首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
Collision induced dissociation (CID) combined with matrix assisted laser desorption ionization-ion mobility-mass spectrometry (MALDI-IM-MS) is described. In this approach, peptide ions are separated on the basis of mobility in a 15 cm drift cell. Following mobility separation, the ions exit the drift cell and enter a 5 cm vacuum interface with a high field region (up to 1000 V/cm) to undergo collisional activation. Ion transmission and ion kinetic energies in the interface are theoretically evaluated accounting for the pressure gradient, interface dimensions, and electric fields. Using this CID technique, we have successfully fragmented and sequenced a number of model peptide ions as well as peptide ions obtained by a tryptic digest. This instrument configuration allows for the simultaneous determination of peptide mass, peptide-ion sequence, and collision-cross section of MALDI-generated ions, providing information critical to the identification of unknown components in complex proteomic samples.  相似文献   

2.
A computational fluid dynamics (CFD) software package ANSYS Fluent was employed for simulation of ion transport at atmospheric pressure between a nano-electrospray ionization (nano-ESI) emitter and the mass spectrometer (MS) sampling inlet tube inside an improved air amplifier device incorporating a radiofrequency ion funnel. The flow field, electric field and the ion trajectory calculations were carried out in separate steps. Parallelized user-defined functions were written to accommodate the additional static and transient electric fields and the elastic ion-gas collisions with the Monte Carlo hard-sphere simulation abilities within Fluent’s environment. The ion transmission efficiency from a nano-ESI emitter to the MS sampling inlet was evaluated for different air amplifier and ion funnel operating conditions by tracking 250 sample reserpine ions. Results show that the high velocity gas stream and the external electric field cause a rapid acceleration of the ion beam and its dispersion along the centreline of the air amplifier which leads to reduction of the space-charge effect and the beam divergence. The radiofrequency potential applied to the ion funnel contributed to additional ion focusing.  相似文献   

3.
We report on the use of a jet disrupter electrode in an electrodynamic ion funnel as an electronic valve to regulate the intensity of the ion beam transmitted through the interface of a mass spectrometer in order to perform automatic gain control (AGC). The ion flux is determined by either directly detecting the ion current on the conductance limiting orifice of the ion funnel or using a short mass spectrometry acquisition. Based upon the ion flux intensity, the voltage of the jet disrupter is adjusted to alter the transmission efficiency of the ion funnel to provide a desired ion population to the mass analyzer. Ion beam regulation by an ion funnel is shown to provide control to within a few percent of a targeted ion intensity or abundance. The utility of ion funnel AGC was evaluated using a protein tryptic digest analyzed with liquid chromatography Fourier transform ion cyclotron resonance (LC-FTICR) mass spectrometry. The ion population in the ICR cell was accurately controlled to selected levels, which improved data quality and provided better mass measurement accuracy.  相似文献   

4.
The transmission of ions at low m/z can often be either necessary for an application or problematic (e.g., when large numbers of low m/z ions consume a large fraction of an ion trap's capacity). The low m/z ion transmission limit of an electrodynamic ion funnel has been characterized using both experimental and theoretical approaches. A theoretical model is developed based on a series of infinite wire conductors that represent the ring electrodes of the ion funnel. Mathematical relationships for both low and high m/z cutoffs of the idealized two-dimensional system are derived. The low m/z cutoff is also evaluated through a series of experiments that show it is influenced by both the RF frequency and the DC electric field gradient. However, unlike multipole ion guides, there is no marked dependence of the low m/z cutoff on the RF amplitude, in agreement with theoretical results. With this new understanding, ion funnels can be designed and configured to better match the m/z range requirements for various applications.  相似文献   

5.
Miniature mass spectrometer is more compact and portable than traditional commercial mass spectrometry, with more potential for application outside the laboratory. However, a miniature mass spectrometer is less sensitive than a commercial instrument, limiting its application scenarios. The ion transmission efficiency of the instrument is an essential factor affecting the sensitivity. Still, there are few works of literature on the quantitative study of the ion transmission efficiency of each component from a systematic perspective. In this paper, the Faraday cup coupled with a microcurrent signal testing instrument was used to measure the ions generated by nanoelectrospray ionization (nano-ESI), which have successfully gone through several components. Then the ion transmission efficiency of each component was quantified. Results showed that the front lens had the highest ion transmission efficiency of 39.7%, whereas the inlet and skimmer had the lowest ion transfer efficiency of 0.8% and 17.1%. Next, the influence of control parameters on ion transmission efficiency of critical components was investigated. If optimized, the ion funnel and the skimmer had the potential to improve their transmission efficiency by 120% and 79%, respectively. This paper shows the decreasing intensity distribution of ions in the whole transmission process and the transmission efficiency of each component, which can guide for improving the sensitivity of the miniature mass spectrometer.  相似文献   

6.
A new instrument that combines ion mobility spectrometry (IMS) separations with tandem mass spectrometry (MS(n)) is described. Ion fragmentation is achieved with vacuum ultraviolet photodissociation (VUV PD) and/or collision-induced dissociation (CID). The instrument is comprised of an approximately 1 m long drift tube connected to a linear trap that has been interfaced to a pulsed F(2) laser (157 nm). Ion gates positioned in the front and the back of the primary drift region allow for mobility selection of specific ions prior to their storage in the ion trap, mass analysis, and fragmentation. The ion characterization advantages of the new instrument are demonstrated with the analysis of the isomeric trisaccharides, melezitose and raffinose. Mobility separation of precursor ions provides a means of separating the isomers and subsequent VUV PD generates unique fragments allowing them to be distinguished.  相似文献   

7.
A program for Monte Carlo simulation of ion transport in non-linear ion mobility spectrometry, also known as field asymmetric ion mobility spectrometry (FAIMS) or differential mobility spectrometry (DMS), has been developed. Simulations are based on elastic collisions between the ions and the gas particles, and take into account the effects of flow dynamics and asymmetric electric fields. Using this program, the separation and diffusion of the ions moving in a planar DMS filtration gap are demonstrated. Ion focusing in a cylindrical filtration gap is also confirmed. A characteristic compensation voltage is found to provide insight for understanding separation in non-linear ion mobility spectrometry. The simulation program is used to study the characteristics of non-linear ion mobility spectrometry, the effect of the carrier gas flow, and the dependence of the compensation voltage and nonlinear mobility coefficient (α) on the applied asymmetric electric field.  相似文献   

8.
Because the optimum working pressure of ion funnel (IF) is very close to the typical operating pressure of a traditional drift tube for proton transfer reaction mass spectrometry (PTR-MS), it is possible to develop an IF drift tube for PTR-MS to improve the sensitivity. In this study, an ion funnel capable of functioning as a drift tube in a PTR-MS system was designed and studied by computer simulation. To optimize the geometrical and electrical parameters of the ion funnel, five ion funnel configurations were constructed. The merits and features of the respective ion funnels were evaluated, and the ion transmission characteristics were investigated and analyzed. An optimized ion funnel model was compared against the typical traditional drift tube that was used in PTR-MS for ion transmission, and it was found that the ion traveling trajectories in the ion funnel and traditional drift tube had different shapes and ion transmission efficiencies. Preliminary investigations revealed that this ion funnel improved the ion transmission efficiency by at least 10 times. The simulation and experiment results are helpful in guiding the design of an improved ion funnel to develop a PTR-MS system with higher sensitivity.  相似文献   

9.
A novel Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer has been developed for improved biomolecule analysis. A flared metal capillary and an electrodynamic ion funnel were installed in the source region of the instrument for improved ion transmission. The transfer quadrupole is divided into 19 segments, with the capacity for independent control of DC voltage biases for each segment. Restrained ion population transfer (RIPT) is used to transfer ions from the ion accumulation region to the ICR cell. The RIPT ion guide reduces mass discrimination that occurs as a result of time-of-flight effects associated with gated trapping. Increasing the number of applied DC bias voltages from 8 to 18 increases the number of ions that are effectively trapped in the ICR cell. The RIPT ion guide with a novel voltage profile applied during ion transfer provides a 3- to 4-fold increase in the number of ions that are trapped in the ICR cell compared with gated trapping for the same ion accumulation time period. A novel ICR cell was incorporated in the instrument to reduce radial electric field variation for ions with different z-axis oscillation amplitudes. With the ICR cell, called trapping ring electrode cell (TREC), we can tailor the shape of the trapping electric fields to reduce dephasing of coherent cyclotron motion of an excited ion packet. With TREC, nearly an order of magnitude increase in sensitivity is observed. The performance of the instrument with the combination of RIPT, TREC, flared inlet, and ion funnel is presented.  相似文献   

10.
离子迁移管是离子迁移谱仪的核心部分,它用来产生均匀的电场,以使不同迁移率的离子进行分离。本研究以丙酮为例,详细研究了本课题组所研制的真空紫外电离源-离子迁移谱仪中迁移管的电场参数对离子的灵敏度和分辨率的影响,发现电压的增大灵敏度增大,但是分辨率存在一个最佳的电压,这些结果可用于迁移谱的优化设计。  相似文献   

11.
The recently introduced ion trap for FT-ICR mass spectrometers with dynamic harmonization showed the highest resolving power ever achieved both for ions with moderate masses 500?C1000?Da (peptides) as well as ions with very high masses of up to 200?kDa (proteins). Such results were obtained for superconducting magnets of very high homogeneity of the magnetic field. For magnets with lower homogeneity, the time of transient duration would be smaller. In superconducting magnets used in FT-ICR mass spectrometry the inhomogeneity of the magnetic field in its axial direction prevails over the inhomogeneity in other directions and should be considered as the main factor influencing the synchronic motion of the ion cloud. The inhomogeneity leads to a dependence of the cyclotron frequency from the amplitude of axial oscillation in the potential well of the ion trap. As a consequence, ions in an ion cloud become dephased, which leads to signal attenuation and decrease in the resolving power. Ion cyclotron frequency is also affected by the radial component of the electric field. Hence, by appropriately adjusting the electric field one can compensate the inhomogeneity of the magnetic field and align the cyclotron frequency in the whole range of amplitudes of z-oscillations. A method of magnetic field inhomogeneity compensation in a dynamically harmonized FT-ICR cell is presented, based on adding of extra electrodes into the cell shaped in such a way that the averaged electric field created by these electrodes produces a counter force to the forces caused by the inhomogeneous magnetic field.  相似文献   

12.
Ion/ion proton transfer reactions involving mutual storage of both ion polarities in a linear ion trap (LIT) that comprises part of a hybrid triple quadrupole/linear ion trap mass spectrometer have been effected. Mutual ion storage in the x- and y-dimensions arises from the normal operation of the oscillating quadrupole field of the quadrupole array, while storage in the z-dimension is enabled by applying unbalanced radio-frequency amplitudes to opposing sets of rods of the array. Efficient trapping (>90%) is achieved for thermalized ions over periods of several seconds. Reactions were demonstrated for multiply charged protein/peptide cations formed by electrospray with anions derived from glow discharge ionization of perfluoro(methyldecalin) (PMD) introduced from the side of the LIT rod array. Doubly and singly charged protein ions are readily formed via ion/ion reactions. The parameters that affect ion/ion reactions are discussed, including the degree of RF unbalance on the LIT rods, vacuum pressure, nature of the buffer gas, reaction time, anion abundance, and the low mass cutoff for ion/ion reaction. The present system has a demonstrated upper mass-to-charge ratio limit of at least 33,000. The system also has high flexibility with respect to defining MS(n) experiments involving both collision-induced dissociation (CID) and ion/ion reactions. Experiments are demonstrated involving beam-type CID in the pressurized collision quadrupole (Q2) followed by ion/ion reactions involving the product ions in the LIT. Ion parking experiments are also demonstrated using the mutual storage ion/ion reaction mode in the LIT, with a parking efficiency over 60%.  相似文献   

13.
A dynamic method is applied to measure the mobility of gas-phase ions in the dual ion funnel interface of the electrospray source of a quadrupole orthogonal time-of-flight mass spectrometer. In a new operational mode, a potential barrier was formed in the second ion funnel of the mass spectrometer and then progressively increased. In this region, a flow of gas drags the ions into the mass spectrometer while the electric force applied by the potential barrier decelerates them. Ions with lower mobility can be carried by the gas flow more easily than those with high mobility. Thus, electrical forces can block the more mobile ions more easily. Hence, the electric barrier formed in the ion funnel permits only ions below a certain mobility threshold to enter the mass spectrometer. When the barrier voltage is increased, this threshold moves from high to low mobilities. Ions with mobilities above the threshold cannot enter the mass spectrometer, and their signal decreases to zero. Thus, in a barrier voltage scan, mass spectrometric signals of ions sequentially disappear. Differentiation of these decreasing ion signal curves produces peaks from which an ion mobility spectrum can be reconstructed. Blocking voltages, i.e., the positions of the peaks on the barrier voltage scale are directly related to the mobility of these ions. An internal calibration using ions with known mobility values helps determine the unknown ion mobilities and allows calculation of ionic cross sections.  相似文献   

14.
Initial results obtained using a new electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) mass spectrometer operated at a magnetic field 11.5 tesla are presented. The new instrument utilized an electrostatic ion guide between the ESI source and FTICR trap that provided up to 5% overall transmission efficiency for light ions and up to 30% efficiency for heavier biomolecules. The higher magnetic field in combination with an enlarged FTICR ion trap made it possible to substantially improve resolving power and operate in a more robust fashion for large biopolymers compared to lower field instruments. Mass resolution up to 106 has been achieved for intermediate size biopolymers such as bovine ubiquitin (8.6 kDa) and bovine cytochrome c (12.4 kDa) without the use of frequency drift correction methods. A mass resolution of 370,000 has been demonstrated for isotopically resolved molecular ions of bovine serum albumin (66.5 kDa). Comparative measurements were made with the same spectrometer using a lower field 3.5-tesla magnet allowing the performance gains to be more readily quantified. Further improvements in pumping capacity of the vacuum system and efficiency of ion transmission from the source are expected to lead to further substantial sensitivity gains.  相似文献   

15.
Ion mobility spectrometry with high electric fields complements the information from the spectra obtained using conventional time-of-flight ion mobility spectrometry by providing the field dependence of ion mobility. The formation and dissociation of ion clusters depending on the differences between high and low field strength is one process which has a considerable influence on the peak position in the resulting spectra. This process can be affected by the properties of substances. Therefore, one objective of our study was to determine possible influences of the nature and position of functional groups on the field dependence of ion mobilities. For this purpose, we investigated sets of compounds with different functional groups including chlorobenzenes, toluenes, anilines and phenols. Furthermore, it is known that ionic mass is an important parameter influencing the field dependence of ion mobility. Therefore, we also investigated unsubstituted aromatic hydrocarbons with different ionic masses. Although an influence of functional groups on the field dependence of ion mobilities was found, the ionic mass has a more significant influence. However, some isomers can be separated by applying high field amplitudes. Furthermore, the influence of ionic mass on the peak position is also more significant using high field amplitudes.  相似文献   

16.
Ion mobility spectrometry (IMS) is an analytical technique used for fast and sensitive detection of illegal substances in customs and airports, diagnosis of diseases through detection of metabolites in breath, fundamental studies in physics and chemistry, space exploration, and many more applications. Ion mobility spectrometry separates ions in the gas‐phase drifting under an electric field according to their size to charge ratio. Ion mobility spectrometry disadvantages are false positives that delay transportation, compromise patient's health and other negative issues when IMS is used for detection. To prevent false positives, IMS measures the ion mobilities in 2 different conditions, in pure buffer gas or when shift reagents (SRs) are introduced in this gas, providing 2 different characteristic properties of the ion and increasing the chances of right identification. Mobility shifts with the introduction of SRs in the buffer gas are due to clustering of analyte ions with SRs. Effective SRs are polar volatile compounds with free electron pairs with a tendency to form clusters with the analyte ion. Formation of clusters is favored by formation of stable analyte ion‐SR hydrogen bonds, high analytes' proton affinity, and low steric hindrance in the ion charge while stabilization of ion charge by resonance may disfavor it. Inductive effects and the number of adduction sites also affect cluster formation. The prediction of IMS separations of overlapping peaks is important because it simplifies a trial and error procedure. Doping experiments to simplify IMS spectra by changing the ion‐analyte reactions forming the so‐called alternative reactant ions are not considered in this review and techniques other than drift tube IMS are marginally covered.  相似文献   

17.
Atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) has proven a convenient and rapid method for ion production in the mass spectrometric analysis of biomolecules. This technique, like other atmospheric pressure ionization methods, suffers from ion loss during ion transmission from the atmosphere into the vacuum of the mass spectrometer. In this work, a simple model describing ion formation and ion motion towards the inlet capillary of the mass spectrometer is described. Both the gas flow and electric field near the MALDI plate were numerically calculated using the boundary element method (BEM). The ions were moving along with the gas flow and drifting in the electric field in accordance with their ion mobility properties. The ion signal dependence on an electric field strength obtained in the proposed model correlates well with experimental results.  相似文献   

18.
Enhancements to the ion source and transfer optics of our 9.4 T Fourier transform ion cyclotron resonance (ICR) mass spectrometer have resulted in improved ion transmission efficiency for more sensitive mass measurement of complex mixtures at the MS and MS/MS levels. The tube lens/skimmer has been replaced by a dual ion funnel and the following octopole by a quadrupole for reduced ion cloud radial expansion before transmission into a mass‐selective quadrupole. The number of ions that reach the ICR cell is increased by an order of magnitude for the funnel/quadrupole relative to the tube lens/skimmer/octopole. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
Atmospheric pressure interfaces were a fundamental structure for transferring air generated ions into the vacuum manifold of a mass spectrometer. This work is devoted to the characterization of ion transfer in metal capillaries through both experimental and simulated investigations. The impact of capillary configurations on ion transmission efficiency was evaluated using an electrospray mass spectrometer with various bent capillaries as the transfer devices. In addition, a numerical model has been set up by coupling the SIMION 8.0 and the computational flow dynamics for simulation study of ion migration in the complex atmospheric system. The transfer efficiency was found to be highly affected by the variation in electric field and the capillary geometry, revealing that the hydrodynamic and electric force were both dominant and interactional during the transmission process. The consistency of the results from the experimental analysis and simulation modeling proved the validity of the model, which was helpful for understanding ion activity in transfer capillaries. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
We propose a novel ion cyclotron resonance ion trap capable of confining ions even at high pressure. The trap consists of three capacitively coupled axial sections, each composed of four circular cross-section rods parallel to the magnetic field axis. Ion confinement along the magnetic field direction is provided by applying the same static voltage to each set of “endcap” rods. As for a two-dimensional quadrupole mass filter, a sufficiently high rf frequency (several MHz) leads to an “effective” electrostatic “pseudopotential” well with a minimum on the trap central axis. Ions are confined radially by the combination of an applied axial static magnetic field and a radially inward-directed electric field resulting from differential rf voltages applied to each set of four rods. Ion confinement properties are revealed from a Paul traplike “stability diagram,” whereas ion trajectories are analyzed in terms of Penning-type ion cyclotron rotation, magnetron rotation, and axial oscillation motional modes. Ion cyclotron frequency increases with the strength of the rf trapping field. Ion magnetron motion becomes stable if the rf voltage is high enough. Therefore, ion trajectories can be stable even in the presence of ion-neutral collisions. Adding an ac potential to a Penning trap should dramatically increase the upper mass detection limit.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号