首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
《Electrophoresis》2018,39(2):311-325
Over the last decade, capillary electrophoresis gained tremendous importance, because it became an indispensible tool for the quality control of biologics, e.g. therapeutic antibodies. Consequently, there has been a continuous development within the CE market. Microchip techniques have been established in the last years. Further trends are complete solutions for specific applications by the usage of reagent kits. Step by step instructions and facilitated handling of the instruments are becoming more common. This work focuses on the sized‐based protein analysis with CE‐SDS. The instruments CE 7100 by Agilent Technologies, LabChip® GXII Touch HT by PerkinElmer, Maurice S. by Protein Simple and PrinCE NextI870 by Prince Technologies have been evaluated, mainly analyzing protein mixtures of different molecular weights in long series. Published data of the PA 800 plus by SCIEX are also included in the tabled results. Precision, reliability, flexibility, and speed have been identified as the most important performance parameters, others such as resolution, sensitivity, linearity, ease of use and sustainability have also been considered. All tested instruments have shown an excellent performance. Depending on application and necessities, each user can find the most appropriate one.  相似文献   

2.
A novel high performance system to control the temperature of the microcartridge in on-line solid phase extraction capillary electrophoresis (SPE–CE) is introduced. The mini-device consists in a thermostatic bath that fits inside of the cassette of any commercial CE instrument, while its temperature is controlled from an external circuit of liquid connecting three different water baths. The circuits are controlled from a switchboard connected to an array of electrovalves that allow to rapidly alternate the water circulation through the mini-thermostatic-bath between temperatures from 5 to 90 °C. The combination of the mini-device and the forced-air thermostatization system of the commercial CE instrument allows to optimize independently the temperature of the sample loading, the clean-up, the analyte elution and the electrophoretic separation steps.  相似文献   

3.
《Analytical letters》2012,45(11):2345-2357
Abstract

Method validation is one of the most important requirements of capillary electrophoretic (CE) methodologies. In spite of the advanced CE equipment available, this technique is still suffering with the problem of reproducibility due to certain nonconstant operational parameters. This article discusses the factors and reasons for nonreproducibility in CE methodologies, which include buffers, capillary, modes of injections, and applied voltage. Suggestions have also been presented to achieve maximum reproducibility in capillary electrophoresis experiments.  相似文献   

4.
《Electrophoresis》2017,38(16):2069-2074
The interinstrumental transfer of a short‐end CE method was studied. A model separation of the hexameric forms of niobium, tantalum, and their substituted ions (Nb6−xTax with 0 ≤ x  ≤ 6) was selected as test case. The method was first optimized on a Beckman instrument and in a second step transferred to an Agilent instrument. The transfer needed updated guidelines that tackled differences in effective capillary length, 8.5 (Agilent) versus 10 cm (Beckman), because of instrumental different capillary cartridges. Differences in effective length lead to migration time and separation efficiency inequalities, illustrated by a decrease in resolution between the substituted ions. The difference in effective length was overcome by adapting the lift offset parameter of the Agilent instrument. The lift offset default setting is 4 mm and by increasing this parameter both the inlet and outlet lifts are lowered and thus the detection window can be displaced and consequently the effective length was increased. The decrease in effective length difference and the effect on the separation efficiency was investigated and led finally to a restored separation of the substituted ions. The adaptation of the lift offset parameter during short‐end injection methods was added to earlier developed guidelines to facilitate interinstrumental method transfer of CE methods.  相似文献   

5.
Capillary Electrophoresis-Sodium Dodecyl Sulfate (CE-SDS) method with UV detection was developed and satisfactorily used for determination of purity and manufacturing consistency of a monoclonal antibody (MAb) at Amgen Inc. (Seattle, WA). When this method was applied to some other MAbs, several problems with method robustness became apparent. These issues resulted in abnormal Electropherogram (e-gram) profiles potentially linked to various parameters specific molecules analyzed, sample formulation buffer composition, CE-SDS gel matrix type, and operators. A multi-users interest group (called CE Users Forum) was formed to systematically investigate and understand these issues. The CE Users Forum first identified the issues which needed resolution, defined group experiments to better understand the problem and to test potential solutions, and together defined a generic (platform) CE-SDS method for MAbs. Two CE instruments, Agilent HP3DCE and Beckman PA 800, two CE-SDS gel matrices, BioRad and Beckman gels, as well as different types of MAbs in various buffers were used in this investigation. We present here a platform CE-SDS method for purity determination of MAbs. Method optimization and trouble-shooting procedures by the CE Users Forum played a key role in delivering a robust analytical method for characterization of antibodies by improving instrumental and experimental parameters such as instrument variability, instrument operating parameters, operator training, and reagent stability. The optimized CE-SDS method is used during process development and has been transferred to the quality control (QC) lab as a purity assay for lot release testing of therapeutic antibodies. Any trained analyst can successfully perform this method. A group such as the CE Users Forum is a good way to integrate best practices and solve technical issues in a cooperative environment.Presented at: CE in the Biotechnology & Pharmaceutical Industries: 7th Symposium on the Practical Applications for the Analysis of Proteins, Nucleotides and Small Molecules, Montreal, Canada, August 12–16, 2005  相似文献   

6.
A simple interface has been developed to couple capillary electrophoresis (CE) to inductively coupled plasma atomic emission spectrometry (ICP-AES) for metal speciation. A concentric glass nebulizer with elongated tip is used as the CE-ICP interface. The CE capillary is the central tube of the nebulizer. A platinum wire is wrapped across the exit end of the CE capillary to provide electrical connection to the CE power supply. No sheath flow of buffer solution is needed. A simple cooling system has also been developed. A peristaltic pump circulates water through a plastic tube that encloses the section of the CE capillary between the CE instrument and the ICP spectrometer. Characteristics of the CE-ICP interface, e.g., elution time, nebulization and transport efficiency and peak broadening, versus carrier gas flow-rate have been studied. Comparisons to a previous design with the Pt electrode inserted into the end of the CE capillary are made where appropriate. The reproducibility (RSD) in ICP emission intensity of the system is <4%. Detection limits of Cr and Cu are approximately 5 ng/ml.  相似文献   

7.
Denaturing CE (DCE) is a powerful tool for analysis of DNA variation. The development of commercial multi-CE instruments allows large-scale studies of DNA variation (many samples and many fragments). However, the cost of consumables like capillary arrays and sieving matrix might limit the use of DCE in such studies. Thus, we have tested 72 different in-house formulated sieving matrices' ability to suppress EOF and separate PCR-amplified alleles with the DCE variant, cycling temperature CE (CTCE). The data herein demonstrate that alleles can be baseline-separated by use of PVP and poly(N,N-dimethyl acrylamide) polymers at various percentages and pH. Allele separation by CTCE is matrix-independent and consequently applicable to any capillary instrument used for DNA separation. Formulation of sieving matrix for CTCE was done by dissolving appropriate amount of polymer powder into the running buffers. Allele separation was observed at different pH (7.5-8.5), concentrations and molecular size of the polymer, without compromising the separation and reproducibility. Finally, the cost reduction of homemade matrices is more than 1000-fold as compared to commercial sieving matrices.  相似文献   

8.
Swelling of the polyimide coating of fused-silica capillaries in acetonitrile-containing buffers was found to be the reason for several problems in capillary electrophoresis (CE) and capillary electrochromatography (CEC). Scanning electron microscopy photographs of the ends of raw fused-silica tubing showed that the coating becomes soft and increases its volume after longer contact with such buffers. As a consequence, separation efficiency can deteriorate, the capillary ends can clog or break off. To prevent swelling of the polyimide coating, fused-silica capillaries used in CE or CEC were heated at 300 degrees C for a longer period of time which improved their long-term stability in comparison to raw fused-silica tubing.  相似文献   

9.
This paper describes a long-range remotely controlled CE system built on an all-terrain vehicle. A four-stroke engine and a set of 12-V batteries were used to provide power to a series of subsystems that include drivers, communication, computers, and a capillary electrophoresis module. This dedicated instrument allows air sampling using a polypropylene porous tube, coupled to a flow system that transports the sample to the inlet of a fused-silica capillary. A hybrid approach was used for the construction of the analytical subsystem combining a conventional fused-silica capillary (used for separation) and a laser machined microfluidic block, made of PMMA. A solid-state cooling approach was also integrated in the CE module to enable controlling the temperature and therefore increasing the useful range of the robot. Although ultimately intended for detection of chemical warfare agents, the proposed system was used to analyze a series of volatile organic acids. As such, the system allowed the separation and detection of formic, acetic, and propionic acids with signal-to-noise ratios of 414, 150, and 115, respectively, after sampling by only 30 s and performing an electrokinetic injection during 2.0 s at 1.0 kV.  相似文献   

10.
Electrospray ionization performs best with volatile buffers. However, generally the best separation performance for capillary electrophoresis (CE) is achieved with non‐volatile buffers. Hyphenation of CE with mass spectrometry (MS) utilizing atmospheric pressure photoionization (APPI) enables use of a wider range of separation buffers without compromising detection sensitivity. As APPI is considered to be mass flow sensitive, the use of a larger inner diameter separation capillary (75 µm) allows larger volumes to be injected, without decreased separation performance, thus providing improved sensitivity (approx. a factor of 10), compared to the use of a 25 µm capillary. However, nebulizing gas flow and position of capillary tip in the sprayer have to be carefully optimized to prevent excessive band broadening. Further improvement in sensitivity (approx. a factor of 2) was obtained by decreasing the distance between the sprayer and ionization region, indicating that a specially designed CE/APPI‐MS interface for low flow rates will be favourable. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
A multiplexed capillary electrophoresis (CE) system equipped with 96 channels was evaluated for high-throughput screening in drug discovery by microemulsion electrokinetic chromatography (MEEKC). Method transfer from a single channel to a multichannel CE system is described. Loss of efficiency and reduced migration times could be elucidated to the poor efficacy in Joule heat dissipation by forced air cooling in the multiarray system compared to liquid cooling in the single channel instrument. On the other hand, only 48 channels could actually be used because of the maximum total current of 3 mA. Precision data remained below 8% and 9% for migration times and peak areas, respectively. Some UV-detector cross-talk interference between neighboring capillary channels was noted. Impurities at 0.5% compared to the main peak (100%) could be detected with the multiplexed system which is 10 times lower compared to the single capillary system. Higher efficiency and improved figures of merit (absolute sensitivity and no cross-talk interferences) were obtained by using an array of only 24 capillaries.  相似文献   

12.
Shi Q  Chen J  Li X  Cao W  Zheng L  Zang J  Wang X 《色谱》2011,29(6):481-487
对毛细管电泳法分离15种核苷类化合物所用的不同缓冲液体系进行了系统比较,确定不同模式毛细管电泳法分析多种核苷类化合物的最适合背景缓冲液体系(BGE)。分别以四硼酸钠、磷酸氢二钠、乙酸钠、碳酸氢钠、乙酸铵和乙二胺(DEA)为背景电解质,对毛细管区带电泳(CZE)、毛细管电泳-电喷雾飞行时间质谱(CE-ESI-TOF/MS)以及胶束电动毛细管电泳(MEKC)3种模式进行比较,并对其中几种优势缓冲体系进行了优化。结果表明,CZE模式下使用四硼酸钠和磷酸氢二钠缓冲体系无法同时分离15种核苷类化合物,因此只适用于分析核苷类化合物数量较少的样品。而使用含有2%丙酮的300 mmol/L DEA能完全分开15种核苷类化合物,且分辨率和峰形良好。MEKC模式下,以25 mmol/L磷酸氢二钠(添加70 mmol/L十二烷基磺酸钠(SDS))为缓冲盐的分离结果最佳,并且此方法能成功应用于海洋生物海葵中核苷类化合物的分离。CE-ESI-TOF/MS分析中,以20 mmol/L乙酸铵(pH 10.0)为背景电解质,正离子模式检测,15种核苷类化合物的质谱信号均良好,检测灵敏度明显优于文献中报道的使用DEA缓冲体系的结果。本研究阐明了不同缓冲体系对15种核苷类化合物分离的适用性,为毛细管电泳技术在复杂基质中多种核苷类化合物的分离方法中的应用奠定了基础。  相似文献   

13.
We developed a method for the analysis of multiplexed double-stranded DNA (dsDNA) samples complexed to various intercalating dyes using entangled polymer solution. A commercial single-column capillary electrophoresis (CE) instrument with diode array detection was used for multiplexed detection of DNA samples by addition of intercalating fluorescent molecules. A Phi X174HinfI and a pGEM DNA ladder (1 mg/mL) were used for the electrophoretic separation of dsDNA fragments ranging in size from 24 to 726 and 36 to 2645 bp, respectively. The results suggested that simultaneous electrophoretic separation of different DNA ladders multiplexed with different dyes could be performed in the same capillary yielding fast DNA sizing separations. CE analysis, which is often overpowered by slab gel in sample throughput, could now overcome this disadvantage by allowing multiplexed sample analysis in a fraction of the time needed for slab gel analysis. The separation efficiency of stained DNA molecules with both dyes were dramatically improved with buffers containing a large cation such as tetrapentylammonium ion (Npe(4) (+)) as the only cation in the buffer.  相似文献   

14.
The capillary electrophoretic separation of six water-soluble vitamins (thiamine, nicotinic acid, nicotinamide, d-pantothenic acid, pyridoxine and ascorbic acid) was studied. Four CE backgrounds electrolytes were optimized and the most suitable ones were applied for investigation of analytes in real samples (yeast, beer, syrups). Several extraction procedures were performed in order to extract vitamins from proteins and phosphate groups. The research showed that it is possible to minimize interference from the solution with a complex composition and overcome the problem of peak overlapping by exchanging separation BGEs. Moreover, the second order data generated by CE-DAD instrument and Chemstation software (Agilents Technologies) were used to check of the peak purity.  相似文献   

15.
The effect of the electrospray ionization (ESI) needle voltage on the electroosmotic flow (EOF) in capillary electrophoresis (CE)-mass spectrometry (MS) was investigated. The radial electric field that penetrates across the CE capillary wall imposed by the ESI needle voltage modifies the typical EOF. This effect was investigated for buffers commonly used in CE-MS. Variations as high as ±30% were observed.  相似文献   

16.
Securidaca inappendiculata Hassk. is a traditional Chinese herbal medicine. Pharma- cological investigations have shown that the xanthones, as main components accumulated in S. inappendiculata have many bioactivities, such as monoamine oxidase inhibition, antitumor activity, cytotoxicity, antibacterial activity, antifungal activity, anti-inflammatory properties, antioxidant activity and tuberculoatatic activity, etc1. The contents of xanthones are very important and key factors for quality …  相似文献   

17.
A decade of capillary electrophoresis   总被引:2,自引:0,他引:2  
Issaq HJ 《Electrophoresis》2000,21(10):1921-1939
Since the introduction of the first commercial capillary electrophoresis (CE) instrument a decade ago, CE applications have become widespread. Today, CE is a versatile analytical technique which is successfully used for the separation of small ions, neutral molecules, and large biomolecules and for the study of physicochemical parameters. It is being utilized in widely different fields, such as analytical chemistry, forensic chemistry, clinical chemistry, organic chemistry, natural products, pharmaceutical industry, chiral separations, molecular biology, and others. It is not only used as a separation technique but to answer physicochemical questions. In this review, we will discuss different modes of CE such as capillary zone electrophoresis, micellar electrokinetic chromatography, capillary gel electrophoresis, capillary isoelectric focusing, and capillary electrochromatography, and will comment on the future direction of CE, including array capillary electrophoresis and array microchip separations.  相似文献   

18.
To facilitate the implementation of affinity capillary electrophoresis into routine binding screening studies of proteins with metal ions, method acceleration, transfer and precision improvement were investigated. Affinity capillary electrophoresis was accelerated by using shorter capillaries, employing lower sample concentrations and smaller injection volumes. Intra‐ and inter‐instrument method transfers were investigated considering the temperature setting of the capillary cooling system. For intra‐instrument method transfer, similar results were obtained when transferring a method from a long (62 cm) to a short (31 cm) capillary. The analysis time was reduced from 9 to 4 min. In case of inter‐instrument method transfer, interaction results showed small variation on the capillary electrophoresis instrument with inefficient capillary cooling system. Binding measurement precision was enhanced by slightly pushing the sample above the beginning of the capillary. Changing the buffer vials after each 30 runs and employing extra flushing after each 60 subsequent runs further enhanced the precision. The use of 0.1 molar ethylenediaminetetraacetic acid in the rinsing solution successfully desorbs the remaining metal ions from the capillary wall. Excellent precision for apparent mobility ratio measurements was achieved for different protein–metal ion interactions (relative standard deviation of 0.16–0.89%, 15 series, 12 runs for each).  相似文献   

19.
Guihen E  Glennon JD  Cullinane M  O'Gara F 《Electrophoresis》2004,25(10-11):1536-1542
A rapid capillary electrophoretic (CE) method was developed for the determination of phloroglucinol compounds, monoacetylphloroglucinol (MAPG) and 2,4-diacetylphloroglucinol (DAPG), in microbial supernatants of Pseudomonas fluorescens F113 over a 24-h growth cycle. Prior to electrophoretic separation, solid-phase extraction of supernatant samples on octadecylsilica for the purpose of sample cleanup is recommended. The optimum electrophoretic conditions were found to be 25 mM sodium tetraborate running buffer at pH 9.3, temperature at 25 degrees C with an applied voltage of 25 kV. The capillary was an Agilent fused-silica capillary of total length 33 cm x 50 microm inner diameter, 375 microm outer diameter, with effective length 24.5 cm. While MAPG and DAPG were monitored at selected wavelengths in the range of 214-320 nm, analysis at 214 nm was used and a CE separation time of less than 2 min was achieved. A partial method validation study was performed in accordance with European Agency for Evaluation of Medicinal Products (EMEA) guidelines. The method displayed linearity over the investigated range of 10-200 microg/mL, with limits of detection of 1.2 microg/mL for MAPG and 1.3 microg/mL for DAPG.  相似文献   

20.
When optimizing a capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS) system, consideration has to be given not only to the separation but also to the electrospray stability. Methods developed for CE/UV analysis of drugs and peptides were considered and modified to be suitable for a CE/MS system with a robust sheathless interface. Different concentrations of the organic modifiers acetonitrile, methanol and 2-propanol were used in the separation buffer. The type and concentrations of these modifiers were also compared with reference to electrospray stability, sensitivity and time of analysis. In addition, different ionic strengths in the buffers were evaluated with reference to electrospray stability. The repeatability was used for the estimation of electrospray stability. The degree to which these parameters influenced the separation and the ESI stability was studied using a nine-peptide standard mixture and the antibiotic drugs bacampicillin and ampicillin as test substances. The analysis time and resolution were used as measures of the efficiency of the separation. A time-of-flight MS analyzer was used since it has the potential advantages of becoming a better fit for integration of CE with MS owing to the speed and sensitivity of this mass analyzer. The detection limit, i.e. 1 microM, for bacampicillin was comparable to what could be achieved with CE/MS on a quadrupole instrument using selected ion monitoring and sheath flow ESI.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号