首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We developed an ultra-sensitive method of amino acid analysis (AAA) for the absolute quantification of less than 100 ng of proteins, in solution or on polyvinylidene difluoride (PVDF) membranes using an oxygen-free chamber for protein hydrolysis. We used a pre-label method with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate for fluorescence detection, ion-pair chromatography with a reversed-phase column, and an ultra-high-pressure high-performance liquid chromatography. We optimized both handling- and instrument-dependent factors for accurate quantification and showed that the least amount of proteins to quantify was determined by handling accuracy rather than instrumental limit for quantification which was 0.6 fmol/amino acid. As a new evaluation method for the handling accuracy, we adopted the protein identification by the obtained amino acid compositions by AAA and the Swiss-Prot database search without the restriction of species. As a result, the least amount of starting material for AAA was 16 ng (0.24 pmol) for a solution of bovine serum albumin (BSA), 33 ng (0.50 pmol) for BSA on a PVDF membrane, and 44 ng (0.15 pmol) for thyroglobulin on a PVDF membrane. These results demonstrate that the ultra-sensitive AAA developed in this study is feasible for absolute quantification of biological significant protein.
Figure
Specification of ultra-sensitive amino acid analysis  相似文献   

2.
Herein, we describe an accurate method for protein quantification based on conventional acid hydrolysis and an isotope dilution-ultra performance liquid chromatography–tandem mass spectrometry method. The analyte protein, recombinant human erythropoietin (rhEPO), was effectively hydrolyzed by incubation with 8 mol/L hydrochloric acid at 130 °C for 48 h, in which at least 1 μmol/kg of rhEPO was treated to avoid possible degradation of released amino acids during hydrolysis. Prior to hydrolysis, sample solution was subjected to ultrafiltration to eliminate potential interfering substances. In a reversed-phase column, the analytes (phenylalanine, proline, and valine) were separated within 3 min using gradient elution comprising 20 % (v/v) acetonitrile and 10 mmol/L ammonium acetate, both containing 0.3 % (v/v) trifluoroacetic acid. The optimized hydrolysis and analytical conditions in our study were strictly validated in terms of accuracy and precision, and were suitable for the accurate quantification of rhEPO. Certified rhEPO was analyzed using a conventional biochemical assay kit as an additional working calibrant for the quantification of EPO and improved the accuracy. The optimized protocol is suitable for the accurate quantification of rhEPO and satisfactorily serves as a reference analytical procedure for the certification of rhEPO and similar proteins.
Figure
The concept of protein quantification by amino acid analysis via acid hydrolysis using isotopedilution LC-MS  相似文献   

3.
The characterization of the organic components in a complex, multilayered paint structure is fundamental for studying painting techniques and for authentication and restoration purposes. Proteinaceous materials, such as animal glue, are of particular importance since they are widely used as binders, adhesives and for gilding. Even though proteins are usually detected by chromatographic and proteomic techniques, immunological methods represent an alternative powerful approach to protein analysis thanks to the high specificity of antigen–antibody reactions. Our previous studies demonstrated that ovalbumin and casein could be localized in paint cross-sections with high sensitivity and good spatial resolution (i.e. within the single painting layers) by using chemiluminescent (CL) immunochemical microscope imaging. In the present research work, we describe for the first time the immunolocalization of collagen (the main protein of animal glue) in paint cross-sections by CL imaging microscopy. Two different analytical protocols have been developed, allowing either the detection of collagen or the simultaneous detection of collagen and ovalbumin in the same paint sample. The assays were used to detect collagen and ovalbumin in cross-sections from model samples and historical paintings (a wall painting dated to 1773–1774 and a painted wood panel of the Renaissance period) in order to achieve information on paint techniques and past restoration interventions.
Figure
Left Reflected light image of a cross-section of a sample taken from a Renaissance painted wood panel. Right Localization of the proteins collagen (from animal glue) and ovalbumin in a painting cross-section assessed by multiplexed chemiluminescence immunochemical imaging (the chemiluminescent signals corresponding to collagen and ovalbumin are displayed in shades of blue and red, respectively)  相似文献   

4.
A functionalized gold-nanoparticle bio-barcode assay, based on real-time immuno-PCR (IPCR), was designed for the determination of 3,4,3',4'-tetrachlorobiphenyl (PCB77). 15 nm gold nanoparticles were synthesized, and modified with thiol-capped DNA and goat anti-rabbit IgG. The nanoparticle probes were used to replace antibody–DNA conjugate in the IPCR, and were fixed on the PCR tube wall via the immune reaction. Real-time PCR was performed to quantify the DNA signal directly. Under optimized conditions, the new method was used to detect PCB77 with a linearity range from 5 pg L?1 to 10 ng L?1, and the limit of detection (LOD) was 1.72 pg L?1. Real samples of Larimichthys polyactis, collected from the East China Sea, were analyzed. Recovery was from 82 % to 112 %, and the coefficient of variation (CV) was acceptable. The results were compared with GC–ECD, revealing that the method would be acceptable for providing rapid, semi-quantitative, and reliable test results for making environmental decisions.
FIGURE
?  相似文献   

5.
In this work, desorption of nonvolatile analytes induced by friction was studied. The nonvolatile compounds deposited on the perfluoroalkoxy substrate were gently touched by an ultrasonic cutter oscillating with a frequency of 40 kHz. The desorbed molecules were ionized by a dielectric barrier discharge (DBD) ion source. Efficient desorption of samples such as drugs, pharmaceuticals, amino acids, and explosives was observed. The limits of detection for these compounds were about 1 ng. Many compounds were detected in their protonated forms without undergoing significant fragmentation. When the DBD was off, no ions for the neutral samples could be detected, meaning that only desorption along with little ionization took place by the present technique.
Figure
?  相似文献   

6.
A highly sensitive method was developed for the simultaneous determination of ten sulfonamides in pork and chicken samples by monolith-based stir bar sorptive extraction (SBSE) coupled to high-performance liquid chromatography tandem mass spectrometry. The samples were freeze-dried and extracted by acetonitrile, then enriched and further extracted by SBSE which was based on poly(vinylphthalimide-co-N,N-methylenebisacrylamide) monolith (SBSE-VPMB) as coating. To achieve optimum extraction performance of SBSE for sulfonamides, several parameters, including pH value and ionic strength in the sample matrix and extraction and desorption time, were investigated in detail. Under the optimal conditions, the limits of detection (S/N?=?3) for target sulfonamides were 1.2–6.1 ng/kg in pork and 2.0–14.6 ng/kg in chicken, respectively. Real samples spiked at the concentration of 0.5 and 5.0 μg/kg showed recoveries above 55 % and relative standard deviations below 12 %. At the same time, the extraction performances of target sulfonamides on SBSE-VPMB were compared with other SBSE based on porous monolith and commercial SBSE.
Figure
?  相似文献   

7.
We report on a fast, simple and accurate method for the determination of proline in urine samples by employing a nanostructured film of conducting polypyrrole for electrochemically controlled solid-phase microextraction, and ion mobility spectrometry (IMS) for detection. This method has the advantages of simple sample preparation and a sensitivity of IMS to proline that is higher than that for other amino acids. The calibration curve is linear in the range of 0.5–60 μg L?1 (4–521 nmol L?1), and the detection limit is 0.2 μg L?1. The electrochemical potentials for uptake and release were optimized. The method was successfully applied to the clean-up and quantitation of trace amounts of proline in urine samples.
Figure
Proline determination by electrochemically controlled solid phase microextraction coupled to ion mobility spectrometry  相似文献   

8.
Metabolomics has become an important tool in clinical research and the diagnosis of human disease. Intratracheal instillation of trans-trans 2,4-decadienal (tt-DDE), a major component in cooking oil fumes, has been demonstrated to cause lung lesions in mice at 8 weeks after treatment. The objective of this study was to identify any changes in metabolite profiles associated with the development of tt-DDE-induced lung lesions. Using a metabolomics strategy involving a liquid chromatography–mass spectrometry-based approach in conjunction with principal component analysis and confirmation by liquid chromatography triple quadrupole tandem mass spectrometry, we have demonstrated that the amino acid profiles of the urine and serum of tt-DDE-treated mice are changed. Ten amino acids were significantly reduced in serum of tt-DDE-treated mice at 8 weeks after treatment. Our results suggest that amino acid profiles may be useful as an early indicator of the presence of tt-DDE-induced lung lesions.
Figure
?  相似文献   

9.
A novel ionic liquid-modified organic-polymer monolithic capillary column was prepared and used for in-tube solid-phase microextraction (SPME) of acidic food additives. The primary amino group of 1-aminopropyl-3-methylimidazolium chloride was reacted with the epoxide group of glycidyl methacrylate. The as-prepared new monomer was then copolymerized in situ with acrylamide and N,N’-methylenebisacrylamide in the presence of polyethylene glycol (PEG)-8000 and PEG-10,000 as porogens. The extraction performance of the developed monolithic sorbent was evaluated for benzoic acid, 3-hydroxybenzoic acid, cinnamic acid, 2,4-dichlorophenoxyacetic acid, and 3-(trifluoromethyl)-cinnamic acid. Such a sorbent, bearing hydrophobic and anion-exchange groups, had high extraction efficiency towards the test compounds. The adsorption capacities for the analytes dissolved in water ranged from 0.18 to 1.74 μg cm?1. Good linear calibration curves (R 2?>?0.99) were obtained, and the limits of detection (S/N?=?3) for the analytes were found to be in the range 1.2–13.5 ng mL?1. The recoveries of five acidic food additives spiked in Coca-Cola beverage samples ranged from 85.4 % to 98.3 %, with RSD less than 6.9 %. The excellent applicability of the ionic liquid (IL)-modified monolithic column was further tested by the determination of benzoic acid content in Sprite samples, further illustrating its good potential for analyzing food additives in complex samples.
Graphical abstract
?  相似文献   

10.
We demonstrate that base mismatches of caspase-3 DNA sequences can be detected by surface plasmon resonance (SPR) following signal amplification by polymerase from Thermus aquaticus (Taq). The concentration of magnesium ions and the respective dNTPs for polymerase binding to the oligonucleotides on the sensing surface were optimized. Taq polymerase binds to double-stranded DNA that is self-assembled on the gold surface of the biosensor to induce an SPR signal. Experiments are presented on the effect of Mg(II) and dNTP concentrations on the activity of the polymerase on the sensing surface. The detection limits are 50 pM, 0.1 nM, 0.7 nM, 7 nM, and 20 nM for correctly matched, single-base mismatched, two-base mismatched, three-base mismatched and four-base mismatched DNA of caspase-3, respectively. This is attributed to the optimized experimental conditions, with samples containing 2 μM of Mg(II) and 0.3 mM of dNTP.
Figure
The process of detecting mismatched caspase-3 DNA oligonucleotides with SPR biosensor  相似文献   

11.
An isothermal cross-priming amplification (CPA) assay for Agrobacterium tumefaciens nopaline synthase terminator (T-Nos) was established and investigated in this work. A set of six specific primers, recognizing eight distinct regions on the T-Nos sequence, was designed. The CPA assay was performed at a constant temperature, 63 °C, and detected by real-time fluorescence. The results indicated that real-time fluorescent CPA had high specificity, and the limit of detection was 1.06?×?103 copies of rice genomic DNA, which could be detected in 40 min. Comparison of real-time fluorescent CPA and conventional polymerase chain reaction (PCR) was also performed. Results revealed that real-time fluorescent CPA had a comparable sensitivity to conventional real-time PCR and had taken a shorter time. In addition, different contents of genetically modified (GM)-contaminated rice seed powder samples were detected for practical application. The result showed real-time fluorescent CPA could detect 0.5 % GM-contaminated samples at least, and the whole reaction could be finished in 35 min. Real-time fluorescent CPA is sensitive enough to monitor labeling systems and provides an attractive method for the detection of GMO.
Figure
?  相似文献   

12.
The nicotine metabolites, cotinine and trans-3′-hydroxycotinine (3HC) are considered as superior biomarkers for identifying tobacco exposure. More importantly, the ratio of 3HC to cotinine is a good indicator to phenotype individuals for cytochrome P450 2A6 activity and to individualize pharmacotherapy for tobacco addiction. In this paper, a simple, robust and novel method based on surface-enhanced Raman spectroscopy coupled with thin-layer chromatography (TLC) was developed to directly quantify the biomarkers in human urine samples. This is the first time surface-enhanced Raman spectroscopy (SERS) was used to detect cotinine and 3HC in urine samples. The linear dynamic range for the detection of cotinine is from 40 nM to 8 μM while that of 3HC is from 1 μM to 15 μM. The detection limits are 10 nM and 0.2 μM for cotinine and 3HC, respectively. The proposed method was further validated by quantifying the concentration of both cotinine and 3HC in smokers’ urine samples. This TLC-SERS method allows the direct detection of cotinine in the urine samples of both active and passive smokers and the detection of 3HC in smokers.
Figure
Scheme of the procedure for detection of cotinine and 3HC  相似文献   

13.
Quantification of monosaccharides and disaccharides in five honey samples through surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS) using HgTe nanostructures as the matrix and sucralose as an internal standard has been demonstrated. Under optimal conditions (1× HgTe nanostructure, 0.2 mM ammonium citrate at pH 9.0), the SALDI-MS approach allows detection of fructose and maltose at the concentrations down to 15 and 10 μM, respectively. Without conducting tedious sample pretreatment and separation, the SALDI-MS approach allows determination of the contents of monosaccharides and disaccharides in honey samples within 30 min, with reproducibility (relative standard deviation <15%). Unlike only sodium adducts of standard saccharides detected, sodium adducts and potassium adducts with differential amounts have been found among various samples, showing different amounts of sodium and potassium ions in the honey samples. The SALDI-MS data reveal that the contents of monosaccharides and disaccharides in various honey samples are dependent on their nectar sources. In addition to the abundant amounts of monosaccharides and disaccharides, oligosaccharides in m/z range of 650???2700 are only detected in pomelo honey. Having advantages of simplicity, rapidity, and reproducibility, this SALDI-MS holds great potential for the analysis of honey samples.
Figure
?  相似文献   

14.
In the present work a sensitive and accurate method by ion chromatography and conductimetric detection has been developed for the determination of biogenic amines in food samples at microgram per kilogram levels. The optimized extraction procedure of trimethylamine, triethylamine, putrescine, cadaverine, histamine, agmatine, spermidine, and spermine from real samples, as well as the separation conditions based on a multilinear gradient elution with methanesulfonic acid and the use of a weak ionic exchange column, have provided excellent results in terms of resolution and separation efficiency. Extended calibration curves (up to 200 mg/kg, r?>?0.9995) were obtained for all the analyzed compounds. The method gave detection limits in the range 23–65 μg/kg and quantification limits in spiked blank real samples in the range 65–198 μg/kg. Recovery values ranged from 82 to 103 %, and for all amines, a good repeatability was obtained with precision levels in the range 0.03–0.32 % (n?=?4). The feasibility and potential of the method were tested by the analysis of real samples, such as tinned tuna fish, anchovies, cheese, wine, olives, and salami.
Figure
IEC‐CD multiresidual method for accurate determinations of biogenic amines in foodstuffs  相似文献   

15.
We describe a new method for differential-pulse anodic stripping voltammetric determination of thallium(I) using a carbon paste electrode modified with dicyclohexyl-18-crown-6. The effect of supporting electrolyte (type and pH), accumulation and reduction potential, and of time and amount of modifier were investigated by differential pulse anodic stripping voltammetry. A method was then worked out for the determination of thallium at low levels. Under optimized conditions, the response to Tl(I) is linear in the range from 3.0 to 250 ng mL?1. The detection limit is 0.86 ng mL?1. The sensor displays good repeatability (with a relative standard deviation of ±2.70 % for n?=?7) and was applied to the determination of Tl(I) in water, hair samples, and certified reference materials.
Figure
Crown ethers allow only some ions to entry and complex formation that their sizes equal to ether cavity.  相似文献   

16.
A novel rapid (20 min) fluorescent lateral flow test for chloramphenicol (CAP) detection in milk was developed. The chosen format is a binding-inhibition assay. Water-soluble quantum dots with an emission peak at 625 nm were applied as a label. Milk samples were diluted by 20 % with phosphate buffer to eliminate the matrix effect. The result of the assay could be seen by eye under UV light excitation or registered by a portable power-dependent photometer. The limit of CAP detection by the second approach is 0.2 ng/mL, and the limit of quantitation is 0.3 ng/mL.
Figure
Principle of proposed immunoassay of chloramphenicol using quantum dots  相似文献   

17.
18.
We report on a method for the determination of soy proteins in food samples via dispersive solid-phase immunoextraction using gold-coated magnetic nanoparticles (NPs) as a support. Soy proteins were first extracted using anti-soy protein antibodies immobilized on the NPs, and then quantified by measuring the increase in fluorescence of the long-wavelength fluorophore cresyl violet in the presence of the anionic surfactant sodium dodecyl sulfate at neutral pH in a flow system. The method involves the use of two standard or sample aliquots. The fluorescence intensity of one aliquot is directly measured whereas that of the other aliquot is measured after immunoextraction. The difference between the peak heights of both aliquots serves as the analytical information that is directly proportional to the protein concentration. The limit of detection is 0.35 mg L?1, the linear range is from 1 to 15 mg L?1, and the relative standard deviation is <?5 %. Proteins such as bovine serum albumin and globulins do not interfere at the same concentration level. The method was applied to the analysis of soy-based beverages and gave recoveries in the range between 80.0 and 107.3 %.
Figure
A selective method for soy protein determination in food samples using solid phase dispersive immunoextraction with Au-magnetic NPs as support is reported  相似文献   

19.
A dual cloud point extraction (dCPE) off-line enrichment procedure coupled with a hydrodynamic–electrokinetic two-step injection online enrichment technique was successfully developed for simultaneous preconcentration of trace phenolic estrogens (hexestrol, dienestrol, and diethylstilbestrol) in water samples followed by micellar electrokinetic chromatography (MEKC) analysis. Several parameters affecting the extraction and online injection conditions were optimized. Under optimal dCPE–two-step injection–MEKC conditions, detection limits of 7.9–8.9 ng/mL and good linearity in the range from 0.05 to 5 μg/mL with correlation coefficients R 2?≥?0.9990 were achieved. Satisfactory recoveries ranging from 83 to 108 % were obtained with lake and tap water spiked at 0.1 and 0.5 μg/mL, respectively, with relative standard deviations (n?=?6) of 1.3–3.1 %. This method was demonstrated to be convenient, rapid, cost-effective, and environmentally benign, and could be used as an alternative to existing methods for analyzing trace residues of phenolic estrogens in water samples.
Figure
A dual cloud point extraction (dCPE) off-line enrichment procedure coupled with a hydrodynamic–electrokinetic two-step injection online enrichment technique was successfully developed for simultaneous preconcentration of trace phenolic estrogens in water samples followed by MEKC analysis.  相似文献   

20.
A micellar electrokinetic chromatography method was developed for determination of 15 suspected fragrance allergens and preservatives. The target compounds are widely used as ingredients in many personal care products, and all of them are included in the European Regulation concerning cosmetic products. The method was optimized by using a central composite experimental design and response surface methodology. A modified chromatographic response function was defined to weigh the terms in the response function adequately. After optimization of experimental conditions, a background electrolyte of 100 mM sodium dodecyl sulphate and 24 mM sodium tetraborate and pH 9.0 was selected for the separation of the analytes. The developed methodology was evaluated in terms of linearity, limits of detection and quantification, precision and accuracy, showing appropriate values (i.e., R 2?=?≥0.99 and accuracy of 89–115 %). Finally, applicability of the micellar electrokinetic chromatography method was assessed by successfully quantifying fragrance allergens and preservatives in commercial personal care products. The most commonly found analyte was linalool (48.3 % of samples) followed by benzoic acid (37.6 %). All samples contained at least one of the target compounds, thus confirming the ubiquity of fragrance allergens and preservatives in personal care products.
Figure
Scheme of data transformation to obtain the modified chromatogoraphic response function (MCRF)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号