首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
The metrological principle of ‘differential technique in laser-induced fluorimetry’ analysis is discussed and recommended as a reference measurement procedure for determination of total uranium content in ores and similar matrices. The estimated relative expanded uncertainty values obtained for uranium content in standard IAEA samples are, S 1, 0.04 g/kg, S 2, 0.06 g/kg, S 3, 0.04 g/kg, and for S 4, 0.10 g/kg, respectively. These low uncertainty values obtained for uranium show high metrological quality of differential technique. This reference measurement procedure guarantees the quality of an analytical result (accuracy, high precision, reliability, comparability, and traceability). Laser-induced fluorimetry will be useful for the analysis of uranium in ores, certification of reference materials, borehole core assay, and other diverse applications in nuclear fuel cycle. Differential technique in spectrophotometry/laser fluorimetry has inherent high metrological quality. In principle, laser-induced fluorimetry is an ideal technique for the very accurate determination of uranium by the use of appropriate fluorescence-enhancing reagents and methodology depending upon the concentration of uranium and sample matrices.  相似文献   

2.
The main objective of this work is the accurate measurement of uranium in the potable water sources of Muktsar district of Punjab, India. In the present work, a laser fluorimetry technique was used for the analysis of uranium. Inductively coupled plasma mass spectrometry (ICPMS) technique was also applied to verify and compare the uranium content analyzed using laser technique. About 16 samples from waterworks, bore wells, and hand pumps that supply the drinking water to local population were collected for this purpose. An indigenous laser fluorimeter supplied by RRCAT, Indore was employed for the analysis. Uranium concentrations obtained were in the range from 0 to 10???g?L?1 in ten samples, 11?C30???g?L?1 in three samples, and more than 100???g?L?1 in three samples namely Channu ground water, Warning Khera pump, and Killanwale village hand pump. The USEPA guideline value for uranium in safe drinking water is 30???g?L?1. Also, a data comparison with similar studies carried out in other countries is presented.  相似文献   

3.
A method for estimation of uranium in seawater by using steady state laser flourimetry is described. Uranium present in seawater, in concentration of approximately 3 ng ml−1 was estimated without prior separation of matrix. Quenching effect of major ions (Cl, Na+, SO4, Mg+, Ca+, K+, HCO3, Br) present in seawater on fluorescence intensity of uranium was studied. The concentration of phosphoric acid required for maximum enhancement of fluorescence intensity was optimized and was found to be 5%. Similarly the volume of concentrated nitric acid required to eliminate the quenching effect of chloride and bromide completely from 5 ml of seawater were optimized and was found to be 3 ml. A simple equation was derived using steady state fluorescence correction method and was used for calculation of uranium concentration in seawater samples. The method has a precesion of 1% (1 s, n = 3). The values obtained from laser fluorimetry were validated by analyzing the same samples by linear sweep adsorptive stripping voltametry (LSASV) of the uranium-chloranilic acid (2,5-dichloro-3,6-dihydroxy-1,4-benzoquinone) complex. Both the values are well in agreement.  相似文献   

4.
Gomez V  Ferreres L  Pocurull E  Borrull F 《Talanta》2011,84(3):859-866
Solid-phase extraction (SPE) combined with liquid chromatography electrospray mass spectrometry (LC-(ESI)MS) was used to determine 16 non-ionic and anionic surfactants in different environmental water samples at ng L−1 levels. The proposed method is sensitive and simple and has good linear range and detection limits (less than 50 ng L−1) for most compound classes.The effect of ion suppression was studied in aqueous matrices from several treatment plants—including urban and industrial wastewater treatment plants (WWTPs), drinking-water treatment plants (DWTPs) and seawater desalination plants (SWDPs)—and it was considered when quantifying our samples. In addition, conventional treatments and tertiary treatments that use advanced membrane technologies, such as ultrafiltration (UF) and reverse osmosis (RO) were evaluated in order to determine their efficiency in eliminating these compounds.The concentrations of non-ionic surfactants in the raw waters studied ranged from 0.2 to 100 μg L−1. In effluents, the concentrations ranged from 0.1 to 5 μg L−1, which reflects consistent elimination. Anionic surfactants were present in all waters studied at higher levels. Levels up to 3900 μg L−1 of linear alkylbenzene sulfonates (LASs) and 32,000 μg L−1 of alkyl ethoxysulfates (AESs) were detected in urban WWTP influents, while levels up to 25 μg L−1 of LASs and 114 μg L−1 of AESs were found in drinking-water and desalination treatment plants.The results indicate that conventional processes alone are not sufficient to completely remove the studied surfactants from waste streams. Tertiary treatments that use advanced membrane technologies such as UF and RO can further reduce the amount of target compounds in the effluent water.  相似文献   

5.
The paper describes a research of possible application of UTEVA and TRU resins and anion exchanger AMBERLITE CG-400 in nitrate form for the isolation of uranium and thorium from natural samples. The results of determination of distribution coefficient have shown that uranium and thorium bind on TRU and UTEVA resins from the solutions of nitric and hydrochloric acids, and binding strength increases proportionally to increase the concentration of acids. Uranium and thorium bind rather strongly to TRU resin from the nitric acid in concentration ranging from 0.5 to 5 mol L−1, while large quantities of other ions present in the sample do not influence on the binding strength. Due to the difference in binding strength in HCl and HNO3 respectively, uranium and thorium can be easily separated from each other on the columns filled with TRU resin. Furthermore, thorium binds to anion exchanger in nitrate form from alcohol solutions of nitric acid very strongly, while uranium does not, so they can be easily separated. Based on these results, we have created the procedures of preconcentration and separation of uranium and thorium from the soil, drinking water and seawater samples by using TRU and UTEVA resins and strong base anion exchangers in nitrate form. In one of the procedures, uranium and thorium bind directly from the samples of drinking water and seawater on the column filled with TRU resin from 0.5 mol L−1 HNO3 in a water sample. After binding, thorium is separated from uranium with 0.5 mol L−1 HCl, and uranium is eluted with deionised water. By applying the described procedure, it is possible to achieve the concentration factor of over 1000 for the column filled with 1 g of resin and splashed with 2 L of the sample. Spectrophotometric determination with Arsenazo III, with this concentration factor results in detection limits below 1 μg L−1 for uranium and thorium. In the second procedure, uranium and thorium are isolated from the soil samples with TRU resin, while they are separated from each other on the column filled with anion exchanger in alcohol solutions. Anion exchanger combined with alcohol solutions enables isolation of thorium from soil samples and its separation from a wide range of elements, as well as spectrophotometric determination, ICP-MS determination, and other determination techniques.  相似文献   

6.
Avivar J  Ferrer L  Casas M  Cerdà V 《Talanta》2011,84(5):1221-1227
The hyphenation of lab-on-valve (LOV) and multisyringe flow analysis (MSFIA), coupled to a long path length liquid waveguide capillary cell (LWCC), allows the spectrophotometric determination of uranium in different types of environmental sample matrices, without any manual pre-treatment, and achieving high selectivity and sensitivity levels. On-line separation and preconcentration of uranium is carried out by means of UTEVA resin. The potential of the LOV-MSFIA makes possible the fully automation of the system by the in-line regeneration of the column. After elution, uranium(VI) is spectrophotometrically detected after reaction with arsenazo-III. The determination of levels of uranium present in environmental samples is required in order to establish an environmental control. Thus, we propose a rapid, cheap and fully automated method to determine uranium(VI) in environmental samples. The limit of detection reached is 1.9 ηg of uranium and depending on the preconcentrated volume; it results in ppt levels (10.3 ηg L−1). Different water sample matrices (seawater, well water, freshwater, tap water and mineral water) and a phosphogypsum sample (with natural uranium content) were satisfactorily analyzed.  相似文献   

7.
Commercially available Diphonix® resin (TrisKem International) was evaluated as a receiving phase for use with the diffusive gradients in thin-films (DGT) passive sampler for measuring uranium. This resin has a high partition coefficient for actinides and is used in the nuclear industry. Other resins used as receiving phases with DGT for measuring uranium have been prone to saturation and significant chemical interferences. The performance of the device was evaluated in the laboratory and in field trials. In laboratory experiments uptake of uranium (all 100% efficiency) by the resin was unaffected by varying pH (4–9), ionic strength (0.01–1.00 M, as NaNO3) and varying aqueous concentrations of Ca2+ (100–500 mg L−1) and HCO3 (100–500 mg L−1). Due to the high partition coefficient of Diphonex®, several elution techniques for uranium were evaluated. The optimal eluent mixture was 1 M NaOH/1 M H2O2, eluting 90% of the uranium from the resin. Uptake of uranium was linear (R2 = 0.99) over time (5 days) in laboratory experiments using artificial freshwater showing no saturation effects of the resin. In field deployments (River Lambourn, UK) the devices quantitatively accumulated uranium for up to 7 days. In both studies uptake of uranium matched that theoretically predicted for the DGT. Similar experiments in seawater did not follow the DGT theoretical uptake and the Diphonix® appeared to be capacity limited and also affected by matrix interferences. Isotopes of uranium (U235/U238) were measured in both environments with a precision and accuracy of 1.6–2.2% and 1.2–1.4%, respectively. This initial study shows the potential of using Diphonix®-DGT for monitoring of uranium in the aquatic environment.  相似文献   

8.
A new synthesized modified mesoporous silica (MCM-41) using 5-nitro-2-furaldehyde (fural) was applied as an effective sorbent for the solid phase extraction of uranium(VI) and thorium(IV) ions from aqueous solution for the measurement by inductively coupled plasma optical emission spectrometry (ICP OES). The influences of some analytical parameters on the quantitative recoveries of the analyte ions were investigated in batch method. Under optimal conditions, the analyte ions were sorbed by the sorbent at pH 5.5 and then eluted with 1.0 mL of 1.0 mol L−1 HNO3. The preconcentration factor was 100 for a 100 mL sample volume. The limits of detection (LOD) obtained for uranium(VI) and thorium(IV) were 0.3 μg L−1. The maximum sorption capacity of the modified MCM-41 was found to be 47 and 49 mg g−1 for uranium(VI) and thorium(IV), respectively. The sorbent exhibited good stability, reusability, high adsorption capacity and fast rate of equilibrium for sorption/desorption of uranium and thorium ions. The applicability of the synthesized sorbent was examined using CRM and real water samples.  相似文献   

9.
A novel procedure for the extraction of uranium has been described. UO2 2+ forms a 1:3 anionic complex with 2,3-dihydroxynaphthalene in the pH range, 4–12. This anionic complex is best extracted into ethyl acetate at pH 11–12 under the influence of a counter cation, cetyltrimethylammonium bromide. This extraction technique has been extended to the separation of uranium from silicate rock matrices for its determination by fluorimetry. Except Co, Cr, and Fe, most elements present in silicate rocks do not interfere. While the interferences of Co and Cr are suppressed by the addition of EDTA, iron is removed by prior extraction at pH 4–5 as its neutral complex with 2,3-dihydroxynaphthalene. The results compare favourably with those obtained from the conventional technique, i.e., extraction of uranium in ethyl acetate from NHO3 medium under the influence of Al(NO3)3 .9H2O as salting out agent. The extraction system under study is capable of separating even ultra-trace amounts of uranium quantitatively from complex matrices of rock samples. Besides, the method is simple, rapid, cost effective and precludes the use of reagents like nitric acid and aluminum nitrate (salting out agent) required in bulk quantities in the conventional system.  相似文献   

10.
The highly selective, fast and effective sample pretreatment technique molecularly imprinted solid-phase extraction (MISPE) can overcome the low sensitivity of the highly efficient capillary electrophoresis-UV method (CE-UV). In this work, narrowly dispersible bisphenol A (BPA)-imprinted polymeric microspheres with a high capacity factor of k′ = 6.8 and an imprinted factor of I = 6.53 were investigated as selective solid-phase extraction (SPE) sorbents for use in extraction of BPA from different sample matrices (tap water, wastewater, Yangtze River water, soil from the Yangtze River, shrimp and human urine). Washing and eluting protocols of MISPE were optimized. Under optimal conditions, recoveries of MISPE were investigated. Recoveries were basically constant and the relative standard deviation (RSD) was lower than 5.8% when loading volumes changed from 1 to 50 mL. Recoveries ranged from 71.20% to 86.23% for different sample matrices. Compared with C18 SPE, MISPE had higher selectivity and recovery for BPA. BPA was determined with good accuracy and precision in different complex samples using CE-UV coupled with MISPE. Spiked recoveries ranged from 95.20% to 105.40%, and the RSD was less than 7.2%. Because a large loading volume was achieved, the enrichment efficiency of pretreatment and the sensitivity of this method were improved. The limits of detection of this MISPE-CE-UV method for BPA in tap water, wastewater, Yangtze River water, soil from the Yangtze River, shrimp and human urine were 3.0 μg L− 1, 5.4 μg L− 1, 6.9 μg L− 1, 2.1 μg L− 1, 1.8 μg L− 1 and 84 μg L− 1, respectively.  相似文献   

11.
A laser induced breakdown spectrometry hyphenated with on-line continuous flow hydride generation sample introduction system, HG-LIBS, has been used for the determination of arsenic, antimony, lead and germanium in aqueous environments. Optimum chemical and instrumental parameters governing chemical hydride generation, laser plasma formation and detection were investigated for each element under argon and nitrogen atmosphere. Arsenic, antimony and germanium have presented strong enhancement in signal strength under argon atmosphere while lead has shown no sensitivity to ambient gas type. Detection limits of 1.1 mg L−1, 1.0 mg L−1, 1.3 mg L−1 and 0.2 mg L−1 were obtained for As, Sb, Pb and Ge, respectively. Up to 77 times enhancement in detection limit of Pb were obtained, compared to the result obtained from the direct analysis of liquids by LIBS. Applicability of the technique to real water samples was tested through spiking experiments and recoveries higher than 80% were obtained. Results demonstrate that, HG-LIBS approach is suitable for quantitative analysis of toxic elements and sufficiently fast for real time continuous monitoring in aqueous environments.  相似文献   

12.
Potentiometric stripping analysis (PSA) was investigated to assay simultaneously cadmium, lead and thallium present as contaminants in highly saline solutions used in hemodialysis. The saline matrices were sodium, potassium, magnesium and calcium chlorides, sodium acetate, sodium bicarbonate and glucose, which constitute concentrates for hemodialysis. A 1000 μg mL−1 Hg(II) solution was used to prepare the mercury film electrode (MFE) and to carry out the stripping step. After a 30 s accumulation interval the analytes were simultaneously detected in the saline matrices without using masking agents. Determination limits of 80 ng L−1 for cadmium and thallium, and 50 ng L−1 for lead were calculated and a R.S.D. ranging from 0.5 to 2.2% (n = 3) was obtained measuring the analytes directly in commercial hemodialysis saline solutions. Recoveries from spiked samples ranging from 94.6 to 102.0% were obtained. The investigated metals were found in concentrations ranging from 2.7 to 5.7 μg L−1 for cadmium, 27.7 to 75.8 μ L−1 for lead and 9.6 to 18.7 μg L−1 for thallium in commercial hemodialysis solutions. The PSA method showed to be adequate to the quality control of saline concentrates for hemodialysis.  相似文献   

13.
This study examines the application of solid-phase microextraction coupled with high performance liquid chromatography combined with post-column photochemically induced fluorimetry derivatization and fluorescence detection (SPME-HPLC-PIF-FD) for the determination of four phenylurea herbicides (monolinuron, diuron, linuron and neburon) and propanil in groundwater. Direct immersion (DI) SPME was applied using a 60 μm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber for the extraction of the pesticides from groundwater samples. An AQUASIL C18 column (150 mm × 4.6 mm i.d., 5 μm) was used for separation and determination in HPLC. The method was evaluated with respect to the limits of detection (LODs) and the limits of quantification (LOQs) according to IUPAC. The limits of detection varied between 0.019 μg L−1 and 0.034 μg L−1. Limits of quantification ranged between 0.051 μg L−1 and 0.088 μg L−1. These values meet the recommended limits for individual pesticides in groundwater (0.1 μg L−1) established by the EU. Recoveries ranged between 86% and 105% and relative standard deviation values between 2% and 8%.  相似文献   

14.
A simple and effective method is presented for the separation and preconcentration of thorium(IV) and uranium(VI) by solid phase extraction on Duolite XAD761 adsorption resin. Thorium(IV) and uranium(VI) 9-phenyl-3-fluorone chelates are formed and adsorbed onto the Duolite XAD761. Thorium(IV) and uranium(VI) are quantitatively eluted with 2 mol L−1 HCl and determined by inductively coupled plasma-mass spectrometry (ICP-MS). The influences of analytical parameters including pH, amount of reagents, amount of Duolite XAD761 and sample volume, etc. were investigated on the recovery of analyte ions. The interference of a large number of anions and cations has been studied and the optimized conditions developed have been utilized for the trace determination of uranium and thorium. A preconcentration factor of 30 for uranium and thorium was achieved. The relative standard deviation (N = 10) was 2.3% for uranium and 4.5% for thorium ions for 10 replicate determinations in the solution containing 0.5 μg of uranium and thorium. The three sigma detection limits (N = 15) for thorium(IV) and uranium(VI) ions were found to be 4.5 and 6.3 ng L−1, respectively. The developed solid phase extraction method was successively utilized for the determination of traces thorium(IV) and uranium(VI) in environmental samples by ICP-MS.  相似文献   

15.
This is the first study presenting a multi-residue method allowing for comprehensive analysis of several chiral pharmacologically active compounds (cPACs) including beta-blockers, antidepressants and amphetamines in wastewater and digested sludge at the enantiomeric level. Analysis of both the liquid and solid matrices within wastewater treatment is crucial to being able to carry out mass balance within these systems. The method developed comprises filtration, microwave assisted extraction and solid phase extraction followed by chiral liquid chromatography coupled with tandem mass spectrometry to analyse the enantiomers of 18 compounds within all three matrices. The method was successfully validated for 10 compounds within all three matrices (amphetamine, methamphetamine, MDMA, MDA, venlafaxine, desmethylvenlafaxine, citalopram, metoprolol, propranolol and sotalol), 7 compounds validated for the liquid matrices only (mirtazapine, salbutamol, fluoxetine, desmethylcitalopram, atenolol, ephedrine and pseudoephedrine) and 1 compound (alprenolol) passing the criteria for solid samples only. The method was then applied to wastewater samples; cPACs were found at concentration ranges in liquid matrices of: 1.7 ng L−1 (metoprolol) – 1321 ng L−1 (tramadol) in influent, <LOD (desmethylcitalopram and metoprolol) – 506 ng L−1 in effluent, and in solid matrix digested sludge: 0.4 ng g−1 (metoprolol) – 275 ng g−1 (citalopram). Enantiomeric profiling revealed that studied compounds were present in analysed samples in non-racemic composition. Furthermore, enantiomeric composition of studied analytes differed in liquid and solid matrices. This demonstrates that not analysing the solid fraction of wastewater may lead to over-estimation of the removal rates of cPACs as well as possible misrepresentation of the enantiomeric fraction of the compounds as they leave the wastewater treatment plant. Consequently risks from cPACs entering the environment might be higher than anticipated.  相似文献   

16.
In this work the development and validation of a new procedure for the simultaneous determination of 9 nitro and polycyclic musk compounds: musk ambrette (MA), musk ketone (MK), musk mosken (MM), celestolide (ADBI), phantolide (AHMI), tonalide (AHTN), traseolide (ATII), cashmeran (DPMI) and galaxolide (HHCB) in environmental water samples (estuarine and wastewater) using microextraction by packed sorbent (MEPS) followed by large volume injection-gas chromatography–mass spectrometry (LVI-GC–MS) was carried out. Apart from the optimization of the different variables affecting MEPS (i.e., nature of the sorbent, nature of the solvent elution, sample load, and elution/injection volume) extraction recovery was also evaluated, not only for water samples but also for environmental water matrices such as estuarine and waste water. The use of two deuterated analogs ([2H3]-AHTN and [2H15]-MX) was successfully evaluated in order to correct matrix effect in complex environmental matrices such as influent samples from wastewater treatment plants. Method detection limits (MDLs) ranged from 5 to 25 ng L−1, 7 to 39 ng L−1 and 8 to 84 ng L−1 for influent, effluent and estuarine samples, respectively. Apparent recoveries were higher than 75% for all target compounds in all the matrices studied (estuarine water and wastewater) and the precision of the method, calculated as relative standard deviation (RSD), was below 13.2% at 200 ng L−1 concentration level and below 14.9% at low level (20 ng L−1 for all the target analytes, except for AHTN which was set at 40 ng L−1 and HHCB at 90 ng L−1, due to the higher MDL values presented by those target compounds). Finally, this MEPS procedure was applied to the determination of the target analytes in water samples, including estuarine and wastewater, from two estuaries, Urdaibai (Spain) and Adour (France) and an established stir-bar sorptive extraction-liquid desorption/large volume injection-gas chromatography–mass spectrometry (SBSE-LD/LVI-GC–MS) method was performed in parallel for comparison. Results were in good agreement for all the analytes determined, except for DPMI.  相似文献   

17.
Direct determination of uranium in the concentration range of 8 μg L−1 to mg L−1 in water samples originating from different geochemical environments has been done using Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES). Uranium detection with 2–3% RSD (relative standard deviation) has been achieved in water samples by optimizing the plasma power, argon and sheath gas flow. These parameters were optimized for three different emission lines of uranium at 385.958, 409.014 and 424.167 nm. Interference arising due to the variation in concentration of bicarbonate, sodium chloride, calcium chloride, Fe and dissolved organic carbon (DOC) on the determination of uranium in water samples was also cheeked as these are the elements which vary as per the prevailing geochemical environment in groundwater samples. The concentration of NaHCO3, CaCl2 and NaCl in water was varied in the range 0.5–2.0%; whereas Fe ranged between 1 and 10 μg mL−1 and DOC between 0.1–1%. No marked interference in quantitative determination of uranium was observed due to elevated level of NaHCO3, CaCl2 and NaCl and Fe and DOC in groundwater samples. Concentration of uranium was also determined by other techniques like adsorptive striping voltametry (AdSv); laser fluorimetry and alpha spectrometry. Results indicate distinct advantage for uranium determination by ICP-OES compare to other techniques.  相似文献   

18.
An alternative analysis technique for the quantitation of 15 poly- and perfluoroalkyl substances (PFASs) in water matrices is reported. Analysis time between each sample was reduced to less than 20 s, all target molecules being analyzed in a single run with the use of laser diode thermal desorption atmospheric pressure chemical ionization (LDTD/APCI) coupled with high resolution accurate mass (HRMS) orbitrap mass spectrometry. LDTD optimal settings were investigated using either one-factor-at-a-time or experimental design methodologies, while orbitrap parameters were optimized simultaneously by means of a Box–Behnken design. Following selection of an adequate sample concentration and purification procedure based on solid-phase extraction and graphite clean-up, the method was validated in an influent wastewater matrix. Environmentally significant limits of detection were reported (0.3–4 ng L−1 in wastewater and 0.03–0.2 ng L−1 in surface water) and out of the 15 target analytes, 11 showed excellent accuracies (±20% of the target values) and recovery rates (75–125%). The method was successfully applied to a selection of environmental samples, including wastewater samples in 7 locations across Canada, as well as surface and tap water samples from the Montreal region, providing insights into the degree of PFAS contamination in this area.  相似文献   

19.
A newly established uranium processing facility has been commissioned at BARC, Trombay. Monitoring of occupational workers is essential to assess intake of uranium in this facility. A group of 21 workers was selected for bioassay monitoring to assess the existing urinary excretion levels of uranium before the commencement of actual work. Bioassay samples collected from these workers were analyzed by ion-exchange technique followed by laser fluorimetry. Standard addition method was followed for estimation of uranium concentration in the samples. The minimum detectable activity by this technique is about 0.2 ng. The range of uranium observed in these samples varies from 19 to 132 ng/L. Few of these samples were also analyzed by fission track analysis technique and the results were found to be comparable to those obtained by laser fluorimetry. The urinary excretion rate observed for the individual can be regarded as a ‘personal baseline’ and will be treated as the existing level of uranium in urine for these workers at the facility.  相似文献   

20.
A new functionalized mesoporous silica (MCM-41) using salicylaldehyde was utilized for the separation, preconcentration and determination of uranium in natural water by inductively coupled plasma atomic emission spectrometry (ICP-AES).Experimental conditions for effective adsorption of trace levels of U(VI) were optimized. The preconcentration factor was 100 (1.0 mL of elution for a 100 mL sample volume). The analytical curve was linear in the range 2-1000 μg L−1 and the detection limit was 0.5 ng mL−1. The relative standard deviation (R.S.D.) under optimum conditions was 2.5% (n = 10). Common coexisting ions did not interfere with the separation and determination of uranium at pH 5. The sorbent exhibited excellent stability and its sorption capacity under optimum conditions has been found to be 10 mg of uranium per gram of sorbent. The method was applied for the recovery and determination of uranium in different water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号