首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Electroanalysis》2005,17(17):1511-1515
Differential pulse voltammetric determination of selenocystine (SeC) using selenium‐gold film modified glassy carbon electrode ((Se‐Au)/GC) is presented. In 0.10 mol?L?1 KNO3 (pH 3.20) solution, SeC yields a sensitive reduction peak at ?740 mV on (Se‐Au)/GC electrode. The peak current has a linear relationship with the concentration of SeC in the range of 5.0×10?8–7.0×10?4 mol?L?1, and a 3σ detection limit of SeC is 3.0×10?8 mol?L?1. The relative standard deviation of the reduction current at SeC concentration of 10?6 mol?L?1 is 3.88% (n=8) using the same electrode, and 4.19% when using three modified electrodes prepared at different times. The content of SeC in the selenium‐enriched yeast and selenium‐enriched tea is determined. The total selenium in ordinary or selenium‐enriched tea is determined by DAN fluorescence method. The results indicate that in selenium‐enriched yeast about 20% of total selenium is present as SeC and in selenium‐enriched tea SeC is the major form of selenoamino acids. The total selenium content in selenium‐enriched tea soup is 0.09 μgSe/g accounting by 7% compared with that in selenium‐enriched tea. Hence, only a little amount of selenium is utilized by drinking tea, and most selenium still stay in tealeaf. Uncertainty are 22.4% and 16.1% for determination of SeC in selenium‐enriched yeast and selenium‐enriched tea by differential pulse voltammetry (DPV) on (Se‐Au)/GC electrode, respectively.  相似文献   

2.
Acyclovir is an antiviral effective drug active compound. A glassy carbon electrode (GCE) was modified with an electropolymerized film of p‐aminobenzene sulfonic acid (p‐ABSA) in phosphate buffer solution (PBS). The polymer film‐modified electrode was used to electrochemically detect acyclovir. Polymer film showed excellent electrocatalytic activity for the oxidation of acyclovir. The anodic peak potential value of the acyclovir at the poly(p‐ABSA) modified glassy carbon electrode was 950 mV obtained by DPV. A linear calibration curve for DPV analysis was constructed in the acyclovir concentration range 2×10?7–9×10?6 mol L?1. Limit of detection (LOD) and limit of quantification (LOQ) were obtained as 5.57×10?8 and 1.85×10?7 mol L?1 respectively. The proposed method exhibits good recovery and reproducibility.  相似文献   

3.
The voltammetric behavior of two genotoxic nitro compounds (4‐nitrophenol and 5‐nitrobenzimidazole) has been investigated using direct current voltammetry (DCV) and differential pulse voltammetry (DPV) at a polished silver solid amalgam electrode (p‐AgSAE), a mercury meniscus modified silver solid amalgam electrode (m‐AgSAE), and a mercury film modified silver solid amalgam electrode (MF‐AgSAE). The optimum conditions have been evaluated for their determination in Britton‐Robinson buffer solutions. The limit of quantification (LQ) for 5‐nitrobenzimidazole at p‐AgSAE was 0.77 µmol L?1 (DCV) and 0.47 µmol L?1 (DPV), at m‐AgSAE it was 0.32 µmol L?1 (DCV) and 0.16 µmol L?1 (DPV), and at MF‐AgSAE it was 0.97 µmol L?1 (DCV) and 0.70 µmol L?1 (DPV). For 4‐nitrophenol at p‐AgSAE, LQ was 0.37 µmol L?1 (DCV) and 0.32 µmol L?1 (DPV), at m‐AgSAE it was 0.14 µmol L?1 (DCV) and 0.1 µmol L?1 (DPV), and at MF‐AgSAE, it was 0.87 µmol L?1 (DCV) and 0.37 µmol L?1 (DPV). Thorough comparative studies have shown that m‐AgSAE is the best sensor for voltammetric determination of the two model genotoxic compounds because it gives the lowest LQ, is easier to prepare, and its surface can be easily renewed both chemically (by new amalgamation) and/or electrochemically (by imposition of cleaning pulses). The practical applicability of the newly developed methods was verified on model samples of drinking water.  相似文献   

4.
A graphite electrode modified with silver (Ag‐CPE) has been applied to detect mercury(II) using differential pulse voltammetry (DPV). Under optimized conditions, the calibration curve is linear in the range from 5.0×10?8 mol L?1 to 1.0×10?4 mol L?1 of mercury(II). The detection limit was found to be 3.38×10?8 mol L?1 with a relative standard deviation (RSD) of 2.25 % (n=8). The proposed method was successfully applied for the detection of mercury(II) in leachate samples. The Ag‐CP composites were characterized using X‐ray diffraction (XRD), BET adsorption analysis and scanning electron microscopy (SEM).  相似文献   

5.
The voltammetric behavior of 3‐nitrofluoranthene and 3‐aminofluoranthene was investigated in mixed methanol‐water solutions by differential pulse voltammetry (DPV) at boron doped diamond thin‐film electrode (BDDE). Optimum conditions have been found for determination of 3‐nitrofluoranthene in the concentration range of 2×10?8–1×10?6 mol L?1, and for determination 3‐aminofluorathnene in the concentration range of 2×10?7–1×10?5 mol L?1, respectively. Limits of determination were 3×10?8 mol L?1 (3‐nitrofluoranthene) and 2×10?7 mol L?1 (3‐aminofluoranthene).  相似文献   

6.
A cobalt oxide nanocluster/overoxidized polypyrrole composite film electrochemical sensing interface was fabricated by two step electrochemical method. The electrochemical properties and electrocatalytic activity of the resulting modified electrode were also studied carefully. The results showed that this modified electrode exhibited good stability, good anti‐interference ability, as well as high electrocatalytic activity to the oxidation of glucose. The linear range for the amperometric determination of glucose was 2.0×10?7–2.4×10?4 mol L?1 and 2.4×10?4–1.4×10?3 mol L?1 with a detection limit of 5.0×10?8 mol L?1 (S/N=3), respectively. The sensitivity was 1024 µA mM?1 cm?2.  相似文献   

7.
Electrochemical behavior of dopamine (DA) was investigated at the gold nanoparticles self‐assembled glassy carbon electrode (GNP/LC/GCE), which was fabricated by self‐assembling gold nanoparticles on the surface of L ‐cysteine (LC) modified glassy carbon electrode (GCE) via successive cyclic voltammetry (CV). A pair of well‐defined redox peaks of DA on the GNP/LC/GCE was obtained at Epa=0.197 V and Epc=0.146 V, respectively. And the peak separation between DA and AA is about 0.2 V, which is enough for simultaneous determination of DA and AA. The peak currents of DA and AA were proportional with their concentrations in the range of 6.0×10?8–8.5×10?5 mol L?1 and 1.0×10?6–2.5×10?3 mol L?1, with the detection limit of 2.0×10?8 mol L?1 and 3.0×10?7 mol L?1 (S/N=3), respectively. The modified electrode exhibits an excellent reproducibility, sensibility and stability for simultaneous determination of DA and AA in human serum with satisfactory result.  相似文献   

8.
This work demonstrates gold nanoparticles (AuNPs)/functionalized multiwalled carbon nanotubes (f‐MWCNT) composite film modified gold electrode via covalent‐bonding interaction self‐assembly technique for simultaneous determination of salsolinol (Sal) and uric Acid (UA) in the presence of high concentration of ascorbic acid (AA). In pH 7.0 PBS, the composite film modified electrode exhibits excellent voltammetric response for Sal and UA, while AA shows no voltammetric response. The oxidation peak current is linearly increased with concentrations of Sal from 0.24–11.76 μmol L?1 and of UA from 3.36–96.36 μmol L?1, respectively. The detection limits of Sal and UA is 3.2×10?8 mol L?1 and 1.7×10?7 mol L?1 , respectively.  相似文献   

9.
Differential pulse voltammetry (DPV) at a carbon fibre rod electrode (CFRE) and a capillary carbon paste electrode (CPE) have been used for the determination of pesticides cymoxanil and famoxadone, respectively. In the cathodic potential range, optimum conditions were found for the determination of cymoxanil by DPV at CFRE at pH 4 with limit of quantification (LQ) of 5.9×10?7 mol L?1. In the anodic area, determination of famoxadone by DPV at CPE was performed at optimum pH 2 with LQ=1.4×10?7 mol L?1. Practical applicability of the newly developed methods was verified on spiked samples of river water and soil.  相似文献   

10.
Electroanalysis of benazepril HCl was successful using a carbon paste electrode modified with an ionic liquid crystal ( 1‐butyl‐1‐methylpiperidinium hexafluorophosphate) in presence of sodium dodecyl sulfate. The electrode performance was compared to ionic liquids (1‐n‐hexyl‐3‐methyl imidazolium tetrafluoroborate and 1‐butyl‐4‐methyl pyridinium tetrafluoroborate). Electrochemical determination of benazepril HCl was in the linear dynamic range of 8.89×10?7 to 1.77×10?5 mol L?1 (correlation coefficient 0.999) and LOD 7.17×10?9 mol L?1. benazepril HCl was determined using this sensor in presence of urine metabolites such as uric acid, ascorbic acid. Binary mixtures of dopamine/benazepril and amlodipine/benazepril were also determined successfully.  相似文献   

11.
The electrochemical reduction of carbamazepine in acetonitrile (ACN) and dimethylformamide (DMF) using a glassy carbon electrode and microelectrodes has been studied. The reduction process is consistent with an electrochemical‐chemical mechanism (EC) involving a two electron transfer followed by a first order reaction, as shown by the cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Half‐wave potential, number of electron transferred, diffusion coefficient and rate constant of the associated chemical reaction are reported. Limits of detection (LOD) for DPV are 0.92 and 0.76 µg mL?1 (3.89×10?6 mol L?1 and 3.21×10?6 mol L?1) in ACN and DMF, respectively. Precision (%RSD) and recovery (%) values when pharmaceutical compounds (200mg carbamazepine tablets) and spiked plasma samples were tested ranged from 1.09 to 9.04 % and % recoveries ranged from 96 to 104.1 %.  相似文献   

12.
Several problems for the direct electrochemical oxidation of reduced glutathione (GSH) challenge the usage of electroanalytical techniques for its determination. In this work, the electrochemical oxidation of GSH catalyzed by gold nanoparticles electrodeposited on Nafion modified carbon paste electrode in 0.04?mol?L?1 universal buffer solution (pH?7.4) is proved successful. The effect of various experimental parameters including pH, scan rate and stability on the voltammetric response of GSH was investigated. At the optimum conditions, the concentration of GSH was determined using differential pulse voltammetry (DPV) in two concentration ranges: 0.1?×?10?7 to 1.6?×?10?5?mol?L?1 and 2.0?×?10?5 to 2.0?×?10?4?mol?L?1 with correlation coefficients 0.9988, 0.9949 and the limit of detections (LOD) are 3.9?×?10?9?mol?L?1 and 8.2?×?10?8?mol?L?1, respectively, which confirmed the sensitivity of the electrode. The high sensitivity, wide linear range, good stability and reproducibility, and the minimal surface fouling make this modified electrode useful for the determination of spiked GSH in urine samples and in tablet with excellent recovery results obtained.  相似文献   

13.
A glassy carbon electrode coated the film of 4‐tert‐butyl‐1‐(ethoxycarbonylmethoxy)thiacalix[4]arene is designed for the determination of trace amounts of Hg2+. Compared with bare glassy carbon electrode, the modified electrode can improve the measuring sensitivity of Hg2+. Under the optimum experimental condition, the modified electrode in 0.1 mol L?1 H2SO4 + 0.01 mol L?1 KCl solution shows a linear voltammetric response in the range of 8.0 × 10?9 ~ 3.0 × 10?6 mol L?1 with detection limit 5.0 × 10?9 mol L?1 for Hg2+. The high sensitivity, selectivity, and stability of modified electrode also prove its practical application for a simple, rapid and economical determination of Hg2+ in water samples.  相似文献   

14.
A novel voltammetric method using the Ppyox/NFR/Au (poly pyrrole – nuclear fast red – gold) modified electrode was developed for simultaneous measurement of various combinations of ascorbic acid (AA) and methyldopa (MDA). Polypyrrole film was prepared by incorporation of nuclear fast red (NFR) as doping anion, during the electropolymerization of pyrrole onto a gold (Au) electrode in aqueous solution using cyclic voltammetric (CV) method, and then it was overoxidized at constant potential. Differential pulse voltammetry was utilized for the measurement of both analytes using modified electrode. Well‐separated voltammetric peaks were observed for ascorbic acid (AA) and methyldopa at the Ppyox/NFR/Au modified electrodes with peak separation of 0.210 V. It has been found that under optimum condition (pH 3.0), the oxidation of AA and MDA at the surface of the electrode occurs at a potential about 260 and 50 mV less positive than unmodified Au electrode respectively. The current catalytic oxidation peaks showed a linear dependent on the concentration of AA and MDA in the range of 9.0×10?6 to 1.0×10?3 and 1.0×10?7 to 2.0×10?5 mol L?1 respectively. The detection limit of 5.8×10?6 and 5.0×10?8 mol L?1 (S/N=3) were obtained for AA and MDA respectively. The modified electrode was used for determination of AA and MDA in some real samples such as human serum and tablet.  相似文献   

15.
Using 3‐Aminopropyltriethoxysilane(APTES) as a single silica source, an amino‐rich ultrafine organosilica‐nanoparticle‐modified Au electrode was fabricated, following the formation of (3‐mercaptopropyl)‐trimethoxysilane (MPTS) monolayer on Au surface (MPTS/Au). With cetyltrimethylammonium bromide as an additive, APTES‐based gel particles on the electrode have a narrow particle size distribution of 4–7 nm and “crystal‐like” structure. AFM and electrochemical characterization confirmed the successful grafting of APTES nanoparticles on MPTS/Au. The APTES/MPTS/Au electrode is highly sensitive for the detection of copper(II) ions with a detection limit as low as 1.6×10?12 mol L?1 (S/N>3) by square wave voltammetry. The current is linear to copper(II) concentration between 1.6×10?12 and 6.25×10?10 mol L?1.  相似文献   

16.
DNA was attached on the surface of an ethylenedidamine/polyglutamic(En/PGA) modified glassy carbon electrode (GCE) to create a novel voltammetric sensor (DNA/En/PGA/GCE) for dopamine (DA). This modified electrode exhibited a linear voltammetric response for DA in the range from 1.0×10?7 mol L?1 to 1×10?5 mol L?1, with a detection limit of 2×10?8 mol L?1. The detection of DA was found to be unaffected by the presence of ascorbic acid, uric acid, serotonin and folic acid. The method proposed was applied to detect DA in pharmaceutical dosage and human blood serum with good satisfactory results.  相似文献   

17.
Simultaneous determination of dihydroxybenzene isomers was investigated at a multi‐wall carbon nanotubes (MWCNTs)/β‐cyclodextrin composite modified carbon ionic liquid electrode in phosphate buffer solution (pH 7.0, 1/15 mol/L) in the presence of cationic surfactant cetylpyridinium bromide (CPB). With the great enhancement of surfactant CPB, the voltammetric responses of dihydroxybenzene isomers were more sensitive and selective. The oxidation peak potential of hydroquinone was about 0.024 V, catechol was about 0.140 V and resorcinol 0.520 V in differential pulse voltammetric (DPV) measurements, which indicated that the dihydroxybenzene isomers could be separated entirely. The electrode showed wide linear behaviors in the range of 1.2×10?7–2.2×10?3, 7.0×10?7–1.0×10?3, 2.6×10?6–9.0×10?4 mol/L for hydroquinone, catechol and resorcinol, respectively. And the detection limits of the three dihydroxybenzene isomers were 4.0×10?8, 8.0×10?8, 9.0×10?7 mol/L, respectively. The proposed method could be applied to the determination of dihydroxybenzene isomers in artificial wastewater, and the recovery was from 97.4% to 104.2%.  相似文献   

18.
This study describes a fast and simple methodology for the preparation of Cerium (III) Hexacyanoferrate (II) (CeHCF) nanoparticles (NPs). The NPs were characterized by fourier transform infrared (FTIR), x‐ray diffraction (XRD), scanning electron microscopy (SEM) and cyclic voltammetry (CV). The CeHCF cyclic voltammogram indicate a well‐defined redox pair assigned as Fe2+/Fe3+ in the presence of cerium (III), with a formal potential of Eθ′=0.29 V (v=100 mV s?1, KNO3; 1.0 mol/L, pH 7.0). The carbon paste electrode modified with CeHCF (CeHCF‐CPE) was applied to the catalytic electrooxidation of dopamine applying Differential Pulse Voltammetry (DPV). DPV showed linear response at two concentration ranges, from 9.0×10?7 to 8.0×10?6 and 9.0×10?6 to 1.0×10?4 mol/L, with an LOD of 1.9×10?7 and 1.0×10?5 mol/L, respectively. The CeHCF‐CPE exhibited selectivity against substances commonly found in biological samples, with redox potentials close to that of dopamine, such as urea and ascorbic acid (AA). Subsequently the CeHCF‐CPE was successfully applied to the detection of dopamine in simulated urine samples, with recovery percentages ranging between 99 and 103%.  相似文献   

19.
《Electroanalysis》2003,15(22):1778-1781
The voltammetric behavior of N,N‐dimethyl‐4‐amino‐2′‐carboxyazobenzene was investigated by differential pulse voltammetry (DPV) at a mercury meniscus‐modified silver solid amalgam electrode (m‐AgSAE). Conditions have been found for its determination by DPV at m‐AgSAE in the concentration range of 0.4 to 15 μmol L?1.  相似文献   

20.
《Electroanalysis》2003,15(22):1751-1755
A sensitive, selective and economic stripping voltammetry is described for the determination of trace amounts of zirconium at a morin‐modified carbon paste electrode (morin‐MCPE). Zirconium(IV) can be preconcentrated on the surface of the morin‐MCPE due to forming the Zr(IV)–morin complex. The complex produces two second‐order derivative anodic peaks at 0.69 V (vs. SCE) and 0.75 V when linear‐scanning from 0.0 to 1.0 V. The optimum analytical conditions are: 2.2 mol L?1 HCl, 0.0 V accummulation potential, 90 s accummulation time, 250 mV s?1 scan rate. A linear relationships between the peak currents at 0.75 V and the Zr(IV) concentration are in the range of 2.0×10?8 to 3.0×10?6 mol L?1. The detection limit is 1.0×10?8 mol L?1 (S/N=3) for 120 s accumulation. The RSD for determination of 4.0×10?7 mol L?1 Zr(IV) is 4.8% (n=8). The proposed method has been applied to determine zirconium in ore samples, unnecessarily extracted.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号