首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A chemically modified electrode was constructed for rapid, simple, accurate, selective and highly sensitive simultaneous determination of Cu(II) and Cd(II) using square wave anodic stripping voltammetry. The electrode was prepared by incorporation of SiO2 nanoparticles, coated with a newly synthesized Schiff base, in carbon paste electrode. The limit of detection was found to be 0.28 ng mL?1 and 0.54 ng mL?1 for Cu(II) and Cd(II), respectively. The proposed chemically modified electrode was used for the determination of copper and cadmium in several foodstuffs and water samples.  相似文献   

2.
Oxine (8-hydroxyquinoline) was used as an efficient and selective ligand for stripping voltammetry trace determination of Mn(II). A validated square-wave adsorptive cathodic stripping voltammetry method has been developed for determination of Mn(II) selectively as oxine complex using both the bare carbon paste electrode (CPE) and the modified CPE with 7 % (w/w) montmorillonite-Na clay. Modification of carbon paste with montmorillonite clay was found to greatly enhance its adsorption capacity. Limits of detection of 45 ng l?1 (8.19?×?10?10 mol L?1) and 1.8 ng l?1 (3.28?×?10?11 mol L?1) Mn(II) were achieved using the bare and modified CP electrodes, respectively. The achieved limits of detection of Mn(II) as oxine complex using the modified CPE are much sensitive than the detection limits obtained by most of the reported electrochemical methods. The developed stripping voltammetry method using both electrodes was successfully applied for trace determination of Mn(II) in various water samples without interferences from various organic and inorganic species.  相似文献   

3.
In this study, we demonstrated a highly sensitive electrochemical sensor for the simultaneous detection of Pb (II) and Cd (II) in aqueous solution using carbon paste electrode modified with Eichhornia crassipes powder by square wave anodic stripping voltammetry. The effect of modifier composition, pH, preconcentration time, reduction potential and time, and type of supporting electrolyte on the determination of metal ions were investigated. Pre-concentration on the modified surface was performed at open circuit. The modified electrode exhibited well-defined and separate stripping peaks for Pb (II) and Cd (II). Under optimum experimental conditions, a linear range for both metal ions was from 10 to 5000 μg L?1 with the detection limits of 4.9 μg L?1, 2.1 μg L?1 for Cd(II) and Pb (II), respectively. The modified electrode was found to be sensitive and selective when applied to determine trace amounts of Cd (II) and Pb (II) in natural water samples.  相似文献   

4.
We describe a silver(I)-selective carbon paste electrode modified with multi-walled carbon nanotubes and a silver-chelating Schiff base, and its electrochemical response to Ag(I). Effects of reduction potential and time, accumulation time, pH of the solution and the stripping medium were studied by differential pulse anodic stripping voltammetry and optimized. The findings resulted in a method for the determination of silver over a linear response range (from 0.5 to 235 ng?mL?1) and with a detection limit as low as 0.08 ng?mL?1. The sensor displays good repeatability (with the RSD of ±?2.75 % for 7 replicates) and was applied to the determination of Ag(I) in water samples and X-ray photographic films.
Figure
Open circuit accumulation of Ag(I) onto a surface of EHPO-MCPE and determination by Differential pulse anodic stripping voltammetry  相似文献   

5.
The voltammetric performance of an in situ plated antimony film screen-printed carbon electrode in hydrochloric acid, acetate buffer, and tartrate buffer was evaluated for the detection of copper(II) with differential pulse anodic stripping voltammetry. The tartrate buffer was superior, providing high sensitivity and good separation of copper and antimony stripping peaks. The analytical conditions for the determination of copper(II) were optimized. The detection limit was estimated to be 0.14?µg?L?1 copper(II) and the relative standard deviation for 2.5?µg?L?1 copper(II) was 3%. The applicability of the method was illustrated by the analysis of soil conditioner samples.  相似文献   

6.
《Analytical letters》2012,45(11):2273-2284
Abstract

A novel voltammetric method—anodic—using a bismuth/poly(aniline) film electrode has been developed for simultaneous measurement of Pb(II) and Cd(II) at low µg L?1 concentration levels by stripping voltammetry. The results confirmed that the bismuth/poly(aniline) film electrode offered high‐quality stripping performance compared with the bismuth film electrode. Well‐defined sharp stripping peaks were observed for Pb(II) and Cd(II), along with an extremely low baseline. The detection limits of Pb(II) and Cd(II) are 1.03 µg L?1 and 1.48 µg L?1, respectively. The bismuth/poly (aniline) electrode has been applied to the determination of Pb(II) in tap water samples with satisfactory results.  相似文献   

7.
《Analytical letters》2012,45(14):2683-2692
Abstract

DNA was immobilized onto a carbon nanotube surface through cyclic voltammetry, in which paste electrode (PE) was subjected to lead and copper trace ion analysis. Optimized conditions for square‐wave stripping voltammetry were then searched. The results indicated three other linear working ranges—3–21 mg l?1, 2–16 µg l?1, and 3–17 ng l?1 Pb(II) Cu(II)—within an accumulation time of 190 s in 0.1‐M ammonium phosphate electrolyte solutions of pH 10.0. At the optimized conditions, the detection limit (S/N) was pegged at 0.4 ng l?1 (1.93×10?12 M Pb(II) and 6.29×10?12 M Cu(II)). And the relative standard deviation at 10 mg l?1 Pb(II) and Cu(II) was a 0.074 and 0.069% precision, in 15 measurements. The method can be applied to assays of fish tissue.  相似文献   

8.
The well‐known method for the determination of mercury(II), which is based on the anodic stripping voltammetry of mercury(II), has been adapted for applications at the thin film poly(3‐hexylthiophene) polymer electrode. Halide ions have been found to increase the sensitivity of the mercury response and shift it more positive potentials. This behavior is explained by formation of mercuric halide which can be easily deposited and stripped from the polymer electrode surface. The procedure was optimized for mercury determination. For 120 s accumulation time, detection limit of 5 ng mL?1 mercury(II) has been observed. The relative standard deviation is 1.3% at 40 ng mL?1 mercury(II). The performance of the polymer film studied in this work was evaluated in the presence of surfactants and some potential interfering metal ions such as cadmium, lead, copper and nickel.  相似文献   

9.
We describe a new method for differential-pulse anodic stripping voltammetric determination of thallium(I) using a carbon paste electrode modified with dicyclohexyl-18-crown-6. The effect of supporting electrolyte (type and pH), accumulation and reduction potential, and of time and amount of modifier were investigated by differential pulse anodic stripping voltammetry. A method was then worked out for the determination of thallium at low levels. Under optimized conditions, the response to Tl(I) is linear in the range from 3.0 to 250 ng mL?1. The detection limit is 0.86 ng mL?1. The sensor displays good repeatability (with a relative standard deviation of ±2.70 % for n?=?7) and was applied to the determination of Tl(I) in water, hair samples, and certified reference materials.
Figure
Crown ethers allow only some ions to entry and complex formation that their sizes equal to ether cavity.  相似文献   

10.
A stable film of poly(3‐octylthiophene)–dihydroxyanthraquinone sulfonate has been synthesized electrochemically in non‐aqueous solution. The incorporation of dihydroxyanthraquinone sulfonate as an anionic complexing ligand into poly(3‐octylthiophene) film during electropolymerization was achieved and copper ions were accumulated by reduction on the electrode surface. The presence of dihydroxyanthraquinone sulfonate during the electrochemical polymerization of 3‐octylthiophene is shown to impact the sensitivity and the stability of the organic conducting film electrode response. The electroanalysis of copper(II) ions using conducting polymer electrode was achieved by differential pulse anodic stripping voltammetry with remarkable selectivity. The analytical performance was evaluated and linear calibration graphs were obtained in the concentration range of 50–400 ng mL?1 copper(II) ion for 240 seconds accumulation time and the limit of detection was found to be 7.8 ng mL?1. To check the selectivity of the proposed stripping voltammetric method for copper(II) ion, various metal ions as potential interferents were tested. The developed method was applied to copper(II) determination in certified reference material, NWRI‐TMDA‐61, trace elements in fortified water.  相似文献   

11.
We describe a new and promising type of selenium film electrode for anodic stripping voltammetry. This method is based on formation of copper selenide onto an in-situ formed selenium-film carbon electrode, this followed by Osteryoung square-wave anodic stripping voltammetry. Copper(II) is also in-situ electroplated in a test solution containing 0.01 mol L-1 hydrochloric acid, 0.05 mol L?1 potassium chloride and 500 µg L?1 Se(IV) at a deposition potential of ?300 mV. The well-defined anodic peak current observed at about 200 mV is directly proportional to the Cu(II) concentration over the range from 1.0 to 100 µg L?1 under the optimized conditions. The detection limit (three sigma level) is 0.2 µg L?1 Cu(II) at 180 s deposition time. Relatively less interferences are shown from most of metal ions except for antimony(III). The method can be applied to analyses of river water and oyster tissue with good accuracy.  相似文献   

12.
A novel electrochemical cell design is proposed to allow fast, reproducible and highly efficient convective transport of dissolved substances to screen‐printed electrochemical three‐electrode strips mounted on miniaturized plastic vessels, with the goal of improving detection limits in disposable electrochemical stripping field sensors. The experimental configuration has been tested for accumulation of the selected heavy metals ions Zn(II), Cd(II), and Pb(II), codeposited with bismuth ions on a carbon disk screen‐printed working electrode before detection by square wave anodic stripping voltammetry. Chemical and instrumental variables of the proposed device and associate electrochemical method were optimized. Selected parameters gave detection limits in the low ng mL?1 range with moderate deposition time (120 s). Practical applicability was tested on certified water and real samples (tap water and waste water), with acceptable results, suggesting potential usefulness for field environmental monitoring of heavy metals.  相似文献   

13.
A new composite electrode is described for anodic stripping voltammetry determination of Pb(II) at trace level in aqueous solution. The electrode is based on the use of multiwalled carbon nanotubes and Amberlite IR-120. The anodic stripping voltammograms depend, to a large extent, on the composition of the modified electrode and the preconcentration conditions. Under optimum conditions, the anodic peak current at around ?0.57 V is linearly related to the concentration of Pb(II) in the range from 9.6?×?10?8 to 1.7?×?10?6 mol L?1 (R?=?0.998). The detection limit is 2.1?×?10?8 mol L?1, and the relative standard deviation (RSD) at 0.24?×?10?6 mol L?1 is 1.7% (n?=?6). The modified electrode was applied to the determination of Pb(II) using the standard addition method; the results showed average relative recoveries of 95% for the samples analysed.
Figure
A new composite electrode is described for anodic stripping voltammetry determination of Pb(II) at trace level in aqueous solution. The electrode is based on the use of MWCNT and Amberlite IR-120. The method showed a good linearity for 9.6?×?10?8 - 1.7?×?10?6 mol L?1 and detection limit of 2.1?×?10?8 mol L?1.  相似文献   

14.
In this work for the first time, Fe3O4@SiO2 core–shell nanoparticles functionalized with isatin groups as a magnetic nanosorbent was applied for the simultaneous extraction of trace amounts of cadmium(II), nickel(II), lead(II), and zinc(II). The characterization of this nanosorbent was studied using Fourier transform infrared spectroscopy, scanning electron microscopy, energy-dispersive X-ray spectrometry, X-ray diffraction, vibrating sample magnetometer and thermogravimetric analysis. The effect of several factors such as pH, amount of sorbent, extraction time, type and volume of the eluent, sample volume, sorption capacity, and potentially interfering ions was investigated. In the selected conditions, it was observed that the limits of detection were 0.11 ng mL?1 for Cd(II), 0.28 ng mL?1 for Ni(II), 0.47 ng mL?1 for Pb(II), and 0.21 ng mL?1 for Zn(II), and the maximum sorption capacity of this suggested magnetic nanosorbent was 120, 112, 100, and 100 mg g?1 for Cd(II), Ni(II), Pb(II), and Zn(II), respectively. Also, the precision of the method (RSD%) for ten replicate measurements was found 2.5, 2.5, 2.8, and 3.1%, for Cd(II), Ni(II), Pb(II), and Zn(II) ions, respectively. Finally, the suggested procedure was applied for determination of cadmium(II), nickel(II), lead(II), and zinc(II) at trace levels in different water and agricultural products with satisfactory results.  相似文献   

15.
This research introduces the design of an adsorptive stripping voltammetric method for the cerium(III) determination at a carbon paste electrode, chemically modified with dipyridyl‐functionalized nanoporous silica gel (DPNSG‐CPE). The electroanalytical procedure comprised two steps: the Ce(III) chemical accumulation at ?200 mV followed by the electrochemical detection of the Ce(III)/dipyridyl complex, using anodic stripping voltammetry. The factors, influencing the adsorptive stripping performance, were optimized including the modifier quantity in the paste, the electrolyte concentrations, the solution pH and the accumulation potential or time. The resulting electrode demonstrated a linear response over a wide range of Ce(III) concentration (1.0–28 ng mL?1). The precision for seven determinations of 4 and 10 ng mL?1 Ce(III) was 3.2% and 2.5% (relative standard deviation), respectively. The prepared electrode was used for the cerium determination in real samples and very good recovery results were obtained.  相似文献   

16.
The applicability of commercial screen-printed gold electrodes (SPGEs) for the determination of Hg(II) in ambient water samples by square wave anodic stripping voltammetry has been demonstrated. Electrode conditioning procedures, chemical and instrumental variables have been optimized to develop a reliable method capable of measuring dissolved mercury in the low ng mL−1 range (detection limit 1.1 ng mL−1), useful for pollution monitoring or screening purposes. The proposed method was tested with the NIST 1641d Mercury in Water Standard Reference Material (recoveries 90.0–110%) and the NCS ZC 76303 Mercury in Water Certified Reference Material (recoveries 82.5–90.6%). Waste water samples from industrial origin and fortified rain water samples were assayed for mercury by the proposed method and by a reference ICP-MS method, with good agreement. Screen printing technology thus opens a useful way for the construction of reliable electrochemical sensors for decentralized or even field Hg(II) testing.  相似文献   

17.
《Analytical letters》2012,45(5):766-782
A combined homogeneous assay and colorimetric determination method using gold nanoparticles was developed for rapid determination of lead(II) in contaminated natural waters. The presence of lead(II) in the colloidal gold suspension causes a change in the absorbance of the suspension. An increase in the absorption property at 595 nm is accompanied by a change in the size of the gold nanoparticles. High concentrations of lead cause aggregation of the gold colloids. Colloidal gold nanoparticles were synthesized using tannic acid as the reducing agent; this reagent allowed selective determination of lead in 10 µL of water, with a detection limit of 310 ng mL?1 with an analysis time of 5 min. The coefficient of variation for lead(II) within the working range of the assay (520 ng mL?1–13 µg mL?1) varied from 1.3% to 9.2%. The limit of detection using this method with a sample volume of 50 µL was 60 ng mL?1. The coefficient of variation for lead over the working range of the determined concentrations (80 ng mL?1–25 µg mL?1) varied from 0.2% to 9.3%, while the values for the inter-day assay (n = 8) were less than 10%. The method was employed for the analysis of river, lake, marsh, and spring water; the recovery of lead was determined to be 72.5%–130% for 10 µL of water and 93.6%–114.7% for 50 µL.  相似文献   

18.
We report on a protocol for a simultaneous competitive immunoassay for tetracycline (TC) and chloramphenicol (CAP) on the same sensing interface. Conjugates of TC and of CAP with bovine serum albumin were first co-immobilized on a glassy carbon electrode modified with gold nanoparticles. In parallel, monoclonal anti-TC and anti-CAP antibodies were conjugated onto CdS and PbS nanoclusters, respectively. In a typical assay, the immobilized haptens and the added target analytes competed for binding to the corresponding antibodies on the nanoclusters. Subsequently, Cd(II) and Pb(II) ions are released from the surface of the corresponding nanoclusters by treatment with acid and then were detected by square wave anodic stripping voltammetry. The currents at the peak potentials for Cd(II) and Pb(II) were used as the sensor signal for TC and CAP, respectively. This multiplex immunoassay enables the simultaneous determination of TC and CAP in a single run with dynamic ranges from 0.01 to 50 ng mL?1 for both analytes. The detection limits for TC and for CAP are 7.5 pg mL?1 and 5.4 pg mL?1, respectively. No obvious nonspecific adsorption and cross-reactivity was observed in a series of analyses. Intra-assay and inter-assay coefficients of variation were less than 10 %. The method was evaluated by analyzing TC and CAP in spiked samples of milk and honey. The recoveries range from 88 % to 107 % for TC, and from 91 % to 119 % for CAP.
Figure
We developed a new multiplexed electrochemical immunoassay for simultaneous determination of tetracycline and chloramphenicol, using metal sulfide nanoclusters as recognition elements.  相似文献   

19.
The authors report on a disposable sensor for the differential pulse anodic stripping voltammetric (DPASV) determination of the ions Zn(II), Pb(II) and Cu(II). Simultaneous detection is accomplished by using a screen-printed carbon electrode (SPCE) co-modified with an in-situ plated bismuth (Bi)) film and gold nanoparticles (AuNPs). The synergistic effect of the Bi film, and the large surface and good electrical conductivity of the AuNPs strongly assist in the co-deposition of the three ions. Four well-defined and fully separated anodic stripping peaks, at 540 mV for Zn(II), 50 mV for Pb(II), 140 mV for Bi(III) and 295 mV for Cu(II), all vs. Ag/AgCl, can be seen. The modified SPCE was characterized by scanning electron microscopy, X-ray diffraction, cyclic voltammetry and electrochemical impedance spectroscopy. Under the optimized conditions, the sensor has a good response to these ions. The detection limits (at an S/N ratio of 3) are 50 ng·L?1 for Zn(II), 20 ng·L?1 for Pb(II), and 30 ng·L?1 for Cu(II). The method was applied to the determination of the 3 ions in spiked lake water samples.
Graphical abstract Schematic of screen-printed carbon electrode (SPCE) co-modified with a bismuth film and gold nanoparticles for electrochemical simultaneous determination of Zn(II), Pb(II) and Cu(II) by differential pulse anodic stripping voltammetric (DPASV).
  相似文献   

20.
Immobilization of β-cyclodextrin on Dowex resin as an insoluble polymeric matrix by covalent bond presents a new solid-phase medium for preconcentration of Pb (II) at trace level in environmental samples prior to its flame atomic absorption spectrometric determination. The method is based on the sorption of lead after passing on modified Dowex sorbent in a column. The effect of several parameters such as pH, flow rate of sample, eluent kind and volume was investigated. The sorption capacity of the matrix has been found to be 0.4996?mg?g?1 of adsorbent with the preconcentration factor of 250 for Pb (II). Nitric acid (3 M) as an eluent was sufficient to obtain quantitative recovery (>95%) for Pb (II). The optimum flow rate was 10?ml?min ?1. The calibration curve was linear in the range of (3–250?ng?mL?1) with a correlation coefficient of 0.9995. The limit of detection (LOD) based on three times the standard deviation of the blank was 1.37?ng?mL?1. The relative standard deviation (RSD) for determination of 10?ng?mL?1 and 100?ngmL?1 of Pb (II) was 3.00 % and 0.58 % (n?=?10), respectively. The method was successfully applied to determination of lead in some environmental samples such as tap water, river water, soil and rice.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号