首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 156 毫秒
1.
In this study, a porous polypropylene frit was coated with polydimethylsiloxane (PDMS) as extraction medium, based on the home-made PDMS-frit, a rapid, simple and sensitive sorptive extraction method was established for analysis of potential biomarkers of lung cancer (hexanal and heptanal) in human serum samples. In the method, derivatization and extraction occurred simultaneously on the PDMS-frit, then the loaded frit was ultrasonically desorbed in acetonitrile. Polymerization, derivatization–extraction and desorption conditions were optimized. Under the optimal conditions, satisfactory results were gained, a wide linear application range was obtained in the range of 0.002–5.0 μmol L−1 (R > 0.997) for two aldehydes, the detection limits (S N−1 = 3) were 0.5 nmol L−1 for hexanal and 0.4 nmol L−1 for heptanal. The relative standard deviations (RSDs, n = 5) of the method were below 7.9% and the recoveries were above 72.7% for the spiked serum. All these results hint that the proposed method is potential for disease markers analysis in complex biological samples.  相似文献   

2.
Pyrrolizidine alkaloids (PAs) are alkaloids which typically contain a necine (7-hydroxy-1-hydroxymethyl-6,7-dihydro-5H-pyrrolizidine) base unit, and they can be found in one third of the higher plants around the world. They are hepatotoxic, mutagenic and carcinogenic and pose a threat to human health and safety. A specific, quick and sensitive method is therefore needed to detect and quantify the PAs sometimes in trace amount in herbs, tea or food products. Based on high performance liquid chromatography with prior derivatization of the alkaloids using o-chloranil and Ehrlich's reagent, we report an improved method for quantitative analysis of the total amount of retronecine esters-type pyrrolizidine alkaloids (RET-PAs) in a plant extract. The total quantitation of RET-PAs is achieved because of a common colored retronecine marker, a 7-ethoxy-1-ethoxylmethyl retronecine derivative, is produced with all the different RET-PAs during the derivatization reaction. The chemical identity of the common retronecine marker was characterized on-line by positive mode electrospray ionization mass spectrometry and nuclear magnetic resonance spectroscopy. The limit of detection using the improved method is 0.26 nmol mL−1 and the limit of quantitation is 0.79 nmol mL−1. The advantages of this method are much enhanced sensitivity in detection and quantitation, and, no restriction on the choice of RET-PA as a calibration standard. Application of the developed method to the quantitation of total RET esters-type PAs in Senecio scandens from different regions of China is also reported.  相似文献   

3.
A pre-column derivatization method for the sensitive determination of aldehydes using the tagging reagent 2-[2-(7H-dibenzo[a,g] carbazol-7-yl)-ethoxy] ethyl carbonylhydrazine (DBCEEC) followed by high-performance liquid chromatography with fluorescence detection and APCI-MS identification has been developed. The chromophore of fluoren-9-methoxy-carbonylhydrazine (Fmoc-hydrazine) reagent was replaced by 2-[2-(7H-dibenzo[a,g] carbazol-7-yl)-ethoxy] ethyl functional group, which resulted in a sensitive fluorescence tagging reagent DBCEEC. DBCEEC could easily and quickly labeled aldehydes. The maximum excitation (300 nm) and emission (400 nm) wavelengths did not essentially change for all the aldehyde derivatives. Derivatives were sufficiently stable to be efficiently analyzed by high-performance liquid chromatography. The derivatives showed an intense protonated molecular ion corresponding m/z [M + (CH2)n]+ in positive-ion mode (M: molecular weight of DBCEEC, n: corresponding aldehyde carbon atom numbers). The collision-induced dissociation of protonated molecular ion formed fragment ions at m/z 294.6, m/z 338.6 and m/z 356.5. Studies on derivatization demonstrated excellent derivative yields in the presence of trichloroacetic acid (TCA) catalyst. Maximal yields close to 100% were observed with a 10 to 15-fold molar reagent excess. Separation of the derivatized aldehydes had been optimized on ZORBAX Eclipse XDB-C8 column with aqueous acetonitrile as mobile phase in conjunction with a binary gradient elution. Excellent linear responses were observed at the concentration range of 0.01-10 nmol mL−1 with coefficients of >0.9991. Detection limits obtained by the analysis of a derivatized standard containing 0.01 nmol mL−1 of each aldehyde, were from 0.2 to 1.78 nmol L−1 (at a signal-to-noise ratio of 3).  相似文献   

4.
A novel technique for derivatization in a gas chromatograph injection port after a one-step extraction of trace perfluorocarboxylic acids (PFCAs) in water with ion pair formation during dispersive liquid–liquid microextraction (DLLME) was investigated. Tetrabutylammonium hydrogen sulfate (TBAHS) was used as the ion pair reagent. PFCA butyl ester derivatives were formed in the GC injection port and then analyzed using gas chromatography coupled to tandem mass spectrometry with negative chemical ionization. According to our analysis, the operative linear range for PFCA detection from 250 pg mL−1 to 2 μg mL−1 with a relative standard derivation (RSD) below 13%. Detection limits were achieved at the level of 37–51 pg mL−1. This method was successfully applied for the analyzing of PFCAs in river water samples from urban and industrial areas without tedious pretreatment. The concentration range over which PFCAs were detected is from 0.6 ng mL−1 to 604.9 ng mL−1.  相似文献   

5.
A novel sample preparation method, vial wall sorptive extraction (VWSE), which uses a vial whose internal wall is coated with polydimethylsiloxane (PDMS), was developed. The method was applied to the determination of progesterone in human serum sample. Human serum sample (0.5 mL) spiked with progesterone-13C2 was pipetted into the VWSE device and vortex mixing was performed for 30 min. Then, the serum sample was removed and the vial rinsed with purified water. Fifty microliter of methanol as liquid desorption (LD) solvent was pipetted into the VWSE device and vortex mixing was performed for 10 min. Then, the extract was analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The correlation coefficient (r) of the calibration curve over the concentration range of 0.5–200 ng mL−1 was 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.1 and 0.5 ng mL−1, respectively. The relative recoveries were 97.9% (RSD: 4.4%, n = 6) and 102.8% (RSD: 1.1%, n = 6) for progesterone spiked at 5 and 50 ng mL−1, respectively. This simple, accurate, sensitive, and selective analytical method is applicable to the trace analysis of a minute amount of sample.  相似文献   

6.
Reaction of formaldehyde with amino acids followed by oxidation with hydrogen peroxide to produce a fluorophore Norharman product is well known and was used for the spectrofluorimetric determination of l-tryptophan (Trp). This study aimed to use graphene oxide (GO) to enhance the selectivity and sensitivity of Trp in presence of other amino acids and possible interfering compounds. Different parameters such as pH, temperature, incubation time, and concentrations of formaldehyde, H2O2 and GO were studied to optimize the condition of determination. Experimental data showed that the maximum fluorescence intensity was achieved in pH 7.0–9.0 phosphate buffer mixed with 7–10% (v/v) formaldehyde and 1–2% (v/v) H2O2 as oxidizing agent at 60 ?C for 1 h. On the basis of calibration curve of various concentrations of Trp in the presence of 20 μg mL−1 GO, the lower limit of detection (LOD) of Trp was determined as 0.092 nmol mL−1 and the lower limit of quantification (LOQ) was 0.3 nmol mL−1. The selectivity of Trp in presence of other amino acids and possible interfering compounds were studied with and without GO. The data obtained after inner filter effect corrections revealed that the selectivity of Trp in presence of amino acids and other possible interfering agents was improved in the range of 76–96%, compared with that in absence of GO. The enhancement of selectivity in the presence of GO indicates that the Trp and other amino acid and possible interfering compounds were adsorbed by GO, and the selective uptaking of Trp-by the reaction with formaldehyde followed by oxidation with H2O2 at 60 ?C with high selectivity and sensitivity was achieved successfully.  相似文献   

7.
A micellar electrokinetic capillary chromatography (MEKC) method with laser-induced fluorescence detection (LIF) was developed for analyzing three phosphoamino acids including phosphotyrosine (P-Tyr), phosphoserine (P-Ser), and phosphothreonine (P-Thr). 3-(2-Furoyl)quinoline-2-carboxaldehyde (FQ), a fluorogenic dye, was employed for derivatization of these phosphoamino acids. Results indicated that the complete baseline resolution of each phosphoamino acid was obtained within 10 min, using 20 mmol l−1 sodium borate buffer (pH 9.35) containing 20 mmol l−1sodium deoxycholate (SDC) and 10 mmol l−1 Brij35. Other common amino acids, especially Glu and Asp, did not disturb the assay of these phosphoamino acids. There was a linear relationship between the peak area for analyte and its concentration, with correlation coefficients in the range of 0.9966-0.9996. The concentration detection limits (signal-to-noise = 3) for P-Tyr, P-Ser, and P-Thr were 10, 40, and 75 nmol l−1, respectively. The developed method was successfully applied for determining phosphoamino acids in the hydrolysis sample of a phosphorylated protein kinase.  相似文献   

8.
An analytical protocol for the isolation and quantification of indole-3-acetic acid (IAA) and its amino acid conjugates was developed. IAA is an important phytohormone and formation of its conjugates plays a crucial role in regulating IAA levels in plants. The developed protocol combines a highly specific immunoaffinity extraction with a sensitive and selective LC-MS/MS analysis. By using internal standards for each of the studied compounds, IAA and seven amino acid conjugates were analyzed in quantities of fresh plant material as low as 30 mg. In seeds of Helleborus niger, physiological levels of these compounds were found to range from 7.5 nmol g−1 fresh weight (IAA) to 0.44 pmol g−1 fresh weight (conjugate with Ala). To our knowledge, the identification of IAA conjugates with Gly, Phe and Val from higher plants is reported here for the first time.  相似文献   

9.
Zhuo SJ  Zheng H  Chen JL  Li DH  Wu YQ  Zhu CQ 《Talanta》2004,64(2):528-533
A new method was developed for determination of micro amounts of nucleic acids based on near-infrared (near-IR) fluorescence recovery, employing a two-reagent system which is composed of an anionic tetracarboxy aluminum phthalocyanine (AlC4Pc) and a cationic tetra-N-hexadecylpyridiniumyl porphyrin (TC16PyP). The fluorescence of the AlC4Pc, with the maximum emission wavelength at 701 nm, could be quenched by TC16PyP at its proper concentration, but recovered by adding nucleic acids. Under optimal conditions, the recovered fluorescence is proportional to the concentration of nucleic acids. The calibration graphs are linear over the range of 1-200 ng mL−1 for fish sperm DNA (FS DNA) and 2-400 ng mL−1 for calf thymus DNA (CT DNA). The corresponding detection limits are 0.59 ng mL−1 for FS DNA and 0.82 ng mL−1 for CT DNA, respectively. Four synthetic and three real nucleic acid samples were determined with satisfactory results.  相似文献   

10.
A fast, simple, and sensitive flow injection analysis method was developed for the measurement of semicarbazide-sensitive amine oxidase (SSAO) activity in human serum. Benzaldehyde, generated by the action of SSAO after incubation of serum with benzylamine, was derivatized with a novel aromatic aldehyde-specific reagent (1,2-diaminoanthraquinone) and the fluorescent product was measured by fluorescence detection at excitation and emission wavelengths of 390 and 570 nm, respectively. Serum SSAO activity was defined as benzaldehyde (nmol) formed per milliliter serum per hour. The method was linear over SSAO activity of 0.2–150.0 nmol mL−1 h−1 with a detection limit of 0.06 nmol mL−1 h−1. The %RSD of intra-day and inter-day precision did not exceed 9.4% and the accuracy ranged from −6.5 to −0.6%. The method was applied for the determination of the serum SSAO activity in healthy controls (C, n = 24) and diabetes mellitus patients (DM, n = 18). It was demonstrated that the activity (mean ± SE) of SSAO in diabetics sera was significantly higher than that in healthy subjects’ ones (DM; 73.3 ± 1.8 nmol mL−1 h−1vs C; 58.9 ± 2.2 nmol mL−1 h−1, P 0.01).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号