首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
应用激光解吸电离飞行时间质谱对几种不同结构的吡嗪稠环齐聚物进行了表征.样品溶解在二甲基亚砜中,以正离子方式记录谱图,结果发现除了产生目标化合物的质子化的分子离子峰外,还产生了少量的碎片分子离子峰.结果表明激光解吸电离飞行时间质谱能有效地、快速准确地给出这类化合物的分子离子峰,为吡嗪类稠环齐聚物的研究提供了有效的表征方法.  相似文献   

2.
We have employed a light-absorbing electrically conductive polymer as a matrix to determine the molecular mass of small organic molecules using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. This method, which is in contrast to the usual MALDI strategy for matrix selection in which a small molecule matrix is used with a high molecular mass analyte, addresses the problem of matrix interference which limits the usefulness of MALDI-TOF for small molecule analysis. Use of negative ion mode offers advantages for this application. Using this approach, we have obtained clean molecular ion mass spectra of small organic molecules in the mass range 100-300 Da.  相似文献   

3.
通过激光解吸电离飞行时间质谱对meso-四(对烷氧苯基)卟啉金属银配合物进行了表征.样品溶解在氯仿中,以正离子方式记录谱图,结果发现除了产生目标化合物分子离子峰外,没有任何碎片峰.激光解吸电离飞行时间质谱是表征这种meso-四(对烷氧苯基)卟啉金属银配合物有效的方法.  相似文献   

4.
The use of non-polar, small polymers as matrices for the analysis of low molecular weight compounds in polymer-assisted laser desorption/ionization mass spectrometry (PALDI-MS) is demonstrated. The matrices evaluated were either based on an oligothiophene or a benzodioxin backbone. Metallocenes, polycyclic hydrocarbons, a fluorosurfactant, and a subset of small organic compounds with various functionalities, served as model analytes. The mechanism of ionization charge transfer is discussed and ionization potentials for the matrices in the study have been estimated using density functional theory (DFT) calculations. Some of the results are possibly contradictory to the generally accepted limiting conditions for gas-phase charge-transfer reactions. These results are interpreted in the light of energy pooling. Also a new mass calibration procedure for the low-mass region in positive ion mode is presented, and some aspects of the ionization/desorption process leading to radical cations are studied.  相似文献   

5.
Analysis of organic compounds in aerosol particles using real-time single particle techniques is difficult because of extensive fragmentation that occurs in the laser desorption/ionization step. In an effort to avoid such fragmentation processes, we coupled a “soft” two-step laser desorption/ionization technique (L2MS) with aerosol time-of-flight mass spectrometry (ATOFMS). In these studies, we find this combination preserves intact organic molecules while providing the real-time mass spectra of suspended aerosol particles. Mass spectra of particles analyzed by one-step desorption mass spectrometry and L2MS are presented for comparison. These include 2,4-dihydroxybenzoic acid as a test case and wood and cigarette combustion particles as real world examples. This is the first published demonstration of L2MS performed on single particles not deposited on a substrate prior to analysis.  相似文献   

6.
Three commercial oral rinses and one commercial disinfectant formulation were analyzed for the presence of cationic surfactants using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) in the positive ion mode. The product labels on these formulations indicate the presence of cetylpyridinium chloride, tetraalkylammonium or trialkylbenzylammonium chlorides. The resulting MALDI-TOF mass spectra only showed cetylpyridinium, tetraalkylammonium, and trialkylbenzylammonium ions, apparently due to the dissociation of the salts in the ion source. We confirmed the presence of cetylpyridinium salt in the three oral formulations, whereas the disinfectant formulation consisted of a complex mixture of the salts of dioctyldimethylammonium, didecyldimethylammonium, benzylmyristyldimethylammonium, decyloctyldimethylammonium, benzyldecyldimethylammonium, and benzylcetyldimethylammonium. This work demonstrates again the potential for using meso-tetrakis(pentafluorophenyl)porphyrin as a matrix in the MALDI-TOFMS analysis of low molecular weight compounds. This study also demonstrates that the mode of ionization of quaternary ammonium compounds (cationic surfactant salts) under MALDI conditions is by dissociation, leading to the detection of only the positively charged moieties.  相似文献   

7.
Mass spectrometry is widely applied in carbohydrate analysis, but still quantitative evaluation of data is critical due to different ionization efficiencies of the constituents in a mixture. Different size and chemical structure of the analytes cause their uneven distribution in droplets (electrospray ionization, ESI) or matrix spots (matrix-assisted laser desorption/ionization, MALDI). In addition, instrumental parameters affect final ion yields. In order to study and optimize the latter, an equimolar mixture of malto-oligosaccharides (DP1-6) was analyzed using varying target masses for ESI as well as different matrices and laser power for MALDI. The sodium adducts and derivatives for positive ion mode (hydrazones with Girard's T Reagent, GT) and negative ion mode (reductively aminated with o-aminobenzoic acid, oABA) were studied. Negatively charged oABA-labeled malto-oligosaccharides turned out to be unsuitable for quantification of the malto-oligomeric composition. Best agreement was achieved when applying target masses in the range of the highest homolog in the mixture in electrospray ionization ion trap (ESI-IT) (1-2% deviation with GT label or as Na(+) adducts). Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) gave best results when the laser power was adjusted significantly over the desorption/ionization threshold (1% deviation with GT label). Both parameters show significant influence on the determined oligomeric composition. Consequently, estimation and even quantitative determination of amounts of oligosaccharides in a mixture can be achieved when the analytes are labeled and the proper instrumental parameters are used.  相似文献   

8.
The results of investigation of ruthenium carborane complexes with chelating diphosphine ligands by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry are presented. The influence of matrix, power of laser irradiation, and analysis mode on the substrate fragmentation and spectra is analyzed. It is shown that the best spectra are recorded in the negative ion mode with DCTB as a matrix.  相似文献   

9.
We report the application of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) for the accurate measurement of mass of low molecular weight compounds (smaller than 1500 Da), a linear peptide, two types of cyclic depsipeptides, a polyhydroxy-macrocyclic lactone, and two prenylated flavonoids, with delayed extraction in the reflector mode. The performance of the MALDI-TOF instrument was less than those of fast atom bombardment and Fourier-transform ion cyclotron resonance mass spectrometry instruments and insufficient to give acceptable accuracy for literature reporting. Nevertheless, when combined with NMR spectrometry and/or amino acid analysis to give information on the numbers of carbon atoms and index of hydrogen deficiency, MALDI was useful for determination of the elemental composition of the low molecular weight compounds available in small quantities.  相似文献   

10.
选用液相基质制样,考察了激光强度、回旋池开门时间等因数对基质辅助激光解吸电离-傅里叶变换离子回旋共振质谱(MALDI—FT—ICR—MS)检测结果的影响,优化了实验条件。使用液相制样方法对5类实际样品进行了MALDI—FT-ICR—MS检测,结果表明:液相基质具有很好的通用性,质谱信号稳定、持久。利用FT-ICR—MS特有的超高分辨率与准确度,能够很准确地测定化合物组成。  相似文献   

11.
We evaluated several aqueous-based sample preparation protocols for the analysis of poly(methacrylic acid) (PMAA) by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). The sample contained a pentaerythritol tetra(3-mercaptopropionate) end-group, and was characterized in positive and negative ion modes using 2,5-dihydroxybenzoic acid (DHB) and 2,4,6-trihydroxyacetophenone (THAP) matrices. The major series observed were the [M + Na](+) species, in positive ion mode, and the [M - H](-) species, in negative ion mode. The performance of DHB and THAP matrices was comparable in positive ion mode, but THAP outperformed DHB in negative ion mode. The use of ion-exchange beads (IXB) benefited the analysis, while the addition of sodium acetate (NaOAc) or trifluoroacetic acid (TFA) proved disadvantageous in positive ion mode.  相似文献   

12.
Matrix-assisted laser desorption/ionization (MALDI) time-of-flight (ToF) mass spectrometry (MS) is an established tool for analyzing high mass molecules, such as proteins, whereas it attracts far less interest in the field of lipid analysis. In the study reported here a new chlorosulfolipid (CSL), 3,8,12,15-tetrachloroeicosane-1,17,18-triyl tris(hydrogen sulfate), was identified from the alga Ochromonas danica and de novo characterized by matrix-assisted laser desorption/ionization quadrupole ion trap time-of-flight (MALDI-QIT-ToF) MS in negative ion mode. This method provides an effective alternative for the analysis of compounds directly derived from organic cell extracts. For MALDI analyses several frequently used solid MALDI matrices as well as some ionic liquid matrices (ILMs) were tested to enhance the analyte response to UV-laser and its ionization. The molecular weight of the observed compound could be determined as Li-, Na- and K-adducts [M+Me-2H]-. The characteristic isotopic patterns of the measured ions and the well-allocated molecular fragments by MS1, MS2 and MS3 indicate the fourfold chlorination and threefold sulfation of the investigated compound. The MS fragmentation alongside of the chlorine-bearing C-atoms is accompanied by the generation of a double bond at the opposite fragment in MS1. This obtained fragmentation pattern provides an insight into the allocation of the chlorine-bearing C-atoms along the carbon chain.  相似文献   

13.
Comparative MS/MS studies of singly and doubly charged electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) precursor peptide ions are described. The spectra from these experiments have been evaluated with particular emphasis on the data quality for subsequent data processing and protein/amino acid sequence identification. It is shown that, once peptide ions are formed by ESI or MALDI, their charge state, as well as the collision energy, is the main parameter determining the quality of collision-induced dissociation (CID) MS/MS fragmentation spectra of a given peptide. CID-MS/MS spectra of singly charged peptides obtained on a hybrid quadrupole orthogonal time-of-flight mass spectrometer resemble very closely spectra obtained by matrix-assisted laser desorption/ionization post-source decay time-of-flight mass spectrometry (MALDI-PSD-TOFMS). On the other hand, comparison of CID-MS/MS spectra of either singly or doubly charged ion species shows no dependence on whether ions have been formed by ESI or MALDI. This observation confirms that, at the time of precursor ion selection, further mass analysis is effectively decoupled from the desorption/ionization event. Since MALDI ions are predominantly formed as singly charged species and ESI ions as doubly charged, the associated difference in the spectral quality of MS/MS spectra as described here imposes direct consequences on data processing, database searching using ion fragmentation data, and de novo sequencing when ionization techniques are changed.  相似文献   

14.
Laser‐based ionization techniques have demonstrated to be a valuable analytical tool to study organic pigments by mass spectrometric analyses. Though laser‐based ionization techniques have identified several natural and synthetic organic dyes and pigments, they have never been used in the characterization of purple. In this work, positive and negative‐mode laser desorption/ionization mass spectrometry (LDI‐MS) was used for the first time to detect indigoids in shellfish purple. The method was used to study organic residues collected from archaeological ceramic fragments that were known to contain purple, as determined by a classical high‐performance liquid chromatography‐based procedure. LDI‐MS provides a mass spectral fingerprint of shellfish purple, and it was found to be a rapid and successful tool for the identification of purple. In addition, a comparison between positive and negative mode ionization highlighted the complementarity of the two ionization modes. On the one hand, the negative‐ion mode LDI‐MS showed a better selectivity and sensitivity to brominated molecules, such as 6,6'‐dibromoindigo, 6‐monobromoindigo, 6,6'‐dibromoindirubin, 6‐ and 6’‐monobromoindirubin, thanks to their electronegativity, and produced simpler mass spectra. On the other hand, negative‐ion mode LDI‐MS was found to have a lower sensitivity to non‐brominated compounds, such as indigo and indirubin, whose presence can be established in any case by collecting the complementary positive‐ion LDI mass spectrum. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
张珍英  邓慧敏  邓芹英  赵善楷 《分析化学》2003,31(11):1286-1290
采用基质辅助激光解吸电离飞行时间质谱(MAIDI-TOF MS),以2,5-二羟基苯甲酸(DHB)为基体对10种合成的新型双二氮杂萘酮化合物进行了质谱分析,得到了较强的样品准分子离子信号;对校正标样进行了筛选并讨论了标样对测定准确度的影响;研究了样品与金属离子形成加成物的性质。  相似文献   

16.
采用碱性新基质2-氨基-5-硝基噻唑对DNA和蛋白质样品进行了基质辅助激光解吸/电离飞行时间质谱分析.结果表明,2-氨基-5-硝基噻唑能有效地解吸电离DNA和蛋白质样品.采用正离子检测模式,分析分子量小于5000的pd(T)10,pd(C)10,pd(A)8,pd(G)10和pd(5′ATCGATCGAT3′)DNA样品时,分辨率均可达到1万以上;与分析DNA样品的常用基质相比,2-氨基-5-硝基噻唑解吸/电离样品分子所需要的激光强度小,易于获得信噪比和分辨率高及重复性好的谱图;分析蛋白质胰岛素、细胞色素C及牛血清白蛋白样品能达到与α-氰基-4-羟基肉桂酸(HCCA)和3,5-二甲氧基-4-羟基肉桂酸(SA)相同的效果.采用负离子检测模式则能以较高的信噪比获得分子量达到7000的DNA的分子离子峰信号.此外,以2-氨基-5-硝基噻唑为基质的基质辅助激光解吸/电离(MALDI)测定还表现出一定的耐盐能力.  相似文献   

17.
A method to obtain laser desorption/ionization mass spectra of organic compounds by depositing sample solutions onto a carbon substrate surface is demonstrated. The substrate consists of a thin layer of activated carbon particles immobilized on an aluminum support. In common with the porous carbon suspension samples used in previous “surface-assisted laser desorption/ionization” (SALDI) work, the mass spectra contain only a few “matrix” background ion peaks, minimizing interference with analyte ion peaks. The presence of glycerol ensured that the ion signals were stable over hundreds of laser shots. In addition, the carbon substrate surface has several advantages over the suspension samples. The use of a very thin layer of carbon significantly improves the sensitivity. Detection limits range from attomoles for crystal violet to femtomoles for bradykinin. Very little sample preparation is required as the analyte solution is simply pipetted onto the substrate surface and glycerol added. When using an alternate sample deposition method, a mass resolution for bradykinin of 1800 is achieved in linear time-of-flight mode. This is close to the resolution limit set by the detector system and above instrument specification for matrix-assisted laser desorption/ionization mass spectra.  相似文献   

18.
The major and minor products of the reaction of imidazole with bis(iodomethyl)tetramethyldisiloxane have been identified, and their main fragmentation pathways have been determined, by matrix-free nano-assisted laser desorption/ionization mass spectrometry (NALDI TOF/TOF).  相似文献   

19.
Matrix-assisted laser desorption/ionization coupled with time-of-flight mass spectrometry (MALDI/TOF-MS) was used for the analysis of low-molecular phosphate compounds found in Hanford tank wastes. The mass spectra of these compounds indicate protonated peaks as well as sodium adducts. Analytical methods presently utilized for the analysis of the phosphate-related organics are both time consuming and labor intensive. A promising alternative is MALDI/TOFMS. The MALDI process produces both positive and negative ions directly and very little sample is required. In addition, there is limited sample preparation and minimal hazardous waste production.  相似文献   

20.
The identification of pharmacologically promising compounds (lead compounds) from combinatorial libraries is frequently limited by the throughput of the analytical technique employed. Fourier transform mass spectrometry (FTMS) offers high sensitivity, mass accuracy (m/Deltam > 500 000), and sequencing capabilities. A rapid and efficient method for high-throughput analysis of single beads from peptide-encoded combinatorial libraries with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is presented. Encoding peptides on single beads are identified and structurally characterized by MALDI time-of-flight (TOF) and ultrahigh-resolution MALDI Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry. A strategy of on-probe sample preparation is developed to minimize handling of the beads.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号