首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Commercially available polymer-based monolithic and perfusive stationary phases were evaluated for their applicability in chromatography of biologics. Information on bed geometry, including that from electron microscopy (EM), was used to interpret and predict accessible volumes, binding capacities, and pressure drops. For preparative purification of biologics up to at least 7 nm in diameter, monoliths and perfusive resins are inferior to conventional stationary phases due to their low binding capacities (20–30 g/L for BSA). For larger biologics, up to several hundred nanometers in diameter, calculations from EM images predict a potential increase in binding capacity to nearly 100 g/L. The accessible volume for adenovirus calculated from the EM images matched the experimental value. While the pores of perfusive resins are essentially inaccessible to adenovirus under binding conditions, under non-adsorbing conditions the accessible intrabead porosity is almost as large as the interbead porosity. Modeling of breakthrough curves showed that the experimentally observed slow approach to full saturation can be explained by the distribution of pore sizes.  相似文献   

2.
徐雪峰  郭志谋  梁鑫淼 《色谱》2012,30(11):1188-1193
研究了在反相高效液相色谱模式下,基于点击化学的β-环糊精手性固定相对苯并恶嗪类对映体的手性分离情况。考察了流动相中有机改性剂的类型和比例、缓冲盐的浓度和pH值对分离的影响。考察结果表明: 乙腈作为有机改性剂比甲醇更有利于苯并恶嗪对映体的分离;乙酸三乙胺缓冲盐体积分数从0.1%增大到1.0%时,苯并恶嗪对映体的保留时间和分离度都随之减小,在pH 4.1时苯并恶嗪对映体具有最大分离度。因此确定乙腈和体积分数为0.1%的乙酸三乙胺缓冲盐流动相(pH 4.1)为最佳分离条件。分离机理研究结果表明,固定相和样品之间的包容络合相互作用以及样品和固定相之间的氢键作用,是样品得以分离的基础。本研究为进一步深入研究β-环糊精固定相提供了实验基础,同时也证明了点击化学在手性环糊精固定相制备中具有极大潜力。  相似文献   

3.
Molecular simulations of water/acetonitrile and water/methanol mobile phases in contact with a C(18) stationary phase were carried out to examine the molecular-level effects of mobile phase composition on structure and retention in reversed-phase liquid chromatography. The simulations indicate that increases in the fraction of organic modifier increase the amount of solvent penetration into the stationary phase and that this intercalated solvent increases chain alignment. This effect is slightly more apparent for acetonitrile containing solvents. The retention mechanism of alkane solutes showed contributions from both partitioning and adsorption. Despite changes in chain structure and solvation, the molecular mechanism of retention for alkane solutes was not affected by solvent composition. The mechanism of retention for alcohol solutes was primarily adsorption at the interface between the mobile and stationary phase, but there were also contributions from interactions with surface silanols. The interaction between the solute and surface silanols become very important at high concentrations of acetonitrile.  相似文献   

4.
The solvation parameter model system constants and retention factors were used to interpret retention properties of 39 calibration compounds on a biphenylsiloxane-bonded stationary phase (Kinetex biphenyl) for acetone-water binary mobile phase systems containing 30–70% v/v. Variation in system constants, phase ratios, and retention factors of acetone-water binary mobile phases systems were compared with more commonly used acetonitrile and methanol mobile phase systems. Retention properties of acetone mobile phases on a Kinetex biphenyl column were more similar to that of acetonitrile than methanol mobile phases except with respect to selectivity equivalency. Importantly, selectivity differences arising between acetone and acetonitrile systems (the lower hydrogen-bond basicity of acetone-water mobile phases and differences in hydrogen-bond acidity, cavity formation and dispersion interactions) could be exploited in reversed-phase liquid chromatography method development on a Kinetex biphenyl stationary phase.  相似文献   

5.
We investigated the effects of the concentration of naphthalene sulphonic acids (NSAs) as anionic test compounds in the injected sample and of the salt additives to the mobile phase on ion-exclusion. The retention behaviour of NSAs sensitively reflects even minor changes in the ionic and hydrophobic interactions and can be useful for predicting the effects of the stationary phases in reversed-phase chromatography of polar and ionic compounds, both small ones and biopolymers, e.g., oligonucleotides. We studied chromatographic properties of several stationary phases intended for separations in aqueous mobile phases: a C18 column end-capped with polar hydrophilic groups, a densely bonded C8 column doubly end-capped with short alkyl groups, a short alkyl stationary phase designed to keep full pore accessibility in highly-aqueous mobile phases and a Bidentate column with “bridged” C18 groups attached to the silica hydride support. The chemistry and pore structure of various types of column packing materials and of the salt additives to the mobile phase affect the proportion of the pore volume non-accessible to anions due to ion-exclusion and consequently the peak asymmetry and hydrophobic selectivity in reversed-phase chromatography of organic acids. We also addressed the problems connected with the determination of column hold-up volume in aqueous mobile phases. The accessibility of the stationary phase for anionic compounds in contact with the sample zone is affected by ion-exclusion due to repulsive interactions with the negatively charged surface in the pores of the stationary phase. The accessible part of the stationary phase increases and consequently the migration velocity along the column decreases with increasing concentration of the sample in the zone moving along the column. Because of a limited access to the stationary phase, its capacity can be easily overloaded. The combination of the column overload and ion-exclusion effects may result in fronting or tailing peak asymmetry. To explain this behaviour, we proposed a modified Langmuir model, respecting the variation of the column capacity due to the effects of sample concentration on ion-exclusion.  相似文献   

6.
Analytical HPLC methods using derivatized cellulose and amylose chiral stationary phases used in normal and reversed-phase modes were developed for the diastereoisomeric separation of mononucleotide prodrugs (pronucleotides) of 3'-azido-2',3'-dideoxythymidine (AZT). The resolutions were performed with two silica-based celluloses using normal and reversed-phase methodologies: Tris-3,5-dimethylphenylcarbamate (Chiralcel OD-H and Chiracel OD-RH) and Tris-methylbenzoate (Chiralcel OJ and OJ-R). Two amyloses phases, Tris-3,5-dimethylphenylcarbamate (Chiralpak AD) and Tris-(S)-1-phenylethylcarbamate (Chiralpak AS), were used in normal-phase mode. Additionally, we developed separation using two stationary phases with immobilized cyclodextrins in reversed-phase and polar-organic modes. The mobile phase and the chiral stationary phase were varied to achieve the best resolution. Different types and concentration of aliphatic alcohols, acetonitrile or water in the mobile phase were also tested for the different separation modes. An optimal baseline separation (Rs > 1.5) was readily obtained with all silica-based celluloses and amyloses using a normal-phase methodology. The different columns gave complementary results in term of resolution. Limits of detection and quantification were 0.12-0.20 and 0.40-0.67 microm, respectively. This analytical method was applied in a preliminary study for the pronucleotide 2 quantification in cellular extract.  相似文献   

7.
Hydrophilic interaction chromatography (HILIC) is valuable alternative to reversed-phase liquid chromatography separations of polar, weakly acidic or basic samples. In principle, this separation mode can be characterized as normal-phase chromatography on polar columns in aqueous-organic mobile phases rich in organic solvents (usually acetonitrile). Highly organic HILIC mobile phases usually enhance ionization in the electrospray ion source of a mass spectrometer, in comparison to mobile phases with higher concentrations of water generally used in reversed-phase (RP) LC separations of polar or ionic compounds, which is another reason for increasing popularity of this technique. Various columns can be used in the HILIC mode for separations of peptides, proteins, oligosaccharides, drugs, metabolites and various natural compounds: bare silica gel, silica-based amino-, amido-, cyano-, carbamate-, diol-, polyol-, zwitterionic sulfobetaine, or poly(2-sulphoethyl aspartamide) and other polar stationary phases chemically bonded on silica gel support, but also ion exchangers or zwitterionic materials showing combined HILIC-ion interaction retention mechanism. Some stationary phases are designed to enhance the mixed-mode retention character. Many polar columns show some contributions of reversed phase (hydrophobic) separation mechanism, depending on the composition of the mobile phase, which can be tuned to suit specific separation problems. Because the separation selectivity in the HILIC mode is complementary to that in reversed-phase and other modes, combinations of the HILIC, RP and other systems are attractive for two-dimensional applications. This review deals with recent advances in the development of HILIC phase separation systems with special attention to the properties of stationary phases. The effects of the mobile phase, of sample structure and of temperature on separation are addressed, too.  相似文献   

8.
We investigated the mechanisms involved in the retention of various peptides on a stationary phase embedded with a quaternary ammonium group (BS C23), by high-performance liquid chromatography. This was compared with peptide retention on a conventional reversed-phase C18 (RP C18) column under isocratic conditions, to understand better the various mechanisms involved. Chromatographic characterization of the two stationary phases with “model” compounds showed that BS C23 is less hydrophobic than RP C18 and induces electrostatic interaction (attraction or repulsion) with ionized compounds. If reversed-phase partitioning was the predominant retention phenomenon, for both stationary phases, the retention mechanisms in BS C23 provided different selectivity to that of RP C18. Electrostatic attraction or repulsion was clearly observed between peptides and the permanent positively charged group embedded in BS C23 depending on the pH. For most of the peptides, a weak anion-exchange mechanism was observed on the quaternary ammonium-embedded stationary phase if mobile phases at neutral pH and low ionic strengths were employed.  相似文献   

9.
Summary We have determined the interaction behaviour of peptides with hydrophobic stationary phases on analytical columns using isnocratic or shallow gradient elution for the purpose of developing procedures for rapid optimization of conditions for preparative reversed-phase chromatography of peptides. From our investigation of the separation of two closely related decapeptides (differing by one methyl group), in a 1:1 molar ratio on an analytical C8 column, we have found that shallow gradients of 0.1% acetonitrile/min appeared to be the best compromise between resolution and a practical run time for preparative peptide separations. Up to 20mg of the two-peptide mixture was efficiently resolved on the analytical column, with >97% recovery of homogeneous peptides.  相似文献   

10.
11.
Summary Silica-bonded stationary phases were developed for the separation of nucleic acid constituents and their properties investigated with homologous oligoriboadenylic acids in electrostatic interaction chromatography and with alkylbenzenes in reversed-phase chromatography. Analysis of retention data confirmed the stratified molecular structure of the surface which consist of a layer of propyl chains anchoredvia siloxane bridges to the silica surface proper and of polar moieties attached to the hydrocarbonaceous functions. The polar top layer contains weak cationic and/or hydrophobic binding sites, is strongly hydrated in contact with aqueous eluents and bars the access by large biopolymers to the hydrocarbonaceous sublayer. In reversed-phase chromatography of small non polar molecules with hydro-organic eluents, however, this layer is accessible and engenders a retentive behavior typical for weak hydro-carbonaceous bonded phases. As a result the stationary phases, depending on the nature of the sample and the mobile phase, exhibit the properties of "soft" phases for the chromatography of biopolymers under mild elution conditions and those of "hard" phases for the separation of small non-polar molecules under conditions generally employed in reversed-phase chromatography. The retention of nucleic acid constituents on most of the stationary phases investigated subject to a dual mechanism as a result of the interplay of electrostatic and hydrophobic interactions between the eluites and the binding sites on the stationary phase surface. Siliceous stationary phases having surface morphology described above are suitable for the separation of nucleic acid constituents having widely ranging molecular weights up to 3 × 106 Daltons provided the support has appropriate pore dimensions. This is demonstrated by the separation of mixtures arising from digesting t-RNApha or polyadenylic acids as well as those of ribosomal RNA’s and different forms of the plasmid pBR322 DNA. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

12.
The thermodynamic retention behaviour of a linear series of polycyclic aromatic hydrocarbons (PAHs) was investigated on C18 and selected phenyl-type reversed-phase stationary phases, namely C18, C18 Aqua, Propyl-phenyl and Synergi polar-RP stationary phases, using methanol mobile phases. The Propyl-phenyl stationary phase, despite having the lowest surface coverage, was found to exhibit significantly larger enthalpic interactions to the other Phenyl-type phase (Synergi polar-RP) even though this had a much higher surface coverage. This indicated that stronger interactions between the PAHs and the stationary phase ligands were occurring on the Propyl-phenyl phase. Evaluation of the elution band profile of the PAHs in the aqueous methanol mobile phase revealed fairly symmetrical bands for the C18, C18 Aqua and Synergi polar-RP, but severe peak tailing on the Propyl-phenyl phase. A change in mobile phase from methanol to acetonitrile improved the peak shape of the PAHs on the Propyl-phenyl phase, leading to the assumption that unfavourable pi-pi interactions were occurring between the electron-rich PAHs and the electron-rich phenyl rings of the Propyl-phenyl phase.  相似文献   

13.
The retention of aromatic hydrocarbons with polar groups has been correlated as log k1 versus log k2 for reversed-phase high-performance liquid chromatography systems with different binary aqueous mobile phases containing methanol, acetonitrile or tetrahydrofuran as modifiers. Distinct changes in separation selectivity have been observed between tetrahydrofuran and acetonitrile or methanol systems. Methanol and acetonitrile systems show lower diversity of separation selectivity. The changes in retention and selectivity of aromatic hydrocarbons with various polar groups between any two chromatographic systems with binary aqueous eluents (tetrahydrofuran vs. acetonitrile, tetrahydrofuran vs. methanol and methanol vs. acetonitrile) have been interpreted in terms of molecular interactions of the solute with especially one component of the stationary phase region, i.e. extracted modifier, and stationary phase ordering. The ordering of the stationary phase region caused by modifier type influences the chromatographic selectivity of solutes with different molecular shape.  相似文献   

14.
A simple model is proposed that relates the parameters describing the peak width with the retention time, which can be easily predicted as a function of mobile phase composition. This allows the further prediction of peak shape with global errors below 5%, using a modified Gaussian model with a parabolic variance. The model is useful in the optimisation of chromatographic resolution to assess an eventual overlapping of close peaks. The dependence of peak shape with mobile phase composition was studied for mobile phases containing acetonitrile in the presence and absence of micellised surfactant (micellar-organic and hydro-organic reversed-phase liquid chromatography, RPLC). In micellar RPLC, both modifiers (surfactant and acetonitrile) were observed to decrease or improve the efficiencies in the same percentage, at least in the studied concentration ranges. The study also revealed that the problem of achieving smaller efficiencies in this chromatographic mode, compared to hydro-organic RPLC, is not only related to the presence of surfactant covering the stationary phase, but also to the smaller concentration of organic solvent in the mobile phase.  相似文献   

15.
Porous silica beads have been coated with a 2-hydroxy-3-methacryloyloxypropyl beta-cyclodextrin polymer by in situ free-radical polymerization in water. This system has been developed for use as a stationary phase in high-performance liquid chromatography. In the conditions used, the coating efficiency is controlled by the initial concentration of the monomer. The polymer coating has been quantitated by thermogravimetric analysis. The stationary phases have also been characterized by means of the nitrogen adsorption/desorption method, energy dispersion X-ray analysis, and scanning electron microscopy to investigate the changes in the porosity, as well as in the surface properties generated by the coating process. Finally, the chromatographic evaluation has been made under normal- and reversed-phase elution conditions.  相似文献   

16.
The effect of varying mobile phase composition across a ternary space between two binary compositions is examined, on four different reversed-phase stationary phases. Examined stationary phases included endcapped C8 and C18, as well as a phenyl phase and a C18 phase with an embedded polar group (EPG). Mobile phases consisting of 50% water and various fractions of methanol and acetonitrile were evaluated. Retention thermodynamics are assessed via use of the van’t Hoff relationship, and retention mechanism is characterized via LSER analysis, as mobile phase composition was varied from 50/50/0 water/methanol/acetonitrile to 50/0/50 water/methanol acetonitrile. As expected, as the fraction of acetonitrile increases in the mobile phase, retention decreases. In most cases, the driving force for this decrease in retention is a reduction of the enthalpic contribution to retention. The entropic contribution to retention actually increases with acetonitrile content, but not enough to overcome the reduction in the enthalpic contribution. In a similar fashion, as methanol is replaced with acetonitrile, the v, e, and a LSER system constants change to favor elution, while the s and c constants change to favor retention. The b system constant did not show a monotonic change with mobile phase composition. Overall changes in retention across the mobile phase composition range varied, based on the identity of the stationary phase and the composition of the mobile phase.  相似文献   

17.
The retention behavior of methoxy-substituted p-benzoquinones and the corresponding hydroquinones in reversed-phase chromatography was examined on octylsilica and two octadecylsilica stationary phases and with five hydroorganic mobile phases containing acetonitrile, methanol or tetrahydrofuran and additionally in most cases (NH3OH)3PO4 used as a reducing and buffering agent. The retention order of benzoquinones and hydroquinones was the same on each stationary phase with either methanol or acetonitrile as the organic modifier. On the other hand, minor differences in the retention order were observed with the various stationary phases. In all cases, satisfactory quantitative structure-retention relationships (QSRRs) were found and the data suggest that the differences in the retention behaviour of octadecylsilicas used in this study are silanophilic interactions which, together with solvophobic interaction contribute to the retention of these eluites. Further analysis showed that QSRRs of sterically crowded molecules must take into account reduced surface area available for binding. The retention data obtained with use of aqueous tetrahydrofuran as mobile phase failed to give rise to satisfactory QSRRs. This was attributed to selective solvation of eluite by tetrahydrofuran and/or nearly equipotent binding of eluite and tetrahydrofuran to stationary phase.  相似文献   

18.
K. Jinno 《Chromatographia》1982,15(11):723-725
Summary Utilization of micro-HPLC is described for the direct measurement of the partition coefficients needed in studying the quantitative structure — activity relationships (QSAR). The method involves analyzing the solutes in acetonitrile — water as the mobile phase on commercially available reversed-phase stationary phases.  相似文献   

19.
This work describes the use of mixed-mode stationary phases which exhibit both strong ion-exchange (either cation-exchange, SCX, or anion-exchange, SAX) and reversed-phase chromatographic characteristics in capillary electrochromatographic separations of pyrimidine derivatives. Different packing materials, namely C6, SCX/C6 and SAX/C6, were compared and the influence of the composition of the carrier electrolyte (concentration of acetonitrile and pH) on the retention behavior of the selected solutes was investigated. A separation of all eight pyrimidine derivatives could be obtained on a 6.5 cm column packed with the SAX/C6 stationary phase in less than 3 min, with good peak shapes and efficiencies in the range 39,000 to 81,000 plates per meter.  相似文献   

20.
The retention behavior of a set of polar peptides separated on a silica hydride stationary phase was examined with a capillary HPLC system coupled to ESI‐MS detection. The mobile phases consisted of formic acid or acetic acid/acetonitrile/water mixtures with the acetonitrile content ranging from 5 to 80% v/v. The effects on peptide retention of these two acidic buffer additives and their concentrations in the mobile phase were systematically investigated. Strong retention of the peptides on the silica hydride phase was observed with relatively high‐organic low‐aqueous mobile phases (i.e. under aqueous normal‐phase conditions). However, when low concentrations of acetic acid were employed as the buffer additive, strong retention of the peptides was also observed even when high aqueous content mobile phases were employed. This unique feature of the stationary phase therefore provides an opportunity for chromatographic analysis of polar peptides with water‐rich eluents, a feature usually not feasible with traditional RP sorbents, and thus under conditions more compatible with analytical green chemistry criteria. In addition, both isocratic and gradient elution procedures can be employed to optimize peptide separations with excellent reproducibility and resolution under these high aqueous mobile phase conditions with this silica hydride stationary phase.  相似文献   