首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 562 毫秒
1.
Zeng HL  Shen H  Nakagama T  Uchiyama K 《Electrophoresis》2007,28(24):4590-4596
The aqueous solution of a kind of room-temperature ionic liquids (RTILs), 1-ethyl-3-methylimidazolium-tetrafluoroborate (1E-3MI-TFB), demonstrated its exclusive electroosmotic property in microchip electrophoresis. It was applied as the working electrolyte for chiral separation in glass microchip electrophoresis. Compared with boric acid buffer, 1E-3MI-TFB aqueous solution exhibited a broader separation window for enantiomers of dipeptides. Then the influences of chiral selector, pH and concentration on efficiency of chiral separation were discussed in detail. The unique mechanism of the generation of EOF was explored in a glass microchannel using 1E-3MI-TFB aqueous solution as working electrolyte. A possible status of 1E-3MI cation in water was suggested at the first time, which facilitated the explanation of EOF and its characteristics in glass microchannel. Additionally, microchip electrophoresis using 1E-3MI-TFB aqueous solution was successfully applied to the chiral separation of complex enantiomers of dipeptides. RTILs aqueous solution, as the electrolyte for the separation of complicated optical isomers, could lead to a revolution in the analytical methods of chiral or conformational analysis for biomolecules.  相似文献   

2.
A fused-silica capillary that is wall-modified via chemically bonding a sulfonated polymer to the capillary wall has a uniform negative charge density on its surface and produces an electroosmotic flow (EOF) greater than 4 x 10(-4) cm2 V(-1) s(-1) The EOF is nearly independent of buffer pH over the pH range of 2 to 10 and is lower than the EOF obtained for the bare fused-silica capillary at the more basic pH but is higher at the more acidic buffer pH. Optimization of buffer pH can be based on analyte pKa values to improve the overall quality of the capillary zone electrophoresis (CZE) separation of complex mixtures of weak acid and base analytes. Because of the high EOF in an acidic buffer, the capillary is useful for the separation of weak organic bases which are in their cation forms in the acidic buffer. EOF for the sulfonic acid bonded phase capillary can be adjusted via buffer additives such as organic solvent, tetraalkylammonium salts, multivalent cations and alkylsulfonic acids. The advantages of utilizing buffer pH and the EOF buffer modifiers to enhance migration time, selectivity, and resolution in CZE separations with this capillary are illustrated using a series of test analyte mixtures of inorganic anions, carboxylic acids, alkylsulfonic acids, benzenesulfonic acids, sulfas, pyridines, anilines or small-chain peptides.  相似文献   

3.
A novel compound ?quaternarized piperazine [(N-methyl,N-4-iodobutyl)-N'-methylpiperazine] (QPzI)? for the coating of a silica capillary able to reduce or invert the electroosmotic flow (EOF) in capillary zone electrophoresis is reported. Unlike standard oligoamines (like spermine and tetraethylene pentamine) which are very efficient in quenching macromolecule interaction with the silica wall, but only in acidic pH ranges, QPzI acts all along the pH scale, including alkaline pH ranges. It is believed that QPzI behaves like a trifunctional derivative: it forms ionic bonds with dissociated silanols via its quaternary nitrogen, hydrogen bonds via its tertiary nitrogen and, most importantly, a covalent bond via alkylation of ionized silanols through the terminal iodine atom in the butyl chain. Excellent separations are obtained with a variety of organic compounds, such as aromatic carboxylic acids, tryptophan metabolites and arylalkanoic acids. Such separations could not be obtained in naked capillaries in the presence of oligoamines and on some occasions not even with capillaries coated with a covalent layer of neutral polymers. In separations taking place in alkaline media, QPzI is not added to the background electrolyte, but is used simply in the capillary pre-conditioning step, a unique feature strongly supporting the hypothesis of its covalent binding to the silica surface. In difficult separations, such as in the case of o-/p-OMe-phenylacetic acids or nicotinic/picolinic acid, which would not normally occur under standard conditions, it is believed that QPzI acts as a discriminator, thus playing an active role in the separation process, rather than simply modulating the EOF.  相似文献   

4.
This report describes the creation of semipermanent capillary coatings that are compatible with organic-water solvent systems in CE. The coatings are created by simply rinsing the fused-silica capillary with long double-chain cationic surfactants, such as dimethyl-ditetradecyl ammonium bromide (2C(14)DAB), dihexadecyldimethyl ammonium bromide (2C(16)DAB), and dimethyldioctadecyl ammonium bromide (2C(18)DAB). These surfactants generate semipermanent bilayer coatings on the capillary surface, which display a high degree of stability in buffers containing up to 60% v/v of organic solvents, such as methanol and ACN. The coating stability increases with increasing hydrophobicity of the surfactant, i.e., with increasing chain length. For instance, the EOF changes by only 1.2% in a 2C(18)DAB-coated capillary after 130 capillary volumes of rinsing with 60% v/v methanol containing buffer. The bilayer coatings allow separations to be performed without the need to regenerate the coating between runs or to maintain the EOF modifier in the run buffer. Rapid separations (<2 min) of anions and basic drugs with migration time reproducibility of less than 0.5% RSD and efficiencies of 0.4-0.6 million plates/m are obtained. In addition, selectivity changes for small anions and cationic drugs are also observed when the organic solvent content is adjusted.  相似文献   

5.
Two novel polysiloxanes containing the metal complex, Co(TACN)(3+)2 (TACN= 1,4,7-triazacyclononane) were used as coatings for capillary electrophoresis (CE) and capillary electrochromatography (CEC). Through crosslinking and covalent bonding, the positively charged polymers were bonded to silica supports. In both CE and CEC, these coatings exhibited strong, pH-independent, and anodic electroosmotic flow (EOF), and had excellent long-term stability. Successful separations of aromatic acids were achieved in CE. In CEC, separation of alkylbenzenes (7 min) and basic compounds (20 min) was achieved with higher resolving power than conventional octadecyl silica packings. These polymers represent a new class of coatings for CE and CEC that generate pH-independent EOF.  相似文献   

6.
Control of the electroosmotic flow (EOF) is critical for achieving optimal separations by capillary electrophoresis. For instance, manipulation of the EOF can yield either high resolution separations or rapid analyses. Dynamic capillary coatings are a simple and cost-effective approach to altering the EOF. The normal EOF can be slowed using buffer additives such as Mg2+ and hexamethonium which ion exchange onto the surface silanols to lower the effective wall charge. Alternatively, cationic polyelectrolytes or cationic surfactants can be used to establish a cationic coating on the capillary wall, which results in a reversed EOF. Practical considerations such as pH stability and reproducibility obtainable with an EOF modifier will be discussed.  相似文献   

7.
Manipulation of the electroosmotic flow (EOF) is essential for achieving optimized separations of small anions by capillary electrophoresis (CE). In this work, efficient suppression or reversal of EOF is achieved upon addition of small amounts of the cationic surfactants, cetyltrimethylammonium bromide (CTAB) or didodecyldimethylammonium bromide (DDAB) to the electrophoretic buffer. Highly stable and reversed EOF are achieved using the surfactants in the presence of up to 50% MeOH. In aqueous and low methanol containing solutions (up to 30%, v/v) surface aggregation of the surfactants at the capillary wall occurs at a concentration below the critical micelle concentration (CMC). The impact of MeOH on reversed EOF is predominantly a function of the diminished zeta potential of the silica, and to a lesser extent on the CMC in the bulk solution of the surfactant. Fast baseline separation and selectivity changes for small inorganic anions are observed when mixed aqueous-organic buffers are employed. Changes in EOF, micellar properties of the surfactant and selectivity for inorganic anions upon addition of various percent of methanol are also discussed.  相似文献   

8.
A new application of the polymeric ionic liquid (PIL) in capillary electrophoresis is reported. Poly(1-vinyl-3-butylimidazolium bromide) was physically adsorbed on silica capillary as the simple and effective coating for capillary electrophoresis (CE) analysis, in which the PIL is not present in the background electrolyte. The electroosmotic flow (EOF) of the PIL-coated capillary as compared with that of the bare fused-silica capillary shows a different dependence on electrolyte pH values. The EOF is reversed over a wide pH range from 3.0 to 9.0 and shows good repeatability. It is also found that the coated capillary has a good tolerance to some organic solvents, 0.1 M NaOH and 0.1 M HCl. The PIL-coated capillary has been employed in different areas. Both the basic proteins and anionic analytes can be well separated by PIL-coated capillaries in a fast and easy way. The PIL-coated capillary is also able to separate organic acid additives in a grape juice. The results showed that this type of coating provides an alternative to the CE separation of anions and basic proteins.  相似文献   

9.
Zhou S  Tan J  Chen Q  Lin X  Lü H  Xie Z 《Journal of chromatography. A》2010,1217(52):8346-8351
A novel open tubular (OT) column covalently modified with hydrophilic polysaccharide, carboxymethylchitosan (CMC) as stationary phase has been developed, and employed for the separations of basic proteins and opium alkaloids by capillary electrochromatography (CEC). With the procedures including the silanization of 3-aminopropyltrimethoxysilane (APTS) and the combination of glutaraldehyde with amino-silylated silica surface and CMC, CMC was covalently bonded on the capillary inner wall and exhibited a remarkable tolerance and chemical stability against 0.1 mol/L HCl, 0.1 mol/L NaOH or some organic solvents. By varying the pH values of running buffer, a cathodic or anodic EOF could be gained in CMC modified column. With anodic EOF mode (pH<4.3), favorable separations of basic proteins (trypsin, ribonuclease A, lysozyme and cytochrome C) were successfully achieved with high column efficiencies ranging from 97,000 to 182,000 plates/m, and the undesired adsorptions of basic proteins on the inter-wall of capillary could be avoided. Good repeatability was gained with RSD of the migration time less than 1.3% for run-to-run (n=5) and less than 3.2% for day-to-day (n=3), RSD of peak area was less than 5.6% for run-to-run (n=5) and less than 8.8% for day-to-day (n=3). With cathodic EOF mode (pH>4.3), four opium alkaloids were also baseline separated in phosphate buffer (50 mmol/L, pH 6.0) with column efficiencies ranging from 92,000 to 132,000 plates/m. CMC-bonded OT capillary column might be used as an alternative medium for the further analysis of basic proteins and alkaline analytes.  相似文献   

10.
Capillary electrophoretic separations of inorganic anions are performed using a capillary coated with a mixture of the cationic surfactant didodecyldimethylammonium bromide (DDAB) and the zwitterionic surfactant 1,2-dilauroyl-sn-phosphatidylcholine (DLPC). These double-chained surfactants form semi-permanent coatings on the capillary wall, which allows the excess surfactant to be removed from the buffer prior to separation. Interactions between surfactant aggregates in the buffer and analyte anions are thus eliminated. The electroosmotic flow (EOF) can be altered from fully reversed (100% DDAB) to near zero (100% DLPC) using different ratios of DDAB and DLPC. Controlling the EOF allows for improved resolution of the anions while maintaining a rapid, co-EOF separation, free from analyte-surfactant additive interactions.  相似文献   

11.
A novel and easy method for the separation of inorganic anions by capillary electrophoresis using a polymeric ionic liquid (PIL), poly(1-vinyl-3-butylimidazolium bromide) as a background electrolyte modifier has been developed. The PIL has been proved to generate a reversed electroosmotic flow which reduces the analysis time and improves the separation significantly. Effects of the PIL concentration and buffer composition (pH and concentration) were evaluated on basis of the resolution and efficiency of the sample. Under optimum conditions, good separation of six model inorganic anions was achieved with high efficiency and excellent reproducibility within 3 min. The results obtained indicate that the combination of reversed EOF and the association between the analytes and the PIL on the capillary wall or BGE play a prominent role in the separation of anions. Therefore, the PIL presents a useful alternative for the BGE modifier in the study of inorganic anions by CE.  相似文献   

12.
A physically adsorbed and covalently bonded porphyrin derivative, 5,10,15,20-tetrakis(pentafluorophenyl)porphyrin, H2TPFPP, has been used as a fused-silica capillary wall modifier in open tubular capillary electrochromatography (OT-CEC), and its influence on the electroosmotic flow (EOF) velocity and on the selectivity of OT-CEC separations of a set of model aromatic carboxylic acids has been tested. Whereas most of the coatings of this category bring about an increase in selectivity with a concomitant slow down of the EOF, H2TPFPP coating, depending on pH of the background electrolyte used, resulted both in decreasing of EOF at pH 8.5 by 5% and in increasing of EOF by 10–43% at pH 6 and 5, respectively. The separation efficiency and the resolution of aromatic carboxylic acids separation in coated capillaries, namely in that one with covalent coating, were better than in the bare fused-silica capillary. The perspectives of H2TPFPP as capillary wall modifier are visualized in introducing well defined electroosmotic properties of materials used for miniaturized separation channels preparation in chip-based electromigration devices.  相似文献   

13.
The simultaneous determination of polycarboxylic acids including oxalic acid, citric acid, malonic acid, malic acid, tartaric acid, aspartic acid and glutamic acid was achieved by capillary electrophoresis with a copper disk electrode (d = 200 microm). In the system. 0.2 mmol/l cetylpridinium bromide (CPB) was used as an electroosmotic flow (EOF) modifier to reverse the direction of EOF. The effects of the solution pH and CPB concentration on separation were evaluated to achieve the optimum separation conditions. At the working potential of +0.14 V (vs. saturated calomel electrode), the calibration curves for all polycarboxylic acids studied were linear with 2 approximately 3-orders of magnitude and all the detection limits (S/N = 3) were below 15 fmol except malonic acid. Furthermore, the oxalic and citric acids in urine were successfully separated and determined with high sensitivity.  相似文献   

14.
The differential behavior of five different quaternary mono- and diammonium salts, among the 18 investigated, in modulating the electroendoosmotic flow (EOF) and analyte separations in capillary zone electrophoresis is evaluated. It is found that quaternary diammonium salts with positive charges separated by more than four carbon atoms, while exhibiting a very strong affinity for chromatographic silica beads, to the point of exhibiting Rf values close to zero, display, on the contrary, a very poor affinity for the silica wall of capillaries. Compounds separated only by a C2 unit (i.e., 1,4-dialkyl-1,4-diazoniabicyclo[2,2,2,]octane, salts 17 and 18) show high Rf values due to strong ion pair association. The unique behavior of quaternary monoammonium salts possessing an iodinated alkyl (butyl or octyl) tail (i.e., 1, 6, and 7) is attributed to their ability to be covalently affixed to the silica wall via alkylation of ionized silanols at alkaline pH values. They thus strongly modulate and typically invert the EOF, even when not present in the background electrolyte. On the contrary, all diammonium salts, devoid of such alkyl tails, are unable to modulate the EOF and to prevent analyte binding to the silica wall, since they are rapidly removed from the wall by the voltage gradient. However, if added in small amount to the background electrolyte, they offer excellent separations of mixtures of very similar organic acids and prevent any interaction with the capillary wall.  相似文献   

15.
New dynamic coating agents were investigated for the manipulation of electroosmotic flow (EOF) in poly(methylmethacrylate) (PMMA) microchips. Blocking proteins designed for enzyme-linked immunosorbent assay (ELISA) applications (e.g. Block Ace and UltraBlock), and egg-white lysozyme were proposed in this study. The EOF could be enhanced, suppressed or its direction could be reversed, depending on the buffer pH and the charge on the proteins. The coating procedure is simple, requiring only filling of the microchannels with a coating solution, followed by a rinse with a running buffer solution prior to analysis. One major advantage of this method is that it is not necessary to add the coating agent to the running buffer solution. Block Ace and UltraBlock coatings were stable for at least five runs in a given microchannel without the need to condition the coating between runs other than replenishing the buffer solution after each run, i.e. the RSD values of EOF (n=5) were less than 4.3%, and there was no significant change in the EOF after 5 runs. The reproducibility of the coating procedures was found from the channel-to-channel RSD values of the EOF, and were less than 5.0% when using HEPES-Na buffer (pH 7.4) as the running buffer. Several examples of electrophoretic separations of amino acids and biogenic amines derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) are demonstrated in this paper. The dynamic coating method has the potential for a broad range of applications in microchip capillary electrophoresis (microchip CE) separations.  相似文献   

16.
A background electrolyte for capillary electrophoresis containing tris(-hydroxymethyl) aminomethane (THAM) and ethanesulfonic acid (ESA) gives excellent efficiency for separation of drug cations with actual theoretical plate numbers as high as 300,000. However, the analyte cations often elute too quickly and consequently offer only a narrow window for separation. The best way to correct this is to induce a reverse electroosmotic flow (EOF) that will spread out the peaks by slowing their migration rates, but this has always been difficult to accomplish in a controlled manner. A new method for producing a variable EOF is described in which a low variable concentration of tributylammonium- or triethylammonium ESA is added to the BGE. The additive equilibrates with the capillary wall to give it a positive charge and thereby produce a controlled opposing EOF. Excellent separations of complex drug mixtures were obtained by this method.  相似文献   

17.
It is well known that poor quantitative reproducibility substantially limits the practical implementation of capillary electrophoresis (CE) separations in chemical analysis. The principal sources of variance in observed peak areas are irreproducible flow rate, which influences on-column detector response, and inconsistent injection volume or amount. An overview of studies by researchers to address the reproducibility issue will be presented. In addition, current efforts in our laboratory to assess sources of quantitative variance for separations of dansylated amino acids using an automated CE system are presented and related when appropriate to the body of existing knowledge on this important topic. A comparison of different injection methods (hydrostatic vs. electrokinetic) and approaches (e.g., high vs. low pressure), the effect of random changes in electroosmotic flow (EOF) due to air bubbles in the CE capillary, and choice of certain peak integration parameters in terms of peak area reproducibility are presented. Under optimum conditions relative standard deviation (RSD) values in raw peak area are typically 2.0%. With nonoptimum conditions (e.g., with air bubbles in capillary), RSD values can substantially degrade. However, normalizing with retention times, internal standards, or observed electrophoretic current produces RSD values in a range of 1.4-2.3%.  相似文献   

18.
Ghosal S 《Electrophoresis》2004,25(2):214-228
Electroosmotic flow (EOF) usually accompanies electrophoretic migration of charged species in capillary electrophoresis unless special precautions are taken to suppress it. The presence of the EOF provides certain advantages in separations. It is an alternative to mechanical pumps, which are inefficient and difficult to build at small scales, for transporting reagents and analytes on microfluidic chips. The downside is that any imperfection that distorts the EOF profile reduces the separation efficiency. In this paper, the basic facts about EOF are reviewed from the perspective of fluid mechanics and its effect on separations in free solution capillary zone electrophoresis is discussed in the light of recent advances.  相似文献   

19.
Enantiomer separations of underivatised amino acids were carried out by using ligand exchange capillary electrophoresis (LECE). Chiral discrimination is based on the formation of ternary complexes between copper(II), a chiral selector (L-proline or trans-4-hydroxy-L-proline) and an amino acid. All amino acids containing aromatic moieties or not were detected at 214 nm because of their interactions with copper(II). In order to reduce copper(II) adsorption onto capillary walls, we used hexadimethrine bromide to reverse the electroosmotic flow. Using this original strategy, the studied enantiomers migrated in the opposite direction of the anodic electroosmosis. After optimising the analytical conditions taking into account the chiral resolution and the detection sensitivity, we performed very satisfactory enantioseparations not only of aromatic amino acids (tryptophan, tyrosine, phenylalanine and histidine) but also of aliphatic amino acids (threonine, serine, isoleucine and valine). These enantioseparations were performed in a short analysis time at 35 °C. In order to rationalise the obtained results, we evaluated the complexation constants corresponding to the formed ternary complexes by capillary electrophoresis and we used molecular mechanics modelling.  相似文献   

20.
The effect of high voltage on capillary electrophoresis (CE) separations of anionic analytes in nonaqueous separation media was investigated. Methanol, ethanol, 1-propanol, and 1-butanol were tested as background electrolyte (BGE) solvents. Experiments were carried out with a laboratory-built CE instrument suitable for high-voltage separations. Potentials up to 60 kV were applied with reversed polarity to generate unusually high field strengths (e.g. 2000 Vcm-1) and so achieve fast and efficient separations. Highest separation efficiencies were obtained with propanol as BGE solvent, and the dependency of the efficiency on the separation voltage was more or less linear. With the other alcohols, separation efficiency decreased or remained roughly constant with increasing absolute voltage. The separation efficiencies are discussed in terms of longitudinal diffusion, Joule heating, and analyte interaction with the capillary wall. Capillary preconditioning had a varied effect on the separations in the different BGEs as the BGE and the conditioning process affected the electroosmotic flow (EOF) velocity and direction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号