首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
A simple and high-throughput method for the identification of disulfide-containing peptides utilizing peptide-matrix adducts is described. Some commonly used matrices in MALDI mass spectrometry were found to specifically react with sulfhydryl groups within peptide, thus allowing the observation of the peptide-matrix adduct ion [M+n+n′ matrix+H]+ or [M+n+n′ matrix+Na]+ (n = the number of cysteine residues, n′=1, 2,…, n) in MALDI mass spectra after chemical reduction of disulfide-linked peptides. Among several matrices tested, α-cyano-4-hydroxycinnamic acid (CHCA, molecular mass 189 Da) and α-cyano-3-hydroxycinnamic acid (3-HCCA) were found to be more effective for MALDI analysis of disulfide-containing peptides/proteins. Two reduced cysteines involved in a disulfide bridge resulted in a mass shift of 189 Da per cysteine, so the number of disulfide bonds could then be determined, while for the other matrices (sinapinic acid, ferulic acid, and caffeic acid), a similar addition reaction could not occur unless the reaction was carried out under alkaline conditions. The underlying mechanism of the reaction of the matrix addition at sulfhydryl groups is proposed, and several factors that might affect the formation of the peptide-matrix adducts were investigated. In general, this method is fast, effective, and robust to identify disulfide bonds in proteins/peptides.  相似文献   

2.
Our previous study showed that selenamide reagents such as ebselen and N-(phenylseleno)phthalimide (NPSP) can be used for selective and rapid derivatization of protein/peptide thiols in high conversion yield. This paper reports the systematic investigation of MS/MS dissociation behaviors of selenamide-derivatized peptide ions upon collision induced dissociation (CID) and electron transfer dissociation (ETD). In the positive ion mode, derivatized peptide ions exhibit tag-dependent CID dissociation pathways. For instance, ebselen-derivatized peptide ions preferentially undergo Se–S bond cleavage upon CID to produce a characteristic fragment ion, the protonated ebselen (m/z 276), which allows selective identification of thiol peptides from protein digest as well as selective detection of thiol proteins from protein mixture using precursor ion scan (PIS). In contrast, NPSP-derivatized peptide ions retain their phenylselenenyl tags during CID, which is useful in sequencing peptides and locating cysteine residues. In the negative ion CID mode, both types of tags are preferentially lost via the Se–S cleavage, analogous to the S–S bond cleavage during CID of disulfide-containing peptide anions. In consideration of the convenience in preparing selenamide-derivatized peptides and the similarity of Se–S of the tag to the S–S bond, we also examined ETD of the derivatized peptide ions to probe the mechanism for electron-based ion dissociation. Interestingly, facile cleavage of Se–S bond occurs to the peptide ions carrying either protons or alkali metal ions, while backbone cleavage to form c/z ions is severely inhibited. These results are in agreement with the Utah-Washington mechanism proposed for depicting electron-based ion dissociation processes.  相似文献   

3.
采用碱性新基质2-氨基-5-硝基噻唑对DNA和蛋白质样品进行了基质辅助激光解吸/电离飞行时间质谱分析.结果表明,2-氨基-5-硝基噻唑能有效地解吸电离DNA和蛋白质样品.采用正离子检测模式,分析分子量小于5000的pd(T)10,pd(C)10,pd(A)8,pd(G)10和pd(5′ATCGATCGAT3′)DNA样品时,分辨率均可达到1万以上;与分析DNA样品的常用基质相比,2-氨基-5-硝基噻唑解吸/电离样品分子所需要的激光强度小,易于获得信噪比和分辨率高及重复性好的谱图;分析蛋白质胰岛素、细胞色素C及牛血清白蛋白样品能达到与α-氰基-4-羟基肉桂酸(HCCA)和3,5-二甲氧基-4-羟基肉桂酸(SA)相同的效果.采用负离子检测模式则能以较高的信噪比获得分子量达到7000的DNA的分子离子峰信号.此外,以2-氨基-5-硝基噻唑为基质的基质辅助激光解吸/电离(MALDI)测定还表现出一定的耐盐能力.  相似文献   

4.
We previously reported the apparent formation of matrix adducts of 3,5-dimethoxy-4-hydroxy-cinnamic acid (sinapinic acid or SA) via covalent attachment to disulfide bond-containing proteins (HdeA, Hde, and YbgS) from bacterial cell lysates ionized by matrix-assisted laser desorption/ionization (MALDI) time-of-flight-time-of-flight tandem mass spectrometry (TOF-TOF-MS/MS) and post-source decay (PSD). We also reported the absence of adduct formation when using ??-cyano-4-hydroxycinnamic acid (CHCA) matrix. Further mass spectrometric analysis of disulfide-intact and disulfide-reduced over-expressed HdeA and HdeB proteins from lysates of gene-inserted E. coli plasmids suggests covalent attachment of SA occurs not at cysteine residues but at lysine residues. In this revised hypothesis, the attachment of SA is preceded by formation of a solid phase ammonium carboxylate salt between SA and accessible lysine residues of the protein during sample preparation under acidic conditions. Laser irradiation at 355?nm of the dried sample spot results in equilibrium retrogradation followed by nucleophilic attack by the amine group of lysine at the carbonyl group of SA and subsequent amide bond formation and loss of water. The absence of CHCA adducts suggests that the electron-withdrawing effect of the ??-cyano group of this matrix may inhibit salt formation and/or amide bond formation. This revised hypothesis is supported by dissociative loss of SA (?224?Da) and the amide-bound SA (?206?Da) from SA-adducted HdeA and HdeB ions by MS/MS (PSD). It is proposed that cleavage of the amide-bound SA from the lysine side-chain occurs via rearrangement involving a pentacyclic transition state followed by hydrogen abstraction/migration and loss of 3-(4-hydroxy-3,5-dimethoxyphenyl)prop-2-ynal (?206?Da).  相似文献   

5.
Matrix-assisted laser/desorption ionization (MALDI) mass-spectrometric imaging (MSI), also known as MALDI imaging, is a powerful technique for mapping biological molecules such as endogenous proteins and peptides in human skin tissue sections. A few groups have endeavored to apply MALDI-MSI to the field of skin research; however, a comprehensive article dealing with skin tissue sections and the application of various matrices and enzymes is not available. Our aim is to present a multiplex method, based on MALDI-MSI, to obtain the maximum information from skin tissue sections. Various matrices were applied to skin tissue sections: (1) 9-aminoacridine for imaging metabolites in negative ion mode; (2) sinapinic acid to obtain protein distributions; (3) α-cyano-4-hydroxycinnamic acid subsequent to on-tissue enzymatic digestion by trypsin, elastase, and pepsin, respectively, to localize the resulting peptides. Notably, substantial amounts of data were generated from the distributions retrieved for all matrices applied. Several primary metabolites, e.g. ATP, were localized and subsequently identified by on-tissue postsource decay measurements. Furthermore, maps of proteins and peptides derived from on-tissue digests were generated. Identification of peptides was achieved by elution with different solvents, mixing with α-cyano-4-hydroxycinnamic acid, and subsequent tandem mass spectrometry (MS/MS) measurements, thereby avoiding on-tissue MS/MS measurements. Highly abundant peptides were identified, allowing their use as internal calibrants in future MALDI-MSI analyses of human skin tissue sections. Elastin as an endogenous skin protein was identified only by use of elastase, showing the high potential of alternative enzymes. The results show the versatility of MALDI-MSI in the field of skin research. This article containing a methodological perspective depicts the basics for a comprehensive comparison of various skin states.
Figure
Matrix-assisted laser/desorption ionization (MALDI) mass-spectrometric imaging (MSI), also known as MALDI imaging, is a powerful technique for mapping biological molecules in human skin tissue sections. In this body of work, a multiplex method, based on MALDI-MSI, is presented to obtain maximum information from skin tissue sections. Therefore, various matrices were applied to skin tissue sections: (1) 9-aminoacridine (9-AA) for imaging small molecules in negative ion mode; (2) sinapinic acid (SA) to obtain protein distributions; (3) α-cyano-4-hydroxycinnamic acid (α-HCHA) subsequent to on-tissue enzymatic digestion by trypsin, elastase, and pepsin, respectively, to localize the resulting peptides. Of note, identification of metabolites was achieved by post-source decay (PSD) MALDI, and proteins were identified subsequent to enzymatic digestion via the resulting peptides which were eluted from the skin tissue section and afterwards analyzed with use of a tandem time-of-flight (ToF) mass spectrometer. The application of alternative enzymes, such as pepsin and elastase, is highlighted within this article  相似文献   

6.
Proteins in the nucleus accumbens mediate many cocaine‐induced behaviors. In an effort to measure changes in nucleus accumbens protein expression as potential biomarkers for addiction, coronal tissue sections were obtained from rats that developed behavioral sensitization after daily administration of cocaine, or from daily saline‐treated controls. The tissue sections were subjected to matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry (MS) profiling and tissue imaging. For profiling experiments, brain sections were manually spotted with matrix over the nucleus accumbens, a brain region known to regulate cocaine sensitization. Summed mass spectra (10 000 laser shots, grid) were acquired and spectra were aligned to reference peaks. Using bioinformatics tools, eight spectral features were found to be altered by cocaine treatment. Based on additional sequencing experiments with MALDI tandem MS and database searches of measured masses, secretoneurin (m/z 3653) was identified as having an increased expression. In addition, the distribution of m/z 3653 in the nucleus accumbens was determined by MALDI tissue imaging, and the increased expression of its precursor protein, secretogranin II, was verified by immunoblotting. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
MALDI imaging and profiling mass spectrometry of proteins typically leads to the detection of a large number of peptides and small proteins but is much less successful for larger proteins: most ion signals correspond to proteins of m/z < 25,000. This is a severe limitation as many proteins, including cytokines, growth factors, enzymes, and receptors have molecular weights exceeding 25 kDa. The detector technology typically used for protein imaging, a microchannel plate, is not well suited to the detection of high m/z ions and is prone to detector saturation when analyzing complex mixtures. Here we report increased sensitivity for higher mass proteins by using the CovalX high mass HM1 detector (Zurich, Switzerland), which has been specifically designed for the detection of high mass ions and which is much less prone to detector saturation. The results demonstrate that a range of different sample preparation strategies enable higher mass proteins to be analyzed if the detector technology maintains high detection efficiency throughout the mass range. The detector enables proteins up to 70 kDa to be imaged, and proteins up to 110 kDa to be detected, directly from tissue, and indicates new directions by which the mass range amenable to MALDI imaging MS and MALDI profiling MS may be extended.  相似文献   

8.
Highly homogenous α zein protein was isolated from maize kernels in an environment‐friendly process using 95% ethanol as solvent. Due to the polyploidy and genetic polymorphism of the plant source, the application of high resolution separation methods in conjunction with precise analytical methods, such as MALDI‐TOF‐MS, is required to accurately estimate homogeneity of products that contain natural zein protein. The α zein protein product revealed two main bands in SDS‐PAGE analysis, one at 25 kDa and other at 20 kDa apparent molecular mass. Yet, high resolution 2DE revealed approximately five protein spot groups in each row, the first at ca. 25 kDa and the second at ca. 20 kDa. Peptide mass fingerprinting data of the proteins in the two dominant SDS‐PAGE bands matched to 30 amino acid sequence entries out of 102 non‐redundant data base entries. MALDI‐TOF‐MS peptide mapping of the proteins from all spots indicated the presence of only α zein proteins. The most prominent ion signals in the MALDI mass spectra of the protein mixture of the 25 kDa SDS gel band after in‐gel digestion were found at m/z 1272.6 and m/z 2009.1, and the most prominent ion signals of the protein mixture of the 20 kDa band after in‐gel digestion were recorded at m/z 1083.5 and m/z 1691.8. These ion signals have been found typical for α zein proteins and may serve as marker ion signals which upon chymotryptic digestion reliably indicate the presence of α zein protein in two hybrid corn products.  相似文献   

9.
We have developed a technique combining acid hydrolysis with matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) for the rapid study of the changes in the levels of positive and negative acute phase protein biomarkers in the sera of patients suffering from major depression. The serum proteins were first precipitated using an organic solvent; after separation, they were subjected to hydrochloric acid hydrolysis (6 M HCl) for 10 min. The resulting peptides were characterized using MALDI‐TOF MS. Short‐term treatment of the serum proteins with HCl efficiently removed interference from the abundant protein – albumin – and produced abundant peptide ion signals in the range of m/z 4000–10 000. This approach allowed us to rapidly detect the peptide ions originating from transferrin (a common negative acute phase protein) and fibrinogen (a common positive acute phase protein). The average ratios and (standard deviations) of the ion signals derived from transferrin/fibrinogen were 3.58 (±1.93) for the healthy control subjects and 1.02 (±0.52) for the patients suffering from major depression. The differences in transferrin/fibrinogen ratios between healthy controls and patients suggest that major depression will induce internal inflammation and cause either an increase in the level of fibrinogen or a decrease in the level of transferrin. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
We describe experiments in MALDI-TOF and MALDI-TOF-TOF showing that the ejection of protein-matrix cluster ions and their partial decay in the source occur in MALDI. The use of radial beam deflection and small size detector in linear mode allows detection of ions with higher time-of-flight and kinetic energy deficit. MALDI-TOF-TOF experiments were carried out by selecting chemical noise ions at m/z higher than that of a free peptide ion. Whatever the selected m/z (up to m/z 300) the molecular peptide ion appeared as the main fragment. The production of protein-matrix clusters and their partial decay in the source was found to increase with the size of the protein (MW from 1000 to 150,000 u), although it decreases with increasing charge state. These effects were observed for different matrices (HCCA and SA) and in a large laser fluence range. Experimental results and calculation highlight that a continuous decay of protein-matrix cluster ions occurs in the source. This decay-desolvation process can account for the high-mass tailing and peak shifting as well as the strong noise/background in the mass spectra of proteins.  相似文献   

11.
We gauged the internal energy transfer for two dissociative ion decomposition channels in matrix-assisted laser desorption ionization (MALDI) using the benzyltriphenylphosphonium (BTP) thermometer ion [PhCH 2PPh 3] (+). Common MALDI matrixes [alpha-cyano-4-hydroxycinnamic acid (CHCA), 3,5-dimethoxy-4-hydroxycinnamic acid (sinapinic acid, SA), and 2,5-dihydroxycinnamic acid (DHB)] were studied with nitrogen laser (4 ns pulse length) and mode-locked 3 x omega Nd:YAG laser (22 ps pulse length) excitation. Despite the higher fluence required to initiate fragmentation, BTP ions indicated lower internal energy transfer with the picosecond laser in all three matrixes. These differences can be rationalized in terms of phase explosion induced by the nanosecond laser vs a stress-confinement-driven desorption mechanism for the picosecond laser. For the two ion production channels of the BTP thermometer ion, breaking a single bond can result in the formation of benzyl/tropylium ions, F1, or triphenylphosphine ions, F2. In SA and DHB, as well as in CHCA at low fluence levels, the efficiency of these channels (expressed by the branching ratio I F1/ I F2) is moderately in favor of producing tropylium ions, 1 < I F1/ I F2 < 6. As the laser fluence is increased, for CHCA, there is a dramatic shift in favor of the tropylium ion production, with I F1/ I F2 approximately 30 for the nanosecond and the picosecond laser, respectively. This change is correlated with the sudden increase in the BTP internal energies in CHCA in the same laser fluence range. The large changes observed in internal energy deposition for CHCA with laser fluence can account for its ability to induce fragmentation in peptides more readily than SA and DHB.  相似文献   

12.
In this work, we combined a newly developed matrix coating technique – matrix coating assisted by an electric field (MCAEF) and matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) to enhance the imaging of peptides and proteins in tissue specimens of human prostate cancer. MCAEF increased the signal‐to‐noise ratios of the detected proteins by a factor of 2 to 5, and 232 signals were detected within the m/z 3500–37500 mass range on a time‐of‐flight mass spectrometer and with the sinapinic acid MALDI matrix. Among these species, three proteins (S100‐A9, S100‐A10, and S100‐A12) were only observed in the cancerous cell region and 14 proteins, including a fragment of mitogen‐activated protein kinase/extracellular signal‐regulated kinase kinase kinase 2, a fragment of cAMP‐regulated phosphoprotein 19, 3 apolipoproteins (C‐I, A‐I, and A‐II), 2 S100 proteins (A6 and A8), β‐microseminoprotein, tumor protein D52, α‐1‐acid glycoprotein 1, heat shock protein β‐1, prostate‐specific antigen, and 2 unidentified large peptides at m/z 5002.2 and 6704.2, showed significantly differential distributions at the p < 0.05 (t‐test) level between the cancerous and the noncancerous regions of the tissue. Among these 17 species, the distributions of apolipoprotein C‐I, S100‐A6, and S100‐A8 were verified by immunohistological staining. In summary, this study resulted in the imaging of the largest group of proteins in prostate cancer tissues by MALDI‐MS reported thus far, and is the first to show a correlation between S100 proteins and prostate cancer in a MS imaging study. The successful imaging of the three proteins only found in the cancerous tissues, as well as those showing differential expressions demonstrated the potential of MCAEF‐MALDI/MS for the in situ detection of potential cancer biomarkers. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
Matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry was used for the rapid detection of cocaine, benzoylecgonine and cocaethylene in hair. Different MALDI sample preparation procedures have been tested and the employment of a multi-layer 'graphite-sample-electrosprayed alpha-cyano-4-hydroxycinnamic acid (HCCA)' yielded the best results for standard solutions of the target analytes. The same approach was subsequently applied to hair samples that were known to contain cocaine, benzoylecgonine and cocaethylene, as determined by a classical GC-MS method. It was however necessary to extract hair samples by incubating them in methanol/trifluoroacetic acid for a short time (15 min) at 45 degrees C; 1 microl of the obtained supernatant was deposed on a metal surface treated with graphite, and HCCA was electrosprayed on it. This procedure successfully suppressed matrix peaks and was effective in detecting all the target analytes as their protonated species. The results obtained give further confirmation of the effectiveness of the MALDI for detecting drugs and their metabolites in complex biological matrices. The method can be useful as a fast screening procedure to detect the presence of cocaine and metabolites in hair samples.  相似文献   

14.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) has been used successfully to detect phosphorylation sites in proteins. Applications may be limited by the low response of phosphopeptides compared to nonphosphorylated peptides in MALDI MS. The addition of ammonium salts to the matrix/analyte solution substantially enhances the signal for phosphopeptides. In examples shown for equimolar mixtures, the phosphorylated peptide peaks become the largest peaks in the spectrum upon ammonium ion addition. This can allow for the identification of phosphopeptides in an unfractionated proteolytic digestion mixture. Sufficient numbers of protonated phosphopeptides can be generated such that they can be subjected to postsource decay analysis, in order to confirm the number of phosphate groups present. The approach works well with the common MALDI matrices such as α-cyano-4-hydroxycinnamic acid and 2,5-dihydroxybenzoic acid, and with ammonium salts such as diammonium citrate and ammonium acetate.  相似文献   

15.
It has been described that ion yield in both positive- and negative-ion matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) of peptides is often inhibited by trace amounts of alkali metals and that the MALDI mass spectra are contaminated by the interfering peaks originating from traces of alkali metals, even when sample preparation is carefully performed. Addition of serine to the commonly used MALDI matrix alpha-cyano-4-hydroxycinnamic acid (CHCA) significantly improved and enhanced the signals of both protonated and deprotonated peptides, [M+H](+) and [M-H](-). The addition of serine to CHCA matrix eliminated the alkali-metal ion adducts, [M+Na](+) and [M+K](+), and the CHCA cluster ions from the mass spectra. Serine and serinephosphate as additives to CHCA enhanced and improved the formation of molecular-related ions of phosphopeptides in negative-ion MALDI mass spectra.  相似文献   

16.
Diagnosis of schizophrenia does not have a clear objective test at present, so we aimed to identify the potential biomarkers for the diagnosis of schizophrenia by comparison of serum protein profiling between first‐episode schizophrenia patients and healthy controls. The combination of a magnetic bead separation system with matrix‐assisted laser desorption/ionization time‐of‐flight tandem mass spectrometry (MALDI‐TOF/TOF‐MS) was used to analyze the serum protein spectra of 286 first‐episode patients with schizophrenia, 41 chronic disease patients and 304 healthy controls. FlexAnlysis 3.0 and ClinProToolsTM 2.1 software was used to establish a diagnostic model for schizophrenia. The results demonstrated that 10 fragmented peptides demonstrated an optimal discriminatory performance. Among these fragmented peptides, the peptide with m/z 1206.58 was identified as a fragment of fibrinopeptide A. Receiver operating characteristic analysis for m/z 1206.58 showed that the area under the curve was 0.981 for schizophrenia vs healthy controls, and 0.999 for schizophrenia vs other chronic disease controls. From our result, we consider that the analysis of serum protein spectrum using the magnetic bead separation system and MALDI‐TOF/TOF‐MS is an objective diagnostic tool. We conclude that fibrinopeptide A has the potential to be a biomarker for diagnosis of schizophrenia. This protein may also help to elucidate schizophrenia disease pathogenesis. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
We have performed a detailed characterization and identification of wheat gluten proteins obtained from the Teal variety of Canadian hard red spring wheat. RP-HPLC separation of the sample into 35 fractions has reduced the spectral complexity; this was followed by MALDI mass spectrometry (MS), which showed the presence of six or fewer resolved protein components above 20 kDa in each RP-HPLC fraction, giving a total of 93 MS resolved peaks. These included 17 peaks in the ω-gliadin fractions (F1–4), 12 in the high molecular weight (HMW) glutenin subunit fractions (F5–8), 59 in the α- and β-gliadins and low molecular weight (LMW) glutenin subunit fractions (F9–31) and 5 peaks in the γ-gliadin fractions (F32–35). Peptide maps of tryptic digests of HPLC fractions were obtained from a tandem quadrupole time-of-flight mass spectrometer (MALDI QqTOF MS) and were submitted to the ProFound search engine. HMW glutenin subunits including Ax2*, Dx5, Bx7, and Dy10 (consistent with the known profile of Teal), and LMW glutenin subunits including six from group 3 type II and 1 from group 2 type I, were identified with reasonable sequence coverage from HPLC fraction 5, 7, 17, and 18. The identities of the peptides attributed to selected gluten proteins were confirmed using MS/MS with BioMultiView to match the predicted and measured partial amino acid sequences. Because of incomplete wheat DNA databases, many wheat gluten proteins could not be identified. These results suggest that the combination of RP-HPLC with MS and MS/MS techniques is a promising approach for the characterization of wheat gluten proteins.  相似文献   

18.
Peptides with biological functions often contain disulfide bridges connecting two cysteine residues. In an attempt to screen biological fluids for peptides containing cysteine residues, we have developed a sensitive and specific method to label cysteines selectively and detect the resulting molecular mass shift by differential mass spectrometry. First, reduction of disulfide bridges and carboxyamidomethylation of free thiols is adjusted to quantitatively achieve cysteine alkylation for complex peptide extracts. In a second step, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) before and after chemical derivatization is performed, followed by differential analysis to determine shifted peaks; shifted peaks belong to cysteine-containing peptides, other peaks remain unchanged. The number of cysteines can then be determined by the resulting molecular mass shift. Free, reduced cysteines are shifted by 57 u, two oxidized cysteines involved in disulfide bridges (cystine) result in a shift to higher mass per disulfide bridge of 116 u. Disulfide bridges connecting different amino acid chains like insulin break up during reduction. In this case, two peaks with lower molecular masses result from a single one in the unmodified sample. With this technique, we were able to identify cysteine-containing peptides and short fragments of proteins present in human blood filtrate.  相似文献   

19.
The use of collision-induced dissociation, postsource decay (CID-PSD) matrix-assisted laser desorption/ionization (MALDI) mass spectrometry for the analysis of small organic molecules is demonstrated. Three pesticides: paraquat, diquat, and difenzoquat were chosen for this study. The matrices 2,5-dihydroxybenzoic acid (DHB), alpha-cyano-4-hydroxycinnamic acid (alpha-CHCA), and sinapinic acid (SA) were selected to investigate the effect of the matrix on the CID-PSD MALDI spectra of these molecules. Alpha-CHCA and DHB were found to be appropriate matrices for the pesticides studied. Spectra for a given pesticide obtained from different matrices were compared with each other, and the differences between them are discussed. A comparison of CID-PSD MALDI with fast-atom bombardment MS/MS spectra is presented; the agreement of pesticide fragmentation patterns between the two methods indicates that CID-PSD MALDI MS is a reliable and efficient technique for structural elucidation of small molecules.  相似文献   

20.
A strategy for the characterization of bacterial lipoprotein-in this case Braun’s lipoprotein (an outer membrane 7-ku lipoprotein) isolated from Escherichia coli—is described by time-of-flight mass spectrometric (TOF/MS) techniques [252Cf plasma desorption (PD) TOF/MS and matrix-assisted laser desorption-ionization (MALDI) TOF/MS]. Covalent linkage of lipid at the N-terminal cysteine (posttranslationally modified to a S-[2,3-bis(acyloxy)-propyl]-N-acylcysteine) and, therefore, strict insolubility in aqueous solution constitute common features for this class of proteins. Relative molecular mass determination of the major molecular species of Braun’s lipoprotein was obtained by selection of an appropriate mixture of organic solvents compatible with matrix/support materials useful for the mass spectrometric techniques applied. Minor components of this lipoprotein that differ only in the fatty acid composition of the lipid anchor were detected by PD TOF/MS after enzymatic release of the extremely hydrophobic N-terminal amino acid followed by selective extraction with chloroform. Part of the primary sequence of this lipoprotein was confirmed based on peptide fragment ions observed in the positive ion PD mass spectra of cyanogen bromide-generated peptide fragments that had been isolated previously by reverse phase high-performance liquid chromatography (HPLC). Peptidoglycan fragments that represent the attachment sites of lipoprotein to peptidoglycan were enzymatically released, separated by reverse phase HPLC, and finally characterized by time-of-flight mass spectrometric techniques (252Cf-PD TOF/MS, MALDI TOF/MS). The results obtained with both techniques differed only in the better sensitivity obtained with MALDI TOF/MS, which consumed a factor of 100 to 1000 less material than with PD TOF/MS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号