首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 15 毫秒
1.
To merge the beam from either of the two injectors to the main linac, a dog-leg system will be employed in the second Medium Energy Beam Transport (MEBT2) line of the China ADS driving accelerator. The achromatic condition has to be guaranteed to avoid beam center excursion against energy jitter. RF cavities were found to be indispensable to control the bunch length growth in the dog-leg system of MEBT2. The full uncoupling between transverse and longitudinal plane is desired to minimize the growth of projected rms emittances. The uncoupled achromatic condition of this dogleg system with the presence of RF bunching cavities will be deduced using the transfer matrices method. It is found that, to fulfill the uncoupling condition, the distance between the bunching cavities is uniquely determined by the maximum energy gain of the RF cavities. The theoretical analysis is verified by the simulation code TraceWin. The space charge effect on the uncoupled achromatic condition and the beam emittance growth will Mso be discussed.  相似文献   

2.
The numerical models of liquid-filled straight pipe system with active silencers are established. The inffuence of the near field of secondary source in the active silencers and the elasticity of pipe wall on active noise control performance under sound excitation is analyzed.The results show that the near field of secondary source is non-uniform, and the active control effect of some frequencies is poor or even the sound pressure level will increase when the error points are located in this reg...  相似文献   

3.
A new H-ion source has been installed successfully and will be used to serve the China Spallation Neutron Source(CSNS). In this paper, we report various components of the ion source, including the discharge chamber, temperature, cooling system, extraction electrodes, analyzing magnet, remote control system and so on.Compared to the previous experimental ion source, some improvements have been made to make the ion source more compact and convenient. In the present arrangement, the Penning field is generated by a pair of pole tip extensions on the 90°analyzing magnet instead of by a separate circuit. For the remote control system, F3RP61-2L is applied to the accelerator online control system for the first time. In the running of the ion source, a stable pulse H-beam with a current of 50 m A at an energy of 50 ke V is produced. The extraction frequency and pulse width is 25 Hz and500 μs, respectively. Furthermore, an emittance scanner has been installed and measurements are in progress.  相似文献   

4.
The BEPC will increase its luminosity ten times with upgrade of both the machine and detector,which is the project BEPCII,The project will be started at beginning chine and detector,which is the project BEPCII.The project will be started at beginning of 2002 and finished within 3-4 years.In order to reach the goal of the BEPCII,a number of new equipment will be added in the system,such as the superconducting RF cavities,new magnet power supplies and beam feedback system,and the BEPC control system has to be upgraded.The BEPC control system was built in 1987 and was upgraded in 1994.It is an Open VMS and CAMAC based-system,some equipment is controlled by PCs.We are going to upgrade the existing system by EPICS.Several VME IOCs will be added in the system with feildbus,PLCs for the new equipment control.And we will keep the existing system in use,such as CAMAC hardware ,PC based sub-control and application programs,which will be merged into the EPICS system.Recently the development of the EPICS prototype has been started.Regard some slow control,commercial SCADA product can be chosen as the development tool.We have just finished a prototype with the SCADA product Wizcon.This paper will describe the system design and development issues.  相似文献   

5.
Motivated by a phenomenon in an experiment conducted in the Northwestern Pacific indicating that the energy of the received signal around the sound channel axis is much greater than that at shallower depths,we study sound propagation from the transitional area(shelfbreak)to deep water.Numerical simulations with different source depths are first performed,from which we reach the following conclusions.When the source is located near the sea surface,sound will be strongly attenuated by bottom losses in a range-independent oceanic environment,whereas it can propagate to a very long range because of the continental slope.When the source is mounted on the bottom in shallow water,acoustic energy will be trapped near the sound channel axis,and it converges more evidently than the case where the source is located near the sea surface.Then,numerical simulations with different source ranges are performed.By comparing the relative energy level in the vertical direction between the numerical simulations and the experimental data,the range of the air-gun source can be approximated.  相似文献   

6.
The high charge state all permanent Electron Cyclotron Resonance Ion Source(ECRIS)LAPECR2 (Lanzhou All Permanent magnet ECR ion source No.2)has been successfully put on the 320kV HV platform at IMP and also has been connected with the successive LEBT system.This source is the largest and heaviest all permanent magnet ECRIS in the world.The maximum mirror field is 1.28T(without iron plug)and the effective plasma chamber volume is as large as (?)67mm×255mm.It was designed to be operated at 14.5GHz and aimed to produce medium charge state and high charge state gaseous and also metallic ion beams.The source has already successfully delivered some intense gaseous ion beams to successive experimental terminals.This paper will give a brief overview of the basic features of this permanent magnet ECRIS.Then commissioning results of this source on the platform,the design of the extraction system together with the successive LEBT system will be presented.  相似文献   

7.
A design and testing of a cost-effective distributed optical remote sensing methane system, which will help one to detect gas leaks from multi-coal face in mines simultaneously, is presented. The fundamentals of the remote detection are based on frequency-modulation spectroscopy (FMS) and harmonic detection. By utilizing fiber-optic splitting technique and reference-signal restoring circuit, the remote sensing system is feasible to employ single laser source to get multi-spot measurement in the near infrared region so that the system described here shows sufficient sensibility, considerably increased reliability and marketability over the presently available system. The minimum measurable path-integrated concentration is estimated to be about 423 ppb-m by experimentation.  相似文献   

8.
A post-acceleration system based on the accelerators at CSNS(China Spallation Neutron Source) is proposed to build a super-beam facility for neutrino physics.Two post-acceleration schemes,one using superconducting dipole magnets in the main ring and the other using room temperature magnets,have been studied,both to achieve the final proton energy of 128 GeV and the beam power of 4 MW by taking 10% of the CSNS beam from the neutron source.The main design features and the comparison for the two schemes are presented.The CSNS super-beam facility will be very competitive in long-baseline neutrino physics studies,compared with other super-beam facilities proposed in the world.  相似文献   

9.
A new H- ion source has been installed successfully and will be used to serve the China Spallation Neutron Source (CSNS). In this paper, we report various components of the ion source, including the discharge chamber, temperature, cooling system, extraction electrodes, analyzing magnet, remote control system and so on. Compared to the previous experimental ion source, some improvements have been made to make the ion source more compact and convenient. In the present arrangement, the Penning field is generated by a pair of pole tip extensions on the 90° analyzing magnet instead of by a separate circuit. For the remote control system, F3RP61-2L is applied to the accelerator online control system for the first time. In the running of the ion source, a stable pulse H- beam with a current of 50 mA at an energy of 50 keV is produced. The extraction frequency and pulse width is 25 Hz and 500 μs, respectively. Furthermore, an emittance scanner has been installed and measurements are in progress.  相似文献   

10.
超导ECR离子源DECRIS-SC2   总被引:1,自引:0,他引:1  
A new compact version of the"liquid He-free"superconducting Electron Cyclotron Resonance Ion Source,to be used as an injector for the U-400M cyclotron,is presently under construction at the FLNR in collaboration with LHE(JINR).The axial magnetic field of the source is created by the superconducting magnet,and the NdFeB hexapole is used for the radial plasma confinement.The microwave frequency of 14GHz will be used for ECR plasma heating.The DECRIS-SC2 superconducting magnet is designed for the induction of a magnetic field on the axis of the source of up to 1.4T(extraction side)and 1.9T(injection side) at nominal current of 75A.Cooling of the coils is carried out by CM cryocooler with cooling power of 1W at the temperature 4.5K.The basic design features of the superconducting magnet and of the ion source are presented.The main parts of the source are in production.The first beam test of the source is expected in the beginning of 2007.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号