首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A time-based flow injection (FI) separation pre-concentration system coupled to an electrothermal atomic absorption spectrometer (graphite furnace) has been developed for the direct ultra-trace determination of selenite and selenate in drinking water. The pre-concentration of both forms of selenium is carried out onto a micro-column packed with an anionic resin (Dowex 1X8) that is placed in the robotic arm of the autosampling device. Selenite and selenate are sequentially eluted with HCl 0.1 M and HCl 4 M, respectively. The interference of large quantities of chloride during selenium atomisation is prevented by using iridium as a “permanent” chemical modifier. The features of the pre-concentration separation system for both species are: 53% efficiency of retention and an enhancement factor of 82 for a pre-concentration time of 180 s (sample flow rate=3 ml min−1) with HCl elution volumes of 100 μl. The detection limit (3 s) is 10 ng l−1 for the two species and the relative standard deviation (n=10) at the 200 ng l−1 level is 3.5% for selenite and 5.6% for selenate. The addition of selenite and selenate stock standard solutions to tap water samples yields a 97-103% recovery of both species.  相似文献   

2.
A flow injection on-line sorption system was developed for the separation and preconcentration of traces of Ag, Cd, Co, Ni, Pb, U and Y from natural water samples with subsequent detection by ICP TOF MS. Simultaneous preconcentration of the analytes was achieved by complexation with the chelating reagent 1-phenyl-3-methyl-4-benzoylpyrazol-5-one immobilized on the inner walls of a (200 cm × 0.5 mm) PTFE knotted reactor. The analytes were eluted and transported to an axial ICP TOF MS system with 1% (v/v) HNO3 containing 0.3 μg l−1 of Rh as an internal standard using ultrasonic nebulization. The detection limits (3σ) varied from 0.3 ng l−1 for Y to 15.2 ng l−1 for Ni and the precision (R.S.D.) was better than 4%. Using a loading time of 90 s and a sample flow rate of 4.5 ml min−1, enhancement factors of 3-14 were obtained for the different analytes in comparison with their direct determination by ICP TOF MS with ultrasonic nebulization without preconcentration. The accuracy of the method was demonstrated by analysis of water based certified reference materials.  相似文献   

3.
A modified automated on-line hyphenated system for simultaneous inorganic ionic mercury (Hg2+) and monomethylmercury (MeHg+) analysis by hydride generation (HG) or ethylation (Eth), cryofocussing, gas chromatography (GC) separation and atomic fluorescence spectrometry (AFS) detection has been improved. Both derivatization methods are investigated with respect to the chromatographic and analytical performances. They can be both affected by interferences when the AFS detection system is used. Water vapor removal using a soda lime moisture trap improves significantly the chromatographic performances, the reproducibility and the detection limits for Hg2+ and MeHg+ analyzed with both methods. For ethylation (Eth) derivatization, a scattering interference generated from low-quality ethylation reagent has also been eliminated. For HG, improved detection limits are 0.13 ng l−1 and 0.01 ng l−1 for Hg2+ and MeHg+, respectively (0.1 l water sample), and reproducibility are 5% for Hg2+ (20 ng l−1) and MeHg+ (5 ng l−1). Improved detection limits for Eth are 0.22 ng g−1 for Hg2+ and 0.02 ng g−1 for MeHg+ (1 g dry sediment sample) and the reproducibility are 5-6% for Hg2+ and MeHg+ (1-2 ng g−1).  相似文献   

4.
A simple and rapid method for the highly sensitive determination of polycyclic aromatic hydrocarbons (PAHs) in water was developed. Benzo[a]pyrene, benzo[k]fluoranthene, perylene, and pyrene in water were concentrated into sodium dodecyl sulfate (SDS)-alumina admicelles. The collection was performed by adding SDS and alumina particles into the sample solution at pH 2. After gentle mixing, the resulting suspension was passed through a membrane filter to collect the SDS admicelles containing highly concentrated PAHs. The filter was placed on a slide glass and then covered admicellar layer with a fused silica glass plate before setting in a fluorescence spectrometer. Benzo[a]pyrene, benzo[k]fluoranthene, perylene, and pyrene were selectively determined by the synchronous fluorescence scan (SFS) analysis with keeping wavelength intervals between excitation and emission to 98, 35, 29, and 45 nm, respectively. Because of the minimum spectral overlapping, 1-40 ng l−1 of benzo[a]pyrene, benzo[k]fluoranthene, and perylene as well as 10-150 ng l−1 of pyrene were selectively determined with eliminating the interferences of other 12 PAHs. The detection limits were 0.3 ng l−1 for benzo[a]pyrene, benzo[k]fluoranthene, and perylene, and 1 ng l−1 for pyrene. They were 2-3 orders of magnitude lower than the detection limits in normal aqueous micellar solutions. The application to water analysis was studied.  相似文献   

5.
A method for on-line preconcentration of palladium at ultra-trace level on alumina microcolumns and determination by inductively coupled plasma mass spectrometry (ICP-MS) has been developed. A sampling time of 10 min (30 ml) and an eluent (KCN) volume of 300 μl provides a limit of detection of 1 ng l−1. The precision was 4% at the 25 ng l−1 level. The proposed system allows the on-line removal of the primary interferents (Cu and Y) providing the credible accuracy of the results. The proposed method is suitable for palladium determination in urban water samples. Platinum concentration in the analysed urban water samples was also determined.  相似文献   

6.
A novel organic reagent 3-(8-quinolinylazo)-4-hydroxybenzoic acid (QAHBA) was synthesized for chemically modified nanometer-sized alumina, and it was characterized with infrared spectrum and 1H NMR spectra. By using modified nanometer-sized alumina as micro-column packing material, a new method of flow injection (FI) on-line preconcentration coupled to ICP-OES was developed for simultaneous determination of trace metals (Ag, Pd, Au, Ga, In and Nb) in geological and environmental samples. The effects of pH, sample flow rate, sample volume, elution and interfering ions on the recovery of the analytes have been investigated. Under the optimized operating conditions, the adsorption capacity of the modified nanometer-sized alumina for Ag, Pd, Au, Ga, In and Nb were found to be 5.1, 7.6, 17.7, 15.6, 8.1 and 12.3 mg g−1, respectively. With 4 min preconcentration time and 24 s elution time, the enrichment factor was 10 and the sample frequency was 10 h−1. The detection limits of this method for Ag, Pd, Au, Ga, In and Nb were 0.12, 0.44, 0.27, 0.19, 0.54 and 0.18 μg l−1, respectively, while the R.S.D.s were 1.6, 2.3, 4.5, 1.6, 1.9 and 1.7% (n = 7, c = 50 ng ml−1), respectively. The proposed method has been applied to the determination of these trace metals in geological-certified reference materials and natural water samples with satisfactory results.  相似文献   

7.
The analytical method for the determination of phosphorus in ultrapurified water was developed. Ultrapurified water was evaporated to concentrate phosphorus and the final sample volume for analysis was 10 ml. In 0.55 mol l−1 HCl, orthophosphate forms molybdophosphate, and then the molybdophosphate forms ion associate with Malachite Green (MG), which can be collected on a tiny membrane filter (diameter: 5 mm, and effective filtering diameter: 2 mm). After the ion associate on the membrane filter is dissolved together with the membrane filter in 1 ml of methyl cellosolve (MC), the absorbance of MC solution is measured at 627 nm by a flow injection-spectrophotometric detection technique. When 10 ml of the sample solution was used for the procedures and absorbance measurement, the calibration graph is linear up to about 500 ng l−1 of phosphorus and the detection limit was 8 ng l−1 (S/N=3). For the determination of phosphorus in an ultrapurified water, 10-40 ml of sample solutions were transferred into poly(tetrafluoroethylene) (PTFE) beaker and evaporated to 5 ml or to dryness. To them, 0.003 mol l−1 HCl was added to get 10 ml of final solution, which was used as sample. Phosphate is determined by comparing the slope of the varied sample volume after evaporation/concentration with a slope of the standard calibration graph (a slope comparison method: SCM). The SCM enables to evaluate the concentration of phosphate in ultrapurified waters more sensitively and accurately.  相似文献   

8.
A new method has been developed for the determination of gold based on separation and preconcentration with a microcolumn packed with nanometer TiO2 immobilized on silica gel (immobilized nanometer TiO2) prior to its determination by flame atomic absorption spectrometry. The optimum experimental parameters for preconcentration of gold, such as pH of the sample, sample flow rate and volume, eluent and interfering ions, have been investigated. Gold could be quantitatively retained by immobilized nanometer TiO2 in the pH range of 8-10, then eluted completely with 0.1 mol L−1 HNO3. The detection limit of this method for Au was 0.21 ng mL−1 with an enrichment factor of 50, and the relative standard deviation (R.S.D.) was 1.8% at the 100 ng mL−1 Au level. The method has been applied for the determination of trace amounts of Au in geological and water samples with satisfactory results.  相似文献   

9.
A new procedure was described with multiwalled carbon nanotubes as solid phase extraction packing material for the trace analysis of nicosulfuron, thifensulfuron and metsulfuron-methyl in water samples. The possible parameters influencing the enrichment were optimized and the optimal conditions were as followed: eluent, sample pH, flow rate and sample volume were acetonitrile containing 1% acetic acid, pH 3, 8 mL min−1 and 500 mL, respectively. Under the optimal chromatographic separation and SPE conditions, the linear range, detection limit (S/N = 3) and precision (R.S.D., n = 6) were 0.04-40 ng mL−1, 6.8 ng L−1 and 2.5% for nicosulfuron, 0.04-40 ng mL−1, 11.2 ng L−1 and 5.4% for thifensulfuron, 0.02-20 ng mL−1, 5.9 ng L−1, 2.1% for metsulfuron-methyl, respectively. The established method was well employed to determine nicosulfuron, thifensulfuron and metsulfuron-methyl in tap water, seawater, reservoir water and well water samples, and satisfactory results were obtained, the spiked recoveries in the range of 87.2-100.7%, 96.5-105.6% and 83.7-111.1% for them each, respectively.  相似文献   

10.
Zarei K  Atabati M  Ilkhani H 《Talanta》2006,69(4):816-821
A highly sensitive procedure is presented for the determination of ultra-trace concentration of molybdenum by catalytic adsorptive stripping voltammetry. The method is based on adsorptive accumulation of the molybdenum (Mo)-pyrocatechol violet (PCV) complex on to a hanging mercury drop electrode, followed by reduction of the adsorbed species by voltammetric scan using differential pulse modulation. The reduction current is enhanced catalytically by chlorate. The influence of variables was completely studied by factorial design analysis. Optimum analytical conditions for the determination of molybdenum were established. Molybdenum can be determined in the range 1.0 × 10−3-100.0 ng ml−1 with a limit of detection of 0.2 pg ml−1. The influence of potential interfering ions on the determination of molybdenum was studied. The procedure was applied to the determination of molybdenum in mineral water and some analytical grade substances with satisfactory results.  相似文献   

11.
We describe here a method for detecting and quantifying the highly carcinogenic polycyclic aromatic hydrocarbon (PAH) benzo[a]pyrene (BaP) in water, based on a flow-trough optical sensor. The technique is fast (response time of 40 s) and simple and at the same time meets the standards of sensitivity and selectivity required by the European Guidelines on Water for Human Consumption. The optosensor is based on the on-line immobilization of BaP on a non-ionic resin (Amberlite XAD-4) solid support in a continuous-flow system. BaP was analyzed in a 15 mM H2PO4/HPO42− buffer solution with 25% (v/v) 1,4-dioxane at pH 7. Fluorescence intensity was measured at λex/em=392/406 nm. The experimental conditions (reagent phase, pH, type and concentration of buffer solution and organic solvent) and flow-injection values (flow rate and injection volume) were carefully controlled. Under these conditions the optosensor was sensitive to a linear concentration range of between 3.0 and 250.0 ng l−1 with a detection limit of 3.0 ng l−1 and a standard deviation of 1.5% at 150 ng l−1. The optosensor was applied to the quantification of BaP in drinking and waste water samples (95-105% recovery) in presence of the other 15 EPA PAHs at 1000 ng l−1 concentration level. The influence of other fluorescent polycyclic aromatic hydrocarbons and potential interference from ions usually present in water was also evaluated.  相似文献   

12.
A fiber-in-tube microextraction protocol was developed and coupled with gas chromatography-electron capture detector (GC-ECD) for determination of trace hexachlorocyclohexanes (HCHs) in water samples. The developed technique was performed by immersing a PTFE fiber-packed and organic solvent-filled PTFE tube in the stirred aqueous solution. Extraction took place between the solvent permeated fibers and sample solution. The extract was then analyzed by GC-ECD. The effects of fiber quantity, extraction time, agitation, addition of salt and pH of sample solution were investigated in detail. Extraction of the analytes in 8 ml aqueous solution for 20 min yielded enrichment factors of 221-538. The limits of detection (S/N = 3) and the limits of quantitation (S/N = 8) were 2-12 ng l−1 and 6-32 ng l−1, respectively. The precision (R.S.D.s, n = 5) was 0.1% for retention time and 1.8-4.8% for peak height. The developed methodology was applied to the determination of trace HCHs in local river water samples.  相似文献   

13.
A highly sensitive mechanized method has been developed for the determination of mercury in milk by atomic fluorescence spectrometry (AFS). Samples were sonicated for 10 min in an ultrasound water bath in the presence of 8% (v/v) aqua regia, 2% (v/v) antifoam A and 1% (m/v) hydroxilamine hydrochloride, and after that, they were treated with 8 mmol l−1 KBr and 1.6 mmol l−1 KBrO3 in an hydrochloric medium. Atomic fluorescence measurements were made by multicommutation, which provides a fast alternative in quality control analysis, due to the easy treatment of a large number of samples (approximately 70 h−1), and is an environmentally friendly procedure, which involves a waste generation of only 94.5 ml h−1 as compared with the 605 ml h−1 obtained by using continuous AFS measurements. The limit of detection found was 0.011 ng g−1 Hg in the original sample. The method provided a relative standard deviation of 3.4% for five independent analysis of a sample containing 0.30 ng g−1 Hg. To validate the accuracy of the method, a certified reference material NIST-1459 (non-fat milk powder) containing 0.3±0.2 ng g−1 Hg was analysed and a value of 0.27±0.06 ng g−1 Hg was found. A comparison made between data found by the developed procedure and those obtained by microwave-assisted digestion and continuous AFS measurements evidenced a good comparability between these two strategies. Results obtained for commercially available milk samples varied between 0.09 and 0.61 ng g−1 Hg depending on the type of sample and its origin. The confluence of the analytical waste with a 6 mol l−1 NaOH allowed us to reduce the waste generation in a working session from 1 l to 5 g solid residue with a matrix of Fe(OH)3 which contributes to the deactivation of traces of heavy metals presents in the samples that does not form volatile hydrides.  相似文献   

14.
Abdorreza Mohammadi 《Talanta》2009,78(3):1107-1114
A simple and rapid headspace solid-phase microextraction (HS-SPME) based method is presented for the simultaneous determination of atrazine and ametryn in soil and water samples by ion mobility spectrometry (IMS). A dodecylsulfate-doped polypyrrole (PPy-DS), synthesized by electrochemical method, was applied as a laboratory-made fiber for SPME. The HS-SPME system was designed with a cooling device on the upper part of the sample vial and a circulating water bath for adjusting the sample temperature. The extraction properties of the fiber to spiked soil and water samples with atrazine and ametryn were examined, using a HS-SPME device and thermal desorption in injection port of IMS. Parameters affecting the extraction efficiency such as the volume of water added to the soil, pH effect, extraction time, extraction temperature, salt effect, desorption time, and desorption temperature were investigated. The HS-SPME-IMS method with PPy-DS fiber, provided good repeatability (RSDs < 10 %), simplicity, good sensitivity and short analysis times for spiked soil (200 ng g−1) and water samples (100 and 200 ng mL−1). The calibration graphs were linear in the range of 200-4000 ng g−1 and 50-2800 ng mL−1 for soil and water respectively (R2 > 0.99). Detection limits for atrazine and ametryn were 37 ng g−1 (soil) and 23 ng g−1 (soil) and 15 ng mL−1 (water) and 10 ng mL−1 (water), respectively. To evaluate the accuracy of the proposed method, atrazine and ametryn in the three kinds of soils and two well water samples were determined. Finally, comparing the HS-SPME results for extraction and determination of selected triazines using PPy-DS fiber with the other methods in literature shows that the proposed method has comparable detection limits and RSDs and good linear ranges.  相似文献   

15.
A new micelle-mediated extraction method for preconcentration of ultra-trace quantities of beryllium and aluminum as a prior step to their simultaneous spectrophotometric determination has been developed. Chrome Azurol S (CAS), cetyltrimethylammonium bromide (CTAB) and Triton X-114 were used as chelating agent, cationic surfactant for extraction and co-extraction agent, respectively. Mean centering (MC) of ratio spectra has been used for simultaneous analysis of beryllium and aluminum. The optimal extraction and reaction conditions were studied, and the analytical characteristics of the method (e.g., limit of detection, linear range, preconcentration, and improvement factors) were obtained. Linearity was obeyed in the range of 5-40 ng mL−1 of beryllium and 3-100 ng mL−1 of aluminum. The detection limit of the method is 0.98 and 0.52 ng mL−1 for beryllium and aluminum, respectively. The interference effect of some anions and cations was also tested. The method was applied to the simultaneous determination of beryllium in water samples.  相似文献   

16.
The cloud point extraction (CPE) preconcentration of ultra-trace amount of mercury species prior to reverse-phase high performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS) detection was studied. Mercury species including methyl-, ethyl-, phenyl- and inorganic mercury were transformed into hydrophobic chelates by reaction with sodium diethyldithiocarbamate, and the hydrophobic chelates were extracted into a surfactant-rich phase of Triton X-114 upon heating in a water bath at 40 °C. Ethylmercury was found partially decomposed during the CPE process, and was not included in the developed method. Various experimental conditions affecting the CPE preconcentration, HPLC separation, and ICP-MS determination were optimized. Under the optimized conditions, detection limits of 13, 8 and 6 ng l−1 (as Hg) were achieved for MeHg+, PhHg+ and Hg2+, respectively. Seven determinations of a standard solution containing the three mercury species each at 0.5 ng ml−1 level produced relative standard deviations of 5.3, 2.3 and 4.4% for MeHg+, PhHg+ and Hg2+, respectively. The developed method was successfully applied for the determination of the three mercury species in environmental water samples and biological samples of human hair and ocean fish.  相似文献   

17.
A simple and highly selective flow injection (FI) on-line preconcentration and separation flame atomic absorption spectrometric (FAAS) method was developed for the determinations of trace amounts of silver, gold and palladium. The selective preconcentration of the noble metals was achieved in a wide range of sample acidity (0.1-6 M HNO3 or HCl) on a microcolumn packed with amidinothioureido-silica gel (ATuSG). The analytes retained on the column were effectively eluted with 5.0% thiourea solution. The analytical procedure was optimized for sample acidity, elution, interferences, flow rate of sampling and eluting, and concentration of sample. Common co-existing cations and anions did not interfere with the preconcentration and determination of the three metals. At a sample loading flow rate of 4.5 ml min−1 with 60 s preconcentration, detection limits (3σ) of 1.1 ng ml−1 Ag, 13 ng ml−1 Au and 17 ng ml−1 Pd were obtained. The precisions (R.S.D., n=11) were 1.2% for Ag, 1.2% for Au and 1.7% for Pd, respectively. The detection limits can be further improved by increasing sample volume. The analytical results obtained by the proposed method for a number of standard reference materials were in good agreement with the certified values.  相似文献   

18.
A rapid and sensitive method for the determination of carbendazim (methyl benzimidazole-2-ylcarbamate, MBC) and thiabendazole (TBZ) in water and soil samples was developed by using dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography with fluorescence detection. The water samples were directly used for the DLLME extraction. For soil samples, the target analytes were first extracted by 0.1 mol L−1 HCl. Then, the pH of the extract was adjusted to 7.0 with 2 mol L−1 NaOH before the DLLME extraction. In the DLLME extraction method, chloroform (CHCl3) was used as extraction solvent and tetrahydrofuran (THF) as dispersive solvent. Under the optimum conditions, the enrichment factors for MBC and TBZ were ranged between 149 and 210, and the extraction recoveries were between 50.8 and 70.9%, respectively. The linearity of the method was obtained in the range of 5-800 ng mL−1 for water sample analysis, and 10-1000 ng g−1 for soil samples, respectively. The correlation coefficients (r) ranged from 0.9987 to 0.9997. The limits of detection were 0.5-1.0 ng mL−1 for water samples, and 1.0-1.6 ng g−1 for soil samples. The relative standard deviations (RSDs) varied from 3.5 to 6.8% (n = 5). The recoveries of the method for MBC and TBZ from water samples at spiking levels of 5 and 20 ng mL−1 were 84.0-94.0% and 86.0-92.5%, respectively. The recoveries for soil samples at spiking levels of 10 and 100 ng g−1 varied between 82.0 and 93.4%.  相似文献   

19.
Chen L  Chen W  Ma C  Du D  Chen X 《Talanta》2011,84(1):104-108
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes/polypyrrole (MWCNTs/Ppy) was prepared with an electrochemical method and used for the extraction of pyrethroids in natural water samples. The results showed that the MWCNTs/Ppy coated fiber had high organic stability, and remarkable acid and alkali resistance. In addition, the MWCNTs/Ppy coated fiber was more effective and superior to commercial PDMS and PDMS/DVD fibers in extracting pyrethroids in natural water samples. Under optimized conditions, the calibration curves were found to be linear from 0.001 to 10 μg mL−1 for five of the six pyrethroids studied, the exception being fenvalerate (which was from 0.005 to 10 μg mL−1), and detection limits were within the range 0.12-0.43 ng mL−1. The recoveries of the pyrethroids spiked in water samples at 10 ng mL−1 ranged from 83 to 112%.  相似文献   

20.
In geological samples, Se concentration ranges from 1 × 10−9 g g−1 up to 1 × 10−3 g g−1. The analytical difficulty at low concentration (<1 μg g−1), is one of the main reasons why the geological cycle of Se is poorly known. The analytical method that consisted of preconcentration of Se with thiol cotton fiber (TCF) followed by graphite furnace atomic absorption spectrometry (GFAAS) has been modified by finishing with instrumental neutron activation analysis (INAA). The modified technique involves sample dissolution (HF-HNO3-H2O2) and evaporation to dryness at low temperature (55-60 °C) to avoid selenium volatilization. SeVI is converted to SeIV by adding 6 M HCl to the dry residuum and the solution is then heated in a covered boiling bath (95-100 °C). The solution is diluted to obtain 0.6 M HCl and then collected on TCF. The TCF is placed in a polyethylene vial for irradiation in the SLOWPOKE II reactor (Montréal) for 30 s at a neutron flux of 1015 m−2 s−1. The 162 keV peak of 77mSe (half-life 17.36 s) is read for 20 s after a decay of 7 s. The amount of sample to be dissolved is controlled by two competing effects. To obtain low detection limits, a larger amount of sample should be dissolved. On the other hand, the TCF could become saturated with chalcophile elements when large sample is used. Sulfur is a good indicator of the amount of Se and chalcophile elements present. In S poor sample (<100 μg g−1) 3.0 g of sample was used and the LD was ∼2 ng g−1. In S high samples (>1.5% S) 0.05 g of sample was used and the LD was ∼120 ng g−1. The present work also includes suggested Se concentration for eight international geological reference materials (IGRM) that compare favorably with literature values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号