首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Saito Y  Kawazoe M  Hayashida M  Jinno K 《The Analyst》2000,125(5):807-809
The direct coupling of in-tube solid-phase microextraction (in-tube SPME) with microcolumn liquid chromatography (micro-LC) has been investigated for the analysis of antidepressants in human urine. The use of in-tube SPME has been clearly shown to be advantageous for the on-line coupling of the SPME method, as the sample pretreatment technique, with micro-LC as the separation technique. This is because much smaller amounts of the sample solutions, desorption solvents and the mobile phase are required compared with conventional SPME-LC systems. The parameters for preconcentration have been investigated for the extraction capillary with the newly developed 'wire-in-tube' configuration.  相似文献   

2.
An automated on-line method for the determination of the isoflavones, daidzein and genistein, was developed using in-tube solid-phase microextraction coupled to high-performance liquid chromatography (in-tube SPME-HPLC). In-tube SPME is a new extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary by repeated draw/eject cycles of sample solution. Daidzein, genistein and their glucosides tested in this study were clearly separated within 8 min by HPLC using an XDB-C8 column with diode array detection. In order to optimize the extraction of these compounds, several in-tube SPME parameters were examined. The glucosides daidzin and genistin were analyzed as aglycones after hydrolysis because the glucosides were not concentrated by in-tube SPME. The optimum extraction conditions for daidzein and genistein were obtained with 20 draw/eject cycles of 40 microl of sample using a Supel-Q porous layer open tubular capillary column. The extracted compounds were easily desorbed from the capillary by mobile phase flow, and carryover was not observed. Using the in-tube SPME-HPLC method, the calibration curves of these compounds were linear in the range 5-200 ng/ml, with a correlation coefficient above 0.9999 (n = 18), and the detection limits (S/N = 3) were 0.4-0.5 ng/ml. This method was successfully applied to the analysis of soybean foods without interference peaks. The recoveries of aglycones and glucosides spiked into food samples were above 97%.  相似文献   

3.
Miniaturized solid-phase extraction (SPE) has been developed and successfully employed for the determination of organic species in water samples by liquid chromatography (LC). The method is based on the concept of a microscale extraction technique using a fused-silica capillary column for gas chromatography (GC), so-called in-tube solid-phase microextraction (SPME). The extraction conditions, such as the extraction time and flow-rate for the extraction and desorption process, were investigated as well as the effect of the internal structure of the extraction capillary on the efficiency. By inserting a stainless steel wire into the extraction capillary to reduce the internal volume of the capillary with the same surface area of the coating, an improved extraction and pre-concentration effects were obtained. Further pre-concentration was accomplished by the extraction device with a novel fiber-in-tube configuration. The direct coupling of the extraction method with a LC system has made it possible to determine low levels of phthalates in water samples without high consumption of organic solvents. The system developed must have potential applications for the analysis of environmental and biological samples in aqueous sample matrices.  相似文献   

4.
Sample preparation, such as extraction, concentration, and isolation of analytes, greatly influences their reliable and accurate analysis. In-tube solid-phase microextraction (SPME) is a new effective sample preparation technique using an open tubular fused-silica capillary column as an extraction device. Organic compounds in aqueous samples are directly extracted and concentrated into the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and they can be directly transferred to the liquid chromatographic column. In-tube SPME is an ideal sample preparation technique because it is fast to operate, easy to automate, solvent-free, and inexpensive. On-line in-tube SPME-performed continuous extraction, concentration, desorption, and injection using an autosampler, is usually used in combination with high performance liquid chromatography and liquid chromatography-mass spectrometry. This technique has successfully been applied to the determination of various compounds such as pesticides, drugs, environmental pollutants, and food contaminants. In this review, an overview of the development of in-tube SPME technique and its applications to environmental, clinical, forensic, and food analyses are described.  相似文献   

5.
Takino M  Daishima S  Nakahara T 《The Analyst》2001,126(5):602-608
A method for the determination of six chlorinated phenoxy acid herbicides in river water was developed using in-tube solid-phase microextraction (SPME) followed by liquid chromatography/electrospray ionization-mass spectrometry (LC/ESI-MS). In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from a sample directly into an open tubular capillary by repeated draw/eject cycles of the sample solution. Simple mass spectra with strong signals corresponding to [M-H]- and [M-RCOOH]- were observed for all herbicides tested in this study. The best separation of these compounds was obtained with a C18 column using linear gradient elution with a mobile phase of acetonitrile-water containing 5 mmol l-1 dibutylamine acetate (DBA). To optimize the extraction of herbicides, several in-tube SPME parameters were examined. The optimum extraction conditions were 25 draw/eject cycles of 30 microliters of sample in 0.2% formic acid (pH 2) at a flow rate of 200 microliters min-1 using a DB-WAX capillary. The herbicides extracted by the capillary were easily desorbed by 10 microliters acetonitrile. Using in-tube SPME-LC/ESI-MS with time-scheduled selected ion monitoring, the calibration curves of herbicides were linear in the range 0.05-50 ng ml-1 with correlation coefficients above 0.999. This method was successfully applied to the analysis of river water samples without interference peaks. The limit of quantification was in the range 0.02-0.06 ng ml-1 and the limit of detection (S/N = 3) was in the range 0.005-0.03 ng ml-1. The repeatability and reproducibility were in the range 2.5-4.1% and 6.2-9.1%, respectively.  相似文献   

6.
Applications of solid-phase microextraction in food analysis   总被引:21,自引:0,他引:21  
Food analysis is important for the evaluation of the nutritional value and quality of fresh and processed products, and for monitoring food additives and other toxic contaminants. Sample preparation, such as extraction, concentration and isolation of analytes, greatly influences the reliable and accurate analysis of food. Solid-phase microextraction (SPME) is a new sample preparation technique using a fused-silica fiber that is coated on the outside with an appropriate stationary phase. Analyte in the sample is directly extracted to the fiber coating. The SPME technique can be used routinely in combination with gas chromatography (GC), GC–mass spectrometry (GC–MS), high-performance liquid chromatography (HPLC) or LC–MS. Furthermore, another SPME technique known as in-tube SPME has also been developed for combination with LC or LC–MS using an open tubular fused-silica capillary column as an SPME device instead of SPME fiber. These methods using SPME techniques save preparation time, solvent purchase and disposal costs, and can improve the detection limits. This review summarizes the SPME techniques for coupling with various analytical instruments and the applications of these techniques to food analysis.  相似文献   

7.
In-tube solid-phase microextraction (SPME) has successfully been coupled to capillary LC, and further an automated in-tube SPME system has been developed using a commercially available HPLC auto-sampler. However, an open tubular capillary column with a thick film of polymer (stationary phase) is unfavorable because the ratio of the surface area of coating layer contacted with sample solution to the volume of the capillary column is insufficient for mass transfer. A highly efficient SPME column is. therefore, required. We introduced a C18-bonded monolithic capillary column that was used for in-tube SPME. The column consisted of continuous porous silica having a double-pore structure. Both the through-pore and the meso-pore were optimized for in-tube SPME, and the optimized capillary column was connected to an HPLC injection valve for characterization. The results demonstrated that the pre-concentration efficiency is excellent compared with the conventional in-tube SPME. The novel method for both introduction and concentration of the samples was effective. satisfactory and suitable for use in the SPME medium.  相似文献   

8.
王欣  何坚刚  罗琪  刘震 《色谱》2020,38(1):137-142
自动化联用分析技术对于降低人力强度、提高效率和保证数据重现性等具有重要意义。硼亲和固相微萃取(BA-SPME)是近十年出现的用于富集顺式二羟基化合物的独特工具,但BA-SPME与高效液相色谱(HPLC)的自动化在线联用还未见报道。该文报道了一种新颖的管内BA-SPME-HPLC全自动在线联用方法,用于分析茶饮料中的顺式二羟基化合物。该自动化在线联用方法利用自动进样器通过六通阀的切换实现流路连接。制备了管内BA-SPME毛细管,考察了涂层柱的柱容量,并对其形貌进行了表征,考察并优化了影响实际样品分离效果的因素。最后,利用该联用方法对3种不同品牌的茶饮料进行了分析,并对沏茶温度对茶水中顺式二羟基化合物含量的影响进行了评价。  相似文献   

9.
Wu J  Lord H  Pawliszyn J 《Talanta》2001,54(4):655-672
A simple and sensitive method for the determination of amphetamine, methamphetamine and their methylenedioxy derivatives in urine and hair samples was developed by coupling automated in-tube solid phase microextraction (SPME) to high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ES-MS). To achieve optimum performance, the conditions for both the in-tube SPME and the ES-MS detection were investigated. ES-MS detection conditions were studied by flow injection analysis (FIA) with direct liquid injection. In-tube SPME conditions were optimized by selecting the appropriate extraction parameters, including capillary stationary phases and sample pH. For the compounds studied, a custom-made polypyrrole (PPY) coated capillary showed superior extraction efficiency as compared to commercial capillaries. Therefore, the PPY coated capillary was selected for in-tube SPME in this study. The calibration curves of stimulants were linear in the range from 0.1 to 100 ng ml(-1) with detection limits (S/N=3) of 8-56 ng l(-1). This method was successfully applied to the analysis of the stimulants in spiked human urine and hair samples.  相似文献   

10.
This paper compares the advantages and disadvantages of two different configurations for the extraction of triazines from water samples: (1) on-fibre solid-phase microextraction (SPME) coupled to conventional liquid chromatography (LC); and (2) in-tube SPME coupled to capillary LC. In-tube SPME has been effected either with a packed column or with an open capillary column. A critical evaluation of the main parameters affecting the performance of each method has been carried out in order to select the most suitable approach according to the requirements of the analysis. In the on-fibre SPME configuration the fibre coating was polydimethylsiloxane (PDMS)-divinylbenzene (DVB). The limits of detection (LODs) obtained with this approach under the optimized extraction and desorption conditions were between 25 and 125 microg/L. The in-tube SPME approach with a C18 packed column (35 mm x 0.5 mm I.D., 5 microm particle size) connected to a switching micro-valve provided the best sensitivity; under such configuration the LODs were between 0.025 and 0.5 microg/L. The in-tube SPME approach with an open capillary column coated with PDMS (30 cm x 0.25 mm I.D., 0.25 microm of thickness coating) connected to the injection valve provided LODs between 0.1 and 0.5 microg/L. In all configurations UV detection at 230 nm was used. Atrazine, simazine, propazine, ametryn, prometryn and terbutryn were selected as model compounds.  相似文献   

11.
Partition coefficients of benzene, toluene, ethylbenzene and xylenes (BTEX), between crosslinked polydimethylsiloxane and water, were determined at room temperature by capillary extraction (a form of in-tube solid-phase microextraction, SPME) coupled to open tubular gas chromatography (in-tube SPME-high-resolution GC). A series of 7-9 repetitive extractions, performed on a 1-ml volume of diluted aqueous BTEX sample by the double-syringe squeeze method, gave exponential regression curves which fit very well with those predicted by partition theory. From the equations of the curves of relative FID response vs. extraction number, experimental Kd were easily calculated and the results compared with literature values. The whole measurement requires about 1 h from the start of the experiment to the final calculation of all BTEX partition coefficients. In-tube SPME resulted in a fast, clean, efficient, and cheaper alternative than the classic 1-cm, externally coated, SPME fiber-holder technique.  相似文献   

12.
A new sample preparation and preconcentration technique - solid phase microextraction (SPME) - is reported for the application of several tinorganic compounds and tetrabutyllead in aqueous samples. The solvent-free procedure is rapid in comparison with liquid-liquid extraction or SFE but also sensitive. Analytical variables of the extraction such as adsorption and desorption time, stirring rate and temperature has been investigated. The determination has been performed by GC coupled with atomic emission detection (AED). After optimization of the conditions of SPME a calibration was realized on the basis of a multicomponent standard solution, prepared by ethylation of organotin salts directly in the sample using sodium tetraethylborate (NaBEt(4)) without prior separation of the analytes from the matrix. The method permits preconcentration. Values of about 10 can be reached. A detection limit of 0.09 pg Sn and 0.08 pg Pb can be achieved under optimized conditions. The proposed procedure has been successfully applied to the analysis of organotin compounds in various slurry samples.  相似文献   

13.
Miniaturized fiber-in-tube solid-phase extraction (fiber-in-tube SPE) has been developed as a solventless sample preconcentration technique for microcolumn liquid-phase separation methods. Short capillaries packed with polymer filaments were employed as the extraction tube and the preconcentration power for phthalates in aqueous solutions was studied. On the basis of the successful on-line coupling of this preconcentration method with liquid chromatography (LC), a more miniaturized extraction cartridge, which is installed in the rotor of the micro-injector, has been developed. With a modified commercially available valve, on-line coupling of this sample preconcentration method to capillary electrochromatography (CEC) was also investigated.  相似文献   

14.
<正>Urinary 8-hydroxy-2'-deoxyguanosine(8-OHdG) is an excellent marker of oxidative DNA damage.In this study,employing guanosine as dummy template a novel molecularly imprinted(MIP) monolithic capillary column had been synthesized,and that was used as medium of in-tube solid phase microextraction(SPME).Coupled with capillary electrophoresis-electrochemical detection(CE-ECD),the system of extraction and detection of 8-OHdG in urinary sample had been developed.Because of its greater phase ratio combined with convective mass transfer and inherent selectivity,the MIP monolithic column exhibited high extraction efficiency on target analyte with the limit of detection(LOD) and quantity(LOQ) reached 2.6 nmol/L(S/N = 3) and 8.6 nmol/L(S/N= 10),respectively.The linear range was from 10 nmol/L to 1.5μmol/L(r = 0.9999) with relative standard deviation(RSD) 3.7%for peak current,and 0.5%for migration time,and the average recovery of spiked 20-200 nmol/L 8-OHdG was 85%±3.5%(n = 6).This highly sensitive method was applied to analysis of 8-OHdG in urinary samples from healthy volunteers,coking plant workers and lung cancer patients.  相似文献   

15.
Wu J  Xie W  Pawliszyn J 《The Analyst》2000,125(12):2216-2222
A polypyrrole (PPY) coated capillary and several commercially available capillaries (capillary GC columns) were used to evaluate their extraction efficiencies for catechins and caffeine. Compared with commercial capillaries that were currently used for in-tube solid phase microextraction (SPME), the PPY coated capillary showed better extraction efficiency for all of the compounds studied. Electrospray mass spectrometric (ES-MS) detection conditions were also investigated. After optimization of the extraction and detection conditions, a method for the sensitive and selective determination of catechins and caffeine was developed by coupling the PPY coated capillary in-tube SPME with HPLC-ES-MS. Catechins could be determined in both positive and negative ion detection modes. The detection limit (S/N = 3) for each of the studied catechins was < 0.5 ng mL-1. Caffeine could only be determined under positive ES-MS detection conditions and its detection limit was 0.01 ng mL-1. Caffeine and the five catechins in several tea samples were determined using the developed method. Small amounts of catechins were also detected in grape juice and wine samples.  相似文献   

16.
A new sample preparation and preconcentration technique – solid phase microextraction (SPME) – is reported for the application of several tinorganic compounds and tetrabutyllead in aqueous samples. The solvent-free procedure is rapid in comparison with liquid-liquid extraction or SFE but also sensitive. Analytical variables of the extraction such as adsorption and desorption time, stirring rate and temperature has been investigated. The determination has been performed by GC coupled with atomic emission detection (AED). After optimization of the conditions of SPME a calibration was realized on the basis of a multicomponent standard solution, prepared by ethylation of organotin salts directly in the sample using sodium tetraethylborate (NaBEt4) without prior separation of the analytes from the matrix. The method permits preconcentration. Values of about 10 can be reached. A detection limit of 0.09 pg Sn and 0.08 pg Pb can be achieved under optimized conditions. The proposed procedure has been successfully applied to the analysis of organotin compounds in various slurry samples.  相似文献   

17.
This paper describes a method for the selective screening of organophosphorus pesticides in water. In-tube solid-phase microextraction (SPME) in an open capillary column coupled to capillary liquid chromatography (LC) with UV detection has been used to effect preconcentration, separation and detection of the analytes in the same assembly. For in-tube SPME two capillary columns of the same length and different internal diameters and coating thicknesses have been tested and compared, a 30 cm x 0.25 mm I.D., 0.25 micro m thickness coating column, and a 30 cm x 0.1 mm I.D., 0.1 micro m of coating thickness column. In both columns the coating was 95% dimethylpolysiloxane (PDMS)-5% diphenylpolysiloxane. The proposed methodology provided limits of detections (LODs) for the tested organophosphorus pesticides in the 0.1-10 micro g/L range, whereas the direct injection of the samples onto the capillary LC system provided LODs in the 50-1000 micro g/L range. The sensitivity of the proposed in-tube SPME-capillary LC method is adequate to monitorize the analyte levels in drinking water. Several triazines, polycyclic aromatic hydrocarbons (PAHs), nonylphenol, organochloride pesticides or polybrominated diphenyl ethers (PBDEs) have been evaluated as possible interferents. The reliability of the described method is demonstrated by analysing different real water samples.  相似文献   

18.
Wen Y  Wang Y  Feng YQ 《Talanta》2006,70(1):153-159
An on-line simple and rapid method for the simultaneous determination of tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and doxycycline (DC) residues in fish muscle was developed by coupling in-tube solid-phase microextraction (SPME) to high-performance liquid chromatography (HPLC) with a photodiode array detector. Biocompatible poly (methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary was selected as the extraction medium, and no precipitating protein and removing fat steps were required prior to extraction. In order to optimize the extraction of these compounds, several in-tube SPME parameters were investigated. Simply performed by extracting with 0.01 M EDTA-MacIlvaine buffer solution (pH 4.0) and centrifugation, the sample then could be directly injected into the device for extraction. The limits of detection of tetracycline, oxytetracycline, chlortetracycline and doxycycline were calculated to be 22, 16, 30 and 21 ng/g, respectively. The calibration curves showed linearity in the range of 100-10,000 ng/g with a linear coefficient R2 value above 0.9980. Excellent method reproducibility was found by intra- and inter-day precisions, yielding the R.S.D.s less than 4.22% and 5.71%, respectively.  相似文献   

19.
A simple, rapid and sensitive on-line method for the simultaneous determination of benzoic and sorbic acids in food was developed by coupling in-tube solid-phase microextraction (SPME) to high-performance liquid chromatography (HPLC) with UV detection. The diethylamine-modified poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolithic capillary selected as the extraction medium exhibited a high extraction capability towards benzoic and sorbic acids. To obtain optimum extraction performance, several in-tube SPME parameters were investigated, including pH value, inorganic salt, and the organic solvent content of the sample matrix. After simple dilution with 0.02 mol/L phosphate solution (pH 4.0), carbonated drink, juice drink, sauce and jam samples could be directly injected for extraction. For succade samples, a small amount of acetonitrile was required to extract analytes prior to dilution and subsequent extraction. The linearity of the method was investigated over a concentration range of 5–20000 ng/mL for both analytes, and the correlation coefficients (R 2 values) were higher than 0.999. The detection limits for benzoic and sorbic acids were 1.2 and 0.9 ng/mL, respectively. The method reproducibility was tested by evaluating the intra- and interday precisions; relative standard deviations of less than 4.4 and 9.9%, respectively, were obtained. Recoveries of compounds from spiked food samples ranged from 84.4 to 106%. The developed method was shown to be suitable for the routine monitoring of benzoic and sorbic acids in various types of food samples.  相似文献   

20.
Boronate affinity solid phase microextraction (BA-SPME) is a new format appeared recently with great potential for specific extraction of cis-diol-containing compounds. Unlike conventional SPME, BA-SPME relies on covalent interactions and thereby features with specific selectivity, eliminated matrix effect and manipulable capture/release. However, only on-fiber BA-SPME and its off-line combination with high performance liquid chromatography (HPLC) have been reported so far. In this study, we report on-line coupling of in-tube BA-SPME with HPLC-electrospray ionization tandem mass spectroscopy (in-tube BA-SPME-HPLC-ESI-MS/MS) for the specific and sensitive determination of cis-diol-containing biomolecules. A boronate affinity extraction phase was prepared onto the inner surface of the capillary by copolymerization of vinylphenylboronic acid (VPBA) and ethylene glycol dimethacrylate (EDMA). The extraction conditions were optimized by choosing appropriate extraction/desorption solutions and extraction time. The extraction capacity, linear range, reproducibility and life-time were investigated. The developed method was successfully applied for the determination of dopamine in urine samples. Since many cis-diol-containing compounds are of great biological importance, the in-tube BA-SPME-HPLC method can be a promising tool.  相似文献   