首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 506 毫秒
1.
A new method is presented for elemental and molecular analysis of halogen-containing samples by glow discharge time-of-flight mass spectrometry, consisting of detection of negative ions from a pulsed RF glow discharge in argon. Analyte signals are mainly extracted from the afterglow regime of the discharge, where the cross section for electron attachment increases. The formation of negative ions from sputtering of metals and metal oxides is compared with that for positive ions. It is shown that the negative ion signals of F? and TaO2F? are enhanced relative to positive ion signals and can be used to study the distribution of a tantalum fluoride layer within the anodized tantala layer. Further, comparison is made with data obtained using glow-discharge optical emission spectroscopy, where elemental fluorine can only be detected using a neon plasma. The ionization mechanisms responsible for the formation of negative ions in glow discharge time-of-flight mass spectrometry are briefly discussed.  相似文献   

2.
Glycocholic acid (GCA) has been identified as endogenous biomarker for hepatocellular carcinoma (HCC). To dissolve protein and liberate GCA from protein, ionic liquids (ILs) that contain chaotropic ions were used for pretreatment of liquid biological samples. Coupling with solid-phase extraction (SPE) and reversed-phase high-performance liquid chromatography (RP-HPLC), the novel sample pretreatment method was applied for quantitative determination of GCA in urine and plasma samples. Compared with the traditional organic solvents pretreatment of biological samples, the proposed method is “greener” and simpler, due to no use of volatile organic solvent, and avoiding centrifugation. Under the optimal conditions, when the GCA-free urine and plasma samples were spiked with GCA at 0.05–1.0 and 0.2–10 μmol L?1, the recoveries of GCA ranged between 95.8–101.6 and 96.9–100.4%, respectively. These procedures only required 1 mL of urine and 3 mL of 3 mM ILs aqueous solution and 100 μL of plasma and 4 mL of 2 mM ILs aqueous solution, respectively. The proposed method has been successfully validated on a small sample size of 14 HCC patients and 14 healthy volunteers. For HCC patients, the mean concentration of GCA was 24.79 ± 6.86 and 31.98 ± 11.12 μmol L?1 in urine and plasma samples, and was about 3 times and 24 times as much as in healthy people, respectively. The proposed method opens up a new possibility in early diagnosis of HCC.  相似文献   

3.
Beclomethasone dipropionate (BDP) is a potent pro-drug to beclomethasone (BOH) and is used in the treatment of chronic and acute respiratory disorders in the horse. The therapeutic dose of BDP (325 microg per horse) by inhalation results in very low plasma and urinary concentrations of BDP and its metabolites that pose a challenge to detection and confirmation by equine forensic laboratories. To solve this problem, a method involving the use of a liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) was developed for the detection, confirmation and quantification of the analytes in equine samples. Ammonium formate or acetate buffer added to LC mobile phase favored the formation of [M + H](+) ions from BDP and its metabolites, whereas formic acid led to the formation of sodium and potassium adduct ions ([M + Na](+), [M + K](+)) together with [M + H](+) ions. Acetonitrile, on the other hand, favored the formation of abundant solvent adduct ions [M + H + CH(3)CN](+) with the analytes under electrospray ionization (ESI) and atmospheric pressure chemical ionization conditions. In contrast, methanol formed much less solvent adduct ions than acetonitrile. The solvent adduct ions were thermally stable and could not be completely desolvated under the experimental conditions, but they were very fragile to collision-induced dissociation (CID). Interestingly, these solvent adduct ions were observed on a triple-quadrupole mass spectrometry but not on an ion trap instrument where helium used as a damping gas in the ion trap might cause the solvent adduct ions desolvated by collision. By CID studies on the [M + H](+) ions of BDP and its metabolites, their fragmentation paths were proposed. In equine plasma at ambient temperature over 2 h, BDP and B21P were hydrolyzed in part to B17P and BOH, respectively, but B17P was not hydrolyzed. Sodium fluoride added to equine plasma inhibited the hydrolysis of BDP and B21P. The matrix effect in ESI was evaluated in equine plasma and urine samples. The method involved the extraction of BDP and its metabolites from equine plasma and urine samples by methyl tert-butyl ether, resolution on a C(8) column with a mobile phase gradient consisting of methanol and ammonium formate (2 mmol l(-1), pH 3.4) and multiple reaction monitoring for the analytes on a triple-quadrupole mass spectrometer. The detection limit was 13 pg ml(-1) for BDP and B17P, 25 pg ml(-1) for BOH and 50 pg ml(-1) for B21P in plasma and 25 pg ml(-1) for BOH in urine. The method was successfully applied to the analysis of equine plasma and urine samples for the analytes following administration of BDP to horses by inhalation. B17P, the major and active metabolite of BDP, was detected and quantified in equine plasma up to 4 h post-administration by inhalation of a very low therapeutic dose (325 microg per horse) of BDP.  相似文献   

4.
Microwave plasma torch (MPT) is a simple and low power‐consumption ambient ion source. And the MPT Mass spectra of many metal elements usually exhibit some novel features different from their inductively coupled plasma (ICP) mass spectra, which may be helpful for metal element analysis. Here, we presented the results about the MPT mass spectra of copper and molybdenum elements by a linear ion trap mass spectrometer (LTQ). The generated copper or molybdenum contained ions in plasma were characterized further in collision‐induced dissociated (CID) experiments. These researches built a novel, direct and sensitive method for the direct analysis of trace levels of copper and molybdenum in aqueous liquids. Quantitative results showed that the limit of detection (LOD) by using MS2 procedure was estimated to be 0.265 µg/l (ppb) for copper and 0.497 µg/l for molybdenum. The linear dynamics ranges cover at least 2 orders of magnitude and the analysis of a single aqueous sample can be completed in 5–6 min with a reasonable semi‐quantitative sense. Two practical aqueous samples, milk and urine, were also analyzed qualitatively with reasonable recovery rates and RSD. These experimental data demonstrated that the MPT MS is able to turn into a promising and hopeful tool in field analysis of copper and molybdenum ions in water and some aqueous media, and can be applied in many fields, such as environmental controlling, hydrogeology, and water quality inspection. Moreover, MPT MS could also be used as the supplement of ICP‐MS for the rapid and in‐situ analysis of metal ions. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
The present paper proposes a pre-concentration procedure for determination of lead and iron in several samples by flame atomic absorption spectrometry. In it, lead(II) and iron(III) ions are coprecipitated using the violuric acid-copper(II) system as collector. Afterwards, the precipitate is dissolved with 1 M HNO3 solution and the metal ions are determined. The optimization step was performed using factorial design involving the variables: pH, violuric acid mass (VA) and copper concentration (Cu).Using the optimized experimental conditions, the proposed procedure allows the determination these metals with detection limits of 0.18 μg L−1 for iron and 0.16 μg L−1 for lead. The effects of foreign ions on the pre-concentration procedure were also evaluated and the results demonstrated that this method could be applied for determination of iron and lead in several real samples. The proposed method was successfully applied to the analysis of seawater, urine, mineral water, soil and physiological solution samples. The concentrations of lead and iron achieved in these samples agree well with others data reported in the literature.  相似文献   

6.
A gas chromatography–mass spectrometric method was developed in this study in order to determine fluoride in plasma and urine after derivatization with 2-(bromomethyl)naphthalene. 2-Fluoronaphthalene was chosen as the internal standard. The derivatization of fluoride was performed in the biological sample and the best reaction conditions (10.0 mg mL−1 of 2-(bromomethyl)naphthalene, 1.0 mg mL−1 of 15-crown-5-ether as a phase transfer catalyst, pH of 7.0, reaction temperature of 70 °C, and heating time of 70 min) were established. The organic derivative was extracted with dichloromethane and then measured by a gas chromatography–mass spectrometry. Under the established condition, the detection limits were 11 μg L−1 and 7 μg L−1 by using 0.2 mL of plasma or urine, respectively. The accuracy was in a range of 100.8–107.6%, and the precision of the assay was less than 4.3% in plasma or urine. Fluoride was detected in a concentration range of 0.12–0.53 mg L−1 in six urine samples after intake of natural mineral water containing 0.7 mg L−1 of fluoride.  相似文献   

7.
Li M  Li DW  Li YT  Xu DK  Long YT 《Analytica chimica acta》2011,701(2):157-163
A novel and facile hybrid analytical method coupling electrochemical “adsorption–desorption” and colorimetric analyses was developed to detect heavy metal ions in turbid water samples. The target metal ions were deposited onto an electrode inserted into the original sample, which was referred to as the “adsorption” process. After changing the medium, the concentrated target metal ions were dissolved in a new, clean buffer (blank buffer), which was referred to as the “desorption” process. The concentrations of the target metal ions were measured by colorimetric analyses after the addition of specific indicator amounts. We demonstrated the applicability of this method by detecting Cd2+, Pb2+ and Cu2+ with co-depositing Bi3+ on portable screen-printed electrodes (SPEs). A good correlation (correlation coefficient of R = 0.997) was observed between concentrations ranging from 1 to 200 μM and absorbance values. After the multiple “desorption” process, the even better detection limits as low as 10, 10 and 100 nM were achieved for Cd2+, Pb2+ and Cu2+, respectively. The practicality of this hybrid method was confirmed by the detection of Cd2+, Pb2+ and Cu2+ in wastewater samples, and these results were in agreement with inductively coupled plasma atomic emission spectroscopy (ICP-AES). Overall, this hybrid method provides a simple, selective and effective technique for environmental pollutant analyses.  相似文献   

8.
Xu  Fan  Xu  Guili  Shang  Beicheng  Yu  Fang 《Chromatographia》2009,69(11):1421-1426

A simple, specific and sensitive liquid chromatographic method has been developed for the assay of ketorolac in human plasma and urine. The clean-up of plasma and urine samples were carried out by protein precipitation procedure and liquid–liquid extraction, respectively. Separation was performed by a Waters sunfire C18 reversed-phase column maintained at 35 °C. The mobile phase was a mixture of 0.02 M phosphate buffer (pH adjusted to 4.5 for plasma samples and to 3.5 for urine samples) and acetonitrile (70:30, v/v) at a flow rate of 1.0 mL min−1. The UV detector was set at 315 nm. Nevirapine was used as an internal standard in the assay of urine sample. The method was validated over the concentration range of 0.05–8 and 0.1–10 μg mL−1 for ketorolac in human plasma and urine, respectively. The limits of detection were 0.02 and 0.04 μg mL−1 for plasma and urine estimation at a signal-to-noise ratio of 3. The limits of quantification were 0.05 and 0.1 μg mL−1 for plasma and urine, respectively. The extraction recoveries were found to be 99.3 ± 4.2 and 80.3 ± 3.7% for plasma and urine, respectively. The intra-day and inter-day standard deviations were less than 0.5. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This assay demonstrated to be applicable for clinical pharmacokinetic studies.

  相似文献   

9.
Fan Xu  Guili Xu  Beicheng Shang  Fang Yu 《Chromatographia》2009,69(11-12):1421-1426
A simple, specific and sensitive liquid chromatographic method has been developed for the assay of ketorolac in human plasma and urine. The clean-up of plasma and urine samples were carried out by protein precipitation procedure and liquid–liquid extraction, respectively. Separation was performed by a Waters sunfire C18 reversed-phase column maintained at 35 °C. The mobile phase was a mixture of 0.02 M phosphate buffer (pH adjusted to 4.5 for plasma samples and to 3.5 for urine samples) and acetonitrile (70:30, v/v) at a flow rate of 1.0 mL min?1. The UV detector was set at 315 nm. Nevirapine was used as an internal standard in the assay of urine sample. The method was validated over the concentration range of 0.05–8 and 0.1–10 μg mL?1 for ketorolac in human plasma and urine, respectively. The limits of detection were 0.02 and 0.04 μg mL?1 for plasma and urine estimation at a signal-to-noise ratio of 3. The limits of quantification were 0.05 and 0.1 μg mL?1 for plasma and urine, respectively. The extraction recoveries were found to be 99.3 ± 4.2 and 80.3 ± 3.7% for plasma and urine, respectively. The intra-day and inter-day standard deviations were less than 0.5. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This assay demonstrated to be applicable for clinical pharmacokinetic studies.  相似文献   

10.
Nitrogen doped nano porous graphene was used as an efficient sorbent in solid‐phase extraction process for simultaneous separation and pre‐concentration of metal ions lead (II), cadmium(II), and chromium(III)) in biological samples. Ultrasonic assisted in‐syringe dispersive micro solid phase extraction coupled with micro sampling atomic absorption spectrometry was utilized for the determination of metal ions. Nitrogen doped nano porous graphene was synthesized as a nano sorbent by chemical vapour deposition method. Methane and aniline were used as carbon and nitrogen sources. The characterization of sorbent was performed by field emission scanning electron microscope, transmission electron microscopy, atomic force microscope, fourier transform infrared, chemical element analysis and raman analysis. Effective parameters on the extraction efficiency such as pH, sorbent dosage, eluent volume and eluent concentration were optimized by central composite design and desirability function. Experimental results indicate that the optimal conditions for this extraction were pH = 6.4, 1.42 mg of sorbent, 100 μL of eluent, and 0.84 mol L‐1 of eluent concentration. The detection limits are as low as 1.5, 0.3 and 0.9 μg L‐1 for lead, cadmium, and chromium, respectively. The intra‐day precisions were 3.6, 4.38 and 2.94 and Inter‐day precision were 4.83, 5.26 and 4.52 for lead, cadmium, and chromium, respectively. Method performance was investigated by determination of mentioned heavy metals in complicated biological matrixes such as human plasma, urine and saliva samples with good recoveries.  相似文献   

11.
A new cetyl‐alcohol‐reinforced hollow fiber solid/liquid‐phase microextraction (CA–HF–SLPME) followed by high‐performance liquid chromatography–diode array detection (HPLC–DAD) method was developed for simultaneous determination of ezetimibe and simvastatin in human plasma and urine samples. To prepare the CA–HF–SLPME device, the cetyl‐alcohol was immobilized into the pores of a 2.5 cm hollow fiber micro‐tube and the lumen of the micro‐tube was filled with 1‐octanol with the two ends sealed. Afterwards, the prepared device was introduced into 10 mL of the sample solution containing the analytes with agitation. Under optimized conditions, calibration curves plotted in spiked plasma and urine samples were linear in the ranges of 0.363–25/0.49–25 μg L?1 for ezetimibe/simvastatin and 0.193–25/0.312–25 μg L?1 for ezetimibe/simvastatin in plasma and urine samples, respectively. The limit of detection was 0.109/0.174 μg L?1 for ezetimibe/simvastatin in plasma and 0.058/0.093 μg L?1 for ezetimibe/simvastatin in urine. As a potential application, the proposed method was applied to determine the concentration of selected analytes in patient plasma and urine samples after medication and satisfactory results were achieved. In comparison with reference methods, the CA–HF–SLPME–HPLC–DAD method demonstrates considerable potential in the biopharmaceutical analysis of selected drugs.  相似文献   

12.
A new multi‐component chemosensor system comprising a naphthalimide moiety as fluorophore is designed and developed to investigate receptor–analyte binding interactions in the presence of metal and non‐metal ions. A dimethylamino moiety is utilized as receptor for metal ions and a thiourea receptor, having acidic protons, for binding anions. The system is characterized by conventional analytical methods. The absorption and fluorescence spectra of the system consist of a broad band typical for an intramolecular charge transfer (ICT). The effects of various metal‐ion additives on the spectral behavior of the present sensor system are examined in acetonitrile. It is found that among the metal ions studied, alkali/alkaline earth‐metal ions and transition‐metal ions modulate the absorption and fluorescence spectra of the system. As an additional feature, the anion signaling behavior of the system in acetonitrile is studied. A decrease in fluorescence efficiency of the system is observed upon addition of fluoride and acetate anions. Fluorescence quenching is most effective in the case of fluoride ions. This is attributed to the enhancement of the photoinduced electron transfer from the anion receptor to the fluorophore moiety. Hydrogen‐bond interactions between the acidic NH protons of the thiourea moiety and the F? anions are primarily attributed to the fluoride‐selective signaling behavior. Interestingly, a negative cooperativity for the binding event is observed when the interactions of the system are studied in the presence of both Zn2+ and F? ions. NMR spectroscopy and theoretical calculations are also carried out to better understand the receptor–analyte binding.  相似文献   

13.
Viscose fibers were treated with atmospheric pressure dielectric barrier discharge (DBD) plasma obtained in nitrogen in order to activate the fiber surface prior to sorption of the divalent ions Ca2+ and Cu2+. Methylene blue sorption was used for estimation of carboxyl group formation on the surface after DBD plasma treatment, through the degree of fabric staining (K/S). Sorption of divalent ions was performed from solutions of each individual ion and from solutions of calcium and copper in succession onto untreated and plasma-treated viscose samples. The quantity of sorbed metal was determined from the neutralization and iodometric titration method. Scanning electron microscopy coupled with energy dispersive X-ray analysis was used for fiber morphology and surface characterization before and after plasma treatment, and after metal ions sorption. Experiments revealed copper microparticles formation on the fiber surface when sorption of copper was performed on samples with bonded calcium. Further analysis confirmed that for growth of copper particles, both calcium ions and nitrogen DBD plasma pretreatments are necessary.  相似文献   

14.
A novel chelating ligand, 2,4-[bis-(2,4-dihydroxybenzylidene)]-dihydrazinoquinazoline (DBHQ), was synthesized, and the fluorescence characteristics of its complex with metal ions were investigated.Thirty-five different metal ions were tested for the emission of fluorescence in the presence of DBHQ in aqueous solutions in a pH range of 3.0-10.5 (at a difference of 0.5 for each metal).It was observed that DBHQ fluoresces intensely at 470 nm with an excitation wavelength of 405 nm in the presence of Ga3+ or Al3+ in the pH range 3.0-4.0. The other metal ions did not show fluorescence with DBHQ. Although the presence of Cu2+, Co2+ and Fe3+ decreased the fluorescence intensity of DBHQ-Ga3+, the addition of a fluoride ion (NaF) recovered the fluorescence by masking the interfering ions. In addition, the fluoride ions were found to enhance the sensitive determination of Ga3+ because the fluorescence intensity of DBHQ-Ga3+ was further increased approximately 2.5-fold in the presence of F (? = 0.658) from that in the absence of F (? = 0.401). The fluoride ions also masked the Al3+ ions, which emit fluorescence on chelation with DBHQ. Therefore, a selective and sensitive detection of Ga3+ was achieved by using DBHQ in the presence of F. The detection limit of Ga3+ was approximately 50 nmol L−1 (3.5 ppb). The proposed method was applicable to determine Ga3+ in river water.  相似文献   

15.
An extractive‐spectrophotometric method based on the bleaching effect of F? ions on the iron (III)‐thiocyanate complex extracted into methyl iso‐butyl keton (MIBK) is proposed for the determination of fluoride ions in natural waters. This method is a simple and rapid method and there is no need for special and expensive reagents. The experimental conditions such as SCN? concentration, pH and kind of solvent were optimized, and we found that 0.15 M SCN?, pH = 5 and MIBK are the best selections. Limit of detection is 0.1 mg F?/L with a linear dynamic range 0.5–7 mg/L which covers optimum concentration of F? ions in drinking water (0.7–1.2 mg/L). Interference of Fe3+ and Al3+ ions was easily eliminated by the extractive procedure using a solution of oxine in chloroform. Finally, the proposed method was used in determination of fluoride content of some real water samples and the obtained results compared with those obtained from the standard method. No significant differences were observed between them.  相似文献   

16.
《Electrophoresis》2017,38(3-4):533-539
In this study, an optimized method using capillary electrophoresis (CE) with a direct contactless conductivity detector (C4D) for a new application field is presented for the quantification of fluoride in common used lithium ion battery (LIB) electrolyte using LiPF6 in organic carbonate solvents and in ionic liquids (ILs) after contacted to Li metal. The method development for finding the right buffer and the suitable CE conditions for the quantification of fluoride was investigated. The results of the concentration of fluoride in different LIB electrolyte samples were compared to the results from the ion‐selective electrode (ISE). The relative standard deviations (RSDs) and recovery rates for fluoride were obtained with a very high accuracy in both methods. The results of the fluoride concentration in the LIB electrolytes were in very good agreement for both methods. In addition, the limit of detection (LOD) and limit of quantification (LOQ) values were determined for the CE method. The CE method has been applied also for the quantification of fluoride in ILs. In the fresh IL sample, the concentration of fluoride was under the LOD. Another sample of the IL mixed with Li metal has been investigated as well. It was possible to quantify the fluoride concentration in this sample.  相似文献   

17.
A new solid-phase extraction method utilising polyacrylonitrile activated carbon fibres (PAN-ACFs) as adsorbent was developed for the preconcentration of trace metal ions prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The PAN-ACFs oxidised with nitric acid were characterised by FT-IR, XRD, SEM and BET analysis. Then the resulting PAN-ACFs were used as solid-phase adsorbent for simultaneously determination of trace Al(III), Be(II), Bi(III), Cr(III), Cu(II), Fe(III) and Pb(II) ions in aqueous solutions. The influences of the analytical parameters on the recoveries of the studied ions were investigated. The optimum experimental conditions of the proposed method were pH: 6.0; eluent concentration and volume: 3.0 mL of 1.5 mol L?1 nitric acid; flow rates of sample and eluent solution: 1.5 mL min?1. The preconcentration factors were found to be 67 for Al(III), Bi(III); 83 for Cr(III), Cu(II), Fe(III) and 50 for Be(II), Pb(II). The precision of this method was in range of 1.5%~3.5% and the detection limit of this metal ions was between 0.06~1.50 μg L?1. The developed method was validated by the analysis of a certified reference sample and successfully applied to the determination of trace metal ions in water samples with satisfactory results.  相似文献   

18.
Li J  Zhang Y  Cai W  Shao X 《Talanta》2011,84(3):679-683
Analysis of metal ions in environment is of great importance for evaluating the risk of heavy metal to public health and ecological safety. A method for simultaneous determination of metal ions in water samples was developed by using adsorption preconcentration and near-infrared diffuse reflectance spectroscopy (NIRDRS). A high capacity adsorbent of thiol-functionalized magnesium phyllosilicate, named Mg-MTMS, was prepared by co-condensation for preconcentration of Hg2+, Pb2+ and Cd2+ in aqueous solutions. After adsorbing the analytes onto the adsorbent, NIRDRS was measured and PLS models were established for fast and simultaneous quantitative prediction. Because the interaction of the ions with the functional group of the adsorbent can be reflected in the spectra, the models built with the samples prepared by river water were proven to be efficient enough for precise prediction. The determination coefficients (R2) of the validation samples for the three ions were found as high as 0.9197, 0.9599 and 0.9861, respectively. Furthermore, because the high adsorption efficiency of Mg-MTMS, the detected concentrations are as low as milligrams per liter for the three ions, and the concentration can be further reduced. Therefore, the feasibility of quantitative analysis metal ions in river water by NIRDRS is proven and this may provide a new way for fast simultaneous determination of trace metals in environmental waters.  相似文献   

19.
The nickel–aluminum layered double hydroxide (Ni–Al LDH) was synthesized by a simple co-precipitation method with controlled pH and followed by hydrothermal treatment. The obtained nano-structured inorganic material was employed, for the first time, as a new solid-phase extraction (SPE) sorbent for the extraction and pre-concentration of trace levels of fluoride ions from aqueous solutions. An indirect method was used for monitoring of extracted fluoride ions. The method is based on the quenching effect of extracted fluoride ions upon the fluorescence intensity of Al–oxine complex via the forming of AlF63−, which was determined spectrofluorometrically at λem = 510 nm with excitation at λex = 404 nm. The effect of several parameters such as type of interlayer anion in Ni–Al LDH structure, pH, sample flow rate, elution conditions, amount of nano-sorbent, sample volume and co-existing ions on the extraction efficiency of the analyte were investigated. The results showed that fluoride ions could be retained on the Ni–Al (NO3) LDH at pH 6.0 and stripped by 1.2 mL of 3.0 mol L−1 NaOH. In the optimum experimental conditions, the limit of detection (3 s) and enrichment factor were 9.0 ng mL−1 and 50, respectively. The optimized method was successfully applied to the determination of fluoride concentration in various water samples. The results obtained from the proposed method were successfully compared with those provided by standard SPADNS method.  相似文献   

20.
High-performance differential pulse polarography is used for determining the antitumor antibiotic mitomycin C in human blood plasma and urine. The limit of determination (2-ml samples) is 25 ng ml?1 when the substance is isolated by means of Amberlite XAD-2, and 200 ng mo?1 when samples are not pretreated. The method was applied in a pharmacokinetic experiment; no metabolites of mitomycin C were observed in urine or plasma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号