首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
With the aid of a central composite face-centered design, an ion chromatographic method was developed and optimized for analyzing organic acids in tobacco. A Dionex-100 ion chromatograph with an ion suppressor and a conductivity detector, and a Bio-Rad Aminex HPX-87H column were employed. Only 13 analyses were required to optimize two factors: column temperature and eluent strength. Two sets of optimal conditions for separating nine acids were found: 1.8 mM HFBA eluent and 42 °C column temperature, and 0.8 mM HFBA eluent and 50 °C column temperature. The flow-rate was 0.6 ml min−1 and the analysis time was 18 min or less. A sample preparation procedure included extraction of 2 g ground tobacco with 100 ml of 5 mM sulfuric acid solution for 3 h, filtration of the extract, and dilution of the filtrate 10-fold with deionized water.  相似文献   

2.
Jiang M  Qin F  Xiong Z  Zhang S  Pan L  Li F 《色谱》2011,29(11):1137-1140
以纤维素三-(3,5-二甲基苯基氨基甲酸酯)为手性固定相(Lux Cellulose-1),建立了在正相色谱条件下直接分离盐酸川丁特罗对映体的高效液相色谱法。考察了乙醇、异丙醇等有机改性剂,三氟乙酸、二乙胺等流动相添加剂和柱温对对映体分离的影响。结果显示,酸性和碱性添加剂对对映体分离的影响最为显著: 添加二乙胺时两对映体无分离趋势;添加三氟乙酸时对映体保留强,且分离趋势明显;而同时添加三氟乙酸和二乙胺则两对映体分离显著改善,分离度可达4.0。优化后的色谱条件: 色谱柱为Lux Cellulose-1手性柱(250 mm×4.6 mm, 5 μm),流动相为正庚烷-乙醇-三氟乙酸-二乙胺(88:12:0.3:0.05, v/v/v/v),流速为1.0 mL/min,紫外检测波长为246 nm,柱温为25 ℃。该方法简便,快速,可用于左旋盐酸川丁特罗原料中右旋异构体杂质的检查。  相似文献   

3.
Aqueous sulfuric acid can be used as the mobile phase in cation ion chromatography to separate the three biogenic amines, putrescine, cadaverine, and histamine, from fish. Various concentrations of aqueous sulfuric acid were investigated to optimize the separation of these three biogenic amines. Aqueous sulfuric acid (5.0 mM) was found to be optimum for the separation and was used to determine the three biogenic amines in fish. The LOQ, defined as the lowest level of the standard calibration curve, was 0.055 ppm (equivalent to 0.55 microg/g sample) for putrescine, 0.05 ppm (equivalent to 0.5 microg/g sample) for cadaverine, and 1.0 ppm (equivalent to 10 microg/g sample) for histamine. From statistical analysis of the LOQ, the method detection limit was 0.003 ppm for putrescine, 0.009 ppm for cadaverine, and 0.16 ppm for histamine. For sample preparation, the fish was composited, homogenized in methanol-water (75 + 25, v/v), incubated for 15 min at 60 degrees C, and centrifuged. The sample solution was micron-filtered before injection. The mobile phase flow rate was 0.8 mL/min under isocratic conditions at room temperature (15-25 degrees C). The three biogenic amines were separated in the order of increasing retention time, i.e., putrescine, cadaverine, and histamine, within 30 min. The chromatograms showed complete peak separation of the three amines regardless of the difference in fish matrixes.  相似文献   

4.
范顺利  张立科  魏彦林  林金明 《色谱》2006,24(2):148-151
基于酸性介质中甲酸对高锰酸钾-苯二酚氧化发光反应的增敏作用建立了高效液相色谱-化学发光柱后检测苯二酚的新方法。优化了高锰酸钾-苯二酚氧化发光反应及高效液相色谱分离苯二酚的条件,用甲醇-0.1 mmol/L β-环糊精水溶液(体积比为30∶70) 作为流动相可实现对水中3种苯二酚异构体的分离,且能与高锰酸钾-苯二酚氧化化学发光反应条件很好地偶合。对所测定的苯二酚异构体,方法的线性范围达两个数量级;以信噪比为3测得邻、间、对苯二酚的检出限(n=3)分别为:5.2,4.7,3.2 μg/L,对质量浓度均为0.10 mg/L的3种苯二酚混合溶液连续测定11次,邻、间、对苯二酚的相对标准偏差分别为2.8%,3.4%,6.5%。将该方法与固相萃取技术相结合,对河水中的痕量苯二酚进行了测定,加标回收率为92.1%~95.4%。  相似文献   

5.
A rapid, simple and sensitive high-performance liquid chromatography method for the quantification of gambogic acid in dog plasma was developed and validated. After acidification with hydrochloric acid, dog plasma was extracted with ethyl acetate and determined by HPLC. The analysis was carried out on a reversed-phase C(18) analytical column. The mobile phase consisted of a mixture of methanol-0.05% phosphoric acid (94:6, v/v), and the column temperature was maintained at 35 degrees C. A constant mobile phase flow rate of 1.0 mL/min was employed throughout the analyses. The ultraviolet detector was set at 360 nm. Chromatographic separation was achieved in less than 10 min and the calibration curve was linear over a concentration range of 0.156-20 microg/mL. The intra-assay and inter-assay variability values were less than 10.0%. The accuracy ranged from 93.0 to 104.2%. The established method has been successfully applied to a pharmacokinetic study of gambogic acid in dogs.  相似文献   

6.
Experimental conditions for complete separation and quantification of mixtures containing lactobionic acid, sorbitol, lactose and fructose are discussed for the first time. These mixtures appear in the enzymatic bioconversion of fructose and lactose catalyzed by glucose-fructose oxidoreductase (GFOR) and glucono-delta-lactonase (GL) enzymes of Zymomonas mobilis cells. The high-performance liquid chromatography (HPLC) separation was carried out in a strong cation ion exchange resin (hydrogen form) based on a copolymer of styrene divinylbenzene (PS-DVB). A stationary phase of beta-cyclodextrin was also evaluated. An efficient separation was obtained with PS-DVB column eluted with sulfuric acid 0.450 mM solutions (pH 3.0-3.2) at 75 degrees C. The formation of lactones was observed, which is associated with the dissolution of lactobionic acid crystals; however, by dissolving the lactobionic acid crystals on alkaline calcium hydroxyde solution in equimolar ratio a single lactobionic acid chromatographic peak without lactobionolactone is obtained.  相似文献   

7.
将C18柱与手性冠醚柱串联,建立了一种反相高效液相色谱法用于3种芳香族氨基酸对映体同时拆分的方法.考察了反相色谱流动相的组成、pH值、柱温、流速对对映体拆分的影响.实验结果表明,当流动相为HClO4-乙睛溶液(86:14,V/V,pH 2.0)、柱温20℃、流速0.4 mL/min时,3种氨基酸对映体可获得基线分离.进一步对比了C18柱、冠醚手性柱和串联顺序不同的4种分离模式,结果表明,C18柱不能拆分氨基酸对映体,仅能分离不同种类氨基酸;冠醚手性柱可分离氨基酸映体,但不同种类氨基酸色谱峰出现重叠;串联模式能实现3种氨基酸对映体的基线分离,实现双柱优势互补,而串联顺序对分离影响不大,仅影响色谱峰的峰形.  相似文献   

8.
2-(2,3-anthracenedicarboximido)cyclohexane derivatives (AC) have been known as the evolutionary diastereomerizing reagents for enantiomer discrimination in HPLC with ODS. However, a substantial separation of diastereomers can be observed only at lower temperatures, such as -40 degrees C. Therefore, in this work, poly(octadecyl acrylate)-grafted silica, ODAn was applied as an alternative stationary phase to ODS for the separation of AC-derived diastereomers. As a result, complete separation was achieved even under the conventional condition: for example, methanol as the mobile phase and 0 degrees C as the column temperature. An investigation on the temperature dependency of the selectivity demonstrated that ODAn shows a remarkable increase in selectivity at temperatures below 30 degrees C, which almost agreed with the peak-top temperature of the endothermic peak in a DSC thermogram for ODA35 immersed in a mobile phase. The better separation would be derived from a highly ordered structure of ODAn and a carbonyl-pi interaction with AC-derived diastereomers.  相似文献   

9.
Thermostated micro planar chromatography was applied for systematic separation studies of C60 and C70 fullerenes using n-alkanes as mobile phases on TLC and HPTLC plates coated with polyamide, silica gel, aluminum oxide as well as two types of octadecylsilica (C18) sorbents. Retention data were collected at constant temperature at 20 degrees C (+/-0.05 degrees C) using an unsaturated chamber mode with an eluent, such as n-pentane, n-hexane and n-heptane. The separation results under both saturated and unsaturated chamber modes for selected mobile/stationary phases were also examined, and several parameters, including separation factor (alpha) and resolution (R(S)), were compared with data obtained with high-performance liquid chromatography conditions. Interestingly, C60/C70 fullerenes separation performed on HPTLC plates with a developing distance of 45 mm was better for those observed on a 25 cm length analytical HPLC column under similar conditions to that on carbon coverage of the stationary phase, n-hexane as the mobile phase and separation temperature (R(S) = 1.84 and 1.68 for HPTLC, and HPLC, respectively). Moreover the advantage of the planar chromatographic separation of fullerenes studied is a short elution time of less than 6 min. Furthermore, the reported separation protocol shows a capability for the evaluation of fullerenes quantity in commercial samples.  相似文献   

10.
A polymeric ODS column was applied to the resolution of triacylglycerol positional isomers (TAG-PI), i.e. 1,3-dioleoyl-2-palmitoyl-glycerol (OPO) and 1,2-dioleoyl-3-palmitoyl-rac-glycerol (OOP), with a recycle HPLC system. To investigate the ODS column species and the column temperatures for the resolution of a TAG-PI pair, a mixture of OPO and OOP was subjected to an HPLC system equipped with a non-endcapped polymeric, endcapped monomeric, endcapped intermediate, or non-endcapped monomeric ODS column at three different column temperatures (40, 25, or 10 degrees C). Only the non-endcapped polymeric ODS column achieved the separation of OPO and OOP, and the lowest column temperature (10 degrees C) showed the best resolution for them. The other pair of TAG-PI, a mixture of 1,3-dipalmitoyl-2-oleoyl-glycerol (POP) and 1,2-dipalmitoyl-3-oleoyl-rac-glycerol (PPO) was also subjected to the system equipped with a non-endcapped polymeric or monomeric ODS column at five different column temperatures (40, 32, 25, 17, and 10 degrees C). Thus, POP and PPO were also separated on only the non-endcapped polymeric ODS column at 25 degrees C. However, no clear peak appeared at 10 degrees C. These results would indicate that the polymeric ODS stationary phase has an ability to recognize the structural differences between TAG-PI pairs. Also, the column temperature is a very important factor for separating the TAG-PI pair, and the optimal temperature would relate to the solubility of TAG-PI in the mobile phase. Furthermore, the recycle HPLC system provided measurements for the separation and analysis of TAG-PI pairs.  相似文献   

11.
Abstract

A reversed-phase, isocratic HPLC method has been developed for the quantitation of desipramine in human plasma. the method involved the use of cloimpramine as an internal standard. the chromatographic separation was accomplished with a mobile phase comprising acetonitrile-aqueous solution (60:40. v/v) containing 10 mM disodium hydrogenphosphate and 80 mM sodium dodecyl sulfate adjusted to pH 2. the mobile phase was pumped at a flow rate of 0.5 ml/min. the column used was a microbore column (2 mm I.D. × 100 mm) packed with a C18 reversed-phase material (5μm ODS Hypersil). Plasma samples were extracted at basic pH with diethyl ether followed by back-extraction into 0.1 N sulfuric acid. Using UV detection at 250 nm, the lower limit of sensitivity was 10 ng/ml. the inter- and intra-assay coefficients of variation were found to be less than 10%. the assay procedure was applied to a long term oral dosing study in patients to monitor the plasma concentration of desipramine.  相似文献   

12.
黄翼飞  胡静 《色谱》2010,28(6):615-622
建立了液相色谱-电喷雾离子阱串联质谱(LC-ESI-IT-MS/MS)同时分析烟草中20种游离氨基酸的方法。烟草样品经萃取后过滤直接进样,无需进行衍生和固相萃取等其他前处理步骤。液相色谱采用HyPURITY C18反相色谱柱(200 mm×2.1 mm, 5 μm),采用1%(体积分数,下同)乙腈水溶液(含0.1%九氟戊酸)和90%乙腈水溶液(含0.1%九氟戊酸)为流动相进行梯度洗脱。结果表明,20种氨基酸的检出限(LOD)为0.01~0.05 μmol/L (S/N=3),线性相关系数均大于0.9977,峰面积测定的相对标准偏差(RSD)为0.78%~4.93%。该方法分析效率、灵敏度和选择性高,已成功应用于多种烟草样品中氨基酸的分析测定。  相似文献   

13.
A classical kinetic method was used to determine the energy barrier for the inter-conversion of 2,3-pentadienedioic acid enantiomers. Each individual enantiomer was isolated by collecting the appropriate peaks from the HPLC enantiomeric separation, of racemic 2,3-pentadienedioic acid. The isolated enantiomers were racemized at 22 degrees C using various interconversion times. The ratio of enantiomers in each reaction solution was determined by HPLC at 22 degrees C. The corresponding peak areas of the enantiomers and the interconversion times obtained from the HPLC chromatograms were used to calculate both the interconversion rate constants describing (+)--> (-) and (-) --> (+) interconversions as well as the energy barriers. It was confirmed that the interconversion of 2,3-pentadienedioic acid enantiomers is a firstorder kinetic reaction. Both semiempirical and ab initio methods were used to explore the mechanism of the interconversion of 2,3-pentadienedioic acid enantiomers, and to calculate the interconversion energy barrier. Comparison of the interconversion energy barriers found by the ab initio method (deltaG# = 110.7 kJ/mol) and by classical kinetics in the mobile phase solution at 22 degrees C (delta Gapp = 93.9+/-0.2 kJ/mol) shows a difference which may be attributed to the different conditions assumed in the theoretical calculation (i.e., a gaseous state) and the actual experimental conditions (i. e., liquid solution) and a possible catalytic effect of the solution composition.  相似文献   

14.
This paper reports the first integrated microelectromechanical system (MEMS) HPLC chip that consists of a parylene high-pressure LC column, an electrochemical sensor, a resistive heater and a thermal-isolation structure for on-chip temperature gradient interaction chromatography application. The separation column was 8 mm long, 100 microm wide, 25 microm high and was packed with 5 microm sized, C18-coated beads using conventional slurry-packing technique. A novel parylene-enhanced, air-gap thermal isolation technology was used to reduce heater power consumption by 58% and to reduce temperature rise in the off-column area by 67%. The fabricated chip consumed 400 mW when operated at 100 degrees C. To test the chromatography performance of the fabricated system, a mixture of derivatized amino acids was chosen for separation. A temporal temperature gradient scanning from 25 to 65 degrees C with a ramping rate of 3.6 degrees C/min was applied to the column during separation. Successful chromatographic separation of derivatized amino acids was carried out using our chip. Compared with conventional temperature gradient HPLC system which incorporates "macro oven" to generate temporal temperature gradient on the column, our chip's thermal performance, i.e., power consumption and thermal response, is greatly improved without sacrificing chromatography quality.  相似文献   

15.
This study presents a new HPLC method using evaporative light scattering detection for the simultaneous determination of live major iridoid glucosides, namely 7-epi-loganin, sweroside, loganin, 7-epi-vogeloside, and secoxyloganin in Flos Lonicerae, an important traditional Chinese medicinal herb. The optimal conditions of separation and detection were achieved on a C18 analytical column with an isocratic mobile phase consisting of methanol-water (30:70, v/v) containing 0.5% acetic acid at the flow-rate of 1.0 ml/min, temperature for the detector drift tube set at 90 degrees C and the nitrogen flow-rate of 2.6 l/min. The limit of detection (S/N = 3) is less than 35.1 microg/ml and the limit of quantification (S/N = 10) is less than 140.1 microg/ml. All calibration curves show good linear regression (r2>0.996) within test ranges. This method provides good reproducibility for the quantification of the major iridoid glucosides in four Lonicera species with overall intra- and inter-day variation of less than 5% and 9%, respectively. The assay was successfully applied to quantify the main iridoid glucosides in the herb and to identify the botanical origin of Flos Lonicerae.  相似文献   

16.
High-performance liquid chromatographic (HPLC) separation of stereomeric cyclic beta-substituted or-quaternary alpha-amino acids was performed on a chiral stationary phase based on the glycopeptide antibiotic teicoplanin. The investigated amino acids are the 1-amino-2-methylcyclohexanecarboxylic acids, the 1-amino-2-hydroxycyclohexanecarboxylic acids, Ala, Cha, Phe and Tle. The effects of the mobile phase composition (type and content of organic modifier, pH) and of the temperature on the enantio- and diastereoselectivity were studied and the conditions were optimised to resolve the four stereomers of one amino acid in a single chromatographic run. The influence of the modifier concentration and the pH of the mobile phase reveal two enantiomeric and diastereomeric discrimination mechanisms based on different interactions with the stationary phase. For optimal separation of diastereomers the column has to be conditioned with an acidic eluent.  相似文献   

17.
A new and simple approach is described for the determination of the haloacetic acids (such as mono-, di- and trichloroacetic acids) usually found in drinking water as chlorination by-products after disinfection processes and acetic acid. The new approach, termed vacancy ion-exclusion chromatography, is based on an ion-exclusion mechanism but using the sample solution as the mobile phase, pure water as the injected sample, and a weakly acidic cation-exchange resin column (TSKgel OApak-A) as the stationary phase. The addition of sulfuric acid to the mobile phase results in highly sensitive conductivity detection with sharp and well-shaped peaks, leading to excellent and efficient separations. The elution order was sulfuric acid, dichloroacetic acid, monochloroacetic acid, trichloroacetic acid, and acetic acid. The separation of these acids depends on their pKa values. Acids with lower pKa values were eluted earlier than those with higher pKa, except for trichloroacetic acid due to a hydrophobic-adsorption effect occurring as a side-effect of vacancy ion-exclusion chromatography. The detection limits of these acids in the present study with conductivity detection were 3.4 microM for monochloroacetic acid, 0.86 microM for dichloroacetic acid and 0.15 microM for trichloroacetic acid.  相似文献   

18.
刘惠文 《色谱》1999,17(4):410-412
使用强阳离子交换柱分离、pH梯度洗脱、柱后衍生、荧光λex=338nm和λem=425nm检测的高效液相色谱法,成功地分析了药用植物铃兰中的吖丁啶-2-羧酸,方法回收率为96.4%。  相似文献   

19.
The chromatographic performance of the Dionex IonPac ICE-AS6 ion exclusion column is investigated. Therefore, capacity factors, efficiency, peak symmetry, resolution, and selectivity are determined for various mono- and polyfunctional aliphatic carboxylic acids under selected chromatographic conditions. Except for the stronger acids (pKa1 < 3.75), the highest chromatographic efficiency is achieved at a column temperature of 40 or 50 degrees C, and peak shape is found to be optimal at approximately 60 degrees C. The separation of the stronger acids is favored by an eluent pH below 3.0 and column temperatures below 40 degrees C. The maximal effective plate numbers range between 126 (tartronic acid) and 6380 (4-oxovaleric acid). Hydroxy-substituted acids are less retained and less influenced by temperature changes than the unsubstituted compounds. It is estimated that size exclusion effects take part in the separation of aldonic acids. The addition of 1% isopropanol to the acidic eluent increases the chromatographic efficiency generally, whereas higher concentrations reduce the retention of several acids drastically.  相似文献   

20.
A simple, sensitive, specific and reproducible method for the determination of corticosterone concentrations in rat serum using high-performance liquid chromatography (HPLC) with fluorimetric detection is described. Corticosterone is detectable down to 0.1 ng injected onto the HPLC column. Cortisol is used as an internal standard. Ethyl acetate was used for both initial serum corticosteroid extraction and the subsequent fluorophore extraction after sulfuric acid hydrolysis; thus sulfuric acid does not enter the HPLC system. The resultant fluorophores for both corticosterone and cortisol are stable for at least two weeks at ambient temperature not requiring storage at -20 degrees C. The procedure is highly suitable for use with HPLC systems utilising automatic sample injectors. The method is specific for corticosterone; dexamethasone, cortisone and gonadal steroids are not detectable and do not interfere in this assay.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号