首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(12):1999-2013
Abstract

A simple, rapid, selective, and sensitive method for the derivative spectrophotometric determination of Hg(II) and its simultaneous determination in the presence of Zn(II) using 2‐(5‐bromo‐2‐pyridylazo)‐5‐diethylaminophenol in the presence of cetylpyridinium chloride, a cationic surfactant, has been developed. The molar absorption coefficient and analytical sensitivity of the 1∶1 Hg(II) complex at 558 nm (λmax) are 5.78×104 L mol?1 cm?1 and 0.67 ng mL?1, respectively. The detection limit of Hg(II) is 1.40×10?2 ng mL?1, and Beer's law is valid in the concentration range 0.05–2.40 µg mL?1. Overlapping spectral profiles of Hg(II) and Zn(II) complexes in zero‐order mode interfere in their simultaneous determination. However, 0.10–2.00 µg mL?1 of Hg(II) and 0.065–0.650 µg mL?1 of Zn(II), when present together, can be simultaneously determined at zero cross point of the derivative spectrum, without any prior separation. The relative standard deviation for six replicate measurements of solutions containing 0.134 µg mL?1 of Hg(II) and 0.620 µg mL?1 of Zn(II) is 1.72 and 1.47%, respectively. The proposed method has successfully been evaluated for trace level simultaneous determination of Hg(II) and Zn(II) in environmental samples.  相似文献   

2.
This paper describes our research on the synthesis of the sorbent with chemically bonded ketoimine groups, and, furthermore, using this sorbent in the SPE technique to extract and preconcentrate trace amounts of metal ions in water samples. Surface characteristics of the sorbent were determined by elemental analysis, NMR spectra for the solid phases (29Si CP MAS NMR), and analysis of pore size distribution of the sorbent and nitrogen adsorption-desorption. The newly proposed sorbent with ketoimine groups was applied for the extraction and preconcentration of trace amounts of Cu (II), Cr (III) and Zn (II) ions from the water from a lake, post-industrial water and purified water unburdened back to the lake. The determination of the transition-metal ions was performed on an emission spectroscope with inductively coupled plasma ICP-OES. For the batch method, the optimum pH range for Cu (II) and Cr (III) extraction was equal to 5, and Zn(II)–to 8. All the metal ions can be desorbed from SPE columns with 10?mL of 0.5?mol?HNO3. The detection limits of the method were found to be 0.7?µg?L?1 for Cu (II), 0.08?µg?L?1 for Cr (III), and 0.2?µg?L?1 for Zn (II), respectively.  相似文献   

3.
In this research work, a new approach is developed for the extractive determination of chromium. The principle of this approach is based on the complexation reaction between 4-(4?-chlorobenzylideneimino)-3-methyl-5-mercapto-1,2,4-triazole (CBIMMT) in dichloromethane as a complexing reagent and chromium(III) in presence of potassium iodide to form a yellow coloured complex at room temperature. The 1:2:2 [Cr(III)-CBIMMT-iodide] ternary complex was quantitatively extracted in dichloromethane from 2.5 mol L?1 of hydrochloric acid medium which showed maximum absorption intensity at λmax 411 nm and was stable for more than 72 h. The values of molar absorption coefficient and Sandell’s sensitivity of the complex were found to be 0.7019 × 104 L mol?1 cm?1 and 0.00748 µg cm?2, respectively. The system adheres to Beer’s law from 1.5 to 6.0 µg mL?1; however, Ringbom’s plot suggests optimal concentration range was 1.8–5.8 µg mL?1. The limit of detection and limit of quantification of the approach is 0.26 and 0.79 µg mL?1. This approach was successfully used for the determination of chromium from wastewater effluents from the tannery industries (Kolhapur, MS, India), alloy samples and for separation of it from synthetic mixtures. The present experimental approach is apparently much simpler than the conventional method comprising multistep processes.  相似文献   

4.
The mean centering of ratio kinetic profiles method was used for the simultaneous determination of binary mixtures of Ni(II) and Zn(II) in water samples, without prior separation steps. The method is based on the difference in the rate of the reaction of Ni(II) and Zn(II) with xylenol orange at pH 5.3. The method allows rapid and accurate determination of Ni(II) and Zn(II). The analytical characteristics of the methods for the simultaneous determination of binary mixtures of Ni(II) and Zn(II) were calculated. The linear range was 0.025‐2.400 μg mL?1 and 0.025‐2.20 μg mL?1 for Zn(II) and Ni(II), respectively. Interference effects of common anions and cations were studied, and the method was successfully applied to the simultaneous determination of Zn(II) and Ni(II) in water samples.  相似文献   

5.
《Analytical letters》2012,45(1):84-93
Abstract

A simple, sensitive, and selective second-order-derivative spectrophotometric method has been developed for the simultaneous determination of palladium(II) and ruthenium(III) using 2-hydroxy-3-methoxy benzaldehyde thiosemicarbazone (HMBATSC) as a chromophoric reagent. The reagent (HMBATSC) reacts with Pd(II) and Ru(III) at pH 3.0, forming soluble yellowish green and dark brown species, respectively. Palladium and ruthenium present in the mixture were simultaneously determined without solving the simultaneous equations by measuring the second derivative amplitudes at 445 nm and 385 nm, respectively. Further, the Beer's law was obeyed in the range 0.21–12.78 µg mL?1 and 0.25–13.42 µg mL?1 for Pd(II) and Ru(III), respectively. A large number of foreign ions did not interfere in the present method. The proposed method was successfully applied for the determination of palladium in hydrogenation catalysts and ruthenium in water samples.  相似文献   

6.
《Analytical letters》2012,45(6):1209-1226
Abstract

A sensitive method for the simultaneous spectrophotometric determination of Fe(II), Cu(II), Zn(II), and Mn(II) in mixtures has been developed with the aid of multivariate calibration methods, such as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS). The method is based on the spectral differences of the analytes in their complexation reaction with 4‐(2‐pyridylazo)‐resorcinol (PAR) and the use of full spectra with wavelengths in the range of 300–600 nm. It was found that both the spectral positive and negative bands obtained against the PAR blank, are proportional to the concentration for each metal complex. The obtained linear calibration concentration ranges are 0.025–0.6, 0.05–0.8, 0.025–0.8, and 0.05–0.8 µg ml?1 for Fe(II), Cu(II), Zn(II), and Mn(II), respectively, and the LODs for the four metal ions were found to be approximately 1–3×10?2 µg ml?1. The proposed method was applied to a verification set of synthetic mixtures of these four metal ions, with models built in three different wavelength ranges, i.e., 300–450, 450–600, and 300–600 nm, corresponding to the positive, negative bands and their combinations, respectively. It was shown that the PLS model for the 300–600 nm range gave the best results (RPET=6.9% and average recovery ~100%; cf. PCR: RPET=9.5% and average Recovery ~110%). This method was also successfully applied for the determination of the four metal ions in pharmaceutical preparations, chicken feedstuff, and water samples.  相似文献   

7.
A novel inhibition-based glucose oxidase (GOx) biosensor for environmental chromium(VI) detection is described. An electropolymerized aniline membrane has been prepared on a platinum electrode containing ferrocene as electron transfer mediator, on which GOx is cross-linked by glutaraldehyde. The mechanism of the redox reaction on the electrode and the performance of the sensor are studied. The sensor's response to glucose decreases when it is inhibited by chromium(VI), with a lower detection limit of 0.49?µg?L?1, and the linear response range is divided into two parts, one of which is 0.49–95.73?µg?L?1 and the other is 95.73?µg?1 to8.05?mg?L?1. The enzyme membrane is shown to be completely reactivated after inhibition, retaining 90% activity over more than forty days. Interference to chromium(VI) determination from lead(II), copper(II), cadmium(II), chromium(III), cobalt(II), tin(II) and nickel(II) is found to be minimal, while high concentrations of mercury(II) and silver(I) may interfere with the determination of trace chromium(VI). The sensor has been used for chromium(VI) determination in soil samples with good results.  相似文献   

8.
A novel Rh(III)-imprinted amino-functionalised silica gel sorbent was prepared by a surface imprinting technique for preconcentration and separation of Rh(III) prior to its determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). Compared with the traditional solid sorbents and non-imprinted polymer particles, the ion-imprinted polymers (IIPs) had higher adsorption capacity and selectivity for Rh(III). The maximum static adsorption capacity of the imprinted and non-imprinted sorbent for Rh(III) was 29.86?mg?g?1 and 11.23?mg?g?1, respectively. The imprinted Rh(III) was removed with 2?mL of 3% thiourea?+?2?mol?L?1 HCl. The obtained imprinted particles exhibited excellent selectivity and rapid kinetics process for Rh(III). The relatively selective factor (αr) values of Rh(III)/Ru(III), Rh(III)/Au(III), Rh(III)/Pt(IV), Rh(III)/Ir(IV), Rh(III)/Pd(II) were 26.7, 39.0 29.2, 28.1, 43.7, respectively, which were greater than 1. The detection limit (3σ) of the method was 0.26?µg?L?1. The relative standard deviation of the method was 1.79% for eight replicate determination of 10?µg of Rh3+ in 200?mL water sample. The method was validated by analysing standard reference material (GBW 07293), the results obtained is in good agreement with standard values. The developed method was also successfully applied to the determination of trace rhodium(III) in geological samples with satisfactory results.  相似文献   

9.
《Analytical letters》2012,45(3):589-602
Abstract

The UV‐VIS spectrophotometric methods for the determination of Os(VIII) (as OsO4) and Os(IV) (as OsCl6 2? complex) in their mixtures were developed. Quercetin (Q), a flavonoid compound, was used as a chromogenic reagent. Both direct and derivative spectrophotometry can be employed for the determination of Os(VIII). The calculation of the first‐derivative spectrum of the examined mixture and the use of the signal at 285.1 nm allows reaching a better detection limit (0.01 µg mL?1 Os) as compared with direct spectrophotometry (0.1 µg mL?1 Os). Relative standard deviations of the results are in the range of 0.87%–4.65% and 0.45%–1.15% for direct and derivative mode, respectively. Selective redox reaction of OsO4 with Q under the conditions used (0.05 M HCl, 1×10?4 M Q, 15 min heating at 70°C) makes the basis of its determination in mixtures with the OsCl6 2? complex. Quercetin does not react with the OsCl6 2? complex. The signals of the OsCl6 2? complex can be isolated from the examined mixtures by the calculation of the third‐order derivative spectra and the use of the values at 340.0 nm. The effectiveness of the reduction of OsO4 in chloride solutions has been studied by the developed method.  相似文献   

10.
在pH为5.0-5.4的乙酸-乙酸钠缓冲溶液中,克林霉素(Clin)与钯(Ⅱ)形成螯合阳离子,它能进一步与二碘荧光素(DIF),赤藓红(Ery),曙红Y(EY)等卤代荧光素类染料反应形成1:1:1的三元离子缔合物,此时将引起吸收光谱变化和荧光猝灭,同时还导致共振瑞利散射(RRS)的急剧增强并产生新的RRS光谱,钯(Ⅱ)-克林霉素与DIF,Ery和EY形成产物的最大散射波长分别位于285,287,32 1nm处,另外还有些较弱的散射峰存在。散射增强(ΔI)与克林霉素浓度在一定范围内成正比,可用于克林霉素的定量测定。对于DIF,Ery和EY体系的线性范围和检出限分别为0.025-2.1μg•mL-1和7.8 ng•mL-1,0.053-2.4μg•mL-1和16.0 ng•mL-1;以及0.038-2.4μg•mL-1和11.0 ng•mL-1。本文研究了适宜的反应条件,考察了共存物质的影响,表明方法有较好的选择性,基于三元离子缔合物的RRS光谱,发展了一种高灵敏、简便快速测定克林霉素的新方法。文中还对离子缔合物的组成,结构和反应机理,以及离子缔合物对吸收,荧光和RRS光谱的影响进行了讨论。  相似文献   

11.
Immobilization of β-cyclodextrin on Dowex resin as an insoluble polymeric matrix by covalent bond presents a new solid-phase medium for preconcentration of Pb (II) at trace level in environmental samples prior to its flame atomic absorption spectrometric determination. The method is based on the sorption of lead after passing on modified Dowex sorbent in a column. The effect of several parameters such as pH, flow rate of sample, eluent kind and volume was investigated. The sorption capacity of the matrix has been found to be 0.4996?mg?g?1 of adsorbent with the preconcentration factor of 250 for Pb (II). Nitric acid (3 M) as an eluent was sufficient to obtain quantitative recovery (>95%) for Pb (II). The optimum flow rate was 10?ml?min ?1. The calibration curve was linear in the range of (3–250?ng?mL?1) with a correlation coefficient of 0.9995. The limit of detection (LOD) based on three times the standard deviation of the blank was 1.37?ng?mL?1. The relative standard deviation (RSD) for determination of 10?ng?mL?1 and 100?ngmL?1 of Pb (II) was 3.00 % and 0.58 % (n?=?10), respectively. The method was successfully applied to determination of lead in some environmental samples such as tap water, river water, soil and rice.  相似文献   

12.
An iPod-based digital image colorimeter was developed for the determination of lead(II) in cassava. The method is based on the color values of a lead(II) solution following its reaction with dithizone. Lead(II) from cassava was extracted using an ultraviolet-digestion unit followed by the color-forming reaction and image capture using the ColorConc application operated on an iPod touch. The concentration was predicted by comparing the color values with those collected in a database. The time needed for complete digestion was 30?min. The determined concentrations of lead(II) were from 0.10 to 1.00?µg mL?1. The limits of detection and quantitation were 0.0120 and 0.0399?µg mL?1, respectively. The recovery values were 105?±?7.07% and 109?±?6.61% at 0.2?µg mL?1 and 0.4?µg mL?1 lead(II) (n?=?5). The reported method was demonstrated to be simple, accurate, rapid, precise, and low cost.  相似文献   

13.
《Analytical letters》2012,45(4):791-807
Abstract

Simultaneous determination of cysteine and homocysteine in binary mixtures was performed by application of neural networks on the spectral kinetic data. This method is based on the complexation of bivalent iron with 2,2′–bipyridin (bipy). Iron(III) is quantitatively reduced to iron(II) with cysteine and homocysteine in the presence of 2,2′–bipyridin producing iron(II)–bipy complex (λmax=522 nm), and it can be used as a visible spectrophotometric signal for indirect simultaneous determination of the cysteine and homocysteine concentrations. On the basis of the difference in the rate between the two reactions, these two amino acids can be determined simultaneously using principal component‐artificial neural networks (PC‐ANN). The parameters controlling behavior of the system were investigated and optimum conditions selected. Determinations were made over the concentration range 0.10–5.50 µg · mL?1 of cysteine and 0.1–5.00 µg · mL?1 of homocysteine. Applying this method satisfactorily to simultaneous determination of these amino acids with total relative standard error less than 5% validated the proposed method.  相似文献   

14.
The determination of total arsenic through As(V) anodic stripping voltammetry (ASV) is, in some cases, preferable over As(III) ASV. The As(V) ASV procedure has no chemical reduction step from As(V) into As(III), which results in decreased analysis time and no contamination from reducting reagents. A simple and reliable procedure of As(V) determination is proposed. Anodic stripping determination of trace As(V) at gold microelectrode ensembles in diluted HCl solution in the presence of dissolved oxygen is shown. The electrode is based on a carbon black (30%)–polyethylene composite. The sensor was prepared by gold electrodeposition on the surface of the composite electrode. The given sensor is cheap, reliable and stable, especially when electrochemical activation is employed. The experimental parameters for the electrochemical determination were optimized, namely 0.005?M HCl as the background electrolyte, the deposition potential ?2.2?V (versus Ag/AgCl in 1?M KCl) and 180?mV?s?1 linear scan rate. Calibration curves were obtained and were linear in [As(V)] over the 1.5–45?µg?L?1 range, with a LOD of 0.5?µg?L?1. The effect of common interfering species is studied. The electrochemical behaviour of As(III) form is studied in the same experimental conditions. It was found that As(III) is deposited at lower potentials (starting at ?0.6?V) and the sensitivity of As(III) detection is higher, but dependant on the presence of dissolved oxygen. The speciation of inorganic forms of arsenic is discussed.  相似文献   

15.
A continuous flow thin layer electrolysis cell with a Pt cathode in combination with a microwave plasma torch operated with Ar as working gas was used for the optical emission spectrometric determination of As with the hydride technique. Under the optimised conditions the limit of detection (3σ) in the case of the As(I) 228.81 nm emission line was 81 ng mL?1. Especially the influence of the transition metals Cu(II), Fe(III) and Ni(II), of the hydride forming elements Sb(III), Se(IV) and Sn(II) and of Na on the determination of As was studied. Cu(II) was found to be the strongest interferent, as in the presence of 100 µg mL?1 of Cu(II) the signal for 3 µg mL?1 of As was reduced to 4% of the signal without interferent. Sn(II) and Sb(III) were found to yield an increase of the signal for As. L-cysteine and KI/ascorbic acid (1 : 1) at a concentration of 2% were found effective to reduce the interferences of Cu(II), Fe(III) and Ni(II). For a solution containing 3 µg mL?1 of As and 100 µg mL?1 of Ni(II) it was shown that in the presence of L-cysteine or KI/ascorbic acid the signal for As was 99% and 94% of the one without interferent, whereas it was only 43% without masking reagents. The procedure could be used for the determination of As in a digested coal fly ash standard reference material (NIST SRM 1633a®) with a certified value of 145 ± 15 µg g?1 for As. A concentration of 131 ± 15 µg g?1 was found. Additionally, As could be determined in two process water samples from a copper refinery. It was found that the amount of As determined with ECHG-MPT-OES agrees well with the values determined by FAAS and ICP-OES at the 0.02 and 1.6 g L?1 level, respectively.  相似文献   

16.
A rapid, simple, and reliable competitive immunoassay was developed for measurement of lead ions Pb(II) in environmental samples. Avian antibodies were produced against Pb(II). Since lead ions are too small to elicit an immune response, the metal was coupled to protein carrier Bovine serum albumin (BSA) using a bifunctional chelator 1-(4-isothiocyanobenzyl) ethylenediamine N,N,N′,N′-tetra acetic acid (ITCBE). Poultry birds (layers) were immunised with this Pb(II)–ITCBE–BSA immunoconjugate and the avian antibodies (IgY) isolated from egg yolk recognised Pb(II)-ITCBE complexes as capture reagent and a Pb(II)–ITCBE conjugate of Alkaline phosphatase as an enzyme label. Antibody reaction was optimised for different concentrations of antigen and antibody dilutions. Cross reactivity with other metals were below 1% in competitive ELISA. The IC50 value of this avian antibody was 0.19?µg?mL?1. The detection range and the detection limit were 0.02–1000?µg?mL?1and 0.2?µg?mL?1, respectively.  相似文献   

17.
仉华 a  c  张炎b  李全民 a  杜新贞c 《中国化学》2009,27(3):518-522
以Cu(II)为光谱探针建立了一种高选择性、高灵敏度测定异烟肼的新方法。试验表明:在pH 6.0时,Cu(II)可被异烟肼还原生成Cu(I),反应生成的Cu(I) 与SCN-反应生成CuSCN白色乳状沉淀,在硝酸钠的存在下该沉淀可被浮选至水相表面。通过测定水相中剩余Cu(II)的量,可以间接测定异烟肼的含量。已反应Cu(II) 的量与异烟肼的浓度呈良好的线性关系,线性范围为0.050-4.50 µg mL-1,检出限为0.048 µg mL-1。该法已经成功的用于药物样品和病人尿液样品中异烟肼含量的测定。  相似文献   

18.
《Analytical letters》2012,45(14):2365-2375
Abstract

A sensitive and selective spectrophotometric method is proposed for the rapid determination of cadmium(II) using, p,p′‐dinitro‐sym‐diphenylcarbazid, directly in aqueous solution. The reaction between cadmium(II) and p,p′‐dinitro‐sym‐diphenylcarbazid occurs immediately in strong basic media (0.02 N sodium hydroxide solution). The complex shows a maximum of absorption at 630–640 nm, and the absorbance remains stable for at least 24 h. The method allows the cadmium determination over the range 0.5–6.0 µg mL?1, with a molar absortivity of 2.05×104 L mol?1 cm?1 and features a detection limit of 0.13 ppm. The interferences caused by several ions [Ca(II), K(I), Ba(II), Al(III), Pb(II), Zn(II), Cl?1, NO3 ?, SO4 2?], which are present in most of environmental samples, were determined. The validation of the spectrophotometric method was done by recovery test of cadmium(II) in tap water and sea water. The results show that the proposed method has been successfully applied to the determination of cadmium(II) in water samples.  相似文献   

19.
In pH 4.9 Britton-Robinson buffer solution, methotrexate (MTX) reacted with thallium(III) to form a 3∶1 chelate. This resulted in great enhancement of second-order scattering (SOS) spectra and frequency doubling scattering (FDS) spectra and appearance of new SOS and FDS spectra. Their maximum wavelengths were located at 520 and 390 nm, respectively. The increments of scattering intensities (ΔI) were directly proportional to the concentrations of MTX in the ranges of 0.022—2.0 μg•mL-1 (SOS method) and 0.008—2.5 μg•mL-1 (FDS method). The methods exhibited high sensitivities. The detection limits for MTX were 7.4 ng•mL-1 (SOS method) and 2.3 ng•mL-1 (FDS method), respectively. The optimum conditions of the reaction, the influencing factors and the effects of coexisting substances were investigated. A highly sensitive, simple and fast method for the determination of MTX has been developed. The method can be applied satisfactorily to the determination of MTX in human serum samples. In this work, the charge distribution of MTX was calculated by a CNDO quantum chemistry method. In addition, the reaction mechanism was discussed.  相似文献   

20.
A new extraction flotation spectrum method for indirect determination of trace amounts of sulfide by ammonium sulfate‐ethanol‐water system was developed. It showed that Cu(II) could combine with S2? into precipitate (CuS) which was floated in the surface of ethanol and water in the presence of ammonium sulfate. The sulfide can be indirectly determined by determining the flotation yield of Cu(II). The linear range from 2.4 × 10?8to 3.2 × 10?6g/mL and the detect limit of 2.0 × 10?8g/mL was achieved. The results showed the determination of S2? was not affected by Pb(II), Zn(II), Cd(II), Fe(II), Co(II),Ni(II), Mn(II) and Cl?, Br?, I?, etc. In the paper, the method was successfully applied to the determination of a trace amount of sulfide in polluted water samples with the advantages of simplicity of equipment, rapidity, low cost, etc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号