首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
To study the influence of back feeding particles on gas-solid flow in the riser, this paper investigated the flow asymmetry in the solid entrance region of a fluidized bed by particle concentration/velocity measurements in a cold square circulating fluidized beds (CFB). The pressure drop distribution along the riser and the saturation carrying capacity of gas for Geldart-B type particles were first analyzed. Under the condition of u0 = 4 m/s and Gs = 21 kg/(m^2 s), the back feeding particles were found to penetrate the lean gas-solid flow near the entrance (rear) wall before reaching the opposite (front) wall, thus leading to a relatively denser region near the front wall in the bottom bed. Higher solid circulation rate (u0 =4 m/s, Gs = 33 kg/(m^2 s)) resulted in a higher particle concentration in the riser. However the back feeding particles with higher momentum increased the asymmetry of the particle concentration/velocity profile in the solid entrance region. Lower air velocity (u0 =3.2 m/s) and Gs =21 kg/(m2 s), beyond the saturation carrying capacity of gas, induced an S-shaped axial solid distribution with a denser bottom zone. This limited the penetration of the back feeding particles and forced the flnidizing air to flow in the central region, thus leading to a higher solid holdup near the rear wall. Under the conditions of uo = 4 m/s and Gs = 21 kg/(m^2 s), addition of coarse particles (dp= 1145 μm) into the bed made the radial distribution of solids more symmetrical.  相似文献   

2.
Gas–solid flow in a fluid catalytic cracking (FCC) riser exhibits poor mixing in the form of a core–annulus flow pattern and a dense bottom/dilute top distribution of solids. To enhance gas–solid mixing, studies on dense fluidized beds have suggested using a pulsating flow of gas. The present study investigates the effect of pulsating flow on gas–solid hydrodynamics inside the FCC riser employing computational fluid dynamics. Two flow conditions are investigated: a cold flow of air-FCC catalyst in a pilot-scale riser and a reactive flow in an industrial-scale FCC riser. In the cold-flow riser, pulsating flows cause the slug flow of solids and thus increase the average solid accumulation in the flow domain and solid segregation towards the wall. In the industrial FCC riser, pulsating flows produce radial profiles that are more homogeneous. Pulsating flows further improve the conversion and yield in the initial few metres of height. At 7 m, the conversion from pulsating flow is 59%, compared with 44% in without pulsating flow. The results and analysis presented here will help optimize flow conditions in the circulating fluidized bed riser, in not only FCC but also applications such as fast pyrolysis and combustion.  相似文献   

3.
Solar cracking of methane is considered to be an attractive option due to its CO2 free hydrogen production process. Carbon particle deposition on the reactor window, walls and exit is a major obstacle to achieve continuous operation of methane cracking solar reactors. As a solution to this problem a novel “aero-shielded solar cyclone reactor” was created. In this present study the prediction of particle deposition at various locations for the aero-shielded reactor is numerically investigated by a Lagrangian particle dispersion model. A detailed three dimensional computational fluid dynamic (CFD) analysis for carbon deposition at the reactor window, walls and exit is presented using a Discrete Phase Model (DPM). The flow field is based on a RNG k–ε model and species transport with methane as the main flow and argon/ hydrogen as window and wall screening fluid. Flow behavior and particle deposition have been observed with the variation of main flow rates from 10–20 L/min and with carbon particle mass flow rate of 7 × 10−6 and 1.75 × 10−5 kg/s. In this study the window and wall screening flow rates have been considered to be 1 L/min and 10 L/min by employing either argon or hydrogen. Also, to study the effect of particle size simulations have also been carried out (i) with a variation of particle diameter with a size distribution of 0.5–234 μm and (ii) by taking 40 μm mono sized particles which is the mean value for the considered size distribution. Results show that by appropriately selecting the above parameters, the concept of the aero-shielded reactor can be an attractive option to resolve the problem of carbon deposition at the window, walls and exit of the reactor.  相似文献   

4.
This paper presents the results of an ongoing investigation into transient pressure pulses using Shannon entropy. Pressure fluctuations (produced by gas–solid two-phase flow during fluidized dense-phase conveying) are recorded by pressure transducers installed at strategic locations along a pipeline. This work validates previous work on identifying the flow mode from pressure signals (Mittal, Mallick, & Wypych, 2014). Two different powders, namely fly ash (median particle diameter 45 μm, particle density 1950 kg/m3, loosely poured bulk density 950 kg/m3) and cement (median particle diameter 15 μm, particle density 3060 kg/m3, loosely poured bulk density 1070 kg/m3), are conveyed through different pipelines (51 mm I.D. × 70 m length and 63 mm I.D. × 24 m length). The transient nature of pressure fluctuations (instead of steady-state behavior) is considered in investigating flow characteristics. Shannon entropy is found to increase along straight pipe sections for both solids and both pipelines. However, Shannon entropy decreases after a bend. A comparison of Shannon entropy among different ranges of superficial air velocity reveals that high Shannon entropy corresponds to very low velocities (i.e. 3–5 m/s) and very high velocities (i.e. 11–14 m/s) while low Shannon entropy corresponds to mid-range velocities (i.e. 6–8 m/s).  相似文献   

5.
This paper presents a computational investigation of hydrodynamics, heat transfer and cracking reaction in a heavy oil riser operated in a novel operating mode of low temperature contact and high catalyst-to-oil ratio. Through incorporating feedstock vaporization and a 12-lump cracking kinetics model, a validated gas–solid flow model has been extended to the analysis of the hydrodynamic and reaction behavior in an industrial riser. The results indicate that the hydrodynamics, temperature and species concentration exhibit significantly nonuniform behavior inside the riser, especially in the atomization nozzle region. The lump concentration profiles along the riser height provide useful information for riser optimization. Compared to conventional fluid catalytic cracking (FCC) process, feedstock conversion and gasoline yield are respectively increased by 1.9 units and 1.0 unit in the new FCC process, the yield of liquefied petroleum gas is increased by about 1.0 unit while dry gas yield is reduced by about 0.3 unit.  相似文献   

6.
Numerical simulation of fully developed hydrodynamics of a riser and a downer was carried out using an Eulerian–Lagrangian model, where the particles are modeled by the discrete element method (DEM) and the gas by the Navier–Stokes equations. Periodic flow domain with two side walls was adopted to simulate the fully developed dynamics in a 2D channel of 10 cm in width. All the simulations were carried out under the same superficial gas velocity and solids holdup in the domain, starting with a homogenous state for both gas and solids, and followed by the evolution of the dynamics to the heterogeneous state with distinct clustering in the riser and the downer. In the riser, particle clusters move slowly, tending to suspend along the wall or to flow downwards, which causes wide residence time distribution of the particles. In the downer, clusters still exist, but they have faster velocities than the discrete particles. Loosely collected particles in the clusters move in the same direction as the bulk flow, resulting in plug flow in the downer. The residence time distribution (RTD) of solids was computed by tracking the displacements of all particles in the flow direction. The results show a rather wide RTD for the solids in the riser but a sharp peak RTD in the downer, much in agreement with the experimental findings in the literature. The ensemble average of transient dynamics also shows reasonable profiles of solids volume fraction and solids velocity, and their dependence on particle density.  相似文献   

7.
The possible events during bubble formation on an orifice were investigated using a rectangular bubble column (30 cm × 30 cm × 100 cm). The gas flow rate through a single orifice was adjusted from 0.1 dm3/min to 5.0 dm3/min covering a high flow rate regime. At the high gas flow rate, the bubble formation process was complicated by diverse events, such as wake effect, channeling, and orifice-induced turbulent flow. The detachment period could be used to discern the bubble formation steps because it was strongly affected by the above events. The bubble size distribution around the orifice was also analyzed to gain a clearer understanding of the bubble formation process. Above the rate of 3.0 dm3/min through a single orifice, the detachment period converged to a value of 25 ms irrespective of the orifice diameter. The bubble size distribution also showed little difference in this range of gas flow rate. This could be explained by the development of turbulent flow around the orifice. A 0.15 m in-diameter bubble column was tested to investigate the effect of orifice-induced turbulent flow on the regime transition in which the homogeneous flow regime is converted into the heterogeneous flow regime in the column. Obvious distinction between the orifice- and column-induced transitions was observed.  相似文献   

8.
A thorough review of the available literature has revealed a significant lack of usable data regarding the transport of interfacial area in large diameter channels. This represents a concern for various industrial systems, but especially for predicting the performance of safety systems in nuclear reactor systems. In order to remedy this gap in the current experimental database a series of experiments has been performed. These experiments included the measurement of the local interfacial area concentration and other parameters using local electrical conductivity probes in pipes with diameters of 0.152 m [6 in.], 0.203 m [8 in.] and 0.304 m [12 in.]. Volumetric fluxes ranged up to 2 m/s [6.56 ft/s] for the liquid phase and 10 m/s [32.8 ft/s] for the gas phase, and two nominal pressure conditions of 180 kPa [26.1 psia] and 280 kPa [40.6 psia] were included. Gas was injected as large cap bubbles in order to provide a basis for evaluating models for cap-bubbly flow at low void fractions. Measurements were performed simultaneously at three axial locations to allow the evaluation of interfacial area transport. The resulting data provides valuable insight into the flow structure and behavior in all flow regimes other than annular flow and will serve as a valuable database for the evaluation of models for predicting the transport of interfacial area across a wide variety of flow conditions and pipe sizes.  相似文献   

9.
This paper presents the results of an ongoing investigation into the fluctuations of pressure signals due to solids–gas flows for dense-phase pneumatic conveying of fine powders. Pressure signals were obtained from pressure transducers installed along different locations of a pipeline for the fluidized dense-phase pneumatic conveying of fly ash (median particle diameter 30 μm; particle density 2300 kg/m3; loose-poured bulk density 700 kg/m3) and white powder (median particle diameter 55 μm; particle density 1600 kg/m3; loose-poured bulk density 620 kg/m3) from dilute to fluidized dense-phase. Standard deviation and Shannon entropy were employed to investigate the pressure signal fluctuations. It was found that there is an increase in the values of Shannon entropy and standard deviation for both of the products along the flow direction through the straight pipe sections. However, both the Shannon entropy and standard deviation values tend to decrease after the flow through bend(s). This result could be attributed to the deceleration of particles while flowing through the bends, resulting in dampened particle fluctuation and turbulence. Lower values of Shannon entropy in the early parts of the pipeline could be due to the non-suspension nature of flow (dense-phase), i.e., there is a higher probability that the particles are concentrated toward the bottom of pipe, compared with dilute-phase or suspension flow (high velocity), where the particles could be expected to be distributed homogenously throughout the pipe bore (as the flow is in suspension). Changes in straight-pipe pneumatic conveying characteristics along the flow direction also indicate a change in the flow regime along the flow.  相似文献   

10.
An experimental investigation was carried out on viscous oil–gas flow characteristics in a 69 mm internal diameter pipe. Two-phase flow patterns were determined from holdup time-traces and videos of the flow field in a transparent section of the pipe, in which synthetic commercial oils (32 and 100 cP) and sulfur hexafluoride gas (SF6) were fed at oil superficial velocities from 0.04 to 3 m/s and gas superficial velocities from 0.0075 to 3 m/s.  相似文献   

11.
A computational fluid dynamics (CFD) modeling of the gas–solids two-phase flow in a circulating fluidized bed (CFB) riser is carried out. The Eularian–Eularian method with the kinetic theory of granular flow is used to solve the gas–solids two-phase flow in the CFB riser. The wall boundary condition of the riser is defined based on the Johnson and Jackson wall boundary theory (Johnson & Jackson, 1987) with specularity coefficient and particle–wall restitution coefficient. The numerical results show that these two coefficients in the wall boundary condition play a major role in the predicted solids lateral velocity, which affects the solid particle distribution in the CFB riser. And the effect of each of the two coefficients on the solids distribution also depends on the other one. The generality of the CFD model is further validated under different operating conditions of the CFB riser.  相似文献   

12.
In this study, experiments on fly ash conveying were carried out with a home-made long-distance positive-pressure pneumatic conveying system equipped with a high performance electrical capacitance tomography system to observe the transient characteristics of gas–solid two-phase flow. The experimental results indicated that solids throughput increased with increasing solids–gas ratio when the conveying pipeline was not plugged. Moreover, the optimum operating state was determined for the 1000 m long conveying pipeline with a throttle plate of 26 orifices. At this state the solids throughput was about 12.97 t/h. Additionally, the transportation pattern of fly ash gradually changed from sparse–dense flow to partial and plug flows with increasing conveying distance because of the conveying pressure loss. These experimental results provide important reference data for the development of pneumatic conveying technology.  相似文献   

13.
Pressure drops in the flow through micro-orifices and capillaries were measured for silicone oils, aqueous solutions of polyethylene glycol (PEG), and surfactant aqueous solutions. The diameter of micro-orifices ranged from 5 μm to 400 μm. The corresponding length/diameter ratio was from 4 to 0.05 and capillary diameters were 105 μm and 450 μm. The following results were obtained: silicone oils of 10?6 m2/s and 10?5 m2/s in kinematic viscosity generated a reduction of pressure drop (RPD), that is, drag reduction, similar to the RPD of water and a glycerol/water mixture reported in the previous paper by the present authors. When RPD occurred, the pressure drop (PD) of silicone oils of 10?6 m2/s and 10?5 m2/s had nearly the same magnitude. Namely, the difference in viscosity did not influence RPD. A 103 ppm aqueous solution of PEG20000 provided almost the same PD as that of PEG8000 for the 400 μm to 15 μm orifices, but a greater PD than that of PEG8000 for the 10 μm to 5 μm orifices. A non-ionic surfactant and a cationic surfactant were highly effective in RPD compared with anionic surfactants: the non-ionic and cationic surfactant solutions had PD one order of magnitude lower than that of water under some flow conditions in the concentration range from 1 ppm to 104 ppm, but the anionic surfactant solutions did not generate RPD except in the case of the smallest orifice of 5 μm in diameter. The PD of the non-ionic surfactant solution showed a steep rise at a Reynolds number (Ret) for 400 μm to 15 μm orifices. The Ret provides the relationship Ret = K/D, where D is the orifice diameter, and K is a constant of 2 × 10?2 m for the 100–20 μm orifices irrespective of liquid concentration. Capillary flow experiment revealed that the PEG, non-ionic and cationic surfactant solutions generated RPD also in a laminar flow through the capillary of 105 μm in diameter, but not in the flow through the capillary of 450 μm in diameter. In order to clarify the cause of RPD, an additional experiment was carried out by changing the orifice material from metal to acrylic resin. The result gave a different appearance of RPD, suggesting that RPD is related to an interfacial phenomenon between the liquid and wall. The large RPDs found in the present experiment are very interesting from both academic and practical viewpoints.  相似文献   

14.
Severe slugging is a dynamic two-phase flow phenomenon with regular liquid accumulation and blow-out in flow-line riser geometries. This paper discusses the applicability of a slug tracking model on a case where hydrodynamic slug initiation in a horizontal part of the pipeline upstream the riser base affects the severe slugging cycle period. The given experimental case is from the Shell laboratories in Amsterdam: air–water flow in a 100 m long pipe (65 m horizontal and 35 m −2.54° downwards) followed by a 15 m long vertical riser.A Lagrangian slug and bubble tracking model is described. A two-fluid model is applied in the bubble region and the slug region is treated as incompressible flow, with an integral momentum equation. Slug initiation from unstable stratified flow can be captured directly by solving the two-fluid model on a fine grid (a hybrid capturing and tracking scheme). Alternatively, slug initiation can be made from sub grid models, allowing for larger grid sizes. The sub grid models are based on the two established flow regime transition criteria derived from the stability of stratified flow and from the limiting solution of the unit cell slug flow model.Sensitivity studies on hydrodynamic slug initiation models on the severe slugging characteristics are presented. No hydrodynamic slug initiation (e.g. large grid size in the capturing scheme) overestimates the severe slug period compared with the experiments. Slug capturing and sub grid initiation models both give good predictions for small grid sizes (provided the detailed inlet configuration is included in the capturing case). Good predictions are also shown for larger grid sizes (factor of 50) and sub grid initiation models.The numerical tests show that correct prediction of the severe slugging cycle is sensitive to the initiation of upstream hydrodynamic slugs, but less sensitive to the local structure of the slug flow (frequencies and lengths) in the upstream region.  相似文献   

15.
To study axial/radial profiles of particle velocity in the affected region of an integrated riser outlet, a cold model was developed for the integrated riser reactor combining the gas–solid distributor with the fluidized bed. Constraints, related to the gas–solid distributor and the upper fluidized bed, imposed on the particle flow in the riser outlet region, were investigated experimentally. The experimental results showed that with increasing superficial gas velocity, these constraints have strong influences on particle flow behavior, the particle circulation flux in the riser, and the height of the static bed material of the upper fluidized bed. When the constraints have greater prominence, the axial profile of the cross-sectionally averaged particle velocity in the outlet region initially increases and then decreases, the rate of decrease being proportional to the constraint strength. Along the radial direction of the outlet section, the region where the local particle velocity profile tends to decrease appears near the dimensionless radius r/R = 0.30 initially and then, with increasing constraint strength, gradually extends to the whole section from the inner wall. Based on the experimental data, an empirical model describing the constraint strength was established. The average relative error of the model is within 7.69%.  相似文献   

16.
Two-phase oil–water flow was studied in a 15 m long horizontal steel pipe, with 8.28 cm internal diameter, using mineral oil (having 830 kg/m3 density and 7.5 mPa s viscosity) and brine (1073 kg/m3 density and of 0.8 mPa s viscosity). Measurements of the holdup and of the cross-sectional phase fraction distribution were obtained for stratified flow and for highly dispersed oil–water flows, applying a capacitive Wire-Mesh Sensor specially designed for that purpose. The applicability of this measurement technique, which uses a circuit for capacitive measurements that is adapted to conductive measurements, where one of the fluids is water with high salinity (mimicking sea water), was assessed. Values for the phase fraction values were derived from the raw data obtained by the Wire-Mesh Sensor using several mixture permittivity models. Two gamma-ray densitometers allowed the accurate measurement of the holdups, which was used to validate the data acquired with the capacitive Wire-Mesh Sensor. The measured time-averaged distribution of the phase fraction over the cross-sectional area was used to investigate the details of the observed two-phase flow patterns, including the interface shape and water height. The experiments were conducted in the multiphase-flow test facility of Shell Global International B.V. in the Netherlands.  相似文献   

17.
This paper proposes a new method for equal quality distribution of gas–liquid two-phase flow by partial separate-phase distribution with a dual-header distributor. The upper and liquid (lower) headers are interconnected with five vertical downward arms. A gas–liquid two-phase mixture enters the distributor from the upper header where most of the liquid of the mixture is removed through the downward arms into the liquid header. Hence, firstly, the remaining gas-rich fluid can be uniformly distributed into the outlet branches, and then secondly, the liquid collected in the liquid header can be uniformly re-distributed into the individual outlet branches. Because both distribution processes are conducted in the condition of single or near single-phase flow, mal-distribution of the two-phase flow is essentially eliminated, and a satisfactory equal quality distribution of gas–liquid two-phase flow is reached. Experiments were conducted in an air–water two-phase flow test loop. The inner diameter of the inlet pipe was 60 mm, the superficial velocity ranges of gas and liquid were 3–32 m/s and 0.02–0.17 m/s respectively, and the quality ranged from 0.02 to 0.44. The flow pattern in the inlet pipe included stratified flow, wavy stratified, slug flow, and annular flow. The experimental results showed that this new method could significantly improve the distribution performance of the two-phase flow. The maximum quality deviation between each outlet branch and the inlet pipe is less than ±1% under the conditions of stratified, wavy stratified and slug flows in the upper header, and less than ±5% in annular flow.  相似文献   

18.
A computational fluid dynamics (CFD) model is used to investigate the hydrodynamics of a gas–solid fluidized bed with two vertical jets. Sand particles with a density of 2660 kg/m3 and a diameter of 5.0 × 10?4 m are employed as the solid phase. Numerical computation is carried out in a 0.57 m × 1.00 m two-dimensional bed using a commercial CFD code, CFX 4.4, together with user-defined Fortran subroutines. The applicability of the CFD model is validated by predicting the bed pressure drop in a bubbling fluidized bed, and the jet detachment time and equivalent bubble diameter in a fluidized bed with a single jet. Subsequently, the model is used to explore the hydrodynamics of two vertical jets in a fluidized bed. The computational results reveal three flow patterns, isolated, merged and transitional jets, depending on the nozzle separation distance and jet gas velocity and influencing significantly the solid circulation pattern. The jet penetration depth is found to increase with increasing jet gas velocity, and can be predicted reasonably well by the correlations of Hong et al. (2003) for isolated jets and of Yang and Keairns (1979) for interacting jets.  相似文献   

19.
The hydrodynamics and energy consumption have been studied in a cold flow, bubbling and turbulent, pressurized gas–liquid–solid three-phase fluidized bed (0.15 m ID × 1 m height) with concurrent gas–liquid up flow is proposed with the intention of increasing the gas hold up. The hydrodynamic behaviour is described and characterised by some specific gas and liquid velocities. Particles are easily fluidized and can be uniformly distributed over the whole height of the column. The effect of parameters like liquid flow rate, gas flow rate, particle loading, particle size, and solid density on gas hold up and effect of gas flow rate, solid density and particle size on solid hold up, energy consumption and minimum fluidization velocity has been studied. At the elevated pressures a superior method for better prediction of minimum fluidization velocity and terminal settling velocities has been adopted. The results have been interpreted with Bernoulli’s theorem and Richardson–Zaki equation. Based on the assumption of the gas and liquid as a pretend fluid, a simplification has been made to predict the particle terminal settling velocities. The Richardson–Zaki parameter n′ was compared with Renzo’s results. A correlation has been proposed with the experimental results for the three-phase fluidization.  相似文献   

20.
Oil–water two-phase flow experiments were conducted in horizontal ducts made of Plexiglas® to determine the in situ oil fraction (holdup) by means of the closing valves technique, using mineral oil (viscosity: 0.838 Pa s at 20 °C; density: 890 kg m−3) and tap water. The ducts present sudden contractions from 50 mm to 40 mm i.d. and from 50 mm to 30 mm i.d., with contraction ratios of 0.64 and 0.36, respectively. About 200–320 tests were performed by varying the flow rates of the phases. Flow patterns were investigated for both the up- and downstream pipe in order to assess whether relevant variations of the flow patterns across the sudden contraction take place. Data were then compared with predictions of a specific correlation for oil–water flow and some correlations for gas–water flow. A drift-flux model was also applied to determine the distribution parameter.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号