculations and confirmed by the NMR spectroscopy, crystal structures of probe 3 and 3.Fe3+ complex, and mass spectrum of probe 3.Fe3+ complex. The stability of probe 3.Fe3+ complex in a wide pH range (pH 2–12) and reversibility for binding with Fe3+ ions in the presence of EDTA indicates that it can be an effective chemosensor for the detection of Fe3+ ions in various samples, including living cells. Importantly, with the LOD of 21.5 nM for the detection of Fe3+ ions, probe 3 did not show any interference from potentially competing ions even at a 1:3 ratio, indicates its biocompatibility. The nanomolar limit of detection (21.5 nM), cell permeability, and low cytotoxicity allows the probe 3 to be an excellent tool for the live-cell imaging and detection of ferric ions in live cells.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号