首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Laser-excited ionic fluorescence has been used to study the effects of sample matrix, operating conditions, and load coil shielding on analyte ion transport efficiency through the sampling orifice of an inductively coupled plasma mass spectrometer. Significant changes in ion transport efficiency result from changes in sample composition, RF forward power, nebulizer flow and torch shield configuration. The changes in ion transport efficiency correlate well with changes in the potential recorded on a single floating probe placed 1 mm upstream from the sampling orifice.  相似文献   

2.
The use of cold vapor generation as a means of sample introduction for atomic spectrometry offers several significant advantages over conventional technique using pneumatic nebulizer for the transport of sample in liquid forms. These advantages include, among others,high transport efficiency; the free of analyte form the sample matrices and the improvement of detection limits.  相似文献   

3.
Reported are results for the quantitative determination of absolute transport efficiency in electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) for the Perkin-Elmer HGA-600MS electrothermal vaporizer. The absolute transport efficiencies for Mo, In, Tl and Bi were determined using experimental conditions typical of those applied to real analysis by ETV-ICP-MS. Experiments using an on-line filter trapping apparatus indicated that particles produced by the ETV device were smaller than 0.1 μm in diameter. The nature and condition of the ETV graphite surface, the length of the transfer tube, and the effect that diluted seawater and palladium modifiers have on analyte transport efficiency were investigated. Transport efficiency was comparable for all elements studied and was enhanced with previously used, rather than new, graphite tubes and when seawater and palladium carriers were present. When analyte was vaporized without carrier from a new graphite tube, the transport efficiency to the plasma was approximately 10%. Approximately 70% of the total amount of analyte vaporized was deposited within the ETV switching valve, 19% onto the transfer tubing and 1% onto the components comprising the torch assembly. These conditions represent the `worst case scenario', with analyte transport to the plasma increasing to approximately 20% or more with the addition of carrier.  相似文献   

4.
Rapid aqueous sample extraction (RASE) devices were constructed and characterized using m-xylene as a test analyte. Extraction of m-xylene from aqueous samples was studied under many different conditions, independently varying extractor volume, extraction gas flow rate, temperature, pressure, sample volume, and sample concentration. Gas samples were analyzed as controls to determine the non-extraction (transport) component of the analyte pulse width. The extraction of analyte from water to the gas phase took proportionately longer (compared to transport) for RASE apparatus that had a volume greater than 10 ml. An order of magnitude change in RASE volume resulted in larger than an order of magnitude change in extraction time and total analyte pulse width. The flow rate of the extraction gas had a much larger effect on a RASE apparatus with a volume greater than 10 ml. For these large extractors, both extraction time and total analyte pulse width decreased by a factor of 4 for a flow increase from 40 to 120 ml min(-1). There was little change at higher flow rates, or for extractors with smaller volumes. Temperatures below 40 degrees C resulted in large increases in the pulse duration due to broadening during transport. The temperature effect on extraction time was only a factor of 2 over a range from 25 to 85 degrees C. Pressure also had only a relatively small effect, increasing extraction time and total pulse width by a factor of 2 over a range from 12 to 34 PSI. There was no observed change in either extraction time or total pulse width when the sample volume injected varied from 10 to 1000 mul, or over a concentration range from 170 to 17 000 mug l(-1). RASE apparatus were capable of complete extraction of analyte from water in less than 5 s under optimized conditions.  相似文献   

5.
The efficiency data from individual reports on chemical vapour generation (CVG) of transition and noble metals are overviewed with respect to the ways that they were obtained. The values derived from direct measurement of analyte in the gaseous phase or obtained from comparison with other sample introduction techniques reflect well the true chemical vapour generation efficiency. The efficiencies reported this way do not exceed 30%. On the other hand, the percentage efficiency values derived from determination of analyte remaining in the waste liquid, usually in the high tens, can substantially overestimate the efficiency by neglecting the analyte retained within the system.  相似文献   

6.
7.
Bleiner D  Lienemann P  Vonmont H 《Talanta》2005,65(5):1286-1294
Laser ablation in combination with plasma spectrochemistry is an ideal technique for depth profiling analysis, based on signal profiles. However, signal profiles were found to be critically influenced by the characteristics of the ablated particles, especially their composition and size distribution, and consequently transport mechanism and plasma-assisted vaporization efficiency. Even for a refractory material like ceramic, relics of melting following laser irradiation were found, so that particles were non-stoichiometric as compared to the parent material. Estimates of transport efficiency showed that this is highly variable as a function of particle size. Large particles are likely to be lost in the sample chamber. Fine particles are prone to wall reaction, especially in Ar ambient. Variability in particle delivery to the ICP-MS was suspected to be the cause for an element-dependent analyte signal response. Fluctuation in particle vaporization degree as a consequence of plasma temperature instability was also responsible for element-dependent signal profile deviation. However, for a 10-fold higher mass load into the plasma, no direct fractionation effects were observed. Differential transport of chemically-differentiated analyte-carriers is suggested to be primary cause for element-dependent signal structure.  相似文献   

8.
A modified graphite furnace for solid-sampling atomic absorption spectrometry as an electrothermal vaporizer (ETV) was coupled to a Perkin-Elmer/Sciex ELAN 6000 ICP mass spectrometer. The integrals obtained from electrothermal vaporization of aliquots containing As, Cd, Cu, Co, Fe, Mn, Pb, Se, and Zn were compared with those obtained from pneumatic nebulization of the same aqueous standard solution. The pneumatic nebulizer was calibrated by weighing the mass of aqueous aerosol trapped on a filter. With "wet plasma" conditions maintained also for measurements with the ETV and reference signals for analyte signals obtained with the calibrated pneumatic nebulization, the transport efficiency of the ETV system, e.g. the ratio of the analyte amount introduced into the plasma to that amount dosed into the vaporizer, was determined. The transport efficiency of two different tube and interface designs has been evaluated. Investigations with and without the use of trifluoromethane as reactive gas, with different furnace heating rates, and with varying gas flows were performed. In general, the tube equipped with a nozzle led to generally higher transport efficiency than the standard tube. Without trifluoromethane transport efficiencies ranged from 10% to 35% with the standard tube and from 15% to 50% with the nozzle-type tube. With addition of 2 mL min(-1) trifluoromethane to the argon flow of 400 mL min(-1) through the tube, transport efficiencies from 20% to 70% and from 70% to 100% were achieved with the standard and nozzle-type tubes, respectively.  相似文献   

9.
A modified graphite furnace for solid-sampling atomic absorption spectrometry as an electrothermal vaporizer (ETV) was coupled to a Perkin–Elmer/Sciex ELAN 6000 ICP mass spectrometer. The integrals obtained from electrothermal vaporization of aliquots containing As, Cd, Cu, Co, Fe, Mn, Pb, Se, and Zn were compared with those obtained from pneumatic nebulization of the same aqueous standard solution. The pneumatic nebulizer was calibrated by weighing the mass of aqueous aerosol trapped on a filter. With “wet plasma” conditions maintained also for measurements with the ETV and reference signals for analyte signals obtained with the calibrated pneumatic nebulization, the transport efficiency of the ETV system, e.g. the ratio of the analyte amount introduced into the plasma to that amount dosed into the vaporizer, was determined. The transport efficiency of two different tube and interface designs has been evaluated. Investigations with and without the use of trifluoromethane as reactive gas, with different furnace heating rates, and with varying gas flows were performed. In general, the tube equipped with a nozzle led to generally higher transport efficiency than the standard tube. Without trifluoromethane transport efficiencies ranged from 10% to 35% with the standard tube and from 15% to 50% with the nozzle-type tube. With addition of 2 mL min–1 trifluoromethane to the argon flow of 400 mL min–1 through the tube, transport efficiencies from 20% to 70% and from 70% to100% were achieved with the standard and nozzle-type tubes, respectively.  相似文献   

10.
Pekol TM  Poopisut N  Cox JA 《Talanta》1994,41(5):663-668
Uphill transport of L-Dopa and phenylalanine (Phe) across cation-exchange membranes into micelle-containing receiver solutions is reported. With L-Dopa as the analyte in a sample solution at a pH where it is it a zwitterion, preconcentration by a factor of 3.2 +/- 0.2 (n = 5) is observed when 0.10M sodium dodecyl sulfate (SDS) is the receiver. When the SDS concentration is varied, preconcentration of L-Dopa is not observed until the critical micelle concentration is reached. Similar results were obtained with Phe as the analyte under conditions where it is protonated in both the sample and receiver. The transport is demonstrated to obey the assumptions required to quantify the results by the fixed-time kinetic method. That is, the amount of Phe transferred from a 200-ml sample across a 10-cm(2) membrane into a 5-ml receiver was directly proportional both to the dialysis time for up to 90-min and to the initial concentration of Phe in the sample when a 60-min dialysis time was used. The latter yielded a constant enrichment factor, 4.8 +/- 0.2 (n = 6), when the sample concentration of Phe was in the range 0.61 mM-6.0 muM. Means to increase the enrichments to practical values are discussed.  相似文献   

11.
Ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry (USS-ETV-ICP-MS) is a very powerful technique for the direct analysis of solid materials prepared as slurries. The use of isotope dilution USS-ETV-ICP-MS (USS-ETV-ID-ICP-MS) for micro-homogeneity characterization studies of powdered reference materials based on elemental analyses, was investigated. Slurry analysis conditions were optimized taking into consideration density, particle size, analyte extraction, slurry mixing, analyte transport and sampling depth. Slurries were prepared using 1–20 mg of material and adding 1.0 ml of 5% nitric acid diluent containing 0.005% Triton X-100®. Three reference materials were analyzed (RM 8431a Mixed Diet, SRM 1548a Typical Diet and SRM 2709 San Joaquin Soil). Cu and Ni were determined in each material and Fe was also determined in RM 8431a Mixed Diet. ETV conditions were optimized and the benefit of using Pd as a carrier to enhance transport, combined with oxygen ashing was demonstrated. The accuracy of the method was verified by comparing analytical results with certified values. The precision of the method was demonstrated by comparing R.S.D.'s for slurry samples and aqueous standards and elemental ‘homogeneity’ was quantified based on the slurry sampling variability. The representative sample mass analyzed was calculated taking into consideration extraction of analyte into the liquid phase of the slurry. Representative sample masses of approximately 4 mg of RM 8431a provided slurry sampling variabilities of 10% or less for Cu, Fe and Ni. Representative sample masses of approximately 10 mg of SRM 1548a provided slurry sampling variabilities of approximately 10% for Cu and Ni. Representative sample masses of approximately 0.3 mg of SRM 2709 resulted in total analytical variabilities of less than 7%, highlighting the fact that the San Joaquin Soil is clearly the most homogeneous of the materials characterized.  相似文献   

12.
A glass capillary ultramicroelectrode (tip diameter approximately 1.2 microm) having an electrokinetic sampling ability is described. It is composed of a pulled glass capillary filled with an inner solution and three internal electrodes (Pt working and counter electrodes and an Ag/AgCl reference electrode). The voltammetric response of the capillary electrode is based on electrokinetic transport of analyte ions from the sample solution into the inner solution across the conical tip. It was found that the electrophoretic migration of analytes at the conical tip is faster than electroosmotic flow, enabling electrokinetic transport of analyte ions into the inner solution of the electrode. By using [Fe(CN)6]4- and (ferrocenylmethyl)trimethylammonium (FcTMA+) ions as model analytes, differential pulse voltammetric responses of the capillary electrode were investigated in terms of tip diameter of the capillary, sampling voltage, sampling time, detection limit and selectivity. The magnitude of the response depends on the size and charge of analyte ions. With a capillary electrode having a approximately 1.2-microm tip diameter, which minimizes non-selective diffusional entry of analytes, the response after 1 h sampling at +1.7 V is linearly related to [Fe(CN)6]4- concentration in the range of 0.50-5.0 mM with the detection limit of 30 microM. Application of a potential of the same sign as that of the analyte ion forces the analyte to move out from the electrode to the solution, enabling reuse of the same capillary electrode. The charge-selective detection of analytes with the capillary electrode is demonstrated for [Fe(CN)6]4- in the presence of FcTMA+.  相似文献   

13.
The investigation of a combined thin-layer chromatography/matrix-assisted laser desorption/ionization mass spectrometry (TLC/MALDI-MS) method for the analysis of siderophores from microbial samples is described. The investigated siderophores were enterobactin, ferrioxamine B, ferrichrome, ferrirhodin, rhodotorulic acid and coprogen. Solid-phase extraction was employed to recover the siderophores from the microbial samples. After visualization of the spots via spraying with ferric chloride or chrome azurol sulfonate assay solution, the MALDI matrix was applied to the gel surface. Several TLC/MALDI experimental parameters were optimized, such as type and concentration of MALDI matrix, as well as the type and composition of solvent to facilitate analyte transport from the inside of the TLC gel to the surface. The impact of these parameters on sensitivity, precision and ion formation of the various siderophores was studied. The detection limits for the investigated siderophores were in the range 1-4 pmol. These values were about 4-24 times higher than the detection limits obtained directly from stainless steel MALDI targets. The differences were most likely due to incomplete transport of the 'trapped' analyte molecules from the deeper layers of the TLC gel to the surface and into the matrix layer. In addition, chromatographic band broadening spread the analyte further in TLC as compared with the steel plates, resulting in less analyte per surface area. The identification of the siderophores was aided by concurrently applying a Ga(III) nitrate solution to the TLC plate during the visualization step. The resulting formation of Ga(III) complexes lead to distinctive (69)Ga/(71)Ga isotope patterns in the mass spectra. The versatility of the TLC/MALDI-MS assay was demonstrated by using it to analyze siderophores in a Pseudomonas aeruginosa sample. An iron-binding compound was identified in the sample, namely pyochelin (2-(2-o-hydroxyphenyl-2-thiazolin-4-yl)-3-methylthiazolidine-4-carboxylic acid).  相似文献   

14.
The use of a poly(methylmethacrylate) capillary electrophoresis chip, provided with a high sample load capacity separation system (a 8500 nL separation channel coupled to a 500 nL sample injection channel) and a pair of on-chip conductivity detectors, for zone electrophoresis (ZE) determination of oxalate in urine was studied. Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the chip were suppressed and electrophoresis was a dominant transport process in the separations performed on the chip. A low pH of the carrier electrolyte (4.0) provided an adequate selectivity in the separation of oxalate from anionic urine constituents and, at the same time, also a sufficient sensitivity in its conductivity detection. Under our working conditions, this anion could be detected at a 8 x 10(-8) mol/L concentration also in samples containing chloride (a major anionic constituent of urine) at 3.5 x 10(-3) mol/L concentrations. Such a favorable analyte/matrix concentration ratio (in part, attributable to a transient isotachophoresis stacking in the initial phase of the separation) made possible accurate and reproducible (typically, 2-5% relative standard deviation (RSD) values of the peak areas of the analyte in dependence on its concentration in the sample) determination of oxalate in 500 nL volumes of 20-100-fold diluted urine samples. Short analysis times (about 280 s), no sample pretreatment (not considering urine dilution) and reproducible migration times of this analyte (0.5-1.0% RSD values) were characteristic for ZE on the chip. This work indicates general potentialities of the present chip design in rapid ZE analysis of samples containing the analyte(s) at high ionic matrix/analyte concentration ratios.  相似文献   

15.
16.
Fundamental understanding of the impact of reservoir potentials on the analyte behavior on the microfluidic chips is an important issue in microchip electrophoresis (MCE) for suitable injection and separation of analytes, since the applied potentials may significantly affect the shape of sample plug, sample leakage from the injection channel to the separation channel, injected sample amount, and separation efficiency. This study addressed this issue for the case of a conventional cross-geometry microchip with four reservoirs using computer simulations, the results of which were verified by the analysis of DNA fragments. For the microchip with a definite structure and migration distance, the injected sample amount was shown to be the vital parameter for improving the limit of detection and resolution. During injection, the shape of the sample plug could be adjusted by varying the reservoir potentials. It was demonstrated that a "magnified injection" (applying high voltage on the three reservoirs to the sample reservoir) is useful to enhance the detection sensitivity depending on the analyte composition, although such injection was previously avoided because of introducing too large amounts of the analyte in comparison with two established modes, floating and pinched injection. Optimal magnified injection was proved to improve the sensitivity for about 4 times over that of pinched injection for the analysis of DNA step ladders using microchip gel electrophoresis (MCGE). Sample leakage of DNA fragments could be suppressed by applying a high positive voltage on injection channel during separation, but the voltage degraded the injected amount and resolution.  相似文献   

17.
Signal equations basing on dispersion functions describing the measured temporal intensity distribution for laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS) used in scanning and drilling mode are developed. Variable ablation rates due to either varying focussing conditions typical for drilling mode and due to the changes of physical and chemical properties in inhomogeneous samples as typically investigated in scanning mode are considered for. The model accounts for intermixing of the sample aerosol within the sampling chamber, the influence of transport in a cylindrical transport channel and the fact that normally not the entire vapour generated and transported to the ICP can be observed. The absolute signal response is influenced by the actually ablated, transported and observed analyte mass. The dispersion functions describing the relative signal response depend on sample chamber volume, the volume of the transport channel, the laser shot frequency, the carrier gas flow rate and the part of observable cross-section at the MS interface compared to the entire cross-section filled by the vapour. All these parameters depend on the experimental set-up and the selected operating conditions only. Using the signal equation the influence of all mentioned parameters on signal course is shown both theoretically and experimentally. The signal equation can be used for calculation of optimal experimental conditions.

On this basis, an algorithm is proposed providing the relative temporal distribution of any analyte with significantly higher temporal resolution than the measured temporal intensity distribution itself. Furthermore, usage of dispersion functions for investigation of a given transport system, for explanation of typical signal deviations, for the proof of homogeneous regions in a heterogeneous sample, for examination of changes in ablation rate and for investigation of fractionation effects is shown.  相似文献   


18.
An ESI emitter made of poly(dimethylsiloxane) interfaces on-chip sample preparation with MS detection. The unique multilayer design allows both the analyte and the spray solutions to reside on the device simultaneously in discrete microfluidic environments that are spatially separated by a polycarbonate track-etched, nanocapillary array membrane (NCAM). In direct spray mode, voltage is applied to the microchannel containing a spray solution delivered via a syringe pump. For injection, the spray potential is lowered and a voltage is applied that forward biases the membrane and permits the analyte to enter the spray channel. Once the injection is complete, the bias potential is switched off, and the spray voltage is increased to generate the ESI of the injected analyte plug. Consecutive injections of a 10 microM bovine insulin solution are reproducible and produce sample plugs with limited band broadening and high quality mass spectra. Peptide signals are observed following transport through the NCAM, even when the peptide is dissolved in solutions containing up to 20% seawater. The multilayer emitter shows great potential for performing multidimensional chemical manipulations on-chip, followed by direct ESI with negligible dead volume for online MS analysis.  相似文献   

19.
Sinton D  Ren L  Xuan X  Li D 《Lab on a chip》2003,3(3):173-179
As an increasing number of processes are being integrated into Lab-on-a-chip devices, there is an increasing need for flexible and accurate sample manipulation techniques for effective transport and separation. Conductivity differences between running buffer and analyte samples can arise as a product of on-chip processing, or by design. The two situations studied here are sample pumping (where bulk transport is increased and separation of charged analytes is delayed using a relatively high conductivity sample), and sample stacking (where bulk transport is decreased and separation of charged analytes is expedited using a relatively low conductivity sample). A recently developed dynamic loading method for on-chip sample injection in a straight-cross channel configuration is applied here to both pumping and stacking cases. A key characteristic of the dynamic loading method is the ability to inject samples of high concentration density and uniformity of any length. By employing the conductivity differences alone, the effectiveness of either sample transport or sample separation are shown to improve over the uniform conductivity case. Then it is demonstrated that increasing the sample length, through dynamic loading, greatly increases the effectiveness of sample pumping, evidenced in an eight-fold increase in peak height as well as a decrease in total sample length at a downstream detector. Dynamic loading in the sample stacking case was shown to also increase peak intensity height (three-fold) in rapid separations. These results demonstrate that the dynamic loading technique, used in conjunction with strategic conductivity differences, significantly extends the capabilities of microfluidic chips.  相似文献   

20.
Cation-exchange micro solid-phase extraction (SPE) tips and aqueous normal-phase (ANP) chromatography coupled with tandem mass spectrometry were explored for the rapid, selective and sensitive quantitation of desloratadine and pseudoephedrine in human plasma. A novel micro-SPE device was evaluated for analyte capacity, extraction efficiency and its ability to maximize recovery of an analyte of interest from bioanalytical matrices by successive replicates of linked extraction steps. Ion suppression using two different methods with micro-SPE tips was negligible when compared to protein precipitation. The use of ANP chromatography eliminated the need for sample reconstitution following extraction and was found to be highly selective. A reliable chromatography system was developed with a short duty cycle of 2 min/sample. The proposed bioanalytical method required 50 microL of plasma for the determination of desloratadine and pseudoephedrine at limits of quantitation of 0.1 and 1.25 ng/mL, respectively. The analytical method was validated in accordance with the FDA guidance on bioanalytical method validation; selectivity, linearity, reproducibility and accuracy were all acceptable.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号