首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Anti-tauro 1 beta-hydroxycholic acid antisera were prepared by immunizing rabbits with N-(1 beta,3 alpha, 7 alpha, 12 alpha-tetrahydroxy-5 beta-cholan-24-oyl)-2- aminopropionic acid-bovine serum albumin (BSA) conjugate. The antisera raised had high affinity (1.25-1.46 x 10(9) M-1) and specificity for conjugated 1 beta-hydroxycholic acid; cross-reactivity for glyco 1 beta-hydroxycholic acid was 100% and that for the glycine and taurine conjugates of other 1 beta-hydroxylated bile acids ranged from 11.30 to 0.23%. Urinary concentrations of conjugated 1 beta-hydroxycholic acid were determined by radioimmunoassay in newborns, 0-20 d after birth, in amounts ranging from 0.29 to 18.51 micrograms/ml and in women in late pregnancy (less than 1.13 micrograms/ml), as well as in normal women (less than 0.12 microgram/ml).  相似文献   

2.
Forty-eight derivatives of phorbol (9) and isophorbol (14) were evaluated for their inhibition of human immunodeficiency virus (HIV)-1 induced cytopathic effects (CPE) on MT-4 cells, as well as their activation of protein kinase C (PKC), as indices of anti-HIV-1 and tumor promoting activities, respectively. Of these compounds, the most potent inhibition of CPE was observed in 12-O-tetradecanoylphorbol 13-acetate (8) and 12-O-acetylphorbol 13-decanoate (6). The former also showed the strongest PKC activation activity, while the latter showed no activity at 10 ng/ml. Both activities were generally observed in those phorbol derivatives with an A/B trans configuration, but not in the isophorbol derivatives with an A/B cis configuration. Acetylation of 20-OH in the phorbol derivatives significantly reduced the inhibition of CPE, as shown in 12-O-, 20-O-diacetylphorbol 13-decanoate (6a) (IC100=15.6 microg/ml) vs. compound 6 (IC100=0.0076 microg/ml), and 12-O-tetradecanoylphorbol 13,20-diacetate (8a) (IC100=15.6 microg/ml) vs. 12-O-tetradecanoylphorbol 13-acetate (8) (IC100=0.00048 microg/ml), except in the case of 12-O-decanoylphorbol 13-(2-methylbutyrate) (4) and phorbol 12,13-diacetate (9c). The reduction of a carbonyl group at C-3 abruptly reduced the inhibition of CPE, as observed in 3beta-hydroxyphorbol 12,13,20-triacetate (9f) (IC100=500 microg/ml) vs. phorbol 12,13,20-triacetate (9d) (IC100=62.5 microg/ml). Although 8 was equipotent in the inhibition of CPE, and activation of PKC, both activities were abruptly decreased by the acetylation of 20-OH and methylation of 4-OH [as in 8a and 4-O-methyl-12-O-tetradecanoylphorbol 13,20-diacetate (8b), respectively]. On the other hand, its positional isomer (12-O-acetylphorbol 13-tetradecanoate (8c) showed neither activities. The removal of a long acyl group in 8 led to a substantial loss of both activities, as shown in phorbol 13-acetate (9b). Of the 12-O-acetyl-13-O-acylphorbol derivatives, the highest inhibition of CPE was observed in 6, which has a dodecanoyl residue at C-13. Both an increase and decrease in the number of fatty acid carbon chains resulted in significant reduction of the inhibition of CPE.  相似文献   

3.
The simultaneous determination of inorganic anions by ion chromatography using a dynamically coated graphitized carbon column with cetyltrimethylammonium (CTA) ions was investigated with suppressed conductivity detection. Column preparations with CTA and sodium carbonate-sodium hydrogencarbonate concentration in the eluent were examined to optimize the separation of seven common anions (F-, Cl-, NO2-, Br-, NO3-, HPO(4)2- and SO(4)2-). Calibration curves were linear from 0.5 to 5 micrograms/ml for F-, from 1.0 to 10 micrograms/ml for Cl-, from 1.5 to 15 micrograms/ml for NO2-, from 2.0 to 20 micrograms/ml for Br- and NO3-, from 5.0 to 50 micrograms/ml for HPO(4)2- and from 3.0 to 30 micrograms/ml for SO(4)2- with correlation coefficients (r) of 0.999 or better. The relative standard deviations of peak areas were between 0.3 and 0.9% for 10 repeated measurements. The application of this newly developed method was demonstrated by the determination of inorganic anions in the water for pharmaceutical purposes. Using CTA-Br as the coating agent, a permanently coated ion-exchange column was obtained, which allowed efficient separations of seven anions without adding any coating agent to the eluent.  相似文献   

4.
A detailed account is given of the first chemical synthesis of hypoxanthine 7-N-oxide (5), which started from coupling of 6-chloro-5-nitro-4(3H)-pyrimidinone (7) with N-(4-methoxybenzyl)phenacylamine, generated in situ from the hydrochloride (8), and proceeded through cyclization of the resulting phenacylaminopyrimidinone (9) and removal of the 4-methoxybenzyl group. The results of catalytic hydrogenolysis, methylation followed by catalytic hydrogenolysis, and rearrangement under acidic conditions of 5 supported the correctness of the assigned structure. An ultraviolet spectroscopic approach suggested that the neutral species of 5 exists in H2O mainly as the N(7)-OH tautomer (21). In the in vitro bioassay of antileukemic activity against murine L5178Y cells, 5 was weakly cytotoxic, with IC50 of 100 micrograms/ml. It did not show any antimicrobial activity even at 1000 micrograms/ml. None of the 9-(4-methoxybenzyl) (11) and O-methyl (12, 13, and 14) derivatives was found to be antileukemic or antimicrobial.  相似文献   

5.
26-Iodopseudodiosgenin (8) and 26-iodopseudodiosgenone (9) were reacted with various nucleophiles (KSCN, KOCN, NaCN, NaN(3) and various amines) to give pseudodiosgenin derivatives (4, 12, 16-20, 26) and pseudodiosgenone derivatives (5, 13, 21-25, 27), respectively. The reactions of 8 and 9 with KOCN gave the elimination products (10) and (11), respectively. The reaction of 9 with NaCN gave 5alpha,26- (14) and 5beta,26-dicyanocholestan-3-one (15). The reaction of 8 with NaN3 gave triazepine derivative (30), while that of 9 gave 26-azidopseudodiosgenone (31). Compound 31 was converted into triazepine derivative (32) by heating at 120 degrees C. The cytotoxicity of the pseudodiosgenins and pseudodiosgenones on P-gp-underexpressing HCT 116 cells and P-gp-overexpressing Hep G2 cells was examined by MTT assay. Pseudodiosgenins 2, 4, 12 and 30 showed strong cytotoxic activity (IC50 values: 2.6+/-0.3-6.7+/-1.4 microM), as did pseudodiosgenones 3, 5, 11, 13, 21-25 and 27 (IC50 values: 1.3+/-0.3-6.4+/-0.3 microM) toward HCT 116 cells. Pseudodiosgenins 12, 16 and 30 (IC50 values: 1.2+/-0.7-2.2+/-0.6 microM) and pseudodiosgenones 22, 23, 25 and 27 (IC50 values: 0.6+/-0.1-2.5+/-0.3 microM) were highly cytotoxic to Hep G2 cells. Compounds 3 and 27 showed efficient antibacterial activity (MIC: 15.6, 10.4 microg/ml) and (MIC: 7.8, 15.6 microg/ml) against Bacillus subtilis and Staphylococcus aureus, respectively.  相似文献   

6.
J Riu  D Barceló 《The Analyst》2001,126(6):825-828
Linear alkylbenzene sulfonates (LAS) were determined by solid-phase extraction (SPE), followed by capillary electrophoresis and mass spectrometry detection (CE-MS). The linear range of the proposed method varied from 33 to 316 and from 215 to 2057 micrograms L-1, depending on the compound, with limits of detection ranging from 4.4 to 23 micrograms L-1 when 200 ml of wastewater were preconcentrated. The analysis and confirmation of the polar carboxylic metabolites of LAS, the sulfophenyl carboxylic acids (SPC) was also achieved, and their presence was detected in both, influent and effluents of the sewage treatment plant (STP). [M - H]- ions were used for CE-MS confirmation and quantification. CE-MS diagnostic ions were the same ones used in LC-electrospray (ESI)-MS and corresponded to m/z 297, 311, 325 and 339 for C10LAS, C11LAS, C12LAS and C13LAS, respectively. For SPC identification, diagnostic ions corresponded to m/z 215 to 369 (with 14 mass unit steps) for C2 to C13SPC, respectively. LAS were determined in wastewater samples of the influent and effluent of three sewage treatment plants (STP), two of them using biological treatment with secondary settlement and receiving mainly domestic wastewater whereas one of the plants was operated with physiochemical treatment and received mainly industrial wastewater. The concentration levels of total LAS varied from 1000 to 1900 micrograms L-1 in the influents of STP, whereas in the effluents the concentrations varied from 125 to 360 micrograms L-1.  相似文献   

7.
Two new natural products, named paecilin A (1) and B (2), together with two known compounds secalonic acid D (3) and (11)-cytochalasa-6(12),13-diene-1,21-dione-16,18-dimethyl-7-hydroxy-10-phenyl-(7S*,13E,16S*,18S*) (4), were isolated from the mangrove endophytic fungus, Paecilomyces sp. (tree 1-7) from the South China Sea. 1D and 2D NMR experiments including COSY, HMQC, and HMBC were used for the determination of their structures. In our cytotoxicity assays, secalonic D (3) showed cytotoxicity toward KB cells with IC(50) < 1 microg ml(-1) and inhibiting human topoisomerase I with IC(50) at 0.16 micromol ml(-1). 1, 2, and 4 showed no activity to KB cells.  相似文献   

8.
A sensitive, selective, and rapid high-performance liquid chromatographic procedure was developed for the determination of isoxicam in human plasma and urine. Acidified plasma or urine were extracted with toluene. Portions of the organic extract were evaporated to dryness, the residue dissolved in tetrahydrofuran (plasma) or acetonitrile (urine) and chromatographed on a mu Bondapak C18 column preceded by a 4-5 cm X 2 mm I.D. column packed with Corasil C18. Quantitation was obtained by UV spectrometry at 320 nm. Linearity in plasma ranged from 0.2 to 10 micrograms/ml. Recoveries from plasma samples seeded with 1.8, 4 and 8 micrograms/ml isoxicam were 1.86 +/- 0.077, 4.10 +/- 0.107 and 8.43 +/- 0.154 micrograms/ml with relative standard deviations of 3.3%, 2.5% and 5.4%, respectively. The linearity in urine ranged from 0.125 to 2 micrograms/ml. The precision of the method was 3.3-9.0% relative standard deviation over the linear range.  相似文献   

9.
A sensitive and selective high-performance liquid chromatographic (HPLC) method for the analysis of 1,2-diethyl-3-hydroxypyridin-4-one (CP94, I) and its 2-(1-hydroxyethyl) metabolite (II) in rat blood is described. I, II and the internal standard, 1-propyl-2-ethyl-3-hydroxypyridin-4-one (CP95, III) were extracted into dichloromethane (3 x 5 ml, with the addition of 1 g of sodium chloride) from blood (0.25 ml plus 0.75 ml of pH 7.0 morpholinopropanesulphonic acid buffer). Extractability approached 100% for I and III, and approximately 65% for II under these conditions. Chromatographic analysis was carried out using a Hypercarb porous graphitised carbon HPLC column (10 cm x 0.46 cm). The mobile phase was 14:86 (v/v) acetonitrile-NaH2PO4 buffer (10 mM, containing 2 mM EDTA, pH adjusted to 3 with phosphoric acid) and detection was by ultraviolet at 280 nm. Calibration curves were linear (correlation coefficient greater than 0.99) and reproducible over the concentration range 0-80 micrograms/ml and the coefficient of variation was less than 16% even at low (1 microgram/ml) concentrations. The minimum quantifiable level was 0.5 microgram/ml for both I and II.  相似文献   

10.
Benzodiazepines in the blood samples typical of forensic science work are recovered from 100-250 microliters amounts of blood (diluted with aqueous sodium octyl sulphate to suppress protein binding) onto microcolumns of Porapak-T, and finally eluted into 60-microliters volumes of aqueous acetonitrile. The eluates may be taken directly for analysis by high-performance liquid chromatography (HPLC) with reductive amperometric detection at a pendent mercury drop electrode held at potentials down to -1.2 V vs. Ag/AgCl. For high sensitivity work the electrode is preceded by a coulometric detector fitted with porous carbon electrodes held at 0 V (proprietary reference electrode). The technique detects all of the commonly encountered benzodiazepines and others except clobazam, which contains no azomethine group. The detection limits generally are in the range 1-5 ng/ml (40-200 pg HPLC-injected) in hemolyzed human blood, with recovery values of 84-95%, depending on the actual benzodiazepine, over the range examined (less than or equal to 2.14 micrograms/ml). The respective values for the metabolites of nitrazepam are 8-12 ng/ml and 75-84%. The technique is very much less susceptible to the interferences afflicting other commonly applied techniques, and facilitates considerably the analysis of degraded samples.  相似文献   

11.
A relatively simple method for extraction of free fatty acids from cerebrospinal fluid with aminopropyl bonded-phase columns, and the estimation of palmitic acid (C16:0) and stearic acid (C18:0) concentrations by high-performance liquid chromatographic analysis is described. The values of C16:0 and C18:0 in patients with non-neurological disorders lie within a narrow range, with a mean (+/- S.D.) of 4.02 +/- 0.33 micrograms/ml for C16:0 and 2.72 +/- 0.39 micrograms/ml for C18:0.  相似文献   

12.
Anti-tauro 1 beta-hydroxycholic acid antisera were prepared by immunizing rabbits with N-(1 beta,3 alpha,7 alpha,12 alpha-tetrahydroxy-5 beta-cholan-24-oyl)glycine bovine serum albumin conjugate. The immunoglobulin G fraction was obtained by ammonium sulfate precipitation, followed by diethylaminoethyl cellulose column chromatography. The antibody was characterized using [2-3H]tauro 1 beta-hydroxycholic acid which has a high affinity (Ka = 1.09 x 10(9) M-1) and reasonable specificity. Cross-reactivity for glyco 1 beta-hydroxycholic acid was 100% and those for other 1 beta-hydroxylated bile acids ranged from 4.32 to 29.6%. Concentrations of conjugated 1 beta-hydroxycholic acid in urine of newborns at 0-20 d after birth were determined by radioimmunoassay to be significant (0.2-11.1 micrograms/ml), exhibiting a tendency to increase during the 20 d after birth.  相似文献   

13.
A sensitive method for the simultaneous high-performance liquid chromatographic determination of clarithromycin and its active metabolite in plasma and urine is described. Alkalinized samples were coextracted with an internal standard and analyzed on a C8 column using electrochemical detection. Recoveries were greater than or equal to 85% and consistent. Standard curves for plasma were linear in the range 0-2 micrograms/ml for both compounds (r greater than 0.99), with limits of quantification of approximately 10.03 micrograms/ml (0.5-ml sample). Within-day and day-to-day precision were good, with coefficients of variation mostly within +/- 5%; accuracy for both compounds were routinely within 90-110% of theoretical values. Standard curves for urine were linear in the range 0-100 micrograms/ml with limits of quantification of 0.5 micrograms/ml (0.2-ml sample). Urine assays also had similar within-day and day-to-day precisions and accuracy.  相似文献   

14.
A simple, specific and rapid reversed-phase high-performance liquid chromatographic (HPLC) procedure for sotalol determination is described requiring small plasma volumes. The high recovery of sotalol from plasma and the high precision of measurement obviate the need for an internal standard. Plasma samples (300 microliters) were deproteinised with 50 microliters of 70% (w/w) perchloric acid in disposable glass tubes. After vortex-mixing and centrifugation, 30 microliters of 4 M K2HPO4 were added followed by gentle shaking. A 20-microliters aliquot was then injected (by autosampler) for HPLC analysis. Chromatography was performed on a glass-lined 250 mm x 4 mm 5-micron C18 steel column. The mobile phase was 6% (v/v) acetonitrile in 0.08 M KH2PO4 buffer (pH 4.6). The flow-rate was 0.8 ml/min. Detection was by fluorescence with excitation and emission wavelengths at 235 and 310 nm, respectively. The retention time for sotalol was 7.1 min. Calibration was linear from 0.16 to 10 micrograms/ml in plasma (r greater than 0.999 for detector response to sotalol). The minimum concentration for quantitation was 0.08 micrograms/ml [within assay coefficient of variation (C.V.) less than 5%]. Recovery was near quantitative (greater than 98%) and replicate (intra-assay precision was less than 5% C.V.). Analysis of samples (n = 10) at concentrations of 0.42 and 4.2 micrograms/ml gave mean values of 0.44 and 4.3 micrograms/ml, respectively. The inter-assay C.V. values were 4.5 and 2.2%, respectively. Other clinically used antiarrhythmic drugs did not interfere. This assay can be performed using other commercial C18 analytical columns by suitable adjustment of mobile phase flow-rate and acetonitrile composition.  相似文献   

15.
Lamotrigine is an investigational anticonsulvant drug undergoing clinical trials. A simultaneous assay was developed to quantitate lamotrigine and its major metabolite, lamotrigine 2-N-glucuronide, from guinea pig whole blood. The extraction procedure and reversed-phase high-performance liquid chromatographic (HPLC) assay employed sodium dodecylsulfate (SDS) as an ion-pairing reagent to selectively separate lamotrigine and lamotrigine 2-N-glucuronide from endogenous blood components, other anti-convulsant drugs, and their metabolites. The mobile phase was composed of acetonitrile-50 mM phosphoric acid (pH 2.2) containing 10 mM SDS (33:67, v/v), and components were detected at 277 nm. The total coefficients of variance (C.V.) for the blood assay were less than or equal to 9.4% for lamotrigine (0.25-20.0 micrograms/ml) and less than or equal to 13.4% for the glucuronide metabolite (0.25-10.0 micrograms/ml). Separate assays for lamotrigine and its glucuronide in urine were developed. In order to quantitate low levels of lamotrigine in guinea pig urine, lamotrigine was extracted with tert.-butyl methyl ether-ethyl acetate (1:1). The total C.V. for lamotrigine quantitation in urine was less than or equal to 7.5% (0.10-10.0 micrograms/ml). For the determination of lamotrigine 2-N-glucuronide, urine was diluted with an SDS-phosphoric acid buffer (1:4) and injected directly onto the HPLC system, total C.V. less than or equal to 4.2% (0.5-50 micrograms/ml).  相似文献   

16.
The automated determination of amifloxacin and two of its principal metabolites in human plasma and urine by column-switching high-performance liquid chromatography is described. Plasma or urine samples, diluted 1:1 with 0.5 M sodium citrate buffer pH 2.5, were directly injected onto a cation-exchange pre-column. Following a 2.0-min wash of the pre-column with water at a flow-rate of 1.1 ml/min, the effluent from the pre-column was directed to the analytical column by a column-switching device. The precision of the plasma and urine methods ranged from a +/- 1.9 to +/- 3.6% for all compounds. The accuracies of the methods were within a range of -3.3% to 6.4% of the nominal values for all compounds. Linear responses were observed for all the standards in the range 0.10-5.0 micrograms/ml for plasma and 0.50-100 micrograms/ml for urine for all three compounds. The minimum quantifiable levels were 0.10 and 0.50 micrograms/ml for plasma and urine, respectively. The analytical methods may be used to quantify amifloxacin and the piperazinyl-N-desmethyl and piperazinyl-N-oxide metabolites in plasma and urine samples obtained from humans, monkeys, dogs and rats.  相似文献   

17.
Taher MA  Puri BK  Malik AK 《Annali di chimica》2001,91(5-6):319-330
A column preconcentration method has been developed for the determination of trace amounts of manganese by preconcentration on 2-nitroso-1-naphthol-4-sulfonic acid (nitroso-S)-tetradecyldimethylbenzylammonium (TDBA) naphthalene as an adsorbent using a simple funnel tipped glass tube. Manganese reacts with nitroso-S to form a water soluble brown colored chelate anion. The chelate anion forms a water insoluble Mn-Nitroso-S-TDBA ion pair on naphthalene packed in a column in the pH range 9.6-10.5 at a flow rate of 1-2 ml/min. The solid mass consisting of manganese complex and naphthalene is dissolved in 5 ml of dimethylformamide (DMF) and the metal determined by second derivative spectrophotometry. The calibration curve is linear in the concentration range 0.25-35.0 micrograms of Mn in 5 ml of the final DMF solution. Eight replicate determinations of 25 micrograms of standard manganese solution give a mean peak height of 4.0 with a correlation coefficient of 0.9995 and relative standard deviation of +/- 1.1%. The sensitivity was calculated to be 0.502(d2 A/d lambda 2)/microgram ml-1 from the slope of the calibration curve. The detection limit was 0.020 microgram ml-1 for manganese at the minimum instrumental settings (signal to noise ratio = 2). Various parameters effecting the method such as the effect of pH, volume of aqueous phase and interference of a number of metal ions on the determination of manganese have been evaluated to optimize the conditions for its determination in standard alloys and biological samples.  相似文献   

18.
A high-performance liquid chromatographic (HPLC) method employing a C18 reversed-phase column, a mobile phase of sodium acetate and methanol, and an ultraviolet detector was developed for the analysis of 5-ethylpyrimidines and 5-methylpyrimidines in plasma. Samples were prepared for HPLC by sequential cation-exchange and anion-exchange column chromatography. Linear standard curves were obtained for samples containing 0.05-50 micrograms/ml 5-ethyl-2'-deoxyuridine and 5-ethyluracil, 0.05-10 micrograms ml 5-(1-hydroxyethyl)uracil, and 0.1-50 micrograms/ml thymidine, thymine and 5-hydroxymethyluracil. Applicability of the method to determination of the kinetics of 5-ethyl-2'-deoxyuridine elimination by the isolated perfused rat liver was demonstrated; clearance of the drug was 1.29 ml/min.  相似文献   

19.
A method is described for the extraction of a phosphonic acid angiotensin-converting enzyme inhibitor from either urine or plasma, and subsequent quantitation using high-performance liquid chromatographic (HPLC) analysis and post-column o-phthalaldehyde reagent derivatization. The compound cannot be quantitatively extracted from the body fluids, but use of a fluorinated internal standard allowed for the computation of accurate results. With the use of an internal standard, excellent precision, linearity, and recovery were obtained for analyte response in both urine and plasma. In urine a working range of 0.2-10 micrograms/ml was found, with a limit of detection of 0.1 micrograms/ml. For plasma the working range was found to be 2-500 ng/ml, and the limit of detection was established as 1 ng/ml. Due to the non-polar character of the analyte at low pH values, it was possible to use novel extraction (solid-phase C8 column) and HPLC [poly(styrenedivinyl benzene) HPLC column] conditions to separate and quantitate the compound from plasma and urine.  相似文献   

20.
A method has been developed for the simultaneous determination of Tranilast, N-(3',4'-dimethoxycinnamoyl)anthranilic acid (N-5'), and metabolites in plasma and urine from humans, dogs and rodents administered N-5'. Total N-5' and metabolite N-3 conjugates were determined in human urine. Detection limits in plasma were 0.2 micrograms/ml for metabolite N-3-S and N-5' and 0.1 micrograms/ml for metabolites N-3 and N-4. In urine, detection limits were 2 micrograms/ml for metabolite N-3-S and N-5' and 1 micrograms/ml for metabolites N-3 and N-4. Metabolite N-4 was not identified in any sample assayed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号