首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 733 毫秒
1.
Shimura K 《Electrophoresis》2002,23(22-23):3847-3857
The methodological developments in the field of capillary isoelectric focusing (CIEF) published between 1997-2001 are reviewed as a continuation of the previous review by Rodriguez-Diaz et al. (Electrophoresis 1997, 18, 2134-2144). The applications are summarized and the progress in CIEF technologies, including experimental setup with coated and uncoated capillaries, remedies for the presence of salts in samples, additives to reduce precipitation of samples during the focusing process, calibration of the pH gradients, issues of reproducibility, carrier ampholyte-free CIEF, and a computer simulation of focusing process are discussed. Developments of IEF separations in fabricated microchannels and the advances in detection schemes, i.e., imaging, fluorescence and chemiluminescence, are summarized. The progress in micropreparation was noted, and the massive works for two-dimensional separations are described for the coupling with size-exclusion chromatography and mass spectrometry, in which the developments aimed at proteomics are discussed separately. The applications for the detection of noncovalent complexes and the separations of microorganisms are reviewed.  相似文献   

2.
Miniaturized capillary isoelectric focusing in plastic microfluidic devices   总被引:1,自引:0,他引:1  
Tan W  Fan ZH  Qiu CX  Ricco AJ  Gibbons I 《Electrophoresis》2002,23(20):3638-3645
We report the demonstration of miniaturized capillary isoelectric focusing (CIEF) in plastic microfluidic devices. Conventional CIEF technique was adapted to the microfluidic devices to separate proteins and to detect protein-protein interactions. Both acidic and basic proteins with isoelectric points (pI) ranging from 5.4 to 11.0 were rapidly focused, mobilized, and detected in a 1.2 cm long channel (50 microm deep x 120 microm wide) with a total analysis time of 150 s. In a device with a focusing distance of 4.7 cm, the separation efficiency for a basic protein, lysozyme, was achieved as high as 1.5 x 10(5) plates, corresponding to 3.2 million plates per meter. We also experimentally confirmed that IEF resolution is essentially independent of focusing length when the applied voltage is kept the same and within a range that it does not cause Joule heating. Further, we demonstrated the use of miniaturized CIEF to study the interactions between two pairs of proteins, immunoglobulin G (IgG) with protein G and anti-six histidine (anti-6xHis) with 6xHis-tagged green fluorescent protein (GFP). Using this approach, protein-protein interactions can be detected for as little as 50 fmol of protein. We believe miniaturized CIEF is useful for studying protein-protein interactions when there is a difference in pI between a protein-protein complex and its constitutent proteins.  相似文献   

3.
毛细管等电聚焦方法及其应用   总被引:1,自引:0,他引:1  
刘晓达  王全立  马立人 《色谱》1997,15(5):400-404
讨论了毛细管等电聚焦中所涉及的问题,如分离机理、电渗、迁移方法、检测器及其应用。由于毛细管等电聚焦操作方式的多样性,使其可适用于不同的仪器条件。非交联丙烯酰胺涂层能很好地消除电渗和蛋白吸附;而采用未处理的毛细管时,动态涂敷纤维素类亲水聚合物对碱性和中性蛋白亦能取得较好的分离效果。电荷耦合器件成像检测器尚待进一步发展才能成为常用的检测工具。对于复杂样品来说,仍需解决的问题是保证在较宽的pH范围内pI的线性。  相似文献   

4.
X Z Wu  S K Sze  J Pawliszyn 《Electrophoresis》2001,22(18):3968-3971
Miniaturization of whole-column imaging capillary isoelectric focusing (CIEF) is discussed. A 1.2 cm capillary was used as a separation column for CIEF. The experimental results for the analysis of two pI markers and the protein myoglobin showed that good CIEF separation results could be obtained. Secondly, a light-emitting diode (LED) was used as the light source for the whole-column absorbance imaging detection. The focusing of both the pI markers and myoglobin were observed with the LED light source. The whole-column imaging CIEF instrument was simplified and miniaturized by the use of the LED. Further developments are also discussed.  相似文献   

5.
Jin Y  Luo G  Oka T  Manabe T 《Electrophoresis》2002,23(19):3385-3391
Synthetic UV-detectable peptide pI markers were used to estimate isoelectric point (pI) values of proteins separated by capillary isoelectric focusing (CIEF) followed by cathodic mobilization in the absence of denaturing agents. The pI calculation and quantitative analysis of purified proteins showed the feasibility of these peptides as pI markers and internal standards in CIEF separation of proteins. Estimation of pI values of major proteins in human plasma was performed using the peptide pI markers, and the values were compared with those previously obtained by gel isoelectric focusing (IEF). Sera of immunoglobulin G (IgG) myeloma patients, which showed characteristic peaks of myeloma IgG in their CIEF patterns, were also subjected to the analysis and the pI values of the myeloma proteins have been estimated.  相似文献   

6.
We prepared a series of low-molecular-mass fluorescent ampholytes with narrow pI range. These fluorescein-based ampholytes are detection compatible with argon laser-induced fluorescence (LIF) detection. The selected properties, important for their routine use as fluorescent pI markers, were examined. The pI values of new fluorescein-based pI markers were determined by capillary isoelectric focusing (CIEF) using currently available low-molecular-mass pI markers for CIEF with photometric detection. The examples of CIEF with fluorometric detection of new compounds together with fluorescein isothiocyanate (FITC) derivatized proteins are presented.  相似文献   

7.
Affinity probe capillary isoelectric focusing (CIEF) with laser-induced fluorescence was explored for detection of Ras-like G proteins. In the assay, a fluorescent BODIPY FL GTP analogue (BGTPgammaS) and G protein were incubated resulting in formation of BGTPgammaS-G protein complex. Excess BGTPgammaS was separated from BGTPgammaS-G protein complex by CIEF using a 3-10 pH gradient and detected in whole-column imaging mode. In other cases, a single point detector was used to detect zones during the focusing step of CIEF using a 2.5-5 pH gradient. In this case, analyte peaks passed the detector in approximately 5 min at an electric field of 350 V/cm. Detection during focusing allowed for more reproducible assays at shorter times but with a sacrifice in sensitivity compared to detection during mobilization. Resolution was adequate to separate BGTPgammaS-Ras and BGTPgammaS-Rab3A complexes. Formation of specific complexes was confirmed by adding GTPgammaS to samples containing BGTPgammaS-G protein. GTPgammaS competed with BGTPgammaS for G protein binding sites resulting in decreased BGTPgammaS-G protein peak heights. The concentrating effect of CIEF enabled detection limits of 30 pM.  相似文献   

8.
综述了毛细管电泳与电喷雾质谱联用的接口技术、分离模式及其在蛋白质分析领域中的应用,特别是毛细管等电聚焦与电喷雾质谱联用在蛋白质组学中研究进展。  相似文献   

9.
Sixteen peptides (trimers to hexamers) were designed for use as a set of pI markers for capillary isoelectric focusing (CIEF). Each peptide contains one tryptophan residue for detection by UV absorption and other amino acid residues having ionic side chains, which are responsible for focusing to its pI. The pIs of these peptides were determined by slab-gel IEF using commercial carrier ampholytes. The focused peptides in the gel were detected by absorption measurement at 280 nm using a scanning densitometer and the pH gradient was determined by measuring the pH of the gel using an oxidized metal membrane electrode. The pI values of the peptides ranged from 3.38 to 10.17. The obtained values agreed well with the predicted ones, which were calculated based on amino acid compositions, with root mean square differences of 0.15 pH unit. The peptides were detected at 280 nm as very sharp peaks when separated by CIEF. The pI values of some standard proteins were redetermined by CIEF by using this set of peptide pI markers and the values agreed closely with those reported previously. The sharp focusing, stability, high purity and high solubility of these synthetic pI markers should facilitate the profiling of a pH gradient in a capillary and the determination of the pI values of proteins.  相似文献   

10.
Mok ML  Hua L  Phua JB  Wee MK  Sze NS 《The Analyst》2004,129(2):109-110
Capillary isoelectric focusing (CIEF) was performed in pseudo-closed channel to separate proteins on a plastic chip. Pseudo-closed channel provided a novel way to couple protein separation by CIEF to MALDI mass spectrometry without eluting the focused proteins.  相似文献   

11.
Conditions of capillary isoelectric focusing (CIEF) to separate human cerebrospinal fluid (CSF) proteins were examined referring to those which we have established for the separation of human plasma/serum proteins. Since the average protein concentration in CSF is about 1/200 of plasma and the salt concentration is at almost the same level as plasma, desalting of CSF samples with minimum dilution was a prerequisite for CIEF analysis of CSF proteins. We constructed an apparatus to dialyze CSF at the level of 20-30 microL, this volume being sufficient for 3-4 repeated analyses of the CSF sample. To trace the process of dialysis, a simple device to measure the conductivity of the dialyzate was also constructed. Most of the CIEF conditions for plasma protein analysis could be applied for CSF protein analysis. However, the addition of N,N,N',N'-tetramethylethylenediamine (TEMED) at a suitable concentration was necessary to improve the resolution of basic proteins (IgG region), since some CSF patterns showed peaks of basic proteins which are not obvious in the serum of the same patient. About 70 peaks and shoulders of CSF proteins could be detected by the established CIEF technique. The results of CIEF analysis of CSF samples suggested that the technique will be useful as a survey method to detect specific proteins in CSF, which might relate to disorders in the central nervous system.  相似文献   

12.
蛋白质组学对其分析技术提出了大规模、高通量的要求 [1] .传统的等电聚焦 ( p I) -分子量 ( MW)双向电泳技术 ( 2 D- Gel)尽管在蛋白质组学研究中占有重要地位 ,但其操作繁杂、工作周期长 .Pandey等[1] 将毛细管等电聚焦 ( CIEF)与电喷雾质谱 ( ESIMS)联用 ,使得 p I和 MW两维分离鉴定技术变得简单迅速 .但 CIEF- MS的接口操作需中断高压和将毛细管阴极端插入电喷雾管 ,故引起分析蛋白质的散焦和不重现 .本工作改进了 CIEF- MS接口 ,采用毛细管阴极端和电喷雾针一体化的电喷雾接口 ,无需中断高压 ,实现了 CIEF- MS的在线联…  相似文献   

13.
Clinical assays for the primary evaluation of congenital hemoglobin (Hb) disorders must detect and identify a variety of Hb variants. We analyzed hemolysates containing Hb variants with similar charge to evaluate the diagnostic sensitivity and specificity of automated capillary isoelectric focusing (CIEF). Peak separation was observed for each variant in samples containing Hb S, D, and G. The calculated isoelectric points (pI) of these variants were significantly different such that each could be identified in a single run with pI as the sole criterion of identification. The pI of Hb C was significantly different from that of Hb E, C-Harlem, and O-Arab. Hb E, C-Harlem, and O-Arab had similar pI and were not readily differentiated. Hb Koln, M-Saskatoon, Aida, and S/Aida hybrid were readily separated from common Hb variants and detected by CIEF. We conclude that CIEF exhibits both diagnostic sensitivity and specificity, and that pI is an objective and specific criterion of Hb variant identification.  相似文献   

14.
When electrospray ionisation mass spectrometry (ESI-MS) is used on-line with capillary isoelectric focusing (CIEF), the presence of the carrier ampholytes creating the IEF pH gradient is not desirable. With the purpose of removing these ampholytes, we have developed a free-flow electrophoresis (FFE) device and coupled it to CIEF. The different parameters inherent to the resulting CIEF/FFE system were optimised using ultraviolet absorbance (UV) detection. The on-line coupling of this system with ESI-MS was successfully realised for three model proteins (myoglobin, carbonic anhydrase I and beta-lactoglobulin B).  相似文献   

15.
Many researchers have invested considerable efforts toward improving capillary electrophoresis (CE)-mass spectrometry (MS) systems so they can be applied better to standard analyses. This review highlights the developments in CE-MS of proteins and peptides over the last five years. It includes the developments in interfaces, sample-enrichment techniques, microfabricated devices, and some applications, largely in capillary zone electrophoresis (CZE), capillary isoelectric focusing (CIEF) and capillary isotachophoresis formats.  相似文献   

16.
A new set-up was constructed for capillary isoelectric focusing (CIEF) involving a sampling capillary as a bypass fixed to the separation capillary. Sample solutions were subjected to a previously established pH gradient from the sample capillary. Besides performing conventional CIEF, the separation of ampholytic compounds with isoelectric points (p/s) beyond the pH gradient was carried out on this system. This method was termed as pH gradient driven electrophoresis (PGDE) and the basic mathematical expressions were derived to express the dynamic fundamentals. Proteins such as lysozyme, cytochrome C, and pepsin with p/s higher than 10 or below 3 were separated in a pH gradient provided by Pharmalyte (pH 3-10). Finally, this protocol convincingly exhibited its potential in the separation of a solution of chicken egg white.  相似文献   

17.
The transitional isoelectric focusing (IEF) process (the course of pH gradient formation by carrier ampholytes (CAs) and the correlation of the focusing time with CA concentration) were investigated using a whole-column detection capillary isoelectric focusing (CIEF) system. The transitional double-peak phenomenon in IEF was explained as a result of migration of protons from the anodic end and hydroxyl ions from the cathodic end into the separation channel and the higher electric field at both acidic and basic sides of the separation channel. It was observed that focusing times increase logarithmically with CA concentration under a constant applied voltage. The correlation of focusing time with CA concentration was explained by the dependence of the charge-transfer rate on the amount of charged CAs within the separation channel during focusing.  相似文献   

18.
Graf M  Wätzig H 《Electrophoresis》2004,25(17):2959-2964
Capillary isoelectric focusing (CIEF) is an important tool for the quality assurance of biotechnologically maintained drugs and for proteome analysis. The critical performance parameters of this technique are the precisions of isoelectric point (pI) values and peak areas. Compared to capillary zone electrophoresis (CZE), where precise results can be obtained (e.g., 0.5% relative standard deviation (RSD) for peak areas, n = 60), only few data are available for CIEF experiments. So far, reproducible data of pI values (RSD = 0.5%) have been acquired, but peak areas show inferior results (about 3-15% RSD). Nonstable capillary coatings and protein adsorption have been discussed as possible reasons. Recent work of Righetti et al. [25, 27] has proven that the use of coated capillaries can reduce the adsorption of proteins by 50% but cannot prevent it. In our CIEF experiments irregular and poorly reproducible peak patterns have been observed. In a long-time experiment of 106 repeated runs, an overall RSD of 10% was obtained for peak areas, RSD of 2% only in series of about 10 consecutive replicates. Especially at higher concentrations the reproducibility deteriorates. This seems to be the result of a self-amplifying process, induced by adsorbed protein molecules, leading to further agglomerations. CZE control experiments in linear polyacrylamide (LPA)-coated capillaries proved a strong pH dependency of these effects within a small range. Compared to bare fused-silica surfaces, adsorption effects are reduced but not inhibited. An enhancement of reproducibility in CIEF experiments can be achieved only by controlling the interactions of proteins and capillary walls.  相似文献   

19.
杨春  张维冰  张玉奎 《分析化学》2003,31(9):1097-1100
开发了一种利用鸡卵清蛋白改性毛细管柱内表面的快速方法。改性后的毛细管柱可避免蛋白质样品的吸附作用,在较温和的条件下,柱性能有很好的稳定性,可适用于等电聚焦电泳分离生物样品的需要。  相似文献   

20.
In this study, combination of capillary isoelectric focusing (CIEF) in tapered fused silica (FS) capillary with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is presented as an efficient approach for unambiguous identification of probiotic bacteria in real sample. For this purpose, bacteria within genus Lactobacillus were selected as model bioanalytes and cow's milk was selected as a biological sample. CIEF analysis of both the cultivated bacteria and the bacteria in the milk was optimized and isoelectric points characterizing the examined bacteria were subsequently determined independently of the bacterial sample origin. The use of tapered FS capillary significantly enhanced the separation capacity and efficiency of the CIEF analyses performed. In addition, the cell number injected into the tapered FS capillary was quantified and an excellent linearity of the calibration curves was achieved which enabled quantitative analysis of the bacteria by CIEF with UV detection. The minimum detectable number of bacterial cells was 2 × 106 mL−1. Finally, cow's milk spiked with the selected bacterium was analyzed by CIEF in tapered FS capillary, the focused and detected bacterial cells were collected from the capillary, deposited onto the cultivation medium, and identified using MALDI-TOF MS afterward. Our results have revealed that the proposed procedure can be advantageously used for unambiguous identification of probiotic bacteria in a real sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号