首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel ion-exchange system was developed by tethering a small, monofunctional metal ligand, 3-mercaptopropionic acid (MPA), through thiol linkages onto a glass substrate overlaid with gold, using electroless deposition of Au onto 100 mesh controlled pore glass (CPG) particles. Two different CPG glass pore sizes of 22.6 and 104.9 nm were used in an attempt to optimize Au deposition and ligand coverage. It was found that the Au was present on both of the substrates as a nonuniform deposit, possibly existing as small multilayer islands, throughout the CPG particles. The deposit also did not fill the intricate CPG pore network.Au-CPG is a reasonable substrate for the support of small metal binding ligands such as the monofunctional MPA. Typical metal binding capacities were in the range of 7-24 μmol metal/g column, with the smaller pore system binding approximately twice as much metal as the larger pore system due to increased surface area and fractional ligand coverage. The immobilized binding systems were also found to remain chemically and structurally stable in pH environments ranging from pH∼9 to <1 (viz. 1 M HNO3).  相似文献   

2.
The influence of the carrier matrix depth was investigated for porous silicon enzyme reactors. For the experiments, <110> oriented silicon, p-type (20–70?Ω?cm), was used. Porous silicon was generated on planar surfaces and on anisotropically pre-etched high aspect-ratio parallel channel reactors. For each type of sample the porous silicon layer was generated for three depths, controlled by the anodisation time, and two current densities, to yield different morphologies. Glucose oxidase (GOx) was immobilised on the porous matrix by standard procedures for immobilisation of enzymes on silica. The enzyme activity of the samples was monitored by a colorimetric assay. The results clearly display the influence of the matrix depth for both the planar and the reactor structures. A 170-fold increase in catalytic turn-over, in comparison to an identical non-porous reference, was recorded for a reactor with an average pore depth of 10?μm. At depths above 10?μm the increase in catalytic efficiency levelled off. For the planar samples the levelling off occurred at an average pore depth of 20?μm.  相似文献   

3.
A microfluidic device was designed for amperometric determination of glucose by packing enzyme modified magnetic nanoparticles (MNPs) in its microchannel as an enzyme microreactor. Glucose oxidase was covalently attached to the surface of MNPs and localized in the microchannel by the help of an external magnetic field, leading to a tunable packing length. By changing the length of microreactor from 3 to 10 mm, the performance for glucose detection was optimized. The optimal linear range to glucose was from 25 μM to 15 mM with a detection limit of 11 μM at a length of 6 mm. The inter- and intra-day precisions for determination of 1.0 mM glucose were 0.8% and 1.7%, respectively, and the device-to-device reproducibility was 95.6%. The enzyme reactor remained its 81% activity after three-week storage. Due to the advantages of the device and fracture sampling technique, serum samples could be directly sampled through the fracture to achieve baseline separation from ascorbic acid, and proteins in the samples did not interfere with the detection. This work provided a promising way for pretreatment-free determination of glucose with low cost and excellent performance.  相似文献   

4.
A study was undertaken to evaluate Saccharomyces cerevisiae as a substrate for the biosorption of Cr(III) and Cr(VI) aiming to the selective determination of these species in aqueous solutions. The yeast cells were covalently immobilised on controlled pore glass (CPG), packed in a minicolumn and incorporated in an on-line flow injection system. The effect of chemical and physical variables affecting the biosorption process was tested in order to select the optimal analytical conditions for the Cr retention by S. cerevisiae. Cr(III) was retained by the immobilised cells and Cr(VI) were retained by CPG. The speciation was possible by selective and sequential elution of Cr(III) with 0.05 mol L−1 HCl and 2.0 mol L−1 HNO3 for Cr(VI). The influence of some concomitant ions up to 20 mg L−1 was also tested. Quantitative determinations of Cr were carried out by means of inductively coupled plasma optical emission spectrometry (ICP OES). Preconcentration factors of 12 were achieved for Cr(III) and 5 for Cr(VI) when 1.7 mL of sample were processed reaching detection limits of 0.45 for Cr(III) and 1.5 μg L−1 for Cr(VI). The speciation of inorganic Cr in different kinds of natural waters was performed following the proposed method. Spiked water samples were also analysed and the recoveries were in all cases between 81 and 103%.  相似文献   

5.
The immobilization conditions and kinetic behaviour of trypsin, covalently immobilized via the 1,4-diisothiocyanatobenzene (DITC) linker onto aminopropylated controlled pore glass (CPG) particles, have been evaluated to establish a rapid and efficient protocol for fabrication of an immobilized enzyme microreactor (IMER) for protein hydrolysis and subsequent peptide mapping. Addition of calcium ions to either the immobilization reaction solution or hydrolysis assay was studied for a synthetic substrate. Activity was slightly higher when immobilization was carried out in the presence of Ca2+ whereas more enzyme could be immobilized in its absence. A protocol requiring less than 3 h was devised to obtain maximal enzymatic activity with the lowest ratio of soluble trypsin to DITC-CPG particles. The resulting immobilized enzyme was found to retain an acceptable percentage (ca. 35%) of its activity after immobilization. The particles were dry-packed into a capillary to make a microscale IMER. Repeatability, reusability and digestion efficiency of the μIMER were investigated for the substrate β-casein using capillary electrophoretic-based peptide mapping. In initial tests, a single device showed reproducible peptide maps for 21 digestions lasting 2 h each, carried out over a period of 2 months. Complete digestion of β-casein could be achieved in a few minutes (86 s residence time in the μIMER followed by a wash step).  相似文献   

6.
Electroactive nanostructured membranes have been produced by the layer-by-layer (LbL) technique, and used to make electrochemical enzyme biosensors for glucose by modification with cobalt hexacyanoferrate redox mediator and immobilisation of glucose oxidase enzyme. Indium tin oxide (ITO) glass electrodes were modified with up to three bilayers of polyamidoamine (PAMAM) dendrimers containing gold nanoparticles and poly(vinylsulfonate) (PVS). The gold nanoparticles were covered with cobalt hexacyanoferrate that functioned as a redox mediator, allowing the modified electrode to be used to detect H2O2, the product of the oxidase enzymatic reaction, at 0.0 V vs. SCE. Enzyme was then immobilised by cross-linking with glutaraldehyde. Several parameters for optimisation of the glucose biosensor were investigated, including the number of deposited bilayers, the enzyme immobilisation protocol and the concentrations of immobilised enzyme and of the protein that was crosslinked with PAMAM. The latter was used to provide glucose oxidase with a friendly environment, in order to preserve its bioactivity. The optimised biosensor, with three bilayers, has high sensitivity and operational stability, with a detection limit of 6.1 μM and an apparent Michaelis–Menten constant of 0.20 mM. It showed good selectivity against interferents and is suitable for glucose measurements in natural samples.  相似文献   

7.
We report the development of a microfabricated gas chromatography system suitable for the separation of volatile organic compounds (VOCs) and compatible with use as a portable measurement device. Hydrofluoric acid etching of 95 × 95 mm Schott B270 wafers has been used to give symmetrical hemi-spherical channels within a glass substrate. Two matching glass plates were subsequently cold bonded with the channels aligned; the flatness of the glass surfaces resulted in strong bonding through van der Waals forces. The device comprised gas fluidic interconnections, injection zone and 7.5 and 1.4 m long, 320 μm internal diameter capillaries. Optical microscopy confirmed the capillaries to have fully circular channel profiles. Direct column heating and cooling could be achieved using a combination of resistive heaters and Peltier devices. The low thermal conductivity of glass allowed for multiple uniform temperature zones to be achieved within a single glass chip. Temperature control over the range 10–200 °C was achieved with peak power demand of approximately 25 W. The 7.5 m capillary column was static coated with a 2 μm film of non-polar dimethylpolysiloxane stationary phase. A standard FID and a modified lightweight 100 mW photoionization detector (PID) were coupled to the column and performance tested with gas mixtures of monoaromatic and monoterpene species at the parts per million concentration level. The low power GC-PID device showed good performance for a small set of VOCs and sub ng detection sensitivity to monoaromatics.  相似文献   

8.
An electrochemical method based on a cytochrome c biosensor was developed, for the detection of selected arsenic and cyanide compounds. Boron doped diamond (BDD) electrode was used as a transducer, onto which cytochrome c was immobilised and used for direct determination of Prussian blue, potassium cyanide and arsenic trioxide. The sensitivity as calculated from cyclic voltammetry (CV) and square wave voltammetry (SWV), for each analyte in phosphate buffer (pH = 7) was found to be in the range of (1.1–4.5) × 10−8 A μM−1 and the detection limits ranged from 4.3 to 9.1 μM. The biosensor is therefore able to measure significantly lower than current Environmental Protection Agency (EPA) and World Health Organisation (WHO) guidelines, for these types of analytes. The protein binding was monitored as a decrease in biosensor peak currents by SWV and as an increase in biosensor charge transfer resistance by electrochemical impedance spectroscopy (EIS). EIS provided evidence that the electrocatalytic advantage of BDD electrode was not lost upon immobilisation of cytochrome c. The interfacial kinetics of the biosensor was modelled as equivalent electrical circuit based on electrochemical impedance spectroscopy data. UV–vis spectroscopy was used to confirm the binding of the protein in solution by monitoring the intensity of the soret bands and the Q bands. FTIR was used to characterise the protein in the immobilised state and to confirm that the protein was not denatured upon binding to the pre-treated bare BDD electrode. SNFTIR of cyt c immobilised at platinum electrode, was used to study the effect of oxidation state on the surface bond vibrations. The spherical morphology of the immobilised protein, which is typical of native cytochrome c, was observed using scanning electron microscopy (SEM) and confirmed the immobilisation of the cytochrome c without denaturisation.  相似文献   

9.
A choline oxidase (ChO) immobilized enzyme reactor (IMER) prepared by glutaraldehyde coupling of the enzyme on aminopropyl modified controlled pore glass beads is described. The ChO-IMER was coupled, in a flow injection configuration system, to an interference free hydrogen peroxide amperometric sensor based on a Pt surface modified by an overoxidized polypyrrole film. The resulting analytical device responds selectively to choline and displays a sensitivity of 46.9 ± 0.2 μC mM−1 and a limit of detection, calculated at a signal-to-noise ratio equal to 3, of 7 μM. Sensitivity remains constant for about 20 days and then starts to slowly deteriorate and after 2 months a 70% of the initial sensitivity was still retained. The application to choline determination in milk hydrolysates is demonstrated. Short- and long-term drift observed in the analytical response can be corrected by a bracketing technique.  相似文献   

10.
An electrochemical biosensor for the detection of microcystin has been developed based on the inhibition of the protein phosphatase 2A (PP2A) by this cyanobacterial toxin. The enzyme has been immobilised by entrapment using a poly(vinyl alcohol) azide-unit pendant water-soluble photopolymer (PVA-AWP). Electrode supports and immobilisation conditions have been optimised by colorimetric assays, the highest immobilisation yields being obtained with screen-printed graphite electrodes and the 1:2 PP2A:PVA ratio. Catechyl monophosphate (CMP), α-naphthyl phosphate (α-NP) and 4-methylumbelliferyl phosphate (4-MUP) have been used as phosphorylated substrates to monitor the protein phosphatase activity by electrochemical methods, the former providing the highest chronoamperometric currents at appropriate working potentials (+450 mV versus Ag/AgCl). Incubation with standard microcystin solutions has demonstrated the inhibition of the immobilised enzyme, proportional to the toxin concentration. The standard inhibition curve has provided a 50% inhibition coefficient (IC50) of 83 μg L−1, a limit of detection (LOD; 35% inhibition) of 37 μg L−1, and 100% inhibition at about 1000 μg L−1. Real samples of cyanobacterial blooms from the Tarn River (Midi-Pyrénées, France) have been analysed using the developed amperometric biosensor and the toxin contents have been compared to those obtained by a conventional colorimetric protein phosphatase inhibition (PPI) assay and high-performance liquid chromatography (HPLC). The results clearly justify the use of the developed amperometric biosensor as screening method for microcystin detection.  相似文献   

11.
Bead-based immunoassays using a micro-chip flow cytometer   总被引:2,自引:0,他引:2  
Holmes D  She JK  Roach PL  Morgan H 《Lab on a chip》2007,7(8):1048-1056
A microfabricated flow cytometer has been developed for the analysis of micron-sized polymer beads onto which fluorescently labelled proteins have been immobilised. Fluorescence measurements were made on the beads as they flowed through the chip. Binding of antibodies to surface-immobilised antigens was quantitatively assayed using the device. Particles were focused through a detection zone in the centre of the flow channel using negative dielectrophoresis. Impedance measurements of the particles (at 703 kHz) were used to determine particle size and to trigger capture of the fluorescence signal. Antibody binding was measured by fluorescence at single and dual excitation wavelengths (532 nm and 633 nm). Fluorescence compensation techniques were implemented to correct for spectral overspill between optical detection channels. The data from the microfabricated flow cytometer was shown to be comparable to that of a commercial flow cytometer (BD-FACSAria).  相似文献   

12.
Amini N  McKelvie I 《Talanta》2005,66(2):445-452
A sensitive and selective flow injection method for the determination of phosphatidylcholine (PC) in sediment pore waters and extracts is described. It involves the use of phospholipase C, alkaline phosphatase and choline oxidase co-immobilized on controlled pore glass in a packed column reactor. The final product of the enzymatic reaction of phosphatidylcholine is hydrogen peroxide, and this is detected by measuring the chemiluminescence emission resulting from cobalt(II) catalysed reaction with luminol. The flow injection method is rapid (30 injections/h), reproducible (1.4% R.S.D. at 3 μM PC, n = 10) with a detection limit of 0.14 μM (estimated from 3σn−1 of the measured blank). A linear calibration response was obtained over a concentration range of 0.5-9 μM (r = 0.999). The method has been applied to the determination of phosphatidylcholine in sediment extracts and sediment pore waters.  相似文献   

13.
A novel improved controlled pore glass (CPG) support based on the 2-(hydroxymethyl)-6-nitrobenzoyl (HMNB) protecting group was developed for the synthesis of 3-aminoalkylated oligonucleotides. The release of oligonucleotides with free 3-amino groups from the support is complete within 2 h at 55 °C in concentrated ammonia.  相似文献   

14.
The attachment of two aniline-based chromophores, Disperse Black 3 and Pararosaniline, to beaded controlled pore glass (CPG) and their testing as fibre optic based pH sensors is described. Synthetic methods for their attachment at specified loadings to CPG were developed. The Disperse Black 3 sensor displayed a rapid response time and a dynamic range between pH 1.0 and 2.5, while the Pararosaniline-bearing sensor gave an extremely slow response time but a large sensing range from pH 1 to 11.  相似文献   

15.
A new methyl viologen-mediated amperometric enzyme electrode sensitive to glucose has been developed using carbon film electrode substrates. Carbon film electrodes from resistors fabricated by pyrolytic deposition of carbon were modified by immobilization of glucose oxidase through cross-linking with glutaraldehyde in the presence of bovine serum albumin. The mediator, methyl viologen, was directly immobilised with the enzyme together with Nafion cation-exchange polymer. The electrochemistry of the glucose oxidase/methyl viologen modified electrode was investigated by cyclic voltammetry and by electrochemical impedance spectroscopy. The biosensor response to glucose was evaluated amperometrically; the detection limit was 20 μM, the linear range extended to 1.2 mM and the reproducibility of around 3%. When stored in phosphate buffer at 4 °C and used every day, the sensor showed good stability over more several weeks.  相似文献   

16.
A microfabricated electroosmotic pump with an integrated serpentine isolation channel was developed on a glass chip and applied to a capillary-based sequential injection analysis (SIA) system for an enzyme inhibition assay. The pump chip contains an anode reservoir, an ion-exchange membrane electric field decoupler (EFD) that also serves as a cathode reservoir, parallel pump channels and an isolation channel. A two-step etching process was adopted to etch the pump channels to a depth of 20 μm and the isolation channel to a depth of 90 μm. The pump flow rate was very stable: the relative standard deviation (RSD) of the pump rate was 1.9% for propulsion and 2.3% for aspiration. The pump chip was successfully applied to a capillary-based sequential injection analysis system with a confocal fluorescence detector. For repetitive analysis of a 13 μM fluorescein solution, an RSD of 0.6% was attained, which demonstrated the flow stability of the EOF pump. The system was then applied to an enzyme inhibition assay, the diethylenetriaminepentaacetic acid (DTPA) inhibition of the β-galactosidase-catalyzed hydrolysis of fluorescein di(β-d-galactopyranoside). Reproducible results (RSD<3.0%) were obtained.  相似文献   

17.
We report a simple and rapid procedure that leads to incorporation of mediator and introduction of amine functionality onto the surface of screen-printed carbon electrodes (SPCE). The electrodes were doped with cobalt phthalocyanine (CoPc) by enhanced adsorption in a process that uses minimal amounts of this redox mediator as compared with CoPc loaded inks. The CoPc-doped SPCE showed a substantially increased sensitivity to hydrogen peroxide and thiocholine as compared to unmodified electrodes. This greatly facilitated their use as transducers for the construction of amperometric biosensors based on enzymes producing oxidizable products such as hydrogen peroxide or thiols. Immobilisation of enzymes including glucose oxidase, acetylcholinesterase and choline oxidase was achieved through their multi-contact electrostatic interaction with polyethyleneimine (PEI) which was electrodeposited on the surface of CoPc-doped electrodes in one step from ethanolic solution. The efficiency of enzyme immobilisation was shown to depend on the molecular weight of the PEI used, reaching a maximum for 25 kDa PEI. The biosensors shown sensitivity to glucose at 130 nA mM−1 (LOD 0.15 mM) and to acetylcholine at 70 nA mM−1 (LOD 0.10 mM) under +0.6 V. Detection of glucose has been demonstrated at +0.4 V with the sensitivity of 60 nA mM−1 and LOD of 0.33 mM. Possibility of the inhibition analysis of pesticides has been shown for acetylcholinesterase-based sensors.  相似文献   

18.
The development of a highly sensitive method for the determination of nanomolar concentrations of hydrogen peroxide in the liquid phase is described. This paper demonstrates for the first time a flow injection analysis (FIA) system with immobilized enzyme reactor combined with a total internal reflective cell (a liquid waveguide capillary cell (LWCC)) and spectrophotometric detection, for the development of an improved procedure for the determination of hydrogen peroxide. Moreover, the newly synthesized 4-aminopyrazolone derivative, 4-amino-5-(p-aminophenyl)-1-methyl-2-phenyl-pyrazol-3-one (DAP), is used as a color coupler in its oxidative condensation with the sodium salt of N-ethyl-N-sulphopropylaniline sodium salt (ALPS) which acts as a hydrogen donor. Immobilization of peroxidase is achieved by coupling the periodate-treated enzyme to aminopropyl controlled-pore glass (CPG) beads. The determination of hydrogen peroxide is carried out in a 0.1 M phosphate buffer and the product is monitored at 590 nm with a charge-coupled device (CCD) detector equipped with fiber optics in a fully computerized system. The interference of different species, mainly ionic, was investigated.The method permits detection down to 4 nmol l−1 hydrogen peroxide (signal-to-noise ratio=3). A linear calibration graph was obtained over the range 20-700 nmol l−1. The relative standard deviation (R.S.D.) at 300 nmol l−1 H2O2 is 1.7% (n=7). The method was successfully applied for the determination of hydrogen peroxide in samples from a vat-cleaning process.  相似文献   

19.
Zhang Y  Deng S  Lei J  Xu Q  Ju H 《Talanta》2011,85(4):2154-2158
This work developed a novel method to greatly enhance the electrochemiluminescence (ECL) of CdS quantum dots (QDs). The ECL amplification was achieved by the assembly of QDs on poly (diallyldimethylammonium chloride)-functionalized carbon nanospheres (PFCNSs), and successfully employed for sensitive ECL biosensing of oxidase substrates. The carbon nanospheres were prepared by a “green” method, and the high loading of QDs on carbon nanospheres led to a 4-times increased ECL intensity with dissolved O2 as the coreactant. Using xanthine oxidase (XOD) as a model, an ECL biosensor was fabricated by immobilizing the enzyme on the mixing membrane of PFCNSs and QDs. The ECL biosensor showed a fast response to hypoxanthine with a linear concentration range from 2.5 × 10−8 to 1.4 × 10−5 M. The limit of detection was 5 nM at a signal-to-noise ratio of 3. The assay results of hypoxanthine in fish samples were in a good agreement with the reference values by amperometric technique. This facile approach to prepare the PFCNSs/QDs system for ECL biosensing could be of promising application in bioanalysis and electronic device.  相似文献   

20.
The catalytic performance of porous silicon (PS) micro enzyme reactors (muIMER) is strongly dependent on the PS matrix morphology for enzyme immobilisation. PS was achieved in the muIMER by anodisation in a HF-ethanol mixture. PS etching of structured silicon surfaces commonly results in an inhomogeneous pore formation. The deep channel microreactors described herein have previously suffered from these phenomena, yielding non-optimised muIMERs. In order to obtain a homogeneous PS layer on the deep microreactor channel walls, different reactor geometries (channel wall thicknesses of 50 and 75 mum) were anodised at 10 and 50 mA cm(-2) for anodisation times ranging between 0 and 50 min. The muIMERs were evaluated by immobilising two types of enzymes, glucose oxidase (GOx) and trypsin, and the resulting catalytic turnover was monitored by a colorimetric assay. It was found that reactors with a homogeneous PS matrix displayed improved performance. The trypsin muIMERs were used to digest a protein, beta-casein, in an on-line format and the digest was analysed by MALDI-TOF MS. The importance of tailoring the muIMER geometry and the PS-matrix is crucial for the protein digestion. Successful protein identification after only 12 s. digestion was demonstrated for the best reactor, 75 mum channel wall, 25 mum channel width, anodised at 50 mA cm(-2) for 10 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号