首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 502 毫秒
1.
The present paper describes the development of a method for the simultaneous determination of five hormonally active UV filters namely benzophenone-3 (BP3), 3-(4-methylbenzylidene) camphor (4MBC), 2-ethylhexyl 4-(dimethylamino) benzoate (OD-PABA), 2-ethylhexyl 4-methoxycinnamate (EHMC) and octocrylene (OC) by means of solid-phase extraction and gas chromatography–electron impact ionization–mass spectrometry. Under optimized conditions, this methodology achieved low method limits of detection (needed for clean waters, especially drinking water analysis), between 0.02 and 8.42 ng/L, and quantitative recovery rates higher than 73% in all cases. Inter- and intraday precision for all compounds were lower than 7% and 11%, respectively. The optimized methodology was applied to perform the first survey of UV absorbing compounds in tap water from the metropolitan area and the city of Barcelona (Catalonia, Spain). In addition, other types of clean water matrices (mineral bottled water, well water and tap water treated with an ion-exchange resin) were investigated as well. Results evidenced that all the UV filters investigated were detected in the water samples analyzed. The compounds most frequently found were EHMC and OC. Maximum concentrations reached in tap water were 290 (BP3), 35 (4MBC), 110 (OD-PABA), 260 (EHMC), and 170 ng/L (OC). This study constitutes the first evidence of the presence of UV filter residues in tap water in Europe.  相似文献   

2.
Sun protection is an important part of our lives. UV filters are widely used to absorb solar radiation in sunscreens. However, excess UV filters constitute persistent groups of organic micropollutants present in the environment. An environmentally friendly ionic‐liquid‐based up‐and‐down shaker‐assisted dispersive liquid?liquid microextraction device combined with ultra‐performance liquid chromatography coupled with photodiode‐array detection has been developed to preconcentrate three UV filters (benzophenone, 2‐hydroxy‐4‐methoxybenzophenone, 2,2′‐dihydroxy‐4‐methoxybenzophenone) from field water samples. In this method, the optimal conditions for the proposed extraction method were: 40 μL [C8MIM][PF6] as extraction solvent and 200 μL methanol as disperser solvent were used to extract the UV filters. After up‐and‐down shaking for 3 min, the aqueous solution was centrifuged at 5000 rpm speed, then using microtube to collect the settled extraction solvent and using ultra‐performance liquid chromatography for further analysis. Quantification results indicated that the linear range was 2–1000 ng/mL. The LOD of this method was in the range 0.2–1.3 ng/mL with r2 ≥ 0.9993. The relative recovery in studies of different types of field water samples was in the range 92–120%, and the RSD was 2.3–7.1%. The proposed method was also applied to the analysis of field samples.  相似文献   

3.
A reliable and robust analytical method based on solid phase extraction (SPE) and high performance liquid chromatography (HPLC) with ultraviolet (UV) detector was developed for the simultaneous determination of five cephalosporin antibiotics (Ceftazidime, Cefradine, Cefaclor, Cefotaxime and Cefoperazone) in various water samples. Under optimised conditions, it was applicable to preconcentrate up to 500?ml of water samples in the OASIS HLB cartridges with reasonable recoveries for all the cephalosporin antibiotics tested. Recoveries were as follows: deionised water, tap water and groundwater, between 84.2 and 98.9%; surface water, between 71.2 and 81.0%; influent and effluent of wastewater treatment plant (WWTP), between 56.9 and 72.1%. The method detection limits (MDLs) for different water samples were in the range of 26 to 59?ng?l?1. Real water samples were analysed using the proposed approach to demonstrate the applicability and validation. Negative results were obtained for the tap water and groundwater. However, all the selected cephalosporin antibiotics were identified in the influent and effluent of a local WWTP at ng?l?1–µg?l?1 level. In addition, Ceftazidime was found in surface water with a concentration of 0.75–2.60?µg?l?1. The results indicate that the ‘pseudo-persistent’ contamination of cephalosporin antibiotics in the water environment could not be neglected.  相似文献   

4.
A portable sample preparation device with a magnetic polymer monolith as the extraction medium was constructed. The monolith was synthesized by polymerizing methacrylic acid and ethylene dimethacrylate around a cylindrical magnet. In this way, the monolith with a magnetic core could be readily attached to the extraction device by magnetism. The constructed device was evaluated for the enrichment of UV filters in water samples, followed by high‐performance liquid chromatographic analysis. The extraction efficiency for the targets was satisfactory with no matrix interference. Good linearities were obtained for the UV filters with the correlation coefficients >0.9986. The limits of detection and quantification for the UV filters were 0.3–0.8 and 1.0–2.4 ng/mL, respectively. The recoveries of the UV filters from the spiked water samples at the concentration of 100 ng/mL were 95.3–101.7%, with relative standard deviations <10%. Accordingly, the proposed portable device was demonstrated to be suitable for on‐site simultaneous sampling, purification, and preconcentration within a single step.  相似文献   

5.
This study describes a procedure for determining eight benzophenone-derived compounds in surface waters and sediments. These include the pharmaceutical ketoprofen, its phototransformation products 3-ethylbenzophenone and 3-acetylbenzophenone, and five benzophenone-type ultraviolet (UV) filters. The proposed analytical method involves the pre-concentration of water samples by solid-phase extraction (SPE) and microwave-assisted extraction (MAE) of sediment samples followed by derivatization and analysis by gas chromatography–mass spectrometry. Different parameters were investigated to achieve optimal method performance. Recoveries of 91 to 96 % from water samples were obtained using HLB Oasis SPE cartridges, whereas MAE of sediments (30 min at 150 °C) gave recoveries of 80 to 99 %. Limits of detection were between 0.1 and 1.9 ng L?1 for water samples and from 0.1 to 1.4 ng g?1 for sediment samples. The developed method was applied to environmental samples and revealed the presence of UV filters in the majority of the surface waters with up to 690 ng L?1 of 2-hydroxy-4-methoxybenzophenone. By contrast, ketoprofen (≤2,900 ng L?1) and its degradation products (≤320 ng L?1) were found in only two rivers, both receiving wastewater treatment plant effluents. Sediment analysis revealed benzophenone to be present in concentrations up to 650 ng g?1, whereas concentrations of other compounds were considerably lower (≤32 ng L?1). For the first time, quantifiable amounts of two ketoprofen transformation products in the aqueous environment are reported.  相似文献   

6.
HPLC method for quantitative determination of four preservatives and nine UV filters worldwide authorized in commercial suncare product was developed and validated, and then 101 samples of commercial suncare products were analyzed for the UV filters and preservatives using the proposed method. The mobile phase was acetonitrile-water containing 0.5% acetic acid using a gradient elution at a flow rate of 0.9 mL/min and UV measurements were carried out at 320 nm for UV filters and 254 nm for preservatives. The correlation coefficients of each calibration curves were mostly higher than 0.999. The percent relative standard deviations (%RSD) ranged from 0.97% to 6.1% for five sample aliquots. The recoveries from the spiked solutions were 98-102%. 2-ethylhexyl-p-methoxycinnamate (EHMC) was detected in 96 of 101 commercial suncare products and the concentration was in the range of 3.08-8.16% and 18 samples were found to exceed the 7.5% which has been defined as the maximum allowed concentration in Korea. Methyl paraben was detected in 81 of 101 samples and the next-most often detected preservatives were propyl paraben (25), ethyl paraben (18), and butyl paraben (4). Three samples of 101 suncare products exceeded the maximum allowed concentration (i.e., 0.58-0.79%). The proposed HPLC method allows efficient and simultaneous analysis of preservatives and UV filters suitable for quality control assays of commercial suncare products.  相似文献   

7.
An oriented titanium‐nickel oxide composite nanotubes coating was in situ grown on a nitinol wire by direct electrochemical anodization in ethylene glycol with ammonium fluoride and water for the first time. The morphology and composition of the resulting coating showed that the anodized nitinol wire provided a titania‐rich coating. The titanium‐nickel oxide composite nanotubes coated fiber was used for solid‐phase microextraction of different aromatic compounds coupled to high‐performance liquid chromatography with UV detection. The titanium‐nickel oxide composite nanotubes coating exhibited high extraction capability, good selectivity, and rapid mass transfer for weakly polar UV filters. Thereafter the important parameters affecting extraction efficiency were investigated for solid‐phase microextraction of UV filters. Under the optimized conditions, the calibration curves were linear in the range of 0.1–300 μg/L for target UV filters with limits of detection of 0.019–0.082 μg/L. The intraday and interday precision of the proposed method with the single fiber were 5.3–7.2 and 5.9–7.9%, respectively, and the fiber‐to‐fiber reproducibility ranged from 6.3 to 8.9% for four fibers fabricated in different batches. Finally, its applicability was evaluated by the extraction and determination of target UV filters in environmental water samples.  相似文献   

8.
An environmentally-friendly analytical method for the simultaneous determination of 15 fat-soluble ultraviolet (UV) filters currently authorized by the European Union regulation on cosmetic products has been developed. The determination was performed by liquid chromatography with UV spectrophotometric detection. Different parameters, such as type of column, oven temperature, mobile phase composition and flow rate were studied. The best chromatographic separation was obtained under the following conditions: C18 column set at 60 °C and gradient ethanol:water (containing 1% formic acid and 20 mM of 2-hydroxypropyl-β-cyclodextrin) as mobile phase pumped at 1 mL min−1. 2-Hydroxypropyl-β-cyclodextrin was added as mobile phase modifier to achieve the complete resolution of some of the chromatographic peaks. The 15 target compounds were separated in less than 30 min. The method was satisfactorily validated by analyzing three laboratory-made cosmetic samples besides of eleven commercially available cosmetic products containing different combination of the target UV filters. Good accordance of the found levels compared with those of the laboratory-made samples and those of the commercial samples (when available) was achieved. Moreover, excellent recoveries (97–104%) and good intra-day and inter-day precision values at different concentration levels, besides limits of detection values below the μg mL−1 level, were obtained. These good analytical features, as well as their environmentally-friendly characteristics, make the presented method suitable not only for routine analysis in cosmetics industries, but also as candidate reference method for sunscreen analysis.  相似文献   

9.
A field-amplified sample injection–capillary zone electrophoresis (FASI-CZE) method for the analysis of benzophenone (BP) UV filters in environmental water samples was developed, allowing the separation of all compounds in less than 8 min. A 9- to 25-fold sensitivity enhancement was obtained with FASI-CZE, achieving limits of detection down to 21–59 μg/L for most of the analyzed BPs, with acceptable run-to-run and day-to-day precisions (relative standard deviations lower than 17 %). In order to remove water sample salinity and to enhance FASI sensitivity, an off-line solid-phase extraction (SPE) procedure using a Strata X polymeric reversed-phase sorbent was used and afforded recoveries up to 72–90 % for most BPs. With the combination of off-line SPE and FASI-CZE, limits of detection in the range 0.06–0.6 μg/L in a river water matrix, representing a 2,400- to 6,500-fold enhancement, were obtained. Method performance was evaluated by quantifying a blank river water sample spiked at 1 μg/L. For a 95 % confidence level, no statistical differences were observed between found concentrations and spiked concentrations (probability at the confidence level, p value, of 0.60), showing that the proposed off-line SPE-FASI-CZE method is suitable for the analysis of BP UV filters in environmental water samples at low microgram per liter levels. The method was successfully applied to the analysis of BPs in river water samples collected up- and downstream of industrialized and urban areas, and in some drinking water samples.  相似文献   

10.
Ultraviolet filters (UV Filters) are compounds that are widely employed in personal care products such as sunscreens to protect the skin from sun damage, but they are also added to other products, such as food packaging, plastics, paints, textiles, detergents, etc. The continuous use of these products causes the release of a substantial amount of these products into the marine environment through direct input or wastewater discharge, and thus they are becoming an important class of contaminants of emerging concern. A correlation between their occurrence and different negative effects on marine biota has been reported.Taking into account all the possible impacts on the environment, knowledge of their presence and distribution in the different compartments of the ecosystems, ranging from waters and sediments to aquatic organisms, which potentially suffer from bioaccumulation and biomagnification processes, is essential. High concentrations of ultraviolet filters have been found in samples collected from across the entire planet, even in polar regions, revealing their global distribution.Therefore, interest in the sensitive determination of ultraviolet filters in several marine matrices has increased. In this article, an overall review of the more recently reported analytical chemistry methods for identifying and quantifying these compounds in marine environmental samples is presented. We compare and discuss the potential advantages and disadvantages of every step involved in the analytical procedure, including the pre-treatment, treatment and extraction processes that are required to avoid matrix effects. Moreover, we describe the worldwide occurrence and distribution of those most important UV filters.  相似文献   

11.
Disinfection is an important step in the purification of drinking and swimming pool water. The most common procedure includes chlorination, which efficiently eliminates microorganisms. However, the reaction of active chlorine with dissolved organic matter produces numerous organochlorine compounds posing a hazard to the environment and human health. UV filters belong to emerging contaminants, as their application to skin protection from UV irradiation becomes increasingly popular all over the world. Certain components of UV filters were detected in swimming pools and result in the emergence of new ecotoxicants. In the present study, 40 compounds, including numerous brominated derivatives, which result from the chlorination of avobenzone in sea water, were identified by gas chromatography–high resolution mass spectrometry. In addition, the applicability of photocatalysis to the destruction of chlorination products was studied. The procedure was found to be rather efficient and allows a decrease in the total amount of avobenzone transformation products by a factor of 10. The only compound class demonstrating stability under the applied conditions is exemplified by halogenated acetophenone derivatives.  相似文献   

12.
A sensitive method of CZE‐ultraviolet (UV) detection based on the on‐line preconcentration strategy of field‐amplified sample injection (FASI) was developed for the simultaneous determination of five kinds of chlorophenols (CPs) namely 4‐chlorophenol (4‐CP), 2‐chlorophenol (2‐CP), 2,4‐dichlorophenol (2,4‐DCP), 2,4,6‐trichlorophenol (2,4,6‐TCP), and 2,6‐dichlorophenol (2,6‐DCP) in water samples. Several parameters affecting CZE and FASI conditions were systematically investigated. Under the optimal conditions, sensitivity enhancement factors for 4‐CP, 2‐CP, 2,4‐DCP, 2,4,6‐TCP, and 2,6‐DCP were 9, 27, 35, 43, and 43 folds, respectively, compared with the direct CZE, and the baseline separation was achieved within 5 min. Then, the developed FASI‐CZE‐UV method was applied to tap and lake water samples for the five CPs determination. The LODs (S/N = 3) were 0.0018–0.019 µg/mL and 0.0089–0.029 µg/mL in tap water and lake water, respectively. The values of LOQs in tap water (0.006–0.0074 µg/mL) were much lower than the maximum permissible concentrations of 2,4,6‐TCP, 2,4‐DCP, and 2‐CP in drinking water stipulated by World Health Organization (WHO) namely 0.3, 0.04, and 0.01 µg/mL, respectively, and thereby the method was suitable to detect the CPs according to WHO guidelines. Furthermore, the method attained high recoveries in the range of 83.0–119.0% at three spiking levels of five CPs in the two types of water samples, with relative standard deviations of 0.37–8.58%. The developed method was proved to be a simple, sensitive, highly automated, and efficient alternative to CPs determination in real water samples.  相似文献   

13.
A new method using gas chromatography-tandem mass spectrometry (GC-MS/MS) was developed for the determination of four benzotriazoles, i.e. benzotriazole (BT), 5-methylbenzotriazole (5-TTri), 5-chlorobenzotriazole (CBT), 5,6-dimethylbenzotriazole (XTri), and six UV filters, i.e. benzophenone-3 (BP-3), 3-(4-methylbenzylidene)camphor (4-MBC), octyl 4-methoxycinnamate (OMC), 2-(3-t-butyl-2-hydroxy-5-methylphenyl)-5-chloro benzotriazole (UV-326), 2-(2'-hydroxy-5'-octylphenyl)-benzotriazole (UV-329), and octocrylene (OC) in ground water, effluent and biosolid samples. Solid phase extraction (SPE) and pressurized liquid extraction (PLE) were applied as the preconcentration method for water samples (ground water and effluent) and biosolid samples, respectively. The optimized method allowed us to quantify all target compounds with the method detection limits ranging from 0.29 to 11.02 ng/L, 0.5 to 14.1 ng/L and 0.33 to 8.23 ng/g in tap water, effluent and biosolid samples, respectively. The recoveries of the target analytes in tap water, effluent and biosolid samples were 70-150%, 82-127% and 81-133%, respectively. The developed analytical method was applied in the determination of these target compounds in ground water, effluent and biosolid samples collected from Bolivar sewage treatment plants in South Australia. In effluent samples, the target compounds BT, 5-TTri, CBT, XTri and BP-3 tested were detected with the maximum concentration up to 2.2 μg/L for BT. In biosolid samples, eight out of ten compounds tested were found to be present at the concentrations ranging between 18.7 ng/g (5-TTri) and 250 ng/g (4-MBC).  相似文献   

14.
Based on TiO2-nanoparticles coating fabricated by a one-step anodization method on titanium wire substrate, a novel phenyl functionalized solid-phase microextraction (SPME) fiber coating was prepared by simple and rapid in situ chemical assembling technique between the fiber surface titanol groups and trichlorophenylsilane reaction. The as-fabricated fiber exhibited good extraction capability for some UV filters and was employed to determine the ultraviolet (UV) filters in combination with high performance liquid chromatography–UV detection (HPLC–UV). The main parameters affecting extraction performance were investigated and optimized. Under the optimized conditions, the developed method was applied to detect several UV filters at trace concentration levels with only 8 mL of sample volume. They were determined in the range from 0.005 to 25 μg L−1 with detection limits (S/N = 3) from 0.1 to 50 ng L−1. The relative standard deviations (RSDs) for single fiber repeatability varied from 4.6 to 6.5% (n = 5) and fiber-to-fiber reproducibility (n = 5) ranged from 5.5 to 9.1%. The linear ranges spanned two-four magnitudes with correlation coefficients above 0.9990. Five real water samples including four Yellow River water samples and one rain water sample were determined sensitively with good recoveries ranging from 86.2 to 105.5%. The functionalized fiber coating performed good reproducible manner, high mechanical strength, good stability and long service life. Moreover, this study proposed an efficient sample pretreatment method for the determination of UV filters from environmental water samples.  相似文献   

15.
Deep eutectic solvents are considered as new and green solvents that can be widely used in analytical chemistry such as microextraction. In the present work, a new dl‐ menthol‐based hydrophobic deep eutectic solvent was synthesized and used as extraction solvents in an air‐assisted dispersive liquid–liquid microextraction method for preconcentration and extraction of benzophenone‐type UV filters from aqueous samples followed by high‐performance liquid chromatography with diode array detection. In an experiment, the deep eutectic solvent formed by dl‐ menthol and decanoic acid was added to an aqueous solution containing the UV filters, and then the mixture was sucked up and injected five times by using a glass syringe, and a cloudy state was achieved. After extraction, the solution was centrifuged and the upper phase was subjected to high‐performance liquid chromatography for analysis. Various parameters such as the type and volume of the deep eutectic solvent, number of pulling, and pushing cycles, solution pH and salt concentration were investigated and optimized. Under the optimum conditions, the developed method exhibited low limits of detection and limits of quantitation, good linearity, and precision. Finally, the proposed method was successfully applied to determine the benzophenone‐type filters in environmental water samples with relative recoveries of 88.8–105.9%.  相似文献   

16.
A non-aqueous reversed-phase high performance liquid chromatographic method (RP-HPLC) with UV detection at 313 nm was developed and validated for simultaneous determination of methylene bis-benzotriazolyl tetramethylphenol (Tinosorb M) along with three other chemical UV filters, octocrylene (Eusolex OCR), octyl methoxycinnamate (Eusolex 2292) and octyl salicylate (Eusolex OS) in suncare products. An isocratic elution was performed on a Hypersil BDS RP-C18 column (250 mm x 4.6 mm), 5 microm particle size, using a mobile phase consisted of methanol-acetonitrile (90:10, v/v) with a flow-rate of 1.5 ml/min. The determination of the four UV filters was not interfered by the excipients in the products. The method of external standard, as well as the standard addition method was used for the determination. The external standard calibration curves were linear for Eusolex OCR, Eusolex 2292, Eusolex OS, and Tinosorb M in the concentration ranges of 0.5-100 microM, 0.5-100 microM, 0.5-200 microM, and 0.2-100 microM, respectively. Day-to-day relative standard deviation of the determination was within 3%. Limits of detection and quantitation of the above compounds were found equal to 36 and 110 nM, 220 and 660 nM, 170 and 520 nM, 44 and 130 nM, respectively. The recovery of these four chemical UV filters from the spiked samples was 96-103%.  相似文献   

17.
A novel method has been developed to simultaneously determine and quantify seven organic UV filters employing liquid (solid)-liquid extraction, derivatization with N-methyl-N-(trimethylsilyl) trifluoroacetamide (MSTFA) and gas chromatography with mass spectrometric detection in various environmental matrices. The UV filters determined were: benzophenone (BP), benzhydrol (BH), 4-hydroxybenzophenone (HBP), 2-hydroxy-4-methoxybenzophenone (HMB), 2,4-dihydroxybenzophenone (DHB), 2,2'-dihydroxy-4-methoxybenzophenone (DHMB) and 2,3,4-trihydroxylbenzophenone (THB). Under optimal conditions, the analysis required 23 min and good linearity over the range of 10-2,500 ng/L in water and 100-25,000 ng/kg in soil for each UV filter obtained. The high recovery (62-114% and 60-125% for water and soil samples, respectively) and the low RSD values (less than 13.9 and 17.2% for water and soil samples, respectively) indicated the high performance of this method. The method detection limits (MDLs) were relatively low, ranging from 5 to 100 ng/L or kg and quantification limits ranged between 25 and 500 ng/L or kg for all test compounds. This validated method was applied in the analysis of seven BP-type UV filters collecting water and soil samples in Korea, between April and May 2003. The overall concentration of UV filters in the soil sample (500-18,380 ng/kg) was highly distributed in water sample (27-204 ng/L). The established method was successfully applied to monitor the residue measurement of the BP-type UV filters in environmental water and soil samples.  相似文献   

18.
This paper describes the development and validation of a method for the simultaneous determination of 53 multi-class emerging organic pollutants in water samples using solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS), using electrospray ionisation (ESI) in both positive and negative modes. Target compounds include acidic herbicides, UV filters, insect repellents, organophosphorous flame retardants, a bactericide, pharmaceuticals and metabolites. A single SPE consisting on the loading of 200-500 mL of sample adjusted to pH 7 on Oasis HLB 200mg cartridges and elution with methanol, permitted obtaining good recoveries: higher than 60% for tap, surface and wastewater in most cases. The 7 isotopically labelled internal standards effectively compensated losses during sample preparation and matrix effects at LC-MS/MS determination. The precision of the method, calculated as relative standard deviation (RSD) was below 15% for all compounds and all tested matrices. Detection limits (LODs) based on the confirmation, less intense, MRM (multiple reaction monitoring) transition and considering blanks varied between 0.3 and 30 ngL(-1). Finally, the developed method was applied to the determination of target analytes in various samples, including tap, surface and waste water. Among the tested emerging pollutants, 31 were found in wastewater in concentrations reaching up to 10 microgL(-1) in the case of ibuprofen. Also, 13 species were detected in tap water with concentrations up to 0.13 microgL(-1) for tri(chloropropyl) phosphate (TCPP).  相似文献   

19.
UV filters are a group of compounds commonly used in different cosmetic products to absorb UV radiation. They are classified into a variety of chemical groups, such as benzophenones, salicylates, benzotriazoles, cinnamates, p-aminobenzoates, triazines, camphor derivatives, etc. Different tests have shown that some of these chemicals are absorbed through the skin and metabolised or bioaccumulated. These processes can cause negative health effects, including mutagenic and cancerogenic ones. Due to the absence of official monitoring protocols, there is an increased number of analytical methods that enable the determination of those compounds in cosmetic samples to ensure user safety, as well as in biological fluids and tissues samples, to obtain more information regarding their behaviour in the human body. This review aimed to show and discuss the published studies concerning analytical methods for the determination of organic UV filters in cosmetic and biological samples. It focused on sample preparation, analytical techniques, and analytical performance (limit of detection, accuracy, and repeatability).  相似文献   

20.
In this research, a simple, sensitive chemiluminescence (CL) method for the determination of humic acid (HA) in water samples was first developed based on the redox reaction between humic acid and cerium(IV) in the acidic condition. Different with the former redox CL reaction which occurred in alkaline solution, no enhancers were needed and neither precipitation nor a second contamination would occur in the present CL system. Comparing with other spectrometric methods, we find that the proposed analysis system had better applicability and accuracy. Under the optimal experiment conditions, the CL peak height was linear with the concentration of HA in the range of 0.03 to 10.0 microg mL(-1). The detection limit is 0.01 microg mL(-1) (S/N = 3), and the relative standard deviation was 2.3% for 0.5 microg mL(-1) HA solution with eleven repeated measurements. The present CL method was successfully applied to the determination of HA in tap water, spring water and river water samples with good recovery from 90.0 to 110.0%. A possible CL mechanism was proposed based on the results of UV and fluorescence spectrometry and the CL spectrum of HA. It was speculated that the semi-quinone radicals in the excited state were the emitters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号