首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The filtration performance of the moving bed granular filter with axial flow (MBGF-AF) is investigated through a large cold experiment. The effect of different operation parameters on the filtration performance (collection efficiency, pressure drop) of the axial-flow moving bed filter is investigated in combination with the dust deposition effect and the mechanism of trapping dust by the capturing particles. The results show that the collection efficiency of MBGF-AF is enhanced by decreasing the superficial gas velocity, increasing the inlet dust concentration properly, or decreasing the moving velocity of the capturing particles. A model covering the above operation parameters is established to calculate the collection efficiency of the moving bed granular filter. It is used in a wide range of operating parameters for the MBGFs.  相似文献   

2.
A magnetically stabilized fluidized bed (MSFB, φ 500mm x 2100mm) was designed to study dust removal from flue gas. Based on the mechanism of dust removal in a fixed bed, the effects on collection efficiency of magnetic field intensity, ratio of flue gas velocity to minimum fluidization velocity, bed height, and particle average diameter, were investigated. Then feasible methods for MSFB to better remove dust were proposed. Over 95% of dust removal with MSFB can be achieved, when stable fluidization is maintained and when magnetic particles are frequently renewed.  相似文献   

3.
In this article, a standard 2D Two-Fluid Model (TFM) closed by the kinetic theory of granular flow (KTGF) has been applied to simulate the behavior of tapered-in and tapered-out fluidized bed reactors. In this regard, two types of chemical reactions with gas volume reduction and increase were considered to investigate the effects of initial static bed height on the fractional conversion and bed pressure drop. To validate the CFD model predictions, the results of hydrodynamic simulations concerning bed pressure drop and bed expansion ratio were compared against experimental data reported in the literature and excellent agreement was observed. The obtained simulation results clearly indicate that there is an appropriate static bed height in a tapered-in reactor in which the fractional conversion becomes maximum at this height; whereas variations of static bed height in a tapered-out reactor have insignificant influences on the fractional conversion. Moreover, it was found that the residence time, temperature, and intensity of turbulence of the gas phase are three important factors affecting the fractional conversion in tapered fluidized bed reactors. In addition, it was observed that increasing the static bed height increases the bed pressure drop for both the tapered-in and tapered-out fluidized bed reactors.  相似文献   

4.
Hydrodynamic characteristics of fluidization in a conical or tapered bed differ from those in a columnar bed because the superficial velocity in the bed varies in the axial direction. Fixed and fluidized regions could coexist and sharp variations in pressure drop could occur, thereby giving rise to a noticeable pressure drop-flow rate hysteresis loop under incipient fluidization conditions. To explore these unique properties, several experiments were carried out using homogeneous, well-mixed, ternary mixtures with three dif- ferent particle sizes at varying composition in gas-solid conical fluidized beds with varying cone angles. The hydrodynamic characteristics determined include the minimum fluidization velocity, bed fluctuation, and bed expansion ratios. The dependence of these quantities on average particle diameter, mass fraction of the fines in the mixture, initial static bed height, and cone angle is discussed. Based on dimensional analysis and factorial design, correlations are developed using the system parameters, i.e. geometry of the bed (cone angle), particle diameter, initial static bed height, density of the solid, and superficial velocity of the fluidizing medium. Experimental values of minimum fluidization velocity, bed fluctuation, and bed expansion ratios were found to agree well with the developed correlations.  相似文献   

5.
Accurate information concerning riser inventory in a fluidized bed is required in some applications such as the calcium looping process,because it is related to the CO_2 capture efficiency of the system.In a circulating fluidized bed(CFB),the riser inventory is normally calculated from the riser pressure drop;however,the friction and the acceleration phenomena may have a significant influence on the total riser pressure drop.Therefore,deviation may occur in the calculation from the actual mass.For this reason the magnitude of the friction and the acceleration pressure drop in the entire riser is studied in small-scale risers.Two series of studies were performed:the first one in a scaled cold model riser of the 10 kW_(th)facility,and the second one in the 10kW_(th) fluidized bed riser under process conditions.The velocities were chosen to comply with the fluidization regimes suitable for the calcium looping process,namely,the turbulent and the fast.In cold-model experiments in a low-velocity turbulent fluidization regime,the actual weight(static pressure drop) of the particles is observed more than the weight calculated from a recorded pressure drop.This phenomenon is also repeated in pilot plant conditions.In the cold-model setup,the friction and acceleration pressure drop became apparent in the fast fluidization regime,and increased as the gas velocity rose.Within calcium looping conditions in the pilot plant operation,the static pressure drop was observed more than the recorded pressure drop.Therefore,as a conservative approach,the influence of friction pressure drop may be neglected while calculating the solid inventory of the riser.The concept of transit inventory is introduced as a fraction of total inventory,which lies in freefall zones of the CFB system.This fraction increases as gas velocity rises.  相似文献   

6.
The magnetized fluidized bed (MFB) with Geldart-B particles exhibits many distinct flow regimes depending on the magnetic field intensity (H) and gas velocity (Ug). The identification of these regimes was reviewed for the MFB with magnetizable particles and that with binary admixture of magnetizable and nonmagnetizable particles. Meanwhile, methods for determining the boundaries between two adjacent flow regimes were clarified. The MFB state was found to depend not only on H and Ug but also on their application sequence (i.e., operation mode) within certain operating zones. The dependence feature arose from that the MFB therein could have different equilibrium states for the same combination of H and Ug. Furthermore, such a polymorphic characteristic of the MFB was revealed to result from the internal friction among the particles that were in unfluidized/packed state. Many of the MFB states were demonstrated to be in metastable equilibrium. Nevertheless, they differed significantly from the metastates well-known in the discipline of physical chemistry, such as supercooling and superheated. In fact, they belonged to the amorphous/glass state. This review will deepen our hydrodynamic understanding of the MFB and further promote its commercial application in the chemical and biochemical industries.  相似文献   

7.
Removal of dust from flue gas in magnetically stabilized fluidized bed   总被引:1,自引:0,他引:1  
A magnetically stabilized fluidized bed (MSFB,Ф 500mm×2100mm) was designed to study dust removal from flue gas. Based on the mechanism of dust removal in a fixed bed, the effects on collection efficiency of magnetic field intensity, ratio of flue gas velocity to minimum fluidization velocity, bed height, and particle average diameter, were investigated. Then feasible methods for MSFB to better remove dust were proposed. Over 95 % of dust removal with MSFB can be achieved, when stable fluidization is maintained and when magnetic particles are frequently renewed.  相似文献   

8.
Accurate information concerning riser inventory in a fluidized bed is required in some applications such as the calcium looping process, because it is related to the CO2 capture efficiency of the system. In a circulating fluidized bed (CFB), the riser inventory is normally calculated from the riser pressure drop; however, the friction and the acceleration phenomena may have a significant influence on the total riser pressure drop. Therefore, deviation may occur in the calculation from the actual mass. For this reason the magnitude of the friction and the acceleration pressure drop in the entire riser is studied in small-scale risers. Two series of studies were performed: the first one in a scaled cold model riser of the 10 kWth facility, and the second one in the 10 kWth fluidized bed riser under process conditions. The velocities were chosen to comply with the fluidization regimes suitable for the calcium looping process, namely, the turbulent and the fast. In cold-model experiments in a low-velocity turbulent fluidization regime, the actual weight (static pressure drop) of the particles is observed more than the weight calculated from a recorded pressure drop. This phenomenon is also repeated in pilot plant conditions. In the cold-model setup, the friction and acceleration pressure drop became apparent in the fast fluidization regime, and increased as the gas velocity rose. Within calcium looping conditions in the pilot plant operation, the static pressure drop was observed more than the recorded pressure drop. Therefore, as a conservative approach, the influence of friction pressure drop may be neglected while calculating the solid inventory of the riser. The concept of transit inventory is introduced as a fraction of total inventory, which lies in freefall zones of the CFB system. This fraction increases as gas velocity rises.  相似文献   

9.
Some hydrodynamic aspects of 3-phase inverse fluidized bed   总被引:2,自引:0,他引:2  
Hydrodynamics of 3-phase inverse fluidized bed is studied experimentally using low density particles for different liquid and gas velocities. The hydrodynamic characteristics studied include pressure drop, minimum liquid and gas fluidization velocities and phase holdups. The minimum liquid fluidization velocity determined using the bed pressure gradient, decreases with increase in gas velocity. The axial profiles of phase holdups shows that the liquid holdup increases along the bed height, whereas the solid holdup decreases down the bed. However, the gas holdup is almost uniform in the bed.  相似文献   

10.
The dynamic characteristics of a gas-solid fluidized bed with different rod promoters have been investigated in terms of bed expansion and fluctuation, minimum fluidization velocity and distributor-to-bed pressure drop ratio at minimum fluidization velocity. Experimentation based on statistical design has been carried out and model equations using factorial design of experiments have been developed for the above mentioned quantities for a promoted gas-solid fluidized bed. The model equations have been tested with additional experimental data. The system variables include four types of rod promoters of varying blockage volume, bed particles of four sizes and four initial static bed heights. A comparison between the predicted values of the output variables using the proposed model equation with their corresponding experimental ones shows fairly good agreement.  相似文献   

11.
The present paper describes the statistical modeling and optimization of a multistage gas-solid fluidized bed reactor for the control of hazardous pollutants in flue gas.In this work,we study the hydrodynamics of the pressure drop and minimum fluidization velocity.The hydrodynamics of a three-stage fluidized bed are then compared with those for a single-stage unit.It is observed that the total pressure drop over all stages of the three-stage fluidized bed is less than that of an identical single-stage system.However,the minimum fluidization velocity is higher in the single-stage unit.Under identical conditions,the minimum fluidization velocity is highest in the top bed,and lowest in the bottom bed.This signifies that the behavior of solids changes from a well-mixed flow to a plug-flow,with intermediate behavior in the middle bed.  相似文献   

12.
The development of a theoretical model for the prediction of velocity and pressure drop for the flow of a viscous power law fluid through a bed packed with uniform spherical particles is presented. The model is developed by volume averaging the equation of motion. A porous microstructure model based on a cell model is used. Numerical solution of the resulting equation is effected using a penalty Galerkin finite element method. Experimental pressure drop values for dilute solutions of carboxymethylcellulose flowing in narrow tubes packed with uniformly sized spherical particles are compared to theoretical predictions over a range of operating conditions. Overall agreement between experimental and theoretical values is within 15%. The extra pressure drop due to the presence of the wall is incorporated directly into the model through the application of the no-slip boundary condition at the container wall. The extra pressure drop reaches a maximum of about 10% of the bed pressure drop without wall effect. The wall effect increases as the ratio of tube diameter to particle diameter decreases, as the Reynolds number decreases and as the power law index increases.  相似文献   

13.
Acetone hydrogenation in a fixed bed reactor packed with spherical catalyst particles was simulated to study the effects of inlet gas velocity and particle diameter on hydrogenation reaction. Computational results show that the catalyst particles in the reactor are almost isothermal, and the high isopropanol concentration appears at the lee of the particles. With the increase of inlet velocity, the outlet isopropanol mole fraction decreases, and the total pressure drop increases drastically. Small diameter catalyst particles are favorable for acetone hydrogenation, but result in large pressure drop.  相似文献   

14.
Three-phase fluidized beds are found to have wide applications in process industries. The present investigation essentially comprises of the studies on gas holdup, liquid holdup and bed porosity in three-phase fluidized beds with coaxially placed disc promoter. Holdup data were obtained from bed expansion and pressure drop measurements. Analysis of the data was done to elucidate the effects of dynamic and geometric parameters on gas holdup, liquid holdup and bed porosity. Data were correlated and useful equations were obtained from empirical modeling.  相似文献   

15.
An experimental study was made of the thermal and hydraulic characteristics of a three-phase fluidized bed cooling tower. The experiments were carried out in a packed tower of 200 mm diameter and 2.5 m height. The packing used was spongy rubber balls 12.7 mm in diameter and with a density of 375 kg/m3. The tower characteristic was evaluated. The air-side pressure drop and the minimum fluidization velocity were measured as a function of water/air mass flux ratio (0.4–2), static bed height (300–500 mm), and hot water inlet temperature (301–334 K).

The experimental results indicate that the tower characteristics KaV/L increases with increases in the bed static height and hot water inlet temperature and with decreases in the water/air mass flux ratio. It is also shown that the air-side pressure drop increases very slowly with increases in air velocity. The minimum, fluidization velocity was found to be independent of the static bed height.

The data obtained were used to develop a correlation between the tower characteristics, hot water inlet temperature, static bed height, and the water/air mass flux ratio. The mass transfer coefficient of the three-phase fluidized bed cooling tower is much higher than that of packed-bed cooling towers with higher packing height.  相似文献   


16.
The effects of magnetic fields on improving the mass transfer in flue gas desulfurization using a fluidized bed are investigated in the paper. In this research, the magnetically fluidized bed (MFB) is used as the reactor in which ferromagnetic particles are fluidized with simulated flue gas under the influence of an external magnetic field. Lime slurry is continuously sprayed into the reactor. As a consequence, the desulfurization reaction and the slurry drying process take place simultaneously in the MFB. In this paper, the effects of ferromagnetic particles and external magnetic fields on the desulphurization efficiency are studied and compared with that of quartz particles as the fluidized particles. Experimental results show that the ferromagnetic particles not only act as a platform for lime slurry to precipitate on like quartz particles, but also take part in the desulfurization reaction. The results also show that the specific surface area of ferromagnetic particles after reaction is enlarged as the magnetic intensity increases, and the external magnetic field promotes the oxidation of S(IV), improving the mass transfer between sulphur and its sorbent. Hence, the efficiency of desulphurization under the effects of external magnetic fields is higher than that in general fluidized beds.  相似文献   

17.
The hydrodynamic and heat transfer behavior of a bed consisting of magnetic and shale oil particle admixtures under the effect of a transverse magnetic field is investigated. The phase diagram, bed void fraction are studied under wide range of the operating conditions i.e., gas velocity, magnetic field intensity and fraction of the magnetic particles. It is found that the range of the stabilized regime is reduced as the magnetic fraction decreases. In addition, the bed voidage at the onset of fluidization decreases as the magnetic fraction decreases. On the other hand, Nusselt number and consequently the heat transfer coefficient is found to increase as the magnetic fraction decreases. An empirical equation is investigated to relate the effect of the gas velocity, magnetic field intensity and fraction of the magnetic particles on the heat transfer behavior in the bed.  相似文献   

18.
The hydrodynamic characteristics of a rectangular gas-driven inverse liquid-solid fluidized bed (GDFB) using particles of different diameters and densities were investigated in detail. Rising gas bubbles cause a liquid upflow in the riser portion, enabling a liquid downflow that causes an inverse fluidization in the downer portion. Four flow regimes (fixed bed regime, initial fluidization regime, complete fluidization regime, and circulating fluidization regime) and three transition gas velocities (initial fluidization gas velocity, minimum fluidization gas velocity, and circulating fluidization gas velocity) were identified via visual observation and by monitoring the variations in the pressure drop. The axial local bed voidage (ε) of the downer first decreases and then increases with the increase of the gas velocity. Both the liquid circulation velocity and the average particle velocity inside the downer increase with the increase of the gas velocity in the riser, but decrease with the particle loading. An empirical formula was proposed to successfully predict the Richardson-Zaki index “n”, and the predicted ε obtained from this formula has a ±5% relative error when compared with the experimental ε.  相似文献   

19.
1. Introduction The design of gas distributor has a major influence on gas flow patterns, dumping and dead zones. It has been demonstrated that maldistribution will occur if the distribu-tor has a low pressure drop, that is, some parts of the bed will receive much less gas than others, and may be tem-porarily or permanently defluidized, while the gas forms semi-permanent spouts or channels in other parts. There-fore, maldistribution is undesirable in industry. For example, the temperature in a…  相似文献   

20.
Fluidization data acquired, processed and printed out inone integral instrument: pressure drop versus gas velocity fluctuating height versus gas velocity minimum fluidization velocity quality of fluidization expressed in terms of bed collapsing curves: rate of bubble escape rate of particulate sedimentation in dense phase rate of consolidation of packed solids printout of dimensionless subsidence time  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号