首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
In the present work, a novel sensitive electrochemical potentiometric sensor for sensing Fe3+ ions based on 1,4-diaminoanthraquinone (DAQ) as a hydrophobic selector element was prepared to implement as an ion selective carbon paste electrode in the aqueous solutions. The adequate amounts of ionophore (5%), paraffin oil (25%) as a binder, Nanosilica (NS: 0.5%) multi-wall carbon nanotubes (MWCNTs: 1%) as a modifier, and graphite powder (68.5%) as an inert matrix was occupied to form the paste. This new FeCP sensor demonstrated a Nernstian slope of 19.7 ± 0.7 mV per decade over widish linear range between 1.0 × 10–8 to 1.0 × 10–2 mol L–1 at working pH range of 1.9–5.0 in the optimized conditions. The average elapsed time to response of electrode was about ~6 s for concentrations from lower (1.0 × 10?8 mol L–1) to higher (1.0 × 10?2 mol L–1) of Fe3+ ion solution. The selectivity of electrode toward Fe3+ ions in comparison with other cations was studied by matched potential method. The making FeCP sensor has been put to use successfully as an indicator electrode in analytical applications such as the potentiometric titration and determination of iron(III) ion in blend of different ions.  相似文献   

2.
A potentiometric sensor for lead(II) ions based on the use of 1,4,8,11‐tetrathiacyclotetradecane (TTCTD) as a neutral ionophore and potassium tetrakis‐(p‐chlorophenyl)borate as a lipophilic additive in plasticized PVC membranes is developed. The sensor exhibits linear potentiometric response towards lead(II) ions over the concentration range of 1.0×10?5–1.0×10?2 mol L?1 with a Nernstian slope of 29.9 mV decade?1 and a lower limit of detection of 2.2×10?6 mol L?1 Pb(II) ions over the pH range of 3–6.5. Sensor membrane without a lipophilic additive displays poor response. The sensor shows high selectivity for Pb(II) over a wide variety of alkali, alkaline earth and transition metal ions. The sensor shows long life span, high reproducibility, fast response and long term stability. Validation of the method by measuring the lower limit of detection, lower limit of linear range, accuracy, precision and sensitivity reveals good performance characteristics of the proposed sensor. The developed sensor is successfully applied to direct determination of lead(II) in real samples. The sensor is also used as an indicator electrode for the potentiometric titration of Pb(II) with EDTA and potassium chromate. The results obtained agree fairly well with data obtained by AAS.  相似文献   

3.
The present paper describes the development of a new chemically modified carbon paste electrode based on azithromycin (AMC) that considered as a selective aluminium recognition agent in the carbon paste electrode (CPE). This electrode was fully characterized in terms of composition, response time, usable pH range and temperature. The electrode exhibited a Nernstian response for Al3+ ion over a concentration range from 7.0 × 10–6 to 1.0 × 10–2 mol L–1 with a slope of 21.3 ± 0.18 mV decade–1 and the limit of detection was 6.0 × 10–6 mol L?1. It had a response time of about 6 s. The proposed sensor possesses a very good selectivity with respect to a variety of other cations. Finally this modified electrode was applied for the determination of the concentration of Al3+ ion in different water samples and the obtained results were comparable with those obtained with atomic absorption spectrometer (AAS).  相似文献   

4.
4,13-Didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) has been explored as a neutral ionophore for preparing polyvinyl chloride (PVC)-based membrane sensor selective to lead(II). The optimized membrane incorporating kryptofix22DD as the active material, nitrobenzene as plasticizer and sodium tetraphenylborate as an anion excluder and membrane modifier in PVC (in the weight ratio of 5.0: 63.0: 2.0: 30.0, respectively) was directly coated on the surface of graphite rod. The sensor exhibits a Nernstian slope (29.4 mV/decade) in the concentration range of 1.0 × 10–5 to 1.0 × 10–1 M Pb2+. The detection limit of the sensor is 6.5 × 10–6 M. The proposed sensor has a fast response time (~10 s), a satisfactory reproducibility and relatively long lifetime. The electrode shows high selectivity toward Pb2+ ion in comparison to other common cations. The proposed sensor is suitable for use in aqueous solutions in a wide pH range of 2.0–10.0. It was used as an indicator electrode for the end point detection in the potentiometric titration of Pb2+ ion with ethylenediaminetetraacetic acid (EDTA) and sodium iodide (NaI) solutions. The proposed sensor was successfully applied for the recovery of Pb2+ ions spiked in real water samples.  相似文献   

5.
《Analytical letters》2012,45(6):870-880
Abstract

An ion-selective electrode (ISE) was developed for the rapid determination of pseudoephedrine hydrochloride (PSEHCl) in pharmaceutical preparations. The electrode incorporates a PVC membrane with a pseudoephedrine–phosphotungstate ion pair complex. The influences of membrane composition, temperature, pH of the test solution, and the interfering ions on the electrode performance were investigated. The sensor exhibits a Nernstian response for pseudoephedrine hydrochloride ions over a relatively wide concentration range (1.0 × 10?1 to 1.0 × 10?5 mol L?1) with a slope of 56.2 ± 0.5 mV per decade at 25°C. It can be used in the pH range 4.0–10.5. The isothermal temperature coefficient of this electrode amounted to 0.0009 V/°C. The membrane sensor was successfully applied to determination of PSEHCl in its tablets and syrup.  相似文献   

6.
《Analytical letters》2012,45(2):298-311
Abstract

A polyvinyl chloride (PVC) based membrane sensor for terbium ions was prepared by employing Hematoporphyrin (HP) as an ionophore. The sensor revealed a very good selectivity (expect for the Fe3+ion) with respect to common alkali, alkaline earth and heavy metal ions. The plasticized membrane electrode exhibits a Nernstian response for Tb3+ ions over a wide concentration range (1.0 × 10?6 ? 1.0 × 10?2 M) with a slope of 19.8±0.3 mV per decade and low detection limit of 7.4 × 10?7 M. The developed sensor was used in determination of F? in mouth wash preparation sample.  相似文献   

7.
2,5-Dioxo-4-imidazolidinyl was used as an excellent sensing material in the preparation of a PVC membrane for a Ce(III)-selective sensor. The electrode shows a good selectivity for the Ce(III) ion with respect to most common cations including alkali, alkaline earth, transition, and heavy metal ions. The developed sensor exhibits a wide linear response with a slope of 19.6?±?0.3 mV per decade over the concentration range of 1.0?×?10?6 to 1.0?×?10?1 M, while the illustrated detection limit is 5.7?×?10?7 M of Ce(III) ions. Moreover, it is concluded that the sensor response is pH-independent in the range of 3.1–9.8. The applications of the recommended electrode include the determination of concentration of Ce(III) ions in soil and sediment samples, validation with CRM's, and the Ce(III) ion potentiometric titration with EDTA as an indicator electrode.  相似文献   

8.
《Electroanalysis》2004,16(12):1002-1008
Preliminary theoretical studies revealed the selective complexation of bis (2‐mercaptoanil) diacetyl (BMDA) with La3+ over several alkali, alkaline earth and heavy metal ions. Thus, novel PVC‐based membrane (PBM) and coated graphite membrane (CGM) sensors for La(III) based on BMDA were prepared. The electrodes display Nernstian behavior over wide concentration ranges (i.e., 1.0×10?5–1.0×10?1 M for PBM and 1.0×10?6–1.0×10?1 M for CGM). The potential response of sensors was pH independent in the range of 4.0–8.0. The sensors possess satisfactory reproducibility, fast response time (<15 s), and specially excellent discriminating ability for La3+ ions with respect to most of the cations. The membrane sensor was used as an indicator electrode in potentiometric titration of lanthanum ions with EDTA. The coated graphite membrane electrode was applied in determination of fluoride ions in mouth wash preparations.  相似文献   

9.
A new tin complex namely tetracyclohexyl tin(IV) (TCHT) was synthesized and used as the ion carrier for the construction of a highly selective salicylate sensor. This sensor shows a Nernstian response to salicylate ions over a very wide concentration (1.0 × 10?7–1.0 × 10?1 M) in a pH range of 5.5–10.5. The optimum selectivity and response could be obtained for a membrane incorporating 30% PVC, 61% BA, 3% of cationic additive (HTAB) and 6% of TCHT. The response time of the electrode is very short in the whole concentration range (15 s). The electrode also shows an excellent discriminating ability for salicylate ions with respect to the most common organic and inorganic anions including chloride, sulfate, nitrate, nitrite, cyanide, sulfite, iodide, thiocyanate, phosphate, acetate, oxalate, citrate, and tartarate ions. The detection limit of the proposed sensor is 8.0 × 10?8 M. The electrode was successfully used for determining the concentration of salicylate ion in synthetic serums.  相似文献   

10.
Plasticised membranes using 2-[{(2-hydroxyphenyl)imino}methyl]-phenol (L1) and 2-[{(3-hydroxyphenyl)imino}methyl]-phenol (L2), have been prepared and investigated as Cu2+ ion-selective sensors. Effect of various plasticisers, namely, dibutyl phthalate (DBP), dibutyl sebacate (DBS), benzyl acetate (BA), o-nitrophenyloctylether (o-NPOE) and anion excluders, oleic acid (OA) and sodium tetraphenylborate (NaTPB) was studied and improved performance was observed in several instances. Optimum performance was observed with membranes of (L1) having composition L1 : DBS : OA : PVC in the ratio of 6 : 54 : 10 : 30 (w/w, %). The sensor works satisfactorily in the concentration range 3.2 × 10?8–1.0 × 10?1 mol L?1 with a Nernstian slope of 29.5 ± 0.5 mV decade?1 of a cu2+ . The detection limit of the proposed sensor is 2.0 × 10?8 mol L?1 (1.27 ng mL?1). Wide pH range (3.0–8.5), fast response time (7 s), sufficient (up to 25% v/v) non-aqueous tolerance and adequate shelf life (3 months) indicate the utility of the proposed sensor. The potentiometric selectivity coefficients as determined by matched potential method indicate selective response for Cu2+ ions over various interfering ions, and therefore could be successfully used for the determination of copper in edible oils, tomato plant material and river water.  相似文献   

11.
Novel ligand 5,5?-((3-nitrophenyl)methylene)bis(2,6-diaminopyrimidin-4(3H)-one) (L) was synthesised and characterised. Preliminary studies on L have showed that it has more affinity towards the Ni2+ ion. Thus, the L was used as the electroactive material in the fabrication of poly(vinyl chloride) (PVC)-based membrane sensors such as coated graphite electrode (CGE) and coated pyrolytic graphite electrode (CPGE). Several polymeric membranes were fabricated by incorporating L as ionophore, NaTPB as anion excluders and BA, 1-CN, DBP, DOP and o-NPOE as solvent mediators and their effect on potentiometric response studied. Comparative electroanalytical studies performed on the CGE and CPGE depict that the CPGE with optimised membrane composition of L:PVC:o-NPOE:NaTPB in the ratio of 7:33:58:2 (w/w, mg) exhibited the best response in terms of wide working concentration range from 2.0 × 10?8 to 1.0 × 10?1 mol L?1, (3.64 µg L?1 –18.2 g L?1) lower detection limit of 8.1 × 109 mol L?1 (1.47 µg L?1) with Nernstian compliance of 29.4 ± 0.2 mV decade?1 of activity of Ni2+ ion in the pH range of 3.5–9.0. The sensor can work satisfactorily in water–acetonitrile and water–methanol mixtures. It can tolerate 30% acetonitrile and 20% methanol content in the mixtures. The sensor showed fast response time of 8 s and could be used successfully for a period of 4 months. The sensor reflects its utility in the quantification of Ni2+ ion in real samples and has been successfully employed as an indicator electrode in the potentiometric titration of Ni2+ ion with EDTA.  相似文献   

12.
《Analytical letters》2012,45(13):1958-1970
Abstract

The polyvinyl chloride (PVC) membrane containing 2-{2-(2-anilinocarbothioyl)hydrazino)-2-oxoacetyl}-N-phenyl-1-hydrazinecarbothioamide (AHC) as a suitable iophore exhibits a Nernstian response for Tb3+ ions over a wide concentration range (1.0 × 10?6 to 1.0 × 10?2 M) with a slope of 19.6 ± 0.3 mV per decade and a limit of detection of 6.8 × 10?7 M in the pH range 3.5–8.5. The proposed sensor revealed very good selectivities (expect for the Pr3+ and Ho3+ ions) for a wide variety of other metal ions. The practical utility of the electrodes has been demonstrated by its use for the determination of Tb3+ in different solutions.  相似文献   

13.
A polyvinyl chloride (PVC) membrane based Pr(III) selective electrode was constructed using 1,6,7,12‐tetramine‐2,5,8,11‐tetraoxo‐1(12),6(7)‐di(biphenyl)dodecane (TATODBDD) as a neutral carrier. The sensor exhibits a Nernstian response for Pr(III) ions, a wide concentration range of 3.9×10?7?1.0×10?1 mol/L with a detection limit of 5.0×10?8 mol/L and slope of 19.5 mV/decade. The developed sensor revealed relatively good selectivity and high sensitivity for Pr(III) ions over the other lanthanide ions. The potentiometric response of the sensor is independent in the pH range 2.9–9.5. The advantages of sensor are low resistance, very fast response time (<10 s) with good selectivity. This sensor can be used up to 6 weeks without any divergences in potential response.  相似文献   

14.
《Analytical letters》2012,45(13):2026-2040
Abstract

The potentiometric response characteristics of a new copper(II) ion-selective PVC membrane electrode based on erythromycin ethyl succinate (EES) as ionophore were investigated. The electrode exhibited a Nernstian response to Cu2+ ions over the activity range of 1.5 × 10?2 to 2.0 × 10?6 mol L?1 with a limit of detection of 6.3 × 10?7 mol L?1. Stable potentials were obtained in the pH range of 5.5–6.5. The potentiometric selectivity coefficients were calculated by using fixed interference method and revealed no important interferences except for Ag+. This electrode was successfully applied as an indicator electrode in determination of copper ions in real water samples.  相似文献   

15.
《Electroanalysis》2005,17(22):2032-2036
We found that bis(thiophenal) pyridine‐2,6‐diamine (BPD) can be used as an excellent ion carrier to prepare a gadolinium‐selective PVC‐based membrane sensor. The use of oleic acid (OA) and potassium tetrakis(p‐chlorophenyl borate)(KTKpClPB), as anionic additives, and dibutyl phthalate (DBP), acetophenone (AP) and nitrobenzene (NB), as plasticizing solvent mediators was investigated. The best performance was observed with a membrane having the composition of 30% PVC; 62% BA; 5% BPD; and 3% KTKpClPB. The resulting sensor works well over a relatively wide concentration range (1.0×10?6–1.0×10?1 M) with a Nernstian slope of 19.4±0.4 mV per decade of gadolinium activity over a wide pH range (3.5–8.0). The limit of detection of the sensor is 7.0×10?7 M (ca. 110 ng mL?1). The proposed electrode shows excellent discriminating ability toward gadolinium ions with regard to common alkali, alkaline earth, transition, heavy metal ions, and specially, lanthanide ions. The proposed sensor was applied as an indicator electrode for titration of gadolinium ions with EDTA.  相似文献   

16.
《Electroanalysis》2004,16(16):1330-1335
A poly(vinyl chloride) membrane sensor based on oxalic acid bis (cyclohexylidene hydrazide) as membrane carrier was prepared and investigated as a Cr(III)‐selective electrode. The electrode reveals a Nernstian behavior (slope 19.8±0.4 mV decade?1) over a wide Cr(III) ion concentration range 1.0×10?7–1.0×10?2 mol dm?3 with a very low limit of detection (i.e., down to 6.3×10?8 mol dm?3). The potentiometric response of the sensor is independent of the pH of the test solution in the pH range 1.7–6.5. The electrode possesses advantage of very fast response, relatively long lifetime and especially good selectivity to wide variety of other cations. The sensor was used as an indicator electrode, in the potentiometric titration of chromium ion and in the determination of Cr(III) in waste water and alloy samples.  相似文献   

17.
A PVC membrane electrode for copper(II) ions based on a recently synthesized naphthol-derivative Schiff’s base as membrane carrier was prepared. The sensor exhibits a Nernstian response for Cu2+ ions over a wide concentration range (5.0 × 10–6–5.0 × 10–2 mol/L) with a detection limit of 3.1 × 10–6 mol/L (0.2 μg/mL). It has a very short response time of about 5 s and can be used for ¶3 months without any divergence in potential. The proposed electrode revealed good selectivities over a wide variety of other cations including alkali, alkaline earth, transition and heavy metal ions and could be used in a pH range of 4.0–7.0. It was successfully applied to the direct determination and potentiometric titration of copper ion.  相似文献   

18.
《Electroanalysis》2005,17(20):1828-1834
A recently synthesized azao‐containing Schiff's base N,N′‐adipylbis(5‐phenylazo salicylaldehyde hydrazone) was used as a suitable neutral ion carrier in construction of a highly selective La3+‐PVC membrane electrode. The electrode exhibits a Nernstian response with a slope of 19.4 mV decade?1 over a wide concentration range (1.0×10?6–1.0×10?2 M) and a limit of detection of 4.0×10?7 M (0.05 ppm). The electrode possesses a fast response time of ca. 10 s and can be used for at least 3 months without observing any deviation. The proposed electrode revealed excellent selectivity for La3+ over a wide variety of alkali, alkaline earth, transition and heavy metal ions and could be used in a pH range of 4.0–8.0. The practical utility of the electrode has been demonstrated by its use as an indicator electrode in the potentiometric titration of La3+ ions with EDTA and in determination of F? ion in some pharmaceutical preparations.  相似文献   

19.
A PVC membrane electrode for Hg(II) ions, based on a new cone shaped calix[4]arene (L) as a suitable ionophore was constructed. The sensor exhibits a linear dynamic in the range of 1.0 × 10?6–1.0 × 10?1 M, with a Nernstian slope of 29.4 ± 0.4 mV decade?1, and a detection limit of 4.0 × 10?7 M. The response time is quick (less than 10 s), it can be used in the pH range of 1.5–4, and the electrode response and selectivity remained almost unchanged for about 2 months. The sensor revealed comparatively good selectivity with respect to most alkali, alkaline earth, and some transition and heavy metal ions. It was successfully employed as an indicator electrode in the potentiometric titration of Hg2+ ions with potassium iodide, and the direct determination of mercury content of amalgam alloy and water samples.  相似文献   

20.
A new poly(vinyl chloride)-based membrane was fabricated with the cobalt(II) complex of 2,4-dimethyl-1,5,8,11-tetraazacyclotrideca-1,4-diene [Me2(13)dieneN4] as an ion carrier. The membrane composition was Co2+ complex/PVC/NaTPB/DBP 15:50:15:20 (w/w). The sensor exhibited a Nernstian response for Co2+ ions over a wide concentration range (7.94×10−6–1.0×10−1 M) at pH 2.5–7.0, a response time of 10 s, and it could be used for 3 months without any significant divergence in potential. The proposed membrane sensor exhibited good selectivity for Co2+ over a wide variety of other metal ions and in mixtures containing up to 25% (v/v) non-aqueous content. The sensor was successfully used as an indicator electrode in the potentiometric titration of Co2+ with EDTA and the direct determination of Co2+ in real samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号