首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A headspace solid‐phase microextraction method was developed for the preconcentration and extraction of methyl tert‐butyl ether. An ionic‐liquid‐mediated multiwalled carbon nanotube–poly(dimethylsiloxane) hybrid coating, which was prepared by covalent functionalization of multiwalled carbon nanotubes with hydroxyl‐terminated poly(dimethylsiloxane) using the sol–gel technique, was used as solid‐phase microextraction adsorbent. This innovative fiber exhibited a highly porous surface structure, high thermal stability (at least 320°C) and long lifespan (over 210 uses). Potential factors affecting the extraction efficiency were optimized. Under the optimum conditions, the method LOD (S/N = 3) was 0.007 ng/mL and the LOQ (S/N = 10) was 0.03 ng/mL. The calibration curve was linear in the range of 0.03–200 ng/mL. The RSDs for one fiber (repeatability, n = 5) at three different concentrations (0.05, 1, and 150 ng/mL) were 5.1, 4.2, and 4.6% and for the fibers obtained from different batches (reproducibility, n = 3) were 6.5, 5.9, and 6.3%, respectively. The developed method was successfully applied to the determination of methyl tert‐butyl ether in different real water samples on three consecutive days. The relative recoveries for the spiked samples with 0.05, 1, and 150 ng/mL were between 94–104%.  相似文献   

2.
We developed a solid‐phase microextraction coupled to GC with electron‐capture detection method for the detection of acrylamide in food samples. Single‐walled carbon nanotubes and polypyrrole were electropolymerized onto a stainless‐steel wire as a coating, which possessed a homogeneous, porous, and wrinkled surface, chemical and mechanical stability, long lifespan (over 300 extractions), and good extraction efficiency for acrylamide. The linearity range between the signal intensity and the acrylamide concentration was found to be in the range 0.001–1 μg/mL, and the coefficient of determination was 0.9985. The LOD, defined as three times the baseline noise, was 0.26 ng/mL. The reproducibility for each single fiber (n = 6) and the fiber‐to‐fiber (n = 5) repeatability prepared in the same batch were less than 4.1 and 11.2%, respectively.  相似文献   

3.
An efficient analytical method called ionic‐liquid‐based ultrasound‐assisted in situ solvent formation microextraction followed by high‐performance liquid chromatography was developed for the determination of atenolol in human plasma. A hydrophobic ionic liquid (1‐butyl‐3‐methylimidazolium hexafluorophosphate) was formed by the addition of a hydrophilic ionic liquid (1‐butyl‐3‐methylimidazolium tetrafluoroborate) to a sample solution containing an ion‐pairing agent during microextraction. The analyte was extracted into the ionic liquid phase while the microextraction solvent was dispersed throughout the sample by utilizing ultrasound. The sample was then centrifuged, and the extracting phase retracted into the microsyringe and injected to liquid chromatography. After optimization, the calibration curve showed linearity in the range of 2–750 ng/mL with the regression coefficient corresponding to 0.998. The limits of detection (S/N = 3) and quantification (S/N = 10) were 0.5 and 2 ng/mL, respectively. A reasonable relative recovery range of 90–96.7% and satisfactory intra‐assay (4.8–5.1%, n = 6) and interassay (5.0–5.6%, n = 9) precision along with a substantial sample clean‐up demonstrated good performance of the procedure. It was applied for the determination of atenolol in human plasma after oral administration and some pharmacokinetic data were obtained.  相似文献   

4.
A new fiber based on the electrochemical reduction of graphene oxide was prepared on a copper wire for solid‐phase microextraction (SPME) applications. The prepared fiber was used for the SPME and gas chromatographic analysis of tricyclic antidepressants (TCADs), including amitriptyline, trimipramine, and clomipramine. The feasibility of direct‐immersion and headspace modes of SPME for the determination of TCADs was studied. The effects of four parameters including pH, salt content, extraction temperature with and without cooling the fiber, and extraction time were investigated. The comparison showed that headspace cold fiber SPME results in the best outcome for the extraction of TCADs. Under the optimized conditions of this mode, the calibration curves were linear between 2.0 and 500 ng/mL and the detection limits were between 0.30 and 0.53 ng/mL. The intraday and interday RSDs obtained at 20 ng/mL (n = 5), using a single fiber, were 5.5–9.0 and 7.5–9.8, respectively. The fiber to fiber repeatability (n = 4), expressed as the RSD, was between 12.8 and 13.2% at a 20 ng/mL concentration level. The method was successfully applied to the analysis of TCADs in plasma samples showing recoveries from 73 to 96%.  相似文献   

5.
A fast, sensitive, and centrifugeless ultrasound‐assisted emulsification microextraction followed by a high‐performance liquid chromatography method is developed for the determination of some phthalate esters in aqueous samples. In this method, a simple approach is followed to eliminate the centrifugation step in dispersive liquid–liquid microextraction using an organic solvent whose melting point is near the ambient temperature, consumption of the extracting solvent is efficiently reduced, and the overall extraction time was found to be only 7 min. The variables affecting the method are optimized. Under the optimal experimental conditions (75 μL of 1‐undecanol, a flow rate of 2.0 mL/min, and an ultrasound irradiation of 1 min), the proposed method exhibits good preconcentration factors (52–97), low limits of detection (1.0–5.0 ng/mL), and linearities in the range of 5–1500 ng/mL (r 2 ≥ 0.995). Finally, the method is successfully applied to the analysis of phthalate esters in the drinking and river water samples. To study the probable release of the phthalate esters from a polyethylene container into boiling water, the boiling water exposed to the polyethylene container was analyzed by the proposed method.  相似文献   

6.
For the first time, a polypyrrole–carbon nanotubes–silicon dioxide composite film coated on a steel wire was prepared by an electrochemical method. Scanning electron microscopy images showed that this composite film was even and porous. The prepared fiber was used as an absorbent for the headspace solid‐phase microextraction of benzene, toluene, ethylbenzene, and o‐xylene, followed by gas chromatographic analysis. This method presented an excellent performance, which was much better than that of a polypyrrole–carbon nanotube fiber. It was found that under the optimized conditions, the linear ranges were 0.01–200 ng/mL with correlation coefficients >0.9953, the detection limits were 0.005–0.020 ng/mL, the relative standard deviations were 3.9–6.4% for five successive measurements with a single fiber, and the reproducibility was 5.5–8.5% (n = 3). Finally, the developed method was successfully applied to real water samples, and the relative recoveries obtained for the spiked water samples were from 91.0 to 106.7%.  相似文献   

7.
We developed a CE and ultrasound‐assisted temperature‐controlled ionic liquid emulsification microextraction method for the determination of four parabens (methyl paraben, ethyl paraben, propyl paraben, and butyl paraben) in personal care products including mouthwash and toning lotion. In the proposed extraction procedure, ionic liquid (IL, 1‐octyl‐3‐methylimidazolium hexafluorophosphate) was used as extraction solvent, moreover, no disperser solvent was needed. Parameters affecting the extraction efficiency including volume of IL, heating temperature, ultrasonic time, extraction time, sample pH, ionic strength, and centrifugation time were optimized. Under the optimized conditions, the method was found to be linear over the range of 3–500 ng/mL with coefficient of determination (R2) in the range of 0.9990–0.9998. The LODs and LOQs for the four parabens were 0.45–0.72 ng/mL and 1.50–2.40 ng/mL, respectively. Intraday and interday precisions (RSDs, n = 5) were in the range of 5.4–6.8% and 7.0–8.7%, respectively. The recoveries of parabens at different spiked levels ranged from 71.9 to 119.2% with RSDs less than 9.5%.  相似文献   

8.
In this research, the headspace solid‐phase microextraction (SPME) coupled with GC flame ionization detector was applied for the determination of some monocyclic aromatic amines in real water and urine samples. A sol–gel technique was applied for the preparation of the SPME fibers. Two different sol–gel coatings, (PEG and poly(ethylene glycol) modified with multi‐walled carbon nanotubes [PEG/CNTs]), were prepared and compared. Extraction efficiency of PEG/CNTs was better than PEG fiber in the same conditions. To obtain maximum extraction efficiency, some parameters such as desorption temperature and time, temperature and time of extraction, salt effect, pH, and stirring speed were investigated and optimized for PEG/CNTs fiber. Under optimized conditions, the LODs (S/N = 3) were in the range of 0.5–50 ng/L and limits of quantification (S/N = 10) were between 1 and 500 ng/L. Repeatability (n = 5) was in the range of 3.2–9.1% and reproducibility (n = 3) was obtained from 5.5 to 12.0%. The method was successfully applied to the analysis of real water and urine samples with recoveries from 63.7 to 97.0%.  相似文献   

9.
In this work, two disperser‐free microextraction methods, namely, air‐agitated liquid–liquid microextraction and ultrasound‐assisted emulsification microextraction are compared for the determination of a number of polycyclic aromatic hydrocarbons in aqueous samples, followed by gas chromatography with flame ionization detection. The effects of various experimental parameters upon the extraction efficiencies of both methods are investigated. Under the optimal conditions, the enrichment factors and limits of detection were found to be in the ranges of 327–773 and 0.015–0.05 ng/mL for air‐agitated liquid–liquid microextraction and 406–670 and 0.015–0.05 ng/mL for ultrasound‐assisted emulsification microextraction, respectively. The linear dynamic ranges and extraction recoveries were obtained to be in the range of 0.05–120 ng/mL (R2 ≥ 0.995) and 33–77% for air‐agitated liquid–liquid microextraction and 0.05–110 ng/mL (R2 ≥ 0.994) and 41–67% for ultrasound‐assisted emulsification microextraction, respectively. To investigate this common view among some people that smoking hookah is healthy due to the passage of smoke through the hookah water, samples of both the hookah water and hookah smoke were analyzed.  相似文献   

10.
A zirconium terephthalate metal‐organic framework‐incorporated poly(N‐vinylcarbazole‐co‐divinylbenzene) monolith was fabricated in a capillary by a thermal polymerization method. The optimized monolith had a homogeneous structure, good permeability, and stability. The monolith could be used for the effective enrichment of fungicides through π‐π interactions, electrostatic forces, and hydrogen bonds. The potential factors that affect the extraction efficiency, including ionic strength, solution pH, sample volume, and eluent volume, were investigated in detail. The monolith‐based in‐tube solid‐phase microextraction coupled with ultra‐high‐performance liquid chromatography and high‐resolution Orbitrap mass spectrometry was performed for the analysis of five fungicides (pyrimethanil, tebuconazole, hexaconazole, diniconazole, and flutriafol) in environmental samples. Under the optimized conditions, the linear ranges were 0.005–5 ng/mL for pyrimethanil, 0.01–5 ng/mL for flutriafol, and 0.05–5 ng/mL for other fungicides, respectively, with coefficients of determination ≥0.9911. The limits of detection were 1.34–14.8 ng/L. The columns showed good repeatability (relative standard deviations ≤9.3%, n = 5) and desirable column‐to‐column reproducibility (relative standard deviations 5.3–9.4%, n = 5). The proposed method was successfully applied for the simultaneous detection of five fungicides in water and soil samples, with recoveries of 90.4–97.5 and 84.0–95.3%, respectively.  相似文献   

11.
Polyol‐enhanced dispersive liquid–liquid microextraction has been proposed for the extraction and preconcentration of some organophosphorus pesticides from different samples. In the present study, a high volume of an aqueous phase containing a polyol (sorbitol) is prepared and then a disperser solvent along with an extraction solvent is rapidly injected into it. Sorbitol showed the best results and it was more effective on the extraction recoveries of the analytes than inorganic salts such as sodium chloride, potassium chloride, and sodium sulfate. Under the optimum extraction conditions, the method showed low limits of detection and quantification within the ranges of 12–56 and 44–162 pg/mL, respectively. Enrichment factors and extraction recoveries were in the ranges of 2799–3033 and 84–92%, respectively. The method precision was evaluated at a concentration of 10 ng/mL of each analyte, and relative standard deviations were found to be less than 5.9% for intraday (n = 6) and less than 7.8% for interday (n = 4). Finally, some aqueous samples were successfully analyzed using the proposed method and four analytes (diazinon, dimethoate, chlorpyrifos, and phosalone) were determined, some of them at ng/mL level.  相似文献   

12.
A novel electrospun composite nanofiber‐based adsorbent (polyurethane/polystyrene‐silica) was fabricated, characterized, and used in the headspace solid‐phase microextraction of the acetylated derivatives of chlorophenols in water samples before gas chromatography with micro electron capture detection. The surface morphology, chemical composition, thermal stability, and structure of the fibers were investigated by scanning electron microscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis, and Brunauer–Emmett–Teller and Barrett–Joyner–Halenda techniques. The effect of the main parameters influencing the efficiency of the method including extraction temperature, salt concentration, and extraction time was investigated and the optimized conditions were obtained. The linear dynamic ranges were 0.1–800 ng/mL. The relative standard deviations (n = 3) and the limits of detection were 2.64–9.57% and 0.0234–0.830 ng/mL, respectively. The relative recoveries for real samples (river water and sewage of our university campus) were between 90.8 and 111%.  相似文献   

13.
We have developed a synergic microextraction procedure based on ionic liquid for the pre‐concentration and determination of glucocorticoids in water samples. Using nonionic surfactant Triton X‐100 (TX‐100) as synergic reagent, 1‐butyl‐3‐methylimidazolium hexa‐fluorophosphate accomplished extraction rapidly without heating in water bath. One key property of ionic liquids that highlights their potential is their wide liquid temperature range. The improved extraction was named as ionic liquid supported vortex‐assisted synergic microextraction. Compared with the traditional liquid–liquid extraction and cloud point extraction, ionic liquid supported vortex‐assisted synergic microextraction was accomplished in 8 min with considerably high recovery. The proposed method greatly improved the sensitivity of HPLC for the determination of glucocorticoids. The results obtained indicated a good linearity with the correlation coefficient of 0.997 over the range of 0.6–300 ng/mL and high sensitivity with LODs of 4.11, 9.19, and 7.50 ng/mL for hydrocortisone butyrate, beclomethasone dipropionate, and nandrolone phenylpropionate, respectively. The RSD of the method was 1.57–1.81% (n = 6) with enrichment factor of 99.85, and good recovery (≥97.24%). The method was successfully applied to the determination of glucocorticoids in mineral water, water of Dianchi lake, and tap water samples.  相似文献   

14.
A novel, low‐cost and effective in‐needle solid‐phase microextraction device was developed for the enrichment of trace polycyclic aromatic hydrocarbons in water samples. The in‐needle solid‐phase microextraction device could be easily assembled by inserting hydrofluoric acid‐etched wires, which were used as adsorbent, into a 22‐gauge needle tube within spring supporters. Compared with the commercial solid‐phase microextraction fiber, the developed device has higher efficiency for the extraction of polycyclic aromatic hydrocarbons with four to six rings from water samples using the optimized extraction conditions. With gas chromatography equipped with a flame ionization detector, the limits of detection for the polycyclic aromatic hydrocarbons with four to six rings ranged from 0.0020 to 0.0067 ng/mL. The relative standard deviations for one needle and needle‐to‐needle extractions were in the range of 5.2–9.9% (n = 5) and 3.4–12.3% (n = 5), respectively. The spiked recoveries of the polycyclic aromatic hydrocarbons in tap water samples ranged from 73.2 to 95.4%. This in‐needle solid‐phase microextraction device could be a good field sampler because of the low sample loss over a long storage time.  相似文献   

15.
A new analytical method for the simultaneous determination of trace levels of seven prohibited N‐nitrosamines (N‐nitrosodimethylamine, N‐nitrosoethylmethylamine, N‐nitrosopyrrolidine, N‐nitrosodiethylamine, N‐nitrosopiperidine, N‐nitrosomorpholine, and N‐nitrosodiethanolamine) in cosmetic products has been developed. The method is based on vortex‐assisted reversed‐phase dispersive liquid–liquid microextraction, which allows the extraction of highly polar compounds, followed by liquid chromatography with mass spectrometry. The variables involved in the extraction process were studied to obtain the highest enrichment factor. Under the selected conditions, 75 μL of water as extraction solvent was added to 5 mL of n‐hexane sample solution and assisted by vortex mixing during 30 s to form the cloudy solution. The method was successfully validated showing good linearity (0.5–50 ng/mL), enrichment factors up to 65 depending on the target compound, limits of detection values of 1.8–50 ng/g, and good repeatability (RSD < 9.8%). Finally, the proposed method was applied to different cosmetic samples. Quantitative relative recovery values (80–113%) were obtained, thus showing that matrix effects were negligible. The achieved analytical features of the proposed method, besides of its simplicity and affordability, make it useful to perform the quality control of cosmetic products to ensure the safety of consumers.  相似文献   

16.
A sensitive microextraction method based on a new poly(methacrylic acid‐ethylene glycol dimethacrylate‐N‐vinylcarbazole) monolithic capillary column, coupled with gas chromatography and electron capture detection, was established for the determination of three benzodiazepines (estazolam, alprazolam, and triazolam) in urine and beer samples. Owing to the abundant π electrons and polar surface of N‐vinylcarbazole, N‐vinylcarbazole‐incorporated monolith showed a higher extraction performance than neat poly(methacrylic acid‐ethylene glycol dimethacrylate) because of the enhanced π–π stacking interactions derived from the π‐electron‐rich benzene groups from N‐vinylcarbazole. The monolith exhibited a homogeneous and continuous structure, good permeability, and a long lifetime. Factors affecting the extraction such as solution pH, salt concentration, sample volume, desorption solvent, and desorption volume were investigated. Under the optimized conditions, limits of detection of 0.011–0.026 ng/mL were obtained. The one‐column and column‐to‐column precision values were ≤7.2 and ≤9.8%, respectively. The real samples were first diluted with deionized water and then treated by the monolith microextraction before gas chromatography analysis. The recoveries were 81.4–93.3 and 83.3–94.7% for the spiked samples, with relative standard deviations of 4.1–8.1 and 3.8–8.5%, respectively. This method provides an accurate, simple, and sensitive detection platform for drug analysis.  相似文献   

17.
The biomonitoring of hydroxy polycyclic aromatic hydrocarbons in urine, as a direct way to access multiple exposures to polycyclic aromatic hydrocarbons, has raised great concerns due to their increasing hazardous health effects on humans. Solid‐phase extraction is an effective and useful technique to preconcentrate trace analytes from biological samples. Here, we report a novel solid‐phase extraction method using a graphene oxide incorporated monolithic syringe for the determination of six hydroxy polycyclic aromatic hydrocarbons in urine coupled with liquid chromatography‐tandem mass spectrometry. The effect of graphene oxide amount, washing solvent, eluting solvent, and its volume on the extraction performance were investigated. The fabricated monoliths gave higher adsorption efficiency and capacity than the neat polymer monolith and commercial C18 sorbent. Under the optimum conditions, the developed method provided the detection limits (S/N = 3) of 0.02–0.1 ng/mL and the linear ranges of 0.1–1500 ng/mL for six analytes in urine sample. The recoveries at three spiked levels ranged from 77.5 to 97.1%. Besides, the intra column‐to‐column (n = 3) and inter batch‐to‐batch (n = 3) precisions were ≤ 9.8%. The developed method was successfully applied for the determination of hydroxy polycyclic aromatic hydrocarbons in urine samples of coke oven workers.  相似文献   

18.
In the present work, for the first time, an all‐in‐one solid‐phase microextraction technique was developed for the simultaneous and efficient extraction of analytes within a vast polarity range. A novel fiber assembly composed of two different steel components each coated with different coatings (polydimethylsiloxane and polyethylene glycol) in terms of polarity by sol–gel technology was employed for the extraction of model compounds of different polarity in a single run followed by gas chromatography with mass spectrometry. Effective parameters in the extraction step and gas chromatography with mass spectrometry analysis were optimized for all model compounds. The detection limits of the developed method for model compounds were below 0.2 ng/L. The repeatability and reproducibility of the proposed method, explained by relative standard deviation, varied between 7.22 and 9.15% and between 7.95 and 14.90 (n = 5), respectively. Results showed that, under random conditions, compared to separate extractions performed by two other differently end‐coated components that had not been assembled as the final dual fiber, as two individual fibers; simultaneous, efficient and relatively selective extraction of all model compounds was obtained in a single run by the proposed all‐in‐one technique. Finally, the optimized procedure was applied to extraction and determination of the model compounds in spiked water samples.  相似文献   

19.
To provide a reliable tool for investigating diffusion processes of the specific components of the human odor 3‐hydroxy‐3‐methylhexanoic acid and 3‐methyl‐3‐sulfanylhexan‐1‐ol through the snowpack, we developed and optimized an analytical method based on direct immersion solid‐phase microextraction followed by gas chromatography with mass spectrometry. Direct immersion solid‐phase microextraction was performed using polyacrylate fibers placed in aqueous solutions containing 3‐hydroxy‐3‐methylhexanoic acid and 3‐methyl‐3‐sulfanylhexan‐1‐ol. After optimization, absorption times of 120 min provided a good balance to shorten the analysis time and to obtain suitable amounts of extractable analytes. The extraction efficiency was improved by increasing the ionic strength of the solution. Although the absolute extraction efficiency ranged between 10 and 12% for 3‐hydroxy‐3‐methylhexanoic acid and 2–3% for 3‐methyl‐3‐sulfanylhexan‐1‐ol, this method was suitable for analyzing 3‐hydroxy‐3‐methylhexanoic acid and 3‐methyl‐3‐sulfanylhexan‐1‐ol concentrations of at least 0.04 and 0.20 ng/mL, respectively. The precision of the direct immersion solid‐phase microextraction method ranged between 8 and 16%. The variability within a batch of six fibers was 10–18%. The accuracy of the method provided values of 88–95 and 86–101% for 3‐hydroxy‐3‐methylhexanoic acid and 3‐methyl‐3‐sulfanylhexan‐1‐ol, respectively. The limit of detection (and quantification) was 0.01 ng/mL (0.04 ng/mL) for 3‐hydroxy‐3‐methylhexanoic acid and 0.06 ng/mL (0.20 ng/mL) for 3‐methyl‐3‐sulfanylhexan‐1‐ol. The signal versus concentration was linear for both compounds (r2 = 0.973–0.979). The stability of these two compounds showed that 3‐hydroxy‐3‐methylhexanoic acid was more stable in water than 3‐methyl‐3‐sulfanylhexan‐1‐ol. We applied the method to environmental samples in correspondence with an olfactory target buried previously.  相似文献   

20.
In this study, molecularly imprinted polymer fibers for solid‐phase microextraction have been prepared with a single bifunctional monomer, N,O‐bismethacryloyl ethanolamine using the so‐called “one monomer molecularly imprinted polymers” method, replacing the conventional combination of functional monomer and cross‐linker to form high fidelity binding sites. For comparison, imprinted fibers were prepared following the conventional approach based on ethylene glycol dimethacrylate as cross‐linker and methacrylic acid as monomer. The recognition performance of the new fibers was evaluated in the solid‐phase microextraction of parabens, and from this study it was concluded that they provided superior performance over conventionally formulated fibers. Ultimately, real‐world environmental testing on spiked solid samples was successful by the molecularly imprinted solid‐phase microextraction of samples, and the relative recoveries obtained at enrichment levels of 10 ng/g of parabens were within 78–109% for soil and 83–109% for sediments with a relative standard deviation <15% (n = 3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号