首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The condensation heat transfer coefficients of R-22, R-134a and R-410A in a single circular microtube were investigated experimentally. The experiments are conducted without oil in the refrigerant loop. The test section is a smooth, horizontal copper tube of 1.77 mm inner diameter. The experiments were conducted at mass flux of 450-1050 kg/m2 s, saturation temperature of 40 °C. The test results showed that in case of single-phase flow, the single-phase Nusselt Number measured by experimental data was higher than that calculated by Gnielinski correlation. In case of two-phase flow, the condensation heat transfer coefficient of R-410A was higher than that of R-22 and R-134a at the given mass flux. The condensation heat transfer coefficient of R-22 showed almost a similar value to that of R-134a. Most of the existing correlations which were proposed in the large diameter tube failed to predict condensing heat transfer. And also, recently proposed correlation in the single circular microtube is considered not adequate for small diameter tube. Therefore, it is necessary to develop accurate and reliable correlation to predict heat transfer characteristics in the single circular microtube.  相似文献   

2.
The flow boiling heat transfer characteristics of R134a in the multiport minichannel heat exchangers are presented. The heat exchanger was designed as the counter flow tube-in-tube heat exchanger with refrigerant flowing in the inner tube and hot water in the gap between the outer and inner tubes. Two inner tubes were made from extruded multiport aluminium with the internal hydraulic diameter of 1.1 mm for 14 numbers of channels and 1.2 mm for eight numbers of channels. The outer surface areas of two inner test sections are 5979 mm2 and 6171 m2, while the inner surface areas are 13,545 mm2 and 8856 mm2 for 14 and eight numbers of channels, respectively. The outer tube of heat exchanger was made from circular acrylic tube with an internal hydraulic diameter of 25.4 mm. The experiments were performed at the heat fluxes between 15 and 65 kW/m2, mass flux of refrigerant between 300 and 800 kg/m2 s and saturation pressure ranging from 4 to 6 bar. For instance the boiling curve, average heat transfer coefficients are discussed. The comparison results of two test sections with different the number of channels are investigated. The results are also compared with nine existing correlations. The new correlation for predicting the heat transfer coefficient was also proposed.  相似文献   

3.
A theoretical study of forced convective film condensation inside vertical tubes is presented. We propose a unified procedure for predicting the pressure gradient and condensation heat transfer coefficient of a vapor flowing turbulently in the core and associated with laminar or turbulent film on the tube wall. The analysis for the vapor flows is performed under the condition that the velocity profiles are locally self-similar. The laminar and turbulent film models equate the gravity, pressure and viscous forces, and consider the effect of interfacial shear. The transition from laminar to turbulent film depends not only on the liquid Reynolds number but also on the interfacial shear stress. In this work we also proposed a new eddy viscosity model which is divided into three regions: the inner region in liquid condensate near the wall; the interface region including both liquid and vapor; and the outer region for the vapor core. Comparisons of the theory with some published experimental data showed good agreement.  相似文献   

4.
The condensation heat transfer of pure refrigerants, R-22, R-134a and a binary refrigerant R-410A flowing in small diameter tubes was investigated experimentally. The condenser is a countflow heat exchanger which refrigerant flows in the inner tube and cooling water flows in the annulus. The heat exchanger is smooth, horizontal copper tube of 1.77, 3.36 and 5.35 mm inner diameter, respectively. The length of heat exchanger is 1220, 2660 and 3620 mm, respectively. The experiments were conducted at mass flux of 200–400 kg/m2 s and saturation temperature of 40°C. The main results were summarized as follows: in case of single-phase flow, the single-phase Nusselt Number measured by experimental data was higher than that calculated by Gnielinski and Wu and Little correlation. The new single-phase correlation based on the experimental data was proposed in this study. In case of two-phase flow, the condensation heat transfer coefficient of R-410A for three tubes was slightly higher than that of R-22 and R-134a at the given mass flux. The condensation heat transfer coefficient of R-22 showed almost a similar value to that of R-134a. The condensation heat transfer coefficient for R-22, R-134a and R-410A increased with increasing mass flux and decreasing tube diameter. Most of the existing correlations which were proposed in the large diameter tube failed to predict condensation heat transfer. Therefore, the new condensation heat transfer correlation based on the experimental data was proposed in the present study.  相似文献   

5.
A mathematical model based on the annular flow pattern is developed to simulate the evaporation of refrigerants flowing under varied heat flux in a double tube evaporator. The finite difference form of governing equations of this present model is derived from the conservation of mass, energy and momentum. The experimental set-up is designed and constructed to provide the experimental data for verifying the simulation results. The test section is a 2.5 m long counterflow double tube heat exchanger with a refrigerant flowing in the inner tube and heating water flowing in the annulus. The inner tube is made from smooth horizontal copper tubing of 9.53 mm outer diameter and 7.1 mm inner diameter. The agreement of the model with the experimental data is satisfactory. The present model can be used to investigate the axial distributions of the temperature, heat transfer coefficient and pressure drop of various refrigerants. Moreover, the evaporation rate or the other relevant parameters that is difficult to measure in the experiment are predicted and presented here. The results from the present mathematical model show that the saturation pressure and temperature of refrigerant decrease along the tube due to the tube wall friction and the flow acceleration of refrigerant. The liquid heat transfer coefficient increases with the axial length due to reducing the thickness of the liquid refrigerant film. Due to increase of the liquid heat transfer coefficient, increasing wall heat flux is obtained.Finally, the evaporation rate of refrigerant increases with increasing wall heat flux.  相似文献   

6.
A heated horizontal heat transfer tube was installed 14.8 cm above the distributor plate in a square fluid bed measuring 30.5 × 30.5 cm. Four different Geldart B sized particle beds were used (sand of two different distributions, an abrasive and glass beads) and the bed was fluidized with cold air. The tube was instrumented with surface thermocouples around half of the tube circumference and with differential pressure ports that can be used to infer bubble presence. Numerical execution of the transient conduction equation for the tube allowed the local time-varying heat transfer coefficient to be extracted. Data confirm the presence of the stagnant zone on top of the tube associated with low superficial velocities. Auto-correlation of thermocouple data revealed bubble frequencies and the cross-correlation of thermal and pressure events confirmed the relationship between the bubbles and the heat transfer events. In keeping with the notion of a “Packet renewal” heat transfer model, the average heat transfer coefficient was found to vary in sympathy with the root-mean square amplitude of the transient heat transfer coefficient.  相似文献   

7.
The condensation heat transfer characteristics for CO2 flowing in a horizontal microfin tube were investigated by experiment with respect to condensation temperature and mass flux. The test section consists of a 2,400?mm long horizontal copper tube of 4.6?mm inner diameter. The experiments were conducted at refrigerant mass flux of 400–800?kg/m2s, and saturation temperature of 20–30?°C. The main experimental results showed that annular flow was highly dominated the majority of condensation flow in the horizontal microfin tube. The condensation heat transfer coefficient increases with decreasing saturation temperature and increasing mass flux. The experimental data were compared against previous heat transfer correlations. Most correlations failed to predict the experimental data. However, the correlation by Cavallini et al. showed relatively good agreement with experimental data in the microfin tube. Therefore, a new condensation heat transfer correlation is proposed with mean and average deviations of 3.14 and ?7.6?%, respectively.  相似文献   

8.
A mass transfer measuring method based on absorption, chemical and coupled colour reaction is used to visualize and determine the shell side local heat transfer in the first baffle compartment of shell-and-tube heat exchangers with segmental baffles for staggered tube arrangement. Local mass transfer coefficients were transformed into heat transfer coefficients by using the analogy between heat and mass transfer. The local, per-tube and integral heat transfer coefficient distributions are presented.  相似文献   

9.
In this study, experimental and simulation studies of the evaporation heat transfer coefficient and pressure drop of R-134a flowing through corrugated tubes are conducted. The test section is a horizontal counter-flow concentric tube-in-tube heat exchanger 2.0 m in length. A smooth tube and corrugated tubes with inner diameters of 8.7 mm are used as the inner tube. The outer tube is made from a smooth copper tube with an inner diameter of 21.2 mm. The corrugation pitches used in this study are 5.08, 6.35, and 8.46 mm. Similarly, the corrugation depths are 1, 1.25, and 1.5 mm, respectively. The results show that the maximum heat transfer coefficient and pressure drop obtained from the corrugated tube are up to 22 and 19 % higher than those obtained from the smooth tube, respectively. In addition, the average difference of the heat transfer coefficient and pressure drop between the simulation model and experimental data are about 10 and 15 %, respectively.  相似文献   

10.
An experimental study was carried out to investigate condensation heat transfer and pressure drop characteristics of R-134a in a coiled double tube oriented with its helix axis in the vertical direction. Measurements were obtained at inlet pressure of 815 kPa for refrigerant mass flux ranging from 95 to 710 kg/m2s and cooling water Reynolds number varying from 1000 to 14000. Presented results illustrate the effects of refrigerant mass flux and average condensation temperature difference on the condensation heat transfer coefficient and pressure drop. Comparison with relevant data from other sources indicates a reasonable agreement. An empirical correlation was obtained for predicting condensation heat transfer coefficient. The present study may be considered of a practical and theoretical interest for the design of the helical double-tube condensers using R-134a as the working fluid. M. El-Sayed Mosaad is on leave from Mechanical Engineering Department, Mansoura University, Egypt.  相似文献   

11.
In this study, effect of electrohydrodynamic (EHD) on the condensation heat transfer enhancement and pressure drop of pure R-134a are experimentally investigated. The test section is a 2.5 m long counterflow double tube heat exchanger with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The inner tube is made from smooth horizontal copper tubing of 9.52 mm outer diameter. The electrode is made from stainless steel wire of 1.47 mm diameter. The test runs are performed at average saturated temperatures ranging between 40 and 60°C, mass flux ranging between 200 and 600 kg/m2 s, heat flux ranging between 10 and 20 kW/m2 and applied voltage at 2.5 kV. For the presence of the electrode, the experimental results indicate that the maximum heat transfer enhancement ratio is around 30% while the maximum increase in pressure drop is about 25%.  相似文献   

12.
The heat transfer process occurring in a condensing heat exchanger where noncondensible gases are dominant in volume is different from the condensation heat transfer of the water vapor containing small amount of noncondensible gases. In the process the mass transfer due to the vapor condensation contributes an important part to the total heat transfer. In this paper, the Colburn-Hougen method is introduced to analyze the heat and mass transfer process when the water vapor entrained in a gas stream condenses into water on the tube wall. The major influential factors of the convective-condensation heat transfer coefficient are found as follows: the partial pressure of the vapor p v , the temperature of the outer tube wall T w , the mixture temperature T g , Re and Pr. A new dimensionless number Ch, which is defined as condensation factor, has been proposed by dimensional analysis. In order to determine the relevant constants and investigate the convection-condensation heat and mass transfer characteristics of the condensing heat exchanger of a gas fired condensing boiler, a single row plain tube heat exchanger is designed, and experiments have been conducted with vapor-air mixture used to simulate flue gases. The experimental results show that the convection-condensation heat transfer coefficient is 1.52 times higher than that of the forced convection without condensation. Based on the experimental data, the normalized formula for convention-condensation heat transfer coefficient is obtained. A heat transfer area m2 - Ch condensation factor - c p specific heat at constant pressure, J/(kg·K) - G mass flux Kg/(m2·s) - h heat transfer coefficient W/(m2·K) - J J-factor - Nu Nusselt number - pa pressure - Pr Prandtl number - Q heat transfer rate - q heat flux W/m2 - r latent heat, kJ/kg - Re Reynolds number - Sc Schmidt number - T temperature, C or K - heat conductivity m W/(m·K) - density, kg·m3 - g gas - h moistened hot air - i interface - v vapor - w water  相似文献   

13.
A numerical investigation of the mixed convection heat transfer from vertical helically coiled tubes in a cylindrical shell at various Reynolds and Rayleigh numbers, various coil‐to‐tube diameter ratios and non‐dimensional coil pitches was carried out. The particular difference in this study compared with other similar studies is the boundary conditions for the helical coil. Most studies focus on constant wall temperature or constant heat flux, whereas in this study it was a fluid‐to‐fluid heat exchanger. The purpose of this article is to assess the influence of the tube diameter, coil pitch and shell‐side mass flow rate on shell‐side heat transfer coefficient of the heat exchanger. Different characteristic lengths were used in the Nusselt number calculations to determine which length best fits the data and finally it has been shown that the normalized length of the shell‐side of the heat exchanger reasonably demonstrates the desired relation. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
This paper investigates the effect of vapour super-heating on hydrocarbon refrigerant 600a (Isobutane), 290 (Propane) and 1270 (Propylene) condensation inside a brazed plate heat exchanger.Vapour super-heating increases heat transfer coefficient with respect to saturated vapour, whereas no effect was observed on pressure drop.The super-heated vapour condensation data shows the same trend vs. refrigerant mass flux as the saturated vapour condensation data, but with higher absolute values. A transition point between gravity controlled and forced convection condensation has been found for a refrigerant mass flux around 15-18 kg m−2 s−1 depending on refrigerant type. The super-heated vapour heat transfer coefficients are from 5% to 10% higher than those of saturated vapour under the same refrigerant mass flux.The experimental heat transfer coefficients have been compared against Webb (1998) model for forced convection condensation of super-heated vapour: the mean absolute percentage deviation between the experimental and calculated data is ±18.3%.HC-1270 shows super-heated vapour heat transfer coefficient 5% higher than HC-600a and 10-15% higher than HC-290 together with total pressure drops 20-25% lower than HC-290 and 50-66% lower than HC-600a under the same mass flux.  相似文献   

15.
One of the criteria for evaluating the performance of a heat exchanger with extended surfaces is the pumping power required for a specified heat duty. The results of an experimental project to relate the pumping power to heat transfer augmentation in a double-pipe heat exchanger are reported. The inner, electrically heated pipe was provided with external, rectangular, axial extended surfaces with interruptions. Heat transfer augmentation and friction factors were determined for different configurations with air as the fluid. Starting with continuous fins, cuts were introduced in the fins to give four ratios of the finssegment length to the gap between the segments, and finally all the fins were removed, which resulted in smooth pipes. Five different mass flow rates in two different inner pipes were employed. Lengths, surface areas, and pumping powers for finned pipes are compared with those for smooth pipes. The average heat transfer coefficient increases with an increase in the frequency of the interruptions. For equal heat transfer rates a significant reduction in the lengths can be achieved by interrupted fins. In many cases the reduction in the length is also accompanied by a reduction in the pumping power.  相似文献   

16.
In the present study, the heat transfer characteristics in dry surface conditions of a new type of heat exchanger, namely a helically coiled finned tube heat exchanger, is experimentally investigated. The test section, which is a helically coiled fined tube heat exchanger, consists of a shell and a helical coil unit. The helical coil unit consists of four concentric helically coiled tubes of different diameters. Each tube is constructed by bending straight copper tube into a helical coil. Aluminium crimped spiral fins with thickness of 0.5 mm and outer diameter of 28.25 mm are placed around the tube. The edge of fin at the inner diameter is corrugated. Ambient air is used as a working fluid in the shell side while hot water is used for the tube-side. The test runs are done at air mass flow rates ranging between 0.04 and 0.13 kg/s. The water mass flow rates are between 0.2 and 0.4 kg/s. The water temperatures are between 40 and 50°C. The effects of the inlet conditions of both working fluids flowing through the heat exchanger on the heat transfer coefficients are discussed. The air-side heat transfer coefficient presented in term of the Colburn J factor is proportional to inlet-water temperature and water mass flow rate. The heat exchanger effectiveness tends to increase with increasing water mass flow rate and also slightly increases with increasing inlet water temperature.  相似文献   

17.
Flow condensation heat transfer coefficients (HTCs) and pressure drop of R22, propylene, propane, DME and isobutane are measured on a horizontal plain tube. The main test section in the experimental flow loop is made of a plain copper tube of 8.8 mm inner diameter and 530 mm length. The refrigerant is cooled by passing cold water through the annulus surrounding the test section. Tests are performed at a fixed refrigerant saturation temperature of 40 ± 0.2 °C with mass fluxes of 100, 200, and 300 kg/m2 s and heat flux of 7.3–7.7 kW/m2. The heat transfer and pressure drop data are obtained in the vapor quality range of 10–90%. Test results show that for a given mass flux the flow condensation HTCs of propylene, propane, DME and isobutane are higher than those of R22 by up to 46.8%, 53.3%, 93.5% and 61.6%, respectively. Also well-known correlations developed based upon conventional fluorocarbon refrigerants predict the present data within a mean deviation of 33%. Finally, the pressure drop increases as the mass flux and quality increase and isobutane shows the highest pressure drop due to its lowest vapor pressure among the fluids tested.  相似文献   

18.
The in-tube cooling flow and heat transfer characteristics of R134a at supercritical pressures are measured experimentally for various pressures and mass fluxes in a horizontal tube. The tube is made of stainless steel with an inner diameter of 4.01 mm. Experiments are conducted for mass fluxes from 70 kg/m2 s to 405 kg/m2 s and pressures from 4.5 MPa to 5.5 MPa. The inlet refrigerant temperature is from 80 °C to 140 °C. The results show that the refrigerant temperature, the mass flux and the pressure all significantly affect the flow and heat transfer characteristics of R134a at supercritical pressures. The experimentally measured frictional pressure drop and heat transfer coefficient are compared with predicted results from several existing correlations. The comparisons show that the predicted frictional pressure drop using Petrov and Popov’s correlation accounting for the density and viscosity variations agree well with the measured data. Gnielinski’s correlation for the heat transfer coefficient agrees best with the measured data with deviations not exceeding 25%, while correlations based on supercritical CO2 heat transfer data overcorrect for the influence of the thermophysical property variations resulting in larger deviations. A new empirical correlation is developed based on the measured results by modifying Gnielinski’s equation with thermophysical property terms including both the property variations from the inlet to the outlet of the entire test section and from the bulk to the wall. Most of the experimental data is predicted by the new correlation within a range of 15%.  相似文献   

19.
Two-phase friction and heat transfer characteristics for R-22/R-407C inside a 6.5-mm smooth tube are reported in this study. The heat transfer results for G=100 and 400 kg/m2 s were reported in the present study, and the adiabatic frictional pressure drop was recorded in the range of 100 to 700 kg/m2 s. It is found that the development of flow pattern for R-407C falls behind R-22. This may explain the lower pressure drops for R-407C. The major heat transfer mechanism at low mass flux is nucleate boiling, and virtually becomes the convective evaporation as mass flux increase to G=400 krg/m2 s, Meanwhile, the reduction of heat transfer coefficients for R-407C mixtures are especially profound at low mass flux, and the reduction of heat transfer coefficient decreases with the increase of mass flux.  相似文献   

20.
This study intended to verify the cooling heat transfer characteristics of supercritical gas for refrigerating and air-conditioning devices that use CO2, a natural refrigerant, as the operating fluid. Experiments were performed with a gas cooler, which was the test part. The gas cooler was a heat exchanger made of a micro-fin tube with an inner diameter of 4.6 mm and an outer diameter of 5.0 mm. The experiment results are summarized as follows. The heat transfer coefficient, according to the mass flux, peaked at the low cooling pressure of 8.0 MPa in the gas cooler, and reached its minimum at the high pressure of 10.0 MPa. Furthermore, when the mass flux of the refrigerant increased, the coefficient increased faster with the lower cooling pressure in the gas cooler. The heat transfer coefficient, according to the shape of the heat transfer tube, showed that the maximum values of the CO2 cooling heat transfer coefficients of the smooth tube and the micro-fin tube were found at 44.7 °C, which were the pseudo-critical temperatures for the entrance pressures. It was found that the cooling heat transfer coefficient of the micro-fin tube increased by 12–39 % more than that of the smooth tube. The experiment results for the CO2 heat transfer coefficients of the smooth tube and the micro-fin tube were compared with the results estimated from previous correlations. It was found that the experiment values generally significantly differed from and the experiment values greater than the estimated values. The differences were especially greater in the vicinity of the critical temperature points. Based on these results, a new correlation was suggested that includes the density ratio and the specific heat ratio.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏